Manuel d’utilisation Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE

25 pages 1.45 mb
Télécharger

Aller à la page of 25

Summary
  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 1

    www .omega.com e-mail: info@omega.com U ser ’ s Guide BNC-08DI, BNC-16DI AND BNC-16SE T erminal Boards Shop online at ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 2

    W ARRANTY / DISCLAIMER OME GA ENGINEERING, INC. war rants this unit to be free of defects in materials and workmanship for a period of 1 3 months from date of purc hase. OM E GA ’ s W ARRAN TY adds an additional one (1) month grace period to the normal one (1) year pr oduct warranty to cover handling and shipping time. This ensures that OME GA ? ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 3

    19 BOARD ACCESSIBILITY ........................................................... 15 INPUT CONFIGURATIONS ......................................................... 14 BOARD COMPATIBILITY .......................................................... 12 P1 CONNECTOR MAP .............................................................. 10 P 6 & P 7 ... ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 4

    INTRODUCTION The BNC series of signal con nection boxes have been desig ned as univ ersal interfaces f or the DAS fam ily of analog I/O boards. T he BNC-08DI accepts u p to 8 differential pairs of analog inpu ts w hile the BNC- 16SE and the BNC- 16DI can accept up to 64 sing le end ed or 3 2 differ ential analo g inputs. For user co nvenience , a v ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 5

    BNC-08DI The BNC-08D I incorporates 16 f ront panel m ounted BNC con nectors prov iding up to 8 dif feren tial analog i nputs to the C IO-DA S family of data acquisition boards. B1-B16 The 16 front panel mounted BNC connectors B1-B16, are routed through the enclosure to the rear panel-mounted 37 D connector P2. P2 The rear panel moun ted 37 p in D ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 6

    EXTERNAL TRIGGER The EXTERNAL TRIGGER BNC con nectors B17 and B18 are provided for application s that requ ire external digital triggering of t he data acquisition board. These connectors could also be used in applications requiring synchronization to the digital trigger si gnal. The digital trigger signal is available on connectors P1-P4 as illust ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 7

    BNC-16DI The BNC-16 DI incorpor ates 16 front panel mounted BNC’s allowing connection of up to 8 d ifferential analog inputs to the CIO-DAS and PCI family of data acquisition board s. The BNC-16DI can accom modate boards with either 37 or 50 pin I/O connectors; with connector P2 used to interface to data acquisition boards utilizing a 37 pin, D t ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 8

    . . P1 The front panel m ounted DB37 connector P1 provides a variety of I/O sig nals, n ot including the 16 analog input signals from BNC’s B1-B16. P lease refer to the P1 CONNECTOR MAP section for a detailed explanation of P1’s connection schem e and signal availability. 5 ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 9

    EXTERNAL TRIGGER The EXTERNAL TRIGGER BNC con nectors B17 and B18 are provided for application s that requ ire external digital triggering of t he data acquisition board. These connectors could also be used in applications requiring synchronization to the digital trigger si gnal. The digital trigger signal is available on connectors P1-P4 as illust ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 10

    Headers P6 and P7 are factory set to the “1-2” position, pre-config uring B15 and B16 as analog input BNC’s. For those applicati ons w hich require D/A outputs along with B15 and B16 to be used in the an alog input m ode; the user can leave B15 and B16 in the an a log input mode and access the D/A outputs at connector P1. The following diagra ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 11

    BNC-16SE The BNC-16S E incorporates 16 front panel mou nted BNC’s allow ing connect ion of u p to 16 singl e-ended an alog inpu ts to th e CIO-DAS an d PCI family of data acquisition boards. T he BNC-16SE can accomm o date boards with eith er 37 or 50 pin I/O connectors; with connector P2 used to interface to data acquisition boards utilizing a 3 ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 12

    . P1 The front panel m ounted DB37 connector P1 provides a variety of I/O sig nals, n ot including the 16 analog input signals from BNC’s B1-B16. P lease refer to the P1 CONNECTOR MAP section for a detailed explanation of P1’s connection schem e and signal availability. 9 ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 13

    EXTERNAL TRIGGER The EXTERNAL TRIGGER BNC con nectors B17 and B18 are provided for application s that requ ire external digital triggering of t he data acquisition board. These connectors could also be used in applications requiring synchronization to the digital trigger si gnal. The digital trigger signal is available on connectors P1-P4 as illust ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 14

    Headers P6 and P7 are factory set to the “1-2” position, pre-config uring B15 and B16 as analog input BNC’s. For those applicati ons w hich require D/A outputs along with B15 and B16 to be used in the an alog input m ode; the user can leave B15 and B16 in the an a log input mode and access the D/A outputs at connector P1. The following diagra ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 15

    P1 CONNECTOR MAP Connector P1 prov ides the u ser w ith a variety of I/O sign als, not including th e 16 analog input signals from B1-B16. T he following diagram illustrates the connection schem e used to route these signals among connectors P2, P3 and P4 to connector P1. These sig nals are labeled “PASS” signals (except for the trigger and D/A ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 16

    3&RQQHFWRU0DSIRU%1&', 13 ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 17

    BOARD COMPATIBILITY The BNC-08DI is compatible with the following DAS boards: 8 Differential Inputs CIO-DAS08-PGM 8 Differential Inputs CIO-DAS08-PGL 8 Differential Inputs CIO-DAS08-PGH 8 Differential Inputs CIO-DAS08-PGA 8 Differential Inputs CIO-DAS08-AOM 8 Differential Inputs CIO-DAS08-AOL 8 Differential Inputs CIO-DAS08-AOH 8 Differential Input ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 18

    INPUT CONFIGURATIONS Each BNC connector of the BNC-08/16 DI and the BNC-16SE incorpo rates pro gramm ab le, signal conditioning circuitry, wh ich allows the user to connect a wide variety of options including filtering, bypassing, voltage division and termination. For situations wh ere the facto ry installe d shunt r esisto rs RX A or RXB have been ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 19

    open resistor open open open open RXF open open open 0 ohm 0 ohm open RXE capacitor open open capacitor resistor open RXD 0 ohm open open resistor resistor open RXC 0 ohm 0 ohm 0 ohm 0 ohm 0 ohm 0 ohm RXB* 0 ohm 0 ohm capacitor open open 0 ohm RXA* Bypass 50 Ohm AC Couple RC Filter R Divider Normal *factory installed 0 ohm resistors %1&? ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 20

    The following diagram illustrates the signal conditioning circuitry of a differential analog input channels used on the BNC-16D I and the BNC-08DI. resistor resistor resistor resistor resistor resistor RSX open resistor open open open open RXF open open open 0 ohm 0 ohm open RXE capacitor open open capacitor resistor open RXD 0 ohm open open resist ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 21

    The following illustrations describe some comm on differential mode connection meth ods o f the BNC-08/16DI enclosure. T hese are just a few of the many possible connection methods made possible using the programmable signal conditioning circuits. 1. Diagram A . describes a true differential setup utilizin g a pair of coaxial cables. T he grounding ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 22

    BOARD ACCESSIBILITY Accessi ng the in dividual BNC input con figu ration circuits, or headers P6 or P7 (B NC-16SE, BNC16DI on ly) can be easily accomplished by removing the following hardware: enclosure screws (2), External Trigger nut and washer, and P2 set screws (2). %1&6(%1&', %1&', 19 ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 23

    EC Declaration of Conformity We, ComputerBoards, Inc., declare under sole responsibility that the product: Description Part Number BNC Boxes BNC 08/16DI BNC 16SE to which this declaration relates, meets the essential requirements, is in conformity with, and CE marking has been applied according to the relevant EC Directives listed below using the r ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 24

    Servicing Nor th America: USA: One Omega Drive, P.O. Box 4047 ISO 9001 Certified Stamford CT 06907-0047 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1, Canada TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sale ...

  • Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - page 25

    Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at www .omega.com TEMPERA TURE   Thermocouple, RTD & Thermistor Probes, Connectors, Panels & Assemblies   Wire: Thermocouple, RTD & Thermistor   Calibrators & Ice Point References   Recorders, Controllers ...

Fabricant Omega Engineering Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilOmega Engineering BNC-08DI, BNC-16DI, BNC-16SE peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Engineering
- manuels d’utilisations BNC-08DI, BNC-16DI, BNC-16SE
- fiches produit Omega Engineering
- dépliants
- ou étiquettes-énergie Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE.

Manuel d’utilisation complet de l’appareil Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE.

Le manuel d’utilisation complet Omega Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Engineering BNC-08DI, BNC-16DI, BNC-16SE qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Engineering BNC-08DI, BNC-16DI, BNC-16SE il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)