Manuel d’utilisation MicroNet Technology SP5050

61 pages 1.5 mb
Télécharger

Aller à la page of 61

Summary
  • MicroNet Technology SP5050 - page 1

    User ’ s Manual SP5050/SP5052/SP5054 IP T elephony Gate way , FXO Interfa c e Website : http://w ww .micronet.info ...

  • MicroNet Technology SP5050 - page 2

    2 1. INTRODUCTION ....................................................................................................................................... 3 1.1 F EA TURES AND SPECIFICA TION ................................................................................................................. 3 1.2 A PPE AR AN CE ......................... ...

  • MicroNet Technology SP5050 - page 3

    3 1. Introduction The Micronet S P5050 Series FX O gateway provi des voice/fax serv ice over IP network with H. 323 v3 protocol. By conn ecting to y our e xisti ng ADSL or cable modem serv ice, whic h allows the use of a single, netw ork for voice and f ax servi ces with conseq uent saving in netw ork infrastruct ure and great ly reduced telephon e ...

  • MicroNet Technology SP5050 - page 4

    4 Management Features: - Console port: RS-232C port - TEL NET - HTTP Brower (e.g . Internet Ex plorer) 1.2 A ppearance Front p anel: The L ED light pr ovides system message of Micron et SP5050 Series. Fron t pane l of SP5 050 Power : Light on means Micr onet SP5050 Se ries is power on. L1-L6 : Lig ht on means the li ne is in use. Link : Light o n m ...

  • MicroNet Technology SP5050 - page 5

    5 PIN 1, 2: T r ansmit PIN 3, 6: Receive COM: RS232 console port (9-pin M ale connector , as the same as th e computer). Male co nnecto r (as the sa me as th e PC) 9 PIN D-SUB MALE a t the V oIP FXO gatew ay Pin Name Dir Description 2 RXD Å Receive Data 3 TXD Æ T ransmi t Data 5 GND ─ System Grou nd L1 ~ L6: RJ-1 1 (PSTN or Extension Line of PB ...

  • MicroNet Technology SP5050 - page 6

    6 2. Sy stem Operating Procedure 2.1 System Requirement 2.2 T elephone Line Requ irement 2.3 IP Environment Setting ST AR T END 2.4 Hyper T erminal Setting ...

  • MicroNet Technology SP5050 - page 7

    7 2.1 System Requirement 1. One PC ( a) Pentiu m 100 or abov e, 64 MB DRAM , W indow s 98 or abov e. (b) Network card (RJ-45) & CO M port 2. One s tandard RS-232 straig ht cable with t w o female connectors depended on the dif ferent model . 3. PSTN li nes / PBX ex tension lines ( up to 4 lines ). 4. Software to ols (a) Hyper ter m inal, teln e ...

  • MicroNet Technology SP5050 - page 8

    8 2. Define a name suc h as ‘SP5050 Gateway’ for thi s new connectio n. 3. After pressi ng OK butt on, the next w indow popping up is necessary to connect choos e COM Port. ...

  • MicroNet Technology SP5050 - page 9

    9 Note: Some connecti on failed is der ived the PC C OM Port. If user cann ot open the com port, for ex ample com 1, please try another co m port, ex.co m port 2. 4. Configure the C OM Port Proper ties as follow ing: (1) Bits per se cond : 960 0 (2) Flow contro l : None Press ‘OK’ butto n, and start t o configure V oIP FXO gateway . ...

  • MicroNet Technology SP5050 - page 10

    10 3. Initializing V oIP FXO Gateway Setting 3.1 Gatekeeper Mode (a) Configure V oIP FXO ga t ewa y Passwo rd (b) Configure V oIP FXO gat eway IP Address (c) Gatekee per Mode Settings ST AR T END (d) Save V oIP FXO gatewa y Config u ration & Reboot V o IP FXO g atewa y ...

  • MicroNet Technology SP5050 - page 11

    11 (a) Configure V oIP FXO gateway Pa ssword It is impor tant for the first ti me user to fol low the operati on proced ure. 1. Power on th e V oIP FXO gateway and the sentenc e “Please wait w hile system is initializin g…………S” is displayed. Attache d TCP/IP interf ace to cpm unit 0 Attac hing interface l o0...done Please wait while sys ...

  • MicroNet Technology SP5050 - page 12

    12 (b) Configure V oIP FXO gateway IP Address Use “ ifaddr ” command to set up V oIP FXO g ateway’ s IP address and related networ k information. An exampl e is demonstr ated below : usr/config $ ifaddr –ip 1 0.1.1.1 –mask 255. 2555.255.0 –gate 10.1. 1.254 Note: this is to assign V oIP FXO gateway an IP a ddress of “10.1.1. 1”, subn ...

  • MicroNet Technology SP5050 - page 13

    13 Note: m ode 1 is for Peer -T o-Peer (no n-gk) mode, while m ode 0 is for GK mode. 2. Configur e Phonebo ok, using “pbook” c ommand. Users can refer to ch apter 5.1 1 [pbook] command for more information. usr/config$ p book –add nam e TEST1 ip 1 0.1.1.1 e164 10 Note: The comm and is to add a record on to Phonebook. Af ter the com mand compl ...

  • MicroNet Technology SP5050 - page 14

    14 Dynami c IP Address – usr/config$ ifaddr –i psharing 1 Note: W it h Dynamic W AN IP Address, a Gatekeep er with a valid IP address for V o IP FXO gateway is a must. In other w ord, it is not worka ble in Peer -to-Peer m ode while dyn amic WAN IP Address. IP Shar ing devic e must have a function t o do IP/Port map ping. Some is named as DMZ, ...

  • MicroNet Technology SP5050 - page 15

    15 4. Disconnect T one Configuration This appli cation note i s going to descr ibe the pr ocedures of con f iguri ng the disconnect ton e on V oIP FXO gateway in or der to release LINE ports of V oIP FXO gatew ay after PSTN/PBX caller par ty is hung up. 4.1 What is Disconnect T one A cal ler make a telepho ne call to gateway from PSTN side, V oIP F ...

  • MicroNet Technology SP5050 - page 16

    16 Otherw ise it may be released after one minute or lock this LINE per manently. The tone table parame ters are show n as follow s. LowFr eq 480 : Low freq uency is 480 H Z HighFr eq 620 : High freq uency is 620 HZ LowFr eqLevel 8 : Low freq uency level received rang e from PSTN/PBX HighFr eqLevel 8 : Hi gh frequency level receiv ed range from PST ...

  • MicroNet Technology SP5050 - page 17

    17 620/480, t ake the follo wing procedur es. 620/47 9 620/48 0 620/48 1 621/47 9 621/48 0 621/48 1 619/47 9 619/48 0 619/48 1 If the lin e port of g ateway was locked, please us e “hangup 0” command to release LIN E 1, “hanhup 1” to release LIN E 2…etc. 4.4 Adjust Input Tone Level Sometimes t he disconnect tone level is t oo low to be de ...

  • MicroNet Technology SP5050 - page 18

    18 5. Command list s 5.1 [help] command T y pe help or man or ? to l ist all the available com mand. usr/config$ ? help help/m an/? [command] quit quit/exit/cl ose debug show debug m essage reboot reboot local machine flash clean configur ation from flash rom comm it commi t flash rom data ifaddr internet address m anipulation time show current tim ...

  • MicroNet Technology SP5050 - page 19

    19 Open debug messa ge will show up specific info rmation while V oIP FXO gatew ay is in operati on. Aft er executing t he debug comma nd, it should execute c ommand debug -open as well. On e example is demons trated below . usr/config $ debug -add h323 vp usr/config $ debug -ope n Parame ters Usage: -st atus Di splay the enable d debug f lags. -ad ...

  • MicroNet Technology SP5050 - page 20

    20 Wa r n i n g : Once users ex ecute flash –clean, all the configur ations of V oIP FXO gateway will be cle aned. This can only be executed b y user who log in wit h root 5.6 [commit] command Save changes after con f iguri ng the V oIP FXO gatew ay . usr/config$ com mit This m ay take a few s econds, please wait.... Commit to flash memory ok! us ...

  • MicroNet Technology SP5050 - page 21

    21 ifaddr -tim e zone 8 Parame ters Usage: -print print current IP setting -ip assigned IP address fo r V oIP FXO gateway -mask internet subnet mask -gate IP de fault gatew ay -dhcp Dynamic Ho st Conf iguration (1 = ON; 0 = OFF) -sntp Simple Netw ork T ime Pr otocol (1 = ON; 0 = OFF) W hen SNTP function is ac tivated, u sers have to s p ecify a SNT ...

  • MicroNet Technology SP5050 - page 22

    22 no ans w er from 210.54.23.129 usr/config $ ping 192.1 68.4.121 PING 192.1 68.4.121: 5 6 data bytes 64 bytes from 192.168. 4.121: icmp_seq= 0. tim e=5. ms 64 bytes from 192.168. 4.121: icmp_seq= 1. tim e=0. ms 64 bytes from 192.168. 4.121: icmp_seq= 2. tim e=0. ms 64 bytes from 192.168. 4.121: icmp_seq= 3. tim e=0. ms ----192.168.4.121 PING S ta ...

  • MicroNet Technology SP5050 - page 23

    23 Please wait for Wr iting...block 1 Please wait for Wr iting...block 2 Replay Ne w Greeting V oice?(y/n): Disconnect T one Analy sis : please follow instructi ons on screen (Selecti on 2). First call in line1 o f V oIP FXO gateway f rom PSTN si de (now can’t hear greeting ), hang up the phone a nd press “enter ” to start record disc onnect ...

  • MicroNet Technology SP5050 - page 24

    24 3.exit. ----------- ------- ------ ------ ----------- ------- -- Please inpu t function(1 ~3): 3 Are you sure t o EXIT?!(y/n): y usr/config$ 5.1 1 [pbook] command Phone Book function a llows users to de fine their own numbers, w hich ma pping t o real IP address. It is effe ctive only in pee r-to- peer mo de. W hen adding a record to Pho ne Book ...

  • MicroNet Technology SP5050 - page 25

    25 phone number . Note: <index num ber> m eans the sequence num ber in pho ne book. If user s do not request a specific in dex number in phone bo ok, V oIP FXO g ateway will give each record a automati c sequence num ber as index. -add add a new record t o phone book . When ad ding a recor d, users have to speci f y name , ip , and e1 64 numb ...

  • MicroNet Technology SP5050 - page 26

    26 5.12 [pppoe] Display PPPoE related i nformation. PPPoE devi ce informati on and configur ation Usage: pppoe [-pri nt]|[-open]| [-close] pppoe [-d ev on/off][- id usernam e][-pwd pass word] -print Display PPPoE device infor mation. -dev Enable(= 1) or Disable( =0) device. -open Open PPPoE c onnection. -close Disconnect PPP oE connection. -id Conn ...

  • MicroNet Technology SP5050 - page 27

    27 -id to The duration of two pressed di gits in di al mode -eod Digit type of end of dial ing. ( 0:No e nd of diali ng, 1:[*] button, 2:[#] butto n ) -seizure Choose line s eizure mode (None/UCD). -2nddial Config GW t o accept 2nd dtmf set. In this m ode, devic e from IP si de needs to dial G W 's E164, wait for PSTN dialtone, and then dial o ...

  • MicroNet Technology SP5050 - page 28

    28 1 (Direct In Lin e Service): This feature m ust be impleme nted in a pai r of FXO produc ts in Gat ekeeper mode and set bureau – table command. In Direct In Line Ser vice V oIP FXO gateway will connected vi a gateke eper to pre-de f ined E. 164 number . For exampl e: $bureau –t able 1 192.168. 4.184 123 (please refer t o 5.21 bureau command) ...

  • MicroNet Technology SP5050 - page 29

    29 value i s set to enable a ll ports. - idto The durati on of two pressed digits in dial mode - eod: Digi t t ype o f end o f dial ing. ( 0:No end of dialing , 1:[*] button, 2:[#]but ton ) - seiz ure line seiz ure mode. None (0): W hen calling f rom IP side, choose L1 every time i f it is avail able. UCD (1): W hen calls fro m IP side, choo se L1 ...

  • MicroNet Technology SP5050 - page 30

    30 for response. If the ot her party cannot respond the message in 10 seconds, V oIP FX O gateway will regard the opposite p arty as IDLE sta te and disco nne ct th e ca ll. W hen CallAlive is deactivated, Ro undT ripDelay message will not be s ent during connection . - keyp ad keypad ty pe when rel ay DTMF sig nal. 0 : In-Ban d 1 : h.24 5 alphanum ...

  • MicroNet Technology SP5050 - page 31

    31 -gwtype Register as Gat eway (1) or T erminal ( 0 ) type -ras Gatekeeper RAS port (1024~ 65535). -range Dynami cally allocated port range (1 500~65535) . -respt o Max w aiting t ime for 1st re sponse to a new call (1~20 0). -connto Max waiti ng time for cal l establishm ent aft er receiving 1st response of a new call (1~20000) . Note: H.245 port ...

  • MicroNet Technology SP5050 - page 32

    32 -e164 e164 num ber , w hich is regi stered as phone nu mber in gate ke eper . -alias h323 ID, a ide ntification in h32 3 world for oth er parties’ recognit ion. The field mig ht be used as a k ey of auth orization or accounting in so me V oIP application. It is r ecommended to assign a special na me, or it m ight conflict w ith other dev ices. ...

  • MicroNet Technology SP5050 - page 33

    33 Usage: gk [-add typ e1 [[type2]...]] [- delete h323] [- ttl value [-enabl e 0/1] [-secur ity enable/di sable] -print Display the enabled debug flags. -enable Enable simple gatekeeper -ttl Set TTL value -add Add dynamic end point (h323 ID, E164, IP , port, type) -delete Delete dynamic endpoi nt -security enable En able secur ity check -security d ...

  • MicroNet Technology SP5050 - page 34

    34 usr/config$ voi ce V oice codec s etting inform ation and confi guration Usage: voice [-send [G 723 ms] [G71 1A m s] [G71 1 U m s] [G729A ms] ] [-volume [voice level ] [input le vel] [d tmf level]] [-nscng G723 used] [-echo used] [- mindelay t1] [- maxdelay t2] [-opt factor f] voice -prin t voice -priority [G7 23] [G71 1A] [G71 1U] [G729A] -prin ...

  • MicroNet Technology SP5050 - page 35

    35 -nscng silence suppr ession and comfort noise generati on setting (1 = ON; 0 = OFF). It i s appli cable to G .723 c odec only . An exampl e is demonstr ated below : usr/config$ voi ce -nscng g723 1 -mindel ay the mini mum jitter buf fer size. (D ef ault v alue= 90 ms) -maxdel ay the mi nimum ji tter buf fer size. ( Def ault v alue= 150 ms) usr/c ...

  • MicroNet Technology SP5050 - page 36

    36 -rtpty pe configure TOS type o f R T P p ackets from 0 to 7 -rtcpty pe configure T OS type of R T CP packe ts from 0 to 7 -sig delay configure signali ng pac kets as normal delay or low delay -rtpdelay configure R TP packet s as normal delay or lo w delay -rtcpdelay configure R T CP packe ts as nor mal delay or l ow delay -sig thruput configure ...

  • MicroNet Technology SP5050 - page 37

    37 -t38 T .38(F AX) enabled/dis abled. -fstart Fast start enabl ed/disabled. -tunnel H245 T unneling enabled/dis abled. -h245fs H245 separ ate channel after fast start . Exampl e: support -fst art 1 support - tunnel 0 support - h245fs 1 Parame ter Usages : -print print current setting in support command. -t38 to switch ON/OFF (1 = ON; 0 = OFF) T .3 ...

  • MicroNet Technology SP5050 - page 38

    38 -enable Enable PSTN Grouping -disable Disable PSTN Groupi ng -number Set num ber of divided groups -patt ern Set number of members in eac h group -e164 Set E.164 num ber for each group Exampl e: group -print group -enabl e group -disabl e group -num ber 2 -p attern 3 3 -e 164 01 02 group -pa ttern 3 1 -e164 100 200 group -e164 1 1 22 Parame ter ...

  • MicroNet Technology SP5050 - page 39

    39 -table Set Hot line/ Line T o Li ne inform ation. (Port range: 1~2) Note: Hotline f eature should be used togeth er with: $sysconf -service 2 (HotLine service) $sysconf -2nddial 0 (2nddial off) $h323 -mode 1 (peer -to-peer mode) Line T o Li ne feature sh ould be used together wi th: $sysconf -service 2 (HotLi ne service/ Line T o Line ) $sysconf ...

  • MicroNet Technology SP5050 - page 40

    40 5.22 [prefix] command This functi on can do di gits repl acement of inc oming call fro m IP side or PSTN side. usr/config $ prefix Prefix setti ng inform ation and confi guration Usage: prefix [- pstnrule i ndex oldnum ber newnum ber (index = 1 ~ 6)] [-iprule i ndex oldnum ber newnum ber (index = 1 ~ 6)] prefix - print -print Display pr efix inf ...

  • MicroNet Technology SP5050 - page 41

    41 -dspcore up date DSP kernel co de(optional) -dspapp updat e DSP applicati on code(opti onal) -rbpcm updat e RingBack T one PCM file( optional) -htpcm update Hold T one PC M file(optional ) -greeting updat e Greetings PCM file(optional ) -askpin updat e AskPin file(optional) -s IP address of TFTP/FTP server (mandatory) -f file name( mandatory) -m ...

  • MicroNet Technology SP5050 - page 42

    42 asking for pi ncode. -s to specify TFT P server ’s IP address when upgrading RO M files. -f to specify the target file name, which will repl ace the old one . -method to decide using TF T P or FTP as f ile transfer server . “0” stands for TFTP , while “1” stand s for FTP . -ftp if users choose FTP in abov e item, it is nec essary to sp ...

  • MicroNet Technology SP5050 - page 43

    43 6. Upgrade the V oIP FXO gateway V oIP FXO gatew ay supports rem ote download v ia TFTP for updatin g the new ROM file . Regard ing new versio n relea se, pl ease contact local distribu tor for more i nformation. TFTP/FTP server It is nec essary to prep are the TFTP/FTP ser ver program on the host PC as TFTP/FTP server . Afte r TFTP/FTP progra m ...

  • MicroNet Technology SP5050 - page 44

    44 -method to decide using TF T P or FTP as f ile transfer server . “0” stands for TFTP , while “1” stand s for FTP . -ftp if users choose FTP in abov e item, it is nec essary to speci fy pre-de f ined usern ame and passwor d when upgr ading files. ...

  • MicroNet Technology SP5050 - page 45

    45 Appendix: W eb configuration W e b management simple user guide The initi al version for HTTPD web management i nterface prov ides user to configur e easily r ather than comman d operating met hod throug h RS-232 / TEL NET . The configur ation funct ion and step are si milar wi th the way throug h command line. Please r efer to the ma nual for m ...

  • MicroNet Technology SP5050 - page 46

    46 St ep 2. Input the login name and p assword  Login na me: root / ad ministrator  Password: None (just press Enter in de fault value) The web i nterface mai n screen ...

  • MicroNet Technology SP5050 - page 47

    47 St ep 3. St art configure Most of all commands displayed in c onsole / telnet are transfer t o web interface. The most i mportant c ommands ar e Network Inter face, H323 I nformation, Co mmit Data and Reboot Sy stem. The method is as the same as c ommand mode. 1.1 Net w ork Interface z IP Address: Set IP Ad dress z Subnet Mask : Set the Subnet M ...

  • MicroNet Technology SP5050 - page 48

    48 1.2 H323 Information z Mode: Sel ect GK mode or Peer-to-Pe er mode z Gatekeep er IP Address: Set Gatekeeper IP Address z Gateway T y pe: Set Register T y pe to GK (Gatew ay / T erminal) z Register ed Prefix: Set Prefix N umber as E.16 4 number z Register ed Alias: Set Registered Alias as H323 ID z Gatekeeper Discover y , RTP Port, Ti me to Live ...

  • MicroNet Technology SP5050 - page 49

    49 1.3 Sy stem Config z Keyp ad T ype: Select different D TMF Keyp ad T ype (For Advanced U ser) z Dial Plan : Set DTMF digit limitatio n (0 is for any digits) z Inter Digit T ime: Set the DTMF inter digit time (second) z End of Dial: Digit t ype of end of dia ling. ( 0: No end of dialing, 1:[ *] butto n, 2:[#] button ) z 2nddial: This comm and is ...

  • MicroNet Technology SP5050 - page 50

    50 1.4 V oice Setting (For A dvanced User) z Frame Siz e: It got wrong order with “Code c Priority” . Select the Codec Priori ty . (For Adv anced User) z Codec Pri ority: It got wrong or der with “Fr ame Size” . Select the packet size i n sending proces s. (For Advanced User) z G .723 Si lence Sup pression: Enabl e / Disabl e (For Advanced ...

  • MicroNet Technology SP5050 - page 51

    51 1.5 Phone Pattern (For Adv anced User) ...

  • MicroNet Technology SP5050 - page 52

    52 1.6 Support Functions (Bot h side must support) z T. 3 8 : E n a b l e f o r T. 3 8 F A X z Fast S t art: Enable to d o Fast S t art z H.245 T unneling : Enable to open H.245 T unnel ing ...

  • MicroNet Technology SP5050 - page 53

    53 1.7 Phone Book (For Peer-to-Peer mode only ) Input the N ame, IP Address an d E.164 No. f or the d estination dev ice. Please Note: The E.164 No. will be carried together to the destina tion side. ...

  • MicroNet Technology SP5050 - page 54

    54 1.8 T ype Of Ser vice Adjust the parameter i n IP He ader for rou ter identity purpose. If t he version has PPPoE f unctio n, T oS i s not availabl e. ...

  • MicroNet Technology SP5050 - page 55

    55 1.9 Hot Lines Select HOST Port and set Destina tio n Address. T he Re mote Numbe r is subject to t he Destination’ s configurati on. ...

  • MicroNet Technology SP5050 - page 56

    56 1.10 PPPoE ...

  • MicroNet Technology SP5050 - page 57

    57 1.11 Password First select l ogin name as r oot or admini strator , then enter current passw ord , new p assword and co nfirm new p assword agai n. ...

  • MicroNet Technology SP5050 - page 58

    58 1.12 ROM Upgrade z TFTP S erver IP Addre ss: Set TFTP server IP address z T arge t File name: S et file n ame prepare d to upgra de z Method: S elect download method as TFTP or FTP z FTP S erver IP Address: Set F TP serv er IP ad dress z FTP L ogin: Set FTP login name a nd passw ord z T arget Fil e T ype: Selec t which sector of Gat eways to upg ...

  • MicroNet Technology SP5050 - page 59

    59 1.13 flash Cle an Press CLEAN will clean all con f igurations of Gatew ays and reset to factory default v alue. Once ex ecute this functi on, user must re-c onfigure all other commands ex cept IP Address. ...

  • MicroNet Technology SP5050 - page 60

    60 1.14 Commit Dat a After c onfiguratio n, user has t o commit dat a then reboot machine. It is an import ant step af ter every configuration. ...

  • MicroNet Technology SP5050 - page 61

    61 1.15 Reboot Sy stem After c ommit configuration, user has to REBOOT d evice. It is an imp o rtan t step aft er every configuration. ...

Fabricant MicroNet Technology Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilMicroNet Technology SP5050 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques MicroNet Technology
- manuels d’utilisations SP5050
- fiches produit MicroNet Technology
- dépliants
- ou étiquettes-énergie MicroNet Technology SP5050
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation MicroNet Technology SP5050.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation MicroNet Technology SP5050, manuels d’entretien, brefs manuels ou manuels de l’utilisateur MicroNet Technology SP5050. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit MicroNet Technology SP5050.

Manuel d’utilisation complet de l’appareil MicroNet Technology SP5050, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser MicroNet Technology SP5050 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs MicroNet Technology SP5050.

Le manuel d’utilisation complet MicroNet Technology, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel MicroNet Technology SP5050 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières MicroNet Technology SP5050, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMicroNet Technology SP5050 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil MicroNet Technology SP5050 - qui devraient nous aider dans les premières étapes lors de l'utilisation MicroNet Technology SP5050
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de MicroNet Technology SP5050
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service MicroNet Technology SP5050 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de MicroNet Technology SP5050?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec MicroNet Technology SP5050, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec MicroNet Technology SP5050 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)