    Moxa Industrial Video Encoder VPort 351 Series Quick Inst allation Guide Fifth Edition, June 2008 © 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited. Manual A m p l ic o n . co . u k I T a n d I n s t ru m en t a t io n f or i n du s tr y S al e s : + 4 4 (0 ) 1 27 3 57 0 2 20 W eb s i te : w ww . am p l i co n . ...

  • Moxa Technologies 351 - page 2

    - 2 - Overview The VPort 351 is a high performance, 1- channel industrial video encoder that provides up to full D1 (720 x 480) @ 30 FPS video performance. The VPort 351 is designed to support multi-c odecs, including MJPEG and MPEG4 algorithms. In addition, a continuous vide o pre/post event-tr igger video record function is supported to enhance v ...

  • Moxa Technologies 351 - page 3

    - 3 - y Built-in web server and RS-232 console for remote access & configuration y 1 auto-sensing 10/100BaseT(X) Ethernet por t or 100baseFX (SC connector) y TCP, UDP, and HTTP network transm ission modes y Allows simultaneous access of up to 10 clients y Set video quality to CBR (constant bit rate) or VBR (variable bit rate) y Full D1, 4CIF, V ...

  • Moxa Technologies 351 - page 4

    - 4 - VPort 351 Panel Layout VPort 351 Front Panel View VPort 351-M-SC Front Panel View 17 7 8 13 12 9 10 16 11 15 18 14 2 1 2 1 T op Panel View Rear Panel View 20 19 19 V1, V2: 12-32 VDC 12-30 VAC RS-232 CONSOLE 1 5 4 6 3 2 1. Grounding screw 2. RS-232 console port 3. Hardware reset button 4. 6-pin terminal block for DI 1, DI 2, power input 2 (PWR ...

  • Moxa Technologies 351 - page 5

    - 5 - First-Time Installation and Configuration Before installing the VPort 351 video enc oder, check to make sure that all items in the Package Checklis t are in the box. In addition, you will need to use a notebook or PC equipped with an Ethernet port. Step 1: Select the Power Source The VPort 351 can be powered by a DC power input from 12 to 32 ...

  • Moxa Technologies 351 - page 6

    - 6 - NOTE The PTZ control protocol is not standardized. To use a particular PTZ control protocol, the video server must support the driver for that protocol. Currently, the VPort 351 supports PTZ control protocol drivers for: 1. Pelco D 2. Pelco P 3. DynaColor DynaDome If you need to use a protocol that is not on the list, you will need to contact ...

  • Moxa Technologies 351 - page 7

    - 7 - NOTE You may download the VPort a nd Ether Device Configurator software from Moxa’s web site at www.moxa.com. 2. The Broadcast Search window will show a list of all switches and VPorts located on the network. The progress of the search will also be indicated. 3. When the search has ended, the Model Name, MAC address, and IP address of the E ...

  • Moxa Technologies 351 - page 8

    - 8 - Network Environment without DHCP Server If your VPort 351 is connected to a ne twork that does not have a DHCP server, then you will need to conf igure the IP address manually. The default IP address of the VPort 351 is 192.168.127.100 and the default subnet m a sk is 255.255.255.0. Note that you may need to change y our computer’s IP addre ...

  • Moxa Technologies 351 - page 9

    - 9 - Step 8: Accessing the Homepage of the VPort 351’s web-based manager After installing the ActiveX Control co mponent, the homepage of the VPort 351’s web-based manager will appear. Check the following items to make sure the system was installed properly: 1. Video Images 2. Audio Sound (make sure your PC’s or notebook’s sou nd is turned ...

  • Moxa Technologies 351 - page 10

    - 10 - NOTE After accessing the VPort 351’ s web-based manager, administrators should access System Configuration Æ System Æ Account to set up the administrator’s password and enable the authentication function. The admini strator account nam e is admin. An authentication window will pop up requesting the account name and password each time t ...

  • Moxa Technologies 351 - page 11

    - 11 - Mounting Dimensions (unit=mm) Rear View Side View Front View Wall Mounting Kit DlN-Rail Kit DlN-Rail Kit DlN-Rail 105.00 10 10 5 7.75 30.50 7.75 9.00 0 0 . 5 3 40.00 30.00 0 0 . 5 3 1 9 2 . 5 2 13 18 13 0 2 . 7 2 0 3 . 8 4 4 5 . 9 3 1 6 . 6 4 6 5 . 3 2 0 0 . 5 3 1 13.10 15.10 25.40 3.5 6 6 0 8 . 6 6 5 0 . 7 5 13.9 18.2 13.9 DIN-Rail Mounting ...

  • Moxa Technologies 351 - page 12

    - 12 - Wall Mounting (Optional) Follow the steps below to mount th e VPort 351 on a wall or panel. STEP 1 : Remove the aluminum DIN-Rail attachme nt plate from VPort 351, and then attach the wall mount plates, as shown in the diagrams below. ⇒ T op plate Bottom plate STEP 2 : Mounting the VPort 351 on the wall requires 4 screws. Use the VPort 351 ...

  • Moxa Technologies 351 - page 13

    - 13 - ATTENTION Safety First! Be sure to disconnect the power cord before installing and/or wiring your Moxa switch. This device has UL508 approval. Use copper conductors only, 60/75°C, Tighten To 4.5 pound-inches. For use in Pollution Degree 2 Environment. ATTENTION Safety First! Calculate the maximum possible current in each power wire and comm ...

  • Moxa Technologies 351 - page 14

    - 14 - Wiring the Redundant Power Inputs The VPort 351 has two power inputs, la beled PWR1 and PWR2, on the 6-pin and 8-pin terminal block connectors. Top and fr ont views of the terminal block connectors are shown in the following figures. A TTENTION The power for this product is intended to be supplied by a Listed Power Unit, with output marked L ...

  • Moxa Technologies 351 - page 15

    - 15 - Wiring the Digital Inputs The VPort 351 has two digital inputs, labele d DI1 and DI2. Each DI consists of two contacts of the 6-pin terminal bloc k connector located on the VPort’ s top panel. Top and front views of one of the terminal block connectors are shown here. PWR1 PWR2 PWR1 PWR2 V1- V1+ V2- V2+ V1- V1+ V2- V2+ STEP 1: Insert the n ...

  • Moxa Technologies 351 - page 16

    - 16 - RJ45 (10-pin) to DB9(F) Ca ble Wiring RJ45 Plug Pin 1 DCD DSR RTS GND TxD RxD CTS DTR DCD DTR CTS GND RxD TxD RTS DSR 1 2 3 4/7 5 6 8 9 1 6 7 5 3 2 8 4 RJ45 (10-pin) to DB25 (F) C able Wiring RJ45 Plug Pin 1 DCD DSR RTS GND TxD RxD CTS DTR DCD DTR CTS GND RxD TxD RTS DSR 1 2 3 4/7 5 6 8 9 8 6 4 7 2 3 5 20 10/100BaseT(X) Ethernet Port Connect ...

  • Moxa Technologies 351 - page 17

    - 17 - RJ45 (8-pin) to RJ45 (8-pi n) Straight-Through Cable Wiring Straight-Through Cable RJ45 Plug Pin 1 Switch Port RJ45 Connector RJ45 Connector Tx+ Tx- Rx+ Rx- VPort Ethernet Port Cable Wiring 3 3 6 6 1 1 2 2 Rx+ Rx- Tx+ Tx- RJ45 (8-pin) to RJ45 (8-pi n) Cross-Over Cable Wiring Cross-Over Cable RJ45 Plug Pin 1 NIC Port RJ45 Connector RJ45 Conne ...

  • Moxa Technologies 351 - page 18

    - 18 - LED Indicators Several LED indicators are located on the front panel of the VPort 351. The function of each LED is described in the table below. LED Color State Description ON Hardware initialization RED FLASH Software initialization ON System boot-up STAT GREEN FLASH Firmware upgrade proceeding On Power is being supplied to power input PWR1 ...

  • Moxa Technologies 351 - page 19

    - 19 - Hardware Reset A recessed RESET button is provided for restoring the system to the factory default settings. When the system fails to install properly, or operates abnormally, push the RESET button located on the top panel of the VPort 351 to restore the factory defaults. To restore the VPort 351 to the factory default settings, use a pointe ...

  • Moxa Technologies 351 - page 20

    - 20 - LED Indicators STAT Indicates if the system booted properly PWR1 Power 1 PWR2 Power 2 FAULT Can be configured to correspond to system alarm, power failure, video loss, or disconnected network VIDEO Video input signal active AUDIO TEST Audio input signal in test mode PTZ PTZ control signal active Power Input Two 12/ 24 VDC or 24 VAC for redun ...

  • Moxa Technologies 351 - page 21

    - 21 - Security y User level password protection y IP address filtering Recommended System Requirements y Pentium 4, 2.4 GHz or above y 512 MB memory or above y Windows XP/2000 with SP4 or above y Internet Explorer 6.x or above y DirectX 9.0c or above Software Bundled Free Moxa SoftDVR Lite 1- to 4-ch IP Surveillance Software for viewing & reco ...

Fabricant Moxa Technologies Catégorie Security Camera

Les documents que nous recevons du fabricant de l'appareilMoxa Technologies 351 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Moxa Technologies
- manuels d’utilisations 351
- fiches produit Moxa Technologies
- dépliants
- ou étiquettes-énergie Moxa Technologies 351
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Moxa Technologies 351.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Moxa Technologies 351, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Moxa Technologies 351. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Moxa Technologies 351.

Manuel d’utilisation complet de l’appareil Moxa Technologies 351, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Moxa Technologies 351 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Moxa Technologies 351.

Le manuel d’utilisation complet Moxa Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Moxa Technologies 351 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Moxa Technologies 351, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMoxa Technologies 351 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Moxa Technologies 351 - qui devraient nous aider dans les premières étapes lors de l'utilisation Moxa Technologies 351
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Moxa Technologies 351
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Moxa Technologies 351 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Moxa Technologies 351?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Moxa Technologies 351, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Moxa Technologies 351 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)