    CONTINUOUS FLOW ICEMAKER 500, 700, 1000, 2000 - Series Service Manual Release Date: May 27, 2004 Publication Number: 6304601 74SER Revision Date: Sept ember 24, 2008 Revision: D Visit the IMI Corn elius web site at www.cornelius .com for all your Liter ature needs. ® ...

  • Cornelius 1000 - page 2

    CONTINUOUS FLOW ICEMAKER SERVICE MANUAL The product s, technical information, and instr uctions conta ined in this manual are subject to change without notice. These instru ction s ar e not intended to co ver all details or varia- tions of the equipment, nor to provide for every possible contingency in the inst allation, operation or maintenance of ...

  • Cornelius 1000 - page 3

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - i - Publication Number: 630460174SER Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cornelius 1000 - page 4

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - ii - © 2004-2005, IMI Cornelius Inc. ...

  • Cornelius 1000 - page 5

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 1 - Publication Number: 630460174SER SAFETY S AFETY I NSTRUCTIONS Read and Follow all Safety Instructions Read and follow all safety instructio ns in this manual and on the machine (decals, labels, and laminated cards). Read and underst and all applicable OSHA (Occupation Sa ...

  • Cornelius 1000 - page 6

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 2 - © 2004-2005, IMI Cornelius Inc. GENERAL DESCRIPTION This section gives the Unit descripti on, theory of operation , and design d ata for continuous flow icemaker series 500, 700, 1000, and 2000. S PECIFICATION C HART NOTE: For u nits not li sted in abo ve chart, re fer ...

  • Cornelius 1000 - page 7

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 3 - Publication Number: 630460174SER FIGURE 1. SERIES 50 0 & 700 DIMENSION DR AWING (SHIPPING WT. 160 LBS. APPROX). FIGURE 2. SERIES 1000 DIMENSION DRAW ING (SHIPPING WT. 210 LBS. APPROX). 24.50 14.50 25.00 1.38 1.75 INLET 3/8 FLARED WA TER COOLED ONL Y OUTLET 3/8 FLRE W ...

  • Cornelius 1000 - page 8

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 4 - © 2004-2005, IMI Cornelius Inc. FIGURE 3. SERIES WCC2001-A AND WCF2201-A DIMENSION DRA WINGS VIEWED FROM BOTTOM OF MACHINE 30.00 24.00 28.06 AIR INLET SIDE FRONT BACK 2.06 2.25 23.50 18.13 W A TER IN ELECTRICAL 7/8 DIA. DRAIN 3/8 I.D. TUBE 9.50 20.13 3.81 ICE DISCHARGE ...

  • Cornelius 1000 - page 9

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 5 - Publication Number: 630460174SER B IN C ONTROL G EARMOTOR The gearmotor is equipped with a st art relay and a manual reset overload. When current is applied, the re lay energizes and completes th e circuit to the start winding. Th e motor reaches a predetermined speed an ...

  • Cornelius 1000 - page 10

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 6 - © 2004-2005, IMI Cornelius Inc. CLEANING AND SANITIZING I CEMAKER C LEANING AND S ANITIZING P ROCEDURES Do not use a ny of the ice ma de during clean ing operations. Clean and sanitize ice storage area when cleanin g icemaker . 1. Turn machine off. 2. Shut off water sup ...

  • Cornelius 1000 - page 11

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 7 - Publication Number: 630460174SER S EMI - ANNUALLY Semi–Annually in addition to all previously es tablished se rvice procedure s p erfo rm the following: 1. Check for water leaks in tube c onnections, water fittings and lower icemaker water seal. 2. Check drain tubes fo ...

  • Cornelius 1000 - page 12

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 8 - © 2004-2005, IMI Cornelius Inc. WATER LEVEL CONTROL H OW W ATER L EVEL C ONTROL W ORKS When water is intr oduced throug h the inlet fitting th e float rises. the floa t pushes again st a lever which in turn forces the poppet assembly against the inlet fi tting valve sea ...

  • Cornelius 1000 - page 13

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 9 - Publication Number: 630460174SER ELECTRICAL FIGURE 6. SCHEMATIC AND W IRING DIAGRAM WCC2001-A A ND WCF2201-A FIGURE 7. SCHEMATIC AND WIRING DIAGRAM WC C 500-A, WCC500-W, WCC700 -A, WCC700-W, WCF51 0-A, WCF510-W, WCF 710-A, & WCF710-W ...

  • Cornelius 1000 - page 14

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 10 - © 2004-2005, IMI Cornelius Inc. FIGURE 8. SCHEMATIC AND WIRING DIAGRAM WCC7 01-A, WCC701-W, WCC1001-A, WCC 1001-W, WCF711-A, WCF711-W, WCF1101-A , & WCF1101-W FIGURE 9. SCHEMATIC AND WI RING DIAGRAM WC F1101R, WCC1001R, WCF11 02R, & WCC1102R ...

  • Cornelius 1000 - page 15

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 11 - Publication Number: 630460174SER FIGURE 10. SCHEMATIC AND WIRING DIAGRAM WCC502, WCC702, WCC1002, WCF512, WCF 712, & WCF1102 FIGURE 11. SCHEMATIC AND WIRING DIAGRAM WCC2001-R AND WCF2201-R ...

  • Cornelius 1000 - page 16

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 12 - © 2004-2005, IMI Cornelius Inc. REFRIGERATION SYSTEM Thermostatic Expansion Valve NO Adjust ment. +/- 10 lbs. Discharge Press ure Water Temperature R EFRIGERATION S YSTEM A DJUSTMENTS A complete underst anding of the icemaker and hermetic refr igeration system is neces ...

  • Cornelius 1000 - page 17

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 13 - Publication Number: 630460174SER C ONDENSER M ODULATING V ALVE The reason for using a water modulating valve is to su p ply the correct amo unt of water to th e condense r . and to maint ain a proper operating pressure to refrig eration system high side. The flow of wat ...

  • Cornelius 1000 - page 18

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 14 - © 2004-2005, IMI Cornelius Inc. C ONDENSER M ODULATING V ALVE R EMOVAL 1. Disconn ect power t o unit, then s hut off water supply to condenser and evacuate refrigerant from system. 2. Remove inlet water line from Conden ser Modulating V a lve. Also remove tube from hig ...

  • Cornelius 1000 - page 19

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 15 - Publication Number: 630460174SER M OTOR C HECK The resistance readings on the winding will be between 5 to 25 ohms. A meter capable of these low readings must be used. The st art relay cover must be removed. If no continuity on start or run windin g test, repl ace gearm ...

  • Cornelius 1000 - page 20

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 16 - © 2004-2005, IMI Cornelius Inc. I NSTALLATION AND S HAFT S EAL R EPLACEMENT 500 A UGER AND E XTRUDING H EAD R EMOVAL 1. Disconn ect unit fro m power supp ly . 2. Remove storage cont ainer cover and put aside. 3. Turn off water supply to icemake r . 4. After ice has me ...

  • Cornelius 1000 - page 21

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 17 - Publication Number: 630460174SER I NSTALLATION AND S HAFT S EAL R EPLACEMENT 700 & 1000 U PPER N UT AND B EARING A SSEMBLY The upper white bea ring located on top of the au ger is used to absorb the force between the auger and extruding head. NOTE: The bearings are ...

  • Cornelius 1000 - page 22

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 18 - © 2004-2005, IMI Cornelius Inc. O VERLOAD C HECK C OMPRESSOR C HECK C APACITOR C HECK Using a volt–ohmmeter check the continuity across the overload , cont act #1 and #3. If none, wait for unit to cool down and try again. If still no continuity , the overload pr ot e ...

  • Cornelius 1000 - page 23

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 19 - Publication Number: 630460174SER S AFETY C ONTROLS Y our icemaker unit has several safety and contro l devices incorporated into it s design. W ARNING: None of the below described devices should ever be “byp assed” to allow the unit to function. The safety and contr ...

  • Cornelius 1000 - page 24

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 20 - © 2004-2005, IMI Cornelius Inc. GUIDE T O GOOD ICE CUSTOMER COMMENTS CHECK ICEMAKER LOCA TION CONDITIONS FIRST CHECK ICE MAKER Use gauges for checking suction and head pressures. See manual for correct reading and conditions. Check frost line and sight glass. Check wat ...

  • Cornelius 1000 - page 25

    Continuous Flow Icemaker Service Manual © 2004-2005, IMI Cornelius Inc. - 21 - Publication Number: 630460174SER TROUBLESHOOTING TROUBLESHOO TING CHART - ICEMAKER NO T OPERA TING NO POWER Check electrical wiring in con trol box f or loose connec tions. Check f or failed service switch or rela y . Check pow er to machine. ICEMAKER RUNS B UT DOES NOT ...

  • Cornelius 1000 - page 26

    Continuous Flow Icemaker Service Manual Publication Number: 630460174SER - 22 - © 2004-2005, IMI Cornelius Inc. ...

  • Cornelius 1000 - page 27

    IMI Corneliu s Inc. www.cornel ius.com ...

Fabricant Cornelius Catégorie Juicer

Les documents que nous recevons du fabricant de l'appareilCornelius 1000 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cornelius
- manuels d’utilisations 1000
- fiches produit Cornelius
- dépliants
- ou étiquettes-énergie Cornelius 1000
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cornelius 1000.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cornelius 1000, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cornelius 1000. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cornelius 1000.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Cornelius 1000, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cornelius 1000 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cornelius 1000.

Le manuel d’utilisation complet Cornelius, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cornelius 1000 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cornelius 1000, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCornelius 1000 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cornelius 1000 - qui devraient nous aider dans les premières étapes lors de l'utilisation Cornelius 1000
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cornelius 1000
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cornelius 1000 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cornelius 1000?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cornelius 1000, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cornelius 1000 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)