Manuel d’utilisation Raritan CommandCenter CC-SG

58 pages 1.12 mb
Télécharger

Aller à la page of 58

Summary
  • Raritan CommandCenter CC-SG - page 1

    CommandCenter ® Secure Gateway CC-SG User Guide Release 3.1.1 Copyright © 2007 Raritan, Inc. CC-0M-E April 2007 255-80-3100 ...

  • Raritan CommandCenter CC-SG - page 2

    This page intenti onally left blank ...

  • Raritan CommandCenter CC-SG - page 3

    Copyright and Tradem ark Information This document contains proprietary information that is protected by copyright. All rights reserved. No part of this document may be phot ocopied, reproduced, or tr anslated into another language without express prior written consent of Raritan, Inc. © Copyright 2007 Raritan, CommandCenter, Ra ritanConsole, Domi ...

  • Raritan CommandCenter CC-SG - page 4

    Safety Guidelines To avoid potentially fatal shock hazard a nd possible damage to Raritan equipm ent: • Do not use a 2-wire power cord in any product configuration. • Test AC outlets at your computer and monitor for proper polarity and ground ing. • Use only with grounded outlets at both the computer and monitor. When using a backup UPS, powe ...

  • Raritan CommandCenter CC-SG - page 5

    C ONTENTS i Content s Chapter 1: Introduction ....................................................................................................1 Prerequisites ............................................................................................................... 1 Terminology/Acronyms ..................................................... ...

  • Raritan CommandCenter CC-SG - page 6

    ii C ONTENTS Add a new cu stom view .......................................................................................................... ......... 42 Apply a cust om view ............................................................................................................ ............ 43 Change a cust om view .......................... ...

  • Raritan CommandCenter CC-SG - page 7

    F IGURES iii Figur es Figure 1 CC-SG Directo r Client Logi n Screen.................................................................................... .......... 4 Figure 2 CC-SG Director Client Home Screen ..................................................................................... ........ 5 Figure 3 Access Cli ent Login Screen ........ ...

  • Raritan CommandCenter CC-SG - page 8

    This page intenti onally left blank ...

  • Raritan CommandCenter CC-SG - page 9

    C HAPTER 1: I NTRODUCTION 1 Chapter 1: Introduction This document is intended for users who have been granted the Nodes Access privilege and have access to particular nodes that are attached to Raritan devices or IPMI servers. With the Nodes Access privilege, you can connect to nodes, control po wer to nodes, create cu stom views, search for nodes, ...

  • Raritan CommandCenter CC-SG - page 10

    2 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE This page intenti onally left blank ...

  • Raritan CommandCenter CC-SG - page 11

    C HAPTER 2: A CCESSING CC-SG 3 Chapter 2: Accessing CC-SG You can access CC-SG in two ways, each described in this chapter: • Through a browser: CC-SG supports numerous Web browsers. For a com plete list of browsers and platforms, please re fer to the Compatibility Matrix on http://www.raritan.com/support . Click Firmware Upgrades, then CommandCe ...

  • Raritan CommandCenter CC-SG - page 12

    4 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Browser-Based Access via t he CC-SG Director Client The CC-SG Director client is a Java-based c lient provides a GUI for both ad ministrative and access tasks, depending on your permissions. 1. Using a supported Internet browser, type the URL of t he CC-SG, and then type /admin: https://<IP addres ...

  • Raritan CommandCenter CC-SG - page 13

    C HAPTER 2: A CCESSING CC-SG 5 6. Upon valid login, the CC-SG application window appears. Figure 2 CC-SG Director Client Home Screen ...

  • Raritan CommandCenter CC-SG - page 14

    6 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Browser Based Access via the CC-SG Access Client The CC-SG Access client is an HTML-based clie nt provides a GUI for access tasks, depending on your permissions. 1. Using a supported Internet browser, type the URL of the CC-SG: https://<IP address> . For example, https://10.0.3.30 . The login s ...

  • Raritan CommandCenter CC-SG - page 15

    C HAPTER 2: A CCESSING CC-SG 7 5. Upon valid login, the CC-SG Access Client’s Home screen appears. Figure 4 CC-SG Access Client’s Home Screen Possible Error Message in Internet Explorer If you are using Internet Explorer, and you have access to a large number of nodes, you may see the following error message while CC-SG loads: A script on this ...

  • Raritan CommandCenter CC-SG - page 16

    8 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Thick Client Access The CC-SG thick client allows you to conn ect to CC-SG by launching a Java Web Start application instead of running an applet through a web browser. The advantage of using the thick client instead of a browser is that the client can outperform the browser in te rms of speed and ef ...

  • Raritan CommandCenter CC-SG - page 17

    C HAPTER 2: A CCESSING CC-SG 9 8. The login screen appears, and the thick client looks and behaves just like the browser-based Java client. If the Restricted Service Agreement is enabled, read the agreement text, and then check the I Understand and Accept the Restricted Service Agr eement checkbox. 9. Type your Username and Password in the correspo ...

  • Raritan CommandCenter CC-SG - page 18

    10 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE CC-SG Director Cli ent Window Components Figure 6 CC-SG W indow Components 1. Nodes Selection tab : Click the Nodes tab to display all nodes in a tree view. In terfaces are grouped under their parent nodes. Click the + and - signs to expand or collapse the tree. Click a node to view the Node Profile ...

  • Raritan CommandCenter CC-SG - page 19

    C HAPTER 2: A CCESSING CC-SG 11 CC-SG Access Client Window Components Figure 7 CC-SG Access Client Components 1. User ID and Date : Your CC-SG system date and time and User ID display at the top of the left panel. Click the User ID hyperlink to open the My Profile tab. 2. Search : The Search function allows you to search for nodes in two ways. 3. N ...

  • Raritan CommandCenter CC-SG - page 20

    12 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE This page intenti onally left blank ...

  • Raritan CommandCenter CC-SG - page 21

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 13 Chapter 3: Connecting to and Using Nodes via the CC-SG Director Client Nodes are the target systems, su ch as servers, desktop PCs, or other networked equipment, that CC-SG users can access. When you click the Nodes tab, the Nodes tree displays in formation about th ...

  • Raritan CommandCenter CC-SG - page 22

    14 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE About Interfaces Each node has one or more interfaces thr ough which you can conne ct to the node. To view the interfaces associated with a node Select a node in the Nodes tab to open the Node Profile. All interfaces associated with the node are listed in the Interfaces section. To check an interfac ...

  • Raritan CommandCenter CC-SG - page 23

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 15 4. The RSC application launches in a new window . Use the application to manage the node. Figure 10 Raritan Serial Console 5. When you are finished using RSC to manage the node, on the RSC Emulator me nu, click Exit . 6. Repeat the steps in this section to connect t ...

  • Raritan CommandCenter CC-SG - page 24

    16 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Connect to a Node via an Ou t-of-Band KVM Interface 1. In the Nodes tree, select the node you want to connect to and manage. The Node Profil e screen appears. Figure 11 Node Profile Screen, Out-of-Band KVM Interface 2. In the Node Profile screen, all configured interfaces display in the Interfaces s ...

  • Raritan CommandCenter CC-SG - page 25

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 17 Figure 13 Multi-Platform Client Window Note : If using the MPC application, saving the user profile from MPC also saves it to CC-SG. Thereafter, when connecting to a node using MP C, the saved settings are applied to the MPC session. Figure 14 Virtual KVM Client Win ...

  • Raritan CommandCenter CC-SG - page 26

    18 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE 7. Repeat the steps in this section to connect to and m anage other nodes via KVM interfaces. Note : If the KVM node is on sleep mode and indicat es “no video signal,” press the space bar on your keyboard until the no de exits sleep mode. Connect to a Node via an In-Band KVM Interface 1. In the ...

  • Raritan CommandCenter CC-SG - page 27

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 19 5. When you are finished using Remote Console , close the browser window. 6. Repeat the steps in this sec tion to connect to and manage other nodes via in-band KVM interfaces. Managing Node Power via an In-Band Power Interface You can power on, power off, recycle po ...

  • Raritan CommandCenter CC-SG - page 28

    20 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE 5. In the Available list, select the power interface through which you want to perform power control for the node, and then click Add to m ove the interface to the Selected list. 6. Click the Operation drop-down arrow, and select Power On , Power Off , Power Cycle , or Graceful Shutdown from the lis ...

  • Raritan CommandCenter CC-SG - page 29

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 21 7. If you selected Power On or Power Off in the Operation field and more than one interface in the Selected list, type the number of seconds, from 0-120, that should elapse between interfaces in the Sequence Interval (seconds) field. 8. Click OK to begin the power c ...

  • Raritan CommandCenter CC-SG - page 30

    22 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE • Nodes are arranged alphabetically by name. • Interfaces are grouped under their parent no des. Click the + and - signs to expand or collapse each grouping. • Click the Expand Tree and Collapse Tree icons in the toolbar at the top of the screen to expand and collapse the entire tree. Custom V ...

  • Raritan CommandCenter CC-SG - page 31

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 23 Add Custom View 1. Click the Nodes tab. 2. On the Nodes menu click Change View, and then c lick Create Custom View . The Custom View screen appears. 3. In the Custom View panel, click Add . The Add Custom View window appears. Figure 22 Add Custom View Window 4. Type ...

  • Raritan CommandCenter CC-SG - page 32

    24 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE 5. Type a new name for the custom view in the Enter new name for custom view field, and then click OK . The new view name appears in the Name field in the Custom View screen. 6. If you want to add more categories to the custom view, click the Category name drop-dow n arrow at the bottom of the panel ...

  • Raritan CommandCenter CC-SG - page 33

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 25 Power Control for Nodes Single Interface Power Control You can quickly select the power operation you want to perform on a specific power control interface by using the interface’s right-click menu. 1. In the Nodes tree, right-click the interface you want to contr ...

  • Raritan CommandCenter CC-SG - page 34

    26 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Single Node Power Control You can power on, power off, cycle power, and perf orm graceful shutdown to a single no de that has an associated power interface. 1. Click the Nodes tab. 2. Select the node that you want to perform power control on. 3. On the Nodes menu, click Power Control . The Power Con ...

  • Raritan CommandCenter CC-SG - page 35

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 27 Node Group Power Control You can power on, power off, cycle power, and perform graceful shutdown for all nodes in a node group that has associated power interfaces. Th is might be useful if you needed to power down all nodes in a node group so that you can rewire th ...

  • Raritan CommandCenter CC-SG - page 36

    28 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Node Chat Chat provides a way for users connected to the same node to communicate with each other. You must be connected to a node to start a chat ses sion for that node. Only users on the same node will be able to chat with each other. To engage in a chat session: 1. Click the Nodes tab. 2. Right-c ...

  • Raritan CommandCenter CC-SG - page 37

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 29 About Searching for Nodes The CC-SG Search function allows you to search for nodes that match y our search terms. CC-SG offers two search types, Filter by Search Results and Find Matching String . • Filter by Search Results allows you to type search terms, and the ...

  • Raritan CommandCenter CC-SG - page 38

    30 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Supported Wildcards for Node Search These wildcards are supported when you have Filter by Search Results set as your search preference in My Profile. Please ref er to Change My Profile, Set Search Pref erence for additional information on search preferences. W ILDCARD D ESCRIPTION ? Indicates any ch ...

  • Raritan CommandCenter CC-SG - page 39

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG D IR ECTOR C LIEN T 31 Change My Profile My Profile allows you to change your CC-SG password and email address, adjust the CC-SG display’s font size, and set your default search ty pe preference. You can also view information about how long you can use your password until you will be fo ...

  • Raritan CommandCenter CC-SG - page 40

    32 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE 5. Click OK to set your new password. Change Your Email Address 1. On the Secure Gateway menu, click My Profile . The Change My Profile screen appears. 2. Type your new email address in the Email address field, and then click OK. Change the CC-SG Font Size CC-SG will use the font size you select for ...

  • Raritan CommandCenter CC-SG - page 41

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 33 Chapter 4: Connecting to and Using Nodes Via the CC-SG Access Client In the CC-SG Access Client, you can connect to nodes through their associated interfaces. Each node has a Node details screen, which lists all associated interfaces to which you have access. If a node ...

  • Raritan CommandCenter CC-SG - page 42

    34 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Connect to a Node via an Out- of-Band Serial Interface 1. Select the node you want to connect to and manage in one of the node lists in the left panel. The Node details screen appears. Figure 30 Node Profile Screen—Out-of-Band Se rial Interface 2. In the Node details screen, all configured interfa ...

  • Raritan CommandCenter CC-SG - page 43

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 35 Connect to a Node via an Ou t-of-Band KVM Interface 1. In the Nodes tree, select the node you want to conn ect to and manage. The Node details screen appears. Figure 32 Node Profile Screen—Out-of-Band KV M Interface 2. In the Node details screen, all configured interf ...

  • Raritan CommandCenter CC-SG - page 44

    36 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Figure 34 Multi-Platform Client Window Note : If using the MPC application, saving the user profile from MPC also saves it to CC-SG. Thereafter, when connecting to a node using MP C, the saved settings are applied to the MPC session. Figure 35 Virtual KVM Client Window 6. When you are finished using ...

  • Raritan CommandCenter CC-SG - page 45

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 37 7. Repeat the steps in this section to connect to and m anage other nodes via KVM interfaces. Note : If the KVM node is on sleep mode and indicat es “no video signal,” press the space bar on your keyboard until the no de exits sleep mode. Connect to an iLO/RILOE-Ena ...

  • Raritan CommandCenter CC-SG - page 46

    38 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Managing an iLO/RILOE Power Interface Please refer to Power Control for Nodes for additional information on managing power interfaces. Note : Nodes of an iLO/RILOE device are powered on/off and recycled directly. Nodes connected to Raritan Dominion devices, such as KX and SX, are managed via outlets ...

  • Raritan CommandCenter CC-SG - page 47

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 39 5. Click the Operations drop-down arrow, and select On , Off , Cycle , or Graceful Shutdown from the list. 6. If you selected multiple interfaces, type the num ber of seconds, from 0-120, that should elapse between interfaces in the Sequence Interval (seconds) field. 7. ...

  • Raritan CommandCenter CC-SG - page 48

    40 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Node Lists The left panel of the CC-SG HTML Client contains several ways to locate nodes. There are three lists that offer different views of the nodes: All Nodes , Favorites and Recent . In each list, you see icons that show the status of each node. You can click a node in one of the lists to open ...

  • Raritan CommandCenter CC-SG - page 49

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 41 Sort Nodes in Favorites You can change the order in which nodes are listed in the Favorites tab. 1. Click the Favorites list in the left panel. Figure 39 Favorites List 2. Click Sort . The Sort Favorites window appears. Figure 40 Sort Favorites Window 3. You must put th ...

  • Raritan CommandCenter CC-SG - page 50

    42 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE Recent Nodes List The Recent list displays the ten nodes you have mo st recently accessed by clicking the node name in any list. Each node you visit is added to the top of t he Recent list. Clear the Recent Nodes List 1. Click the Recent list in the left panel. Figure 41 Recent List 2. Click Clear A ...

  • Raritan CommandCenter CC-SG - page 51

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 43 7. Click Save to save the new custom view. Apply a custom view 1. Click the Custom View tab. 2. Click the View Name drop-down arrow and select from the list the custom view you want to apply to the All Nodes list. 3. Click Apply View to sort the All Nodes list according ...

  • Raritan CommandCenter CC-SG - page 52

    44 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE 2. Click the View Name drop-down arrow and select the custo m view you want assign as a system-wide default view. 3. Check the System View checkbox, and then click Save . All users who log in to CC-SG will see the A ll Nodes list sorted according to the Categories specified in the selected custom vi ...

  • Raritan CommandCenter CC-SG - page 53

    C HAPTER 3: C ONNECTING T O AND U SING N ODES V IA THE CC-SG A CCESS C LIENT 45 My Profile The My Profile tab allows you to change your password, email address, and default node list. Change Your Password The Change Password section of My Profile allows you to change your CC-SG password. 1. Click the My Profile tab. The My Profile screen opens 2. C ...

  • Raritan CommandCenter CC-SG - page 54

    46 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE This page intenti onally left blank ...

  • Raritan CommandCenter CC-SG - page 55

    C HAPTER 5: G ENERATING R EPORTS 47 Chapter 5: Generating Reports You can generate reports only from the Dir ector Client, not from the Access Client. Note : In all reports, use CTRL+click to deselect a highlighted row. Active Nodes Report The Active Nodes report displays ports that are cu rrently in use. You can view the connections and disconnect ...

  • Raritan CommandCenter CC-SG - page 56

    48 C OMMAND C ENTER S ECURE G ATEWAY U SER G UIDE User Data Report The User Data report displays certain data on all users in the CC-SG database. From User Name field you can see names of users currently in session. From Phone field you can see user dial back telephone number. Form Enabled field you can see information if check box Login is enabled ...

  • Raritan CommandCenter CC-SG - page 57

    A PPENDIX A: K EYBO ARD S HORTCUTS 49 Appendix A: Keyboard Shortcuts The following keyboard shortcuts can be used in the Java-based Director Client. O PERATION K EYBOARD S HORTCUT Refresh F5 Print panel Ctrl + P Help F1 255-80-3100 ...

  • Raritan CommandCenter CC-SG - page 58

    North Amer ican Headquarte rs Raritan 400 Cottontail Lane Somerset, NJ 08873 U.S.A. Tel. (732) 764-8886 or (800) 724-8090 Fax (732) 764-8887 Email: sales@raritan.com Website: Raritan.com Raritan NC 4901 Waters Edge Dr. Suite 101 Raleigh, NC 27606 Tel. (919) 277-0642 Email: sales.nc@raritan.com Website: Raritan.com Raritan Canada 4 Robert Speck Pkwy ...

Fabricant Raritan Catégorie Network Router

Les documents que nous recevons du fabricant de l'appareilRaritan CommandCenter CC-SG peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Raritan
- manuels d’utilisations CommandCenter CC-SG
- fiches produit Raritan
- dépliants
- ou étiquettes-énergie Raritan CommandCenter CC-SG
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Raritan CommandCenter CC-SG.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Raritan CommandCenter CC-SG, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Raritan CommandCenter CC-SG. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Raritan CommandCenter CC-SG.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Raritan CommandCenter CC-SG, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Raritan CommandCenter CC-SG par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Raritan CommandCenter CC-SG.

Le manuel d’utilisation complet Raritan, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Raritan CommandCenter CC-SG - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Raritan CommandCenter CC-SG, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRaritan CommandCenter CC-SG qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Raritan CommandCenter CC-SG - qui devraient nous aider dans les premières étapes lors de l'utilisation Raritan CommandCenter CC-SG
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Raritan CommandCenter CC-SG
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Raritan CommandCenter CC-SG dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Raritan CommandCenter CC-SG?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Raritan CommandCenter CC-SG, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Raritan CommandCenter CC-SG il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)