Manuel d’utilisation Friedrich WY13B33A-B

30 pages 0.83 mb
Télécharger

Aller à la page of 30

Summary
  • Friedrich WY13B33A-B - page 1

    WS08B10A-C WS10B10A-C WS14B10A-C WS10B30A-C WS13B30B-C WS16B30A-C WE10B33A-B WE13B33B-B WE16B33A-B WY10B33A-B WY13B33A-B WM-Svc-Prts-07 (3-07) Ser vi ce & P ar ts Manu al W allMaster ® Thru-the-W all T e m p / H o u r Cool Money Saver ® F a n O n ly Clock Start Time Stop Time P o w e r F a n S p e e d M o d e P M T im e r O n / Off S e t H o ...

  • Friedrich WY13B33A-B - page 2

    2 T ABLE OF CONTENTS W arranty ...................................................................................................................... ...............................3 Routine Maintenance ................................................................................................................................4 Unit Identi fi c ...

  • Friedrich WY13B33A-B - page 3

    3 Friedrich Air Conditioning Company P.O. Box 1540 San Antonio, TX 78295 210.357.4400 www.fr iedrich.com WALLMASTER £ THRU-THE-WALL AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR A NY PART: If any part supplied by FRIEDRICH fails because of a defect in workmanship or material within twelve months from date of original purchase, FRIEDRICH will repair ...

  • Friedrich WY13B33A-B - page 4

    4 ROUTINE MA INTEN ANCE NOT E : Un its are to be inspect ed and ser viced by quali fi ed ser vice per sonnel only . Inspect the indoor blower housing, evap orator blade, condenser fan blade, and c o ndenser shroud perio dically (yearly or bi-yearl y ) and clean of all debr is (lint, dir t, mold, fungus, etc. ) Clean the blower housing area and blo ...

  • Friedrich WY13B33A-B - page 5

    5 FRIEDRICH ROOM MODEL NUMBER CODE W S 08 B 1 0 B 1st DIGIT - FUNCTION W = Thru-The-W all, W allMaster Series 2nd DIGIT - TYPE S = Straight Cool E = Electric Heat Y = Heat Pump 3rd & 4th DIGITS - APPROXIMA TE BTU/HR (Cooling) Heating BTU/HR capacity listed in Speci fi cations/Performance Data Section 5th DIGIT - ALPHABETICAL MODIFIER 6th DIGIT ...

  • Friedrich WY13B33A-B - page 6

    6 * Rat ing C ondi ti ons: 80 d eg ree s F , ro om air t emp. & 50 % rel ati ve humi dit y, wit h 95 deg r ee F , ou tsi de air t emp & 40 % rel ati ve hu midi t y P ERF ORMANCE D A T A Cal culat e the h eat l oss o f the sp ace t o be he ate d. A s long as t he he at los s doe s not e xce ed th e resis t ance h eat ing cap aci t y rat ing ...

  • Friedrich WY13B33A-B - page 7

    7 Wire Size Use O NL Y w iring size reco mmended for single outlet branch circuit. F use/Circuit Use O NL Y t ype and size fuse or H ACR Bre ak er circuit breaker indicated on unit ’ s rating plate . Proper current protection to the unit is the responsibilit y of the ow ner . G r o u n d i n g U n i t M U S T b e g r o u n d e d f r o m b r a n c ...

  • Friedrich WY13B33A-B - page 8

    8 FUNCT IONAL COMPONENTS A. Me ch a ni ca l c o m po n e n ts Bellows condens ate valv e T emperature - sensitive valve tha t opens up to drain of f cond ensate water when the outside temperature falls below 40 °F and closes when t he outside temperature reaches 5 8°F . Plenum assemb ly Dif f user with direc tional louvers used to direct t he con ...

  • Friedrich WY13B33A-B - page 9

    9 SYSTEM CONTROL P ANEL (“WS” Models) CHECKING ROOM TEMPERA TURE 1 . Check the ro om temperature at the electronic c ontrol pad b y pressing at the sa me time the “F AN SPEED” button and t he temperature “UP” but ton on XQ & WS models . 2. The indoor temperature wi ll display for 1 0 seconds. Indoor temperature can be viewed in all ...

  • Friedrich WY13B33A-B - page 10

    10 SYSTEM CONTROL SWITCH - TEST Disconnect leads from control switch. T urn control to posi- tion being tested (see Figure 8). There must be continuity as follows: 1. “Of f” Position-no continuity between terminals. 2. “Lo Cool” Position-between terminals “C” and “3”, “C2” and “2”, “LO” and “M/S”, “AR” and “5? ...

  • Friedrich WY13B33A-B - page 11

    11 IMPORT ANT ANY SE A LED S YSTE M REP AIRS T O COO L - ONL Y MOD ELS REQUIRE THE I NST ALL A TIO N OF A L I Q U I D L I N E D R I E R . A L S O , A N Y S E A L E D S Y S T E M R E P A I R S T O H E AT P U M P M O D E L S R E Q U I R E T H E INST ALL A TION O F A SUCTION LIN E DRIER . the ev aporator coil. As it enters the ev aporator coil, the la ...

  • Friedrich WY13B33A-B - page 12

    12 SEALED REFRIGERA TION SYSTEM REP AIRS EQUIPMENT REQUIRED: 1. V oltmeter 2. Ammeter 3. Ohmmeter 4. V acuum Pump (capable of 200 microns or less vacuum.) 5. Acetylene Welder 6. Electronic Halogen Leak Detector (G.E. T ype H-6 or equivalent.) 7. Accurate refrigerant charge measuring device such as: a. Balance Scales - 1/2 oz. accuracy b. Charging B ...

  • Friedrich WY13B33A-B - page 13

    13 10. Evacuate system to maximum absolute holding pres- sure of 200 microns or less. NOTE: This process can be speeded up by use of heat lamps, or by breaking the vacuum with refrigerant or dry nitrogen at 5,000 microns. Pressure system to 5 PSIG and leave in system a minimum of 10 minutes. Release refriger- ant, and proceed with evacuation of a p ...

  • Friedrich WY13B33A-B - page 14

    14 NORMAL F UNC TION OF V AL VE VA LV E OPERA TING COND ITI ON DISCHARGE TUBE from Com presso r SUCT IO N TUB E to Compr essor Tu b e t o I N S I D E COIL Tu b e t o O U T S I D E COIL LEFT Pilot Capillary T ube RIGHT Pilot Capillary T ube NO TES : * TEM PER A TURE O F V AL VE BO DY ** WAR M ER THA N VAL VE BO D Y 1 2 3 4 5 6 POSSIBL E C A US ES CO ...

  • Friedrich WY13B33A-B - page 15

    15 COOLING ONL Y ROOM AIR CONDIT IONERS : TROUBLESHOOT ING TIPS Problem Possible Cause Action Compressor does not run Low voltage Check voltage at compressor . 1 15V & 230V units will operate at 10% voltage variance T -stat not set cold enough or inoperative Set t-stat to coldest position. T est t-stat & re- place if inoperative Compressor ...

  • Friedrich WY13B33A-B - page 16

    16 Problem Possible Cause Action Unit does not run Fuse blown or circuit tripped Replace fuse, reset breaker . If repeats, check fuse or breaker size. Check for shorts in unit wiring & components Power cord not plugged in Plug it in System switch in "OFF" position Set switch correctly Inoperative system switch T est for continuity in ...

  • Friedrich WY13B33A-B - page 17

    17 Problem Possible Cause Action Compressor runs for short periods only . Cycles on overload Overload inoperative. Opens too soon Check operation of unit. Replace overload if system operation is satisfactory Compressor restarted before system pressures equalized Allow a minimum of 2 minutes to allow pressures to equalize before attempting to restar ...

  • Friedrich WY13B33A-B - page 18

    18 Problem Possible Cause Action W ater "spitting" into room Sublimation: When unconditioned saturated, outside air mixes with conditioned air , condensation forms on the cooler surfaces Ensure that foam gaskets are installed in between window panes & in between the unit & the sleeve. Also, ensure that fresh air/exhaust vents (on ...

  • Friedrich WY13B33A-B - page 19

    19 HE A T / COOL ROOM AIR CONDIT IONERS: TROUBLESHOOTING TIP S Problem Possible Cause Action Room temperature uneven (Heating cycle) Heat anticipator (resistor) shorted (on applicable models) Disconnect power to unit. Remove resistor from t-stat bulb block. Plus in unit & allow to operate. Feel resistor for heat. If not heat, replace resistor W ...

  • Friedrich WY13B33A-B - page 20

    20 Problem Possible Cause Action Unit cools when heat is called for Incorrect wiring Refer to applicable wiring diagram Defective solenoid coil Check for continuity of coil Reversing valve fails to shift Block condenser coil & switch unit to cooling. Allow pressure to build up in system, then switch to heating. If valve fails to shift, replace ...

  • Friedrich WY13B33A-B - page 21

    21 WIRING DIAGRAM: MODELS WS08B10A-C, WS10B10A-C, WS14B10A-C, WS10B30A-C, WS13B30C ...

  • Friedrich WY13B33A-B - page 22

    22 WIRING DIAGRAM: MODELS WS16B30A-C ...

  • Friedrich WY13B33A-B - page 23

    23 WIRING DIAGRAM: MODELS WE10B33A-B, WE13B33B-B ...

  • Friedrich WY13B33A-B - page 24

    24 WIRING DIAGRAM: MODELS WE16B33A-B ...

  • Friedrich WY13B33A-B - page 25

    25 WIRING DIAGRAM: MODELS WY10B33A-B, WY13B33A-B ...

  • Friedrich WY13B33A-B - page 26

    26 WS, WE & W Y SERIES CH ASSIS P ARTS 47 48 46 46A 31 12 32 30 7 16 17 14 20 18 19 27 25 13 8 For Heat & Cool Models Only 5 45 26 1 41 43 39 Electronic Control Box and Controls 2 41 39 43 6 1 44 Electro Mechanical Control Box and Controls ...

  • Friedrich WY13B33A-B - page 27

    27 * Part Not Shown REF DESCRIPTION P ART NO. 1 15V 230V CODE ELECTRICAL P ARTS WS08B10A-C WS10B10A-C WS14B10A-C WS10B30A-C WS13B30B-C WS16B30A-C WE10B33A-B WE13B33B-B WE16B33A-B WY10B33A-B WY13B33A-B 1 ELECTRONIC BOARD 61921 198 1 1 1 331 1 ELECTRONIC BOARD 61921 199 1 1 1 331 * REMOTE CONTROL 61826606 1 1 1 1 1 1 350 1 THERMOST A T 25043302 1 1 1 ...

  • Friedrich WY13B33A-B - page 28

    28 W ALLMASTER P A RTS 20 07 * Part Not Shown REF DESCRIPTION P ART NO. 1 15V 230V CODE CHASSIS P ARTS WS08B10A-C WS10B10A-C WS14B10A-C WS10B30A-C WS13B30B-C WS16B30A-C WE10B33A-B WE13B33B-B WE16B33A-B WY10B33A-B WY13B33A-B 16 SHROUD, CONDENSER 62102000 1 1 1 1 1 1 1 1 1 1 1 720 17 F AN BLADE, COND. 62101500 1 1 1 1 1 1 1 1 1 1 1 710 18 BLOWER WHEE ...

  • Friedrich WY13B33A-B - page 29

    29 WS - WE - W Y SE RIES SLEE V E P ARTS WS, WE & WY SERIES SLEEVE P ARTS 2 3 4 1 REF DESCRIPTION P ART NO. 1 SLEEVE ASSEMBL Y 61603611 1 1 111111111 2 P ANEL, WEA THER INNER 61603201 1 1 111111111 3 GRILLE, LOUVERED 6160301 1 1 1 111111111 4 P ANEL, WEA THER OUTER 61603303 1 1 111111111 ...

  • Friedrich WY13B33A-B - page 30

    WM-Svc-Prts-07 (3-07) F rie drich Air Condition ing Co. Post Of f ice Box 15 4 0 • San A ntonio, T exa s 782 95 - 15 4 0 420 0 N. Pa n Am Expr e ss way • San Ant onio, T exas 78 218 - 5212 (210) 357 - 4 4 0 0 • F A X (210) 357 - 4 4 8 0 w w w. fried rich.co m Printe d in th e U .S.A . ...

Fabricant Friedrich Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilFriedrich WY13B33A-B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Friedrich
- manuels d’utilisations WY13B33A-B
- fiches produit Friedrich
- dépliants
- ou étiquettes-énergie Friedrich WY13B33A-B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Friedrich WY13B33A-B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Friedrich WY13B33A-B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Friedrich WY13B33A-B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Friedrich WY13B33A-B.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Friedrich WY13B33A-B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Friedrich WY13B33A-B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Friedrich WY13B33A-B.

Le manuel d’utilisation complet Friedrich, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Friedrich WY13B33A-B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Friedrich WY13B33A-B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFriedrich WY13B33A-B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Friedrich WY13B33A-B - qui devraient nous aider dans les premières étapes lors de l'utilisation Friedrich WY13B33A-B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Friedrich WY13B33A-B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Friedrich WY13B33A-B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Friedrich WY13B33A-B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Friedrich WY13B33A-B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Friedrich WY13B33A-B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)