Manuel d’utilisation AcuRite 00638A2

16 pages Non applicable
Télécharger

Aller à la page of 16

Summary
  • AcuRite 00638A2 - page 1

    SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration ............... 2 FCC Infor mation .................... 2 Features & Benets: 3-in-1 ....... 3 Features ...

  • AcuRite 00638A2 - page 2

    2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product. Locate the t ab and peel of f to remov e. Pac kage C ...

  • AcuRite 00638A2 - page 3

    3 Features & Benets 3-in-1 SENSOR 1 . T emperature & Humidity Sensors (internal) 2. Release Lev er for Batter y Access 3. Mounting Point 4. Wind Speed Anemometer 5. Mounting Hardware Includes anchors and screws. 6. Mounting Brac ket 7 . A-B-C Switc h (not shown) ID code that must matc h display’s A -B-C switc h to ensure units synchron ...

  • AcuRite 00638A2 - page 4

    4 Features & Benets Display Unit 6 1 31 30 2 3 4 5 18 17 19 20 21 8 7 9 10 11 12 13 15 14 16 22 23 26 25 24 29 28 27 32 33 34 ...

  • AcuRite 00638A2 - page 5

    5 DISPL AY UNIT 1 . Date 2. Low Battery Indicat or 3. Atomic Cloc k Maintains time with split-second accuracy and automatically updates for daylight saving time. 4. Atomic Cloc k Signal Strengt h 5. Selected Time Zone 6. Barometric Pressure Arrow icon indicates the direction the pressure is trending. 7 . Histor y Chart Icon Indicates data is curren ...

  • AcuRite 00638A2 - page 6

    6 SETUP Set the A-B-C Switc h The A -B-C switc h is located inside the batt er y compar tment. It can be set to A , B or C. How ev er , you must select the same letter c hoices for bot h the sensor and the displa y unit in order for the units to sync hronize. Install or Replace Batteries AcuRite recommends high quality alkaline or lithium batter ie ...

  • AcuRite 00638A2 - page 7

    7 PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENT ALL Y SAFE WAY AND IN ACCORDANCE WITH Y OUR LOCAL LAWS AND REGUL ATIONS. BA TTERY SAFETY : Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity ...

  • AcuRite 00638A2 - page 8

    8 Atomic Cloc k AcuRite atomic cloc ks use a radio-controlled signal to synchronize to t he correct time broadcast by the National Institute of S tandards and T echnology (NIST) Radio Station WWVB, locat ed near For t Collins, Colorado. WWVB broadcasts the current time and dat e with split-second accuracy . The atomic cloc k and calendar will maint ...

  • AcuRite 00638A2 - page 9

    9 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding envir onmental conditions. Proper placement of bot h the display unit and t he sensor are critical t o the accuracy and per for mance of this product. Display Unit Placement Place the displa y unit in a dr y area free of dir t and dust. T o ensure accurate temperature mea ...

  • AcuRite 00638A2 - page 10

    10 3-in-1 Sensor Installation Guidelines INSTALLATION HEIGHT Mount t he sensor at least 5 fee t (1 .5 met ers) of f the ground (higher is better for wind measurement) in an open area. Secure to fence post, 4”x4” wood, 3/4” pole, etc. (not included) LEVEL INSTALLATION Use a bubble level (not included) to ensure le vel installation for accurate ...

  • AcuRite 00638A2 - page 11

    11 Using The Weat her Center Learning Mode Self-Calibrating Forecasting use a unique algorithm t o analyze c hanges in pressure o v er a time period (called Lear ning Mode) to deter mine your altitude. Af ter 1 4 days, t he Learning Mode icon disappears from the displa y screen. At this point, t he self-calibrated pressure is tuned in to your locat ...

  • AcuRite 00638A2 - page 12

    12 High & Low Records The “MIN/MAX” button displays minimum and maximum recordings for outdoor and indoor temperature and humidity . T o view the MINIMUM temperature and humidity readings, press and release the “MIN/MAX” button until the “MIN” icon appears on t he display next to t he low r ecords. T o view the MAXIMUM t emperature ...

  • AcuRite 00638A2 - page 13

    13 Problem Possible Solution Outdoor temperature is ashing or showing dashes Flashing of the outdoor t emperature may be an indication of wireless inter ference. • Make sure the A -B-C switc h in the batt er y compar tments of bot h the displa y unit and sensor are switched t o the same lett er . Y ou may choose A , B or C; but both units must ...

  • AcuRite 00638A2 - page 14

    14 Care & Maintenance Display Unit Car e Clean with a sof t, dam p cloth. Do no t use caustic cleaners or abrasiv es. K eep away from dust, dirt and moisture. Clean ventilation por ts regularly wit h a gentle puf f of air . 3-in-1 Sensor Care Clean the Sensor Clean with a sof t, dam p cloth. Do no t use caustic cleaners or abrasiv es. Insect Pr ...

  • AcuRite 00638A2 - page 15

    15 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. W e recommend t hat you visit us at www .AcuRite.com for ...

  • AcuRite 00638A2 - page 16

    ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology . Visit www .AcuRite.com/patents for details. Printed in China 00632 INST 0827 1 3 It’ s more than acc ...

Fabricant AcuRite Catégorie Weather station

Les documents que nous recevons du fabricant de l'appareilAcuRite 00638A2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques AcuRite
- manuels d’utilisations 00638A2
- fiches produit AcuRite
- dépliants
- ou étiquettes-énergie AcuRite 00638A2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation AcuRite 00638A2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation AcuRite 00638A2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur AcuRite 00638A2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit AcuRite 00638A2.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil AcuRite 00638A2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser AcuRite 00638A2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs AcuRite 00638A2.

Le manuel d’utilisation complet AcuRite, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel AcuRite 00638A2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières AcuRite 00638A2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAcuRite 00638A2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil AcuRite 00638A2 - qui devraient nous aider dans les premières étapes lors de l'utilisation AcuRite 00638A2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de AcuRite 00638A2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service AcuRite 00638A2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de AcuRite 00638A2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec AcuRite 00638A2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec AcuRite 00638A2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)