    TECHNICAL GUIDE AFFINITY SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R-410A MODELS: CZB018 THRU 060 (1.5 THRU 5 NOMINAL TONS ) Due to continuous pr od uct improvement, sp eci fications are subject to change without n otice. Visit us on the web at www .yor k.com Additional rating informa tion can be foun d at www .ari.or g/aridirector y LISTED ISO 90 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 2

    246723-YTG-J-1006 2 Unitary Products Group All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. PHYSICAL AND ELECTRICAL DA T A MODEL CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Supply V oltage 208-230V , 1 φ, 60Hz Normal V oltage Range 1 187 to ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 3

    246723-YTG-J-1006 Unitary Products Group 3 Additional R-410A Charge / TXV Size f or V arious Matche d Sy stems Out door Unit CZB0181 1 CZB0241 1 C ZB0301 1 CZB0361 1 C ZB0421 1 CZB0481 1 CZB0601 1 Unit Orifice (s) 1 TVM901 1 TVM903 1 T VM903 1 TVM903 1 TVM904 1T V M 4 C 1 1 TVM905 1 TVM905 Factory R-410A Charge, lbs- oz 5-13 6-4 7-4 6-4 8-13 8-12 1 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 4

    246723-YTG-J-1006 4 Unitary Products Group PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrig erant for the condenser, the smallest evaporator and 15 feet of intercon- necting line tubing. 2. V erify the TXV and additional char ge required for specific evaporator coil in th e system using the above table. 3. Additional ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 5

    246723-YTG-J-1006 Unitary Products Group 5 COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL ELECTRIC HEA T KW 2 W RA TED CFM NET MBH SEER EER TOT AL SENS. 1 PH 13 SEER AC WITH MA CZB0181 1 MA08B 2,5,8,10 17 FC/MC18B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5,8,10 17 FC/MC24B 600 18.0 12.1 13.00 1 1.00 MA08B 2,5 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 6

    246723-YTG-J-1006 6 Unitary Products Group 1 PH 13 SEER AC WITH AHP/ SHP / F*FP CZB0181 1 AHP18 2,5,8 17 – 600 18.0 12.1 13.00 1 1.00 AHP24 2,5,8,10 17 – 600 18.0 12.3 13.00 1 1.00 F*FP024 5,8,1 0 17 – 600 18.0 12.1 13.00 1 1.00 CZB0241 1 AHP24 2,5,8,10 17 – 800 23.0 16.9 13.00 1 1.00 F*FP030 5,8,10,15 17 – 800 23.0 16.7 13.00 1 1.00 CZB0 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 7

    246723-YTG-J-1006 Unitary Products Group 7 COOLING CAP ACITY - Up flow , Downflow & Horizont al Furnaces and Coils UNIT MODEL FURNACE COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RA TED CFM NET MBH SEER 1,2 EER TOT AL SENS. CZB0181 1 450 750 14,17 FC/MC/PC/UC18 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/PC/UC24 600 18.0 12.1 13.00 1 1.00 14,17 FC/MC/ ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 8

    246723-YTG-J-1006 8 Unitary Products Group COOLING CAP ACITY - With V ariable Spe ed Furnaces UNIT MODEL V ARIABLE SPEED FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM NET MBH SEER EER T OTAL SENS. 1 PH 13 SEER AC WITH V ARIABLE SPEED FURNACES 2 CZB0181 1 PV8*A12 FC/MC/PC24A 14 600 18.0 12.2 14.00 1 1.50 PV9*A12 FC/MC/PC24A 14 600 18.0 12.2 14.0 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 9

    246723-YTG-J-1006 Unitary Products Group 9 CZB0421 1 PV8*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C16 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*C20 FC/MC/PC48C 21 1400 41 .0 30.2 13 .50 1 1.00 PV9*D20 FC/MC/PC48D 24 1400 41 .0 30.2 13 .50 1 1.00 PV8*C20 HC60 21 1400 40.5 29.8 1 ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 10

    246723-YTG-J-1006 10 Unitary Products Group ACCESSORIES* Hard St art Kit (024-31994-000, 024-319 95-000) - Provides increased starting torque for areas w ith low voltage. TXV Kits - 1 TV09 series thermal exp ans ion valves precisely meter refrigerant for optimum performance Low Ambient Pressure Switch Kit (2LA 06700424) - Allows use of air conditio ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 11

    246723-YTG-J-1006 Unitary Products Group 11 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 12

    246723-YTG-J-1006 12 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 13

    246723-YTG-J-1006 Unitary Products Group 13 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 14

    246723-YTG-J-1006 14 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 15

    246723-YTG-J-1006 Unitary Products Group 15 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 16

    246723-YTG-J-1006 16 Unitary Products Group Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible capacity increa ses by 1060 BTUH per 100 0 CFM per degree above the listed temperatur e and decre ases by 1060 BTUH per 1000 CFM per degree be ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 17

    246723-YTG-J-1006 Unitary Products Group 17 Multipliers for determining th e performance with other indoor sec tions. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween 73-87 F), sensible cap acity increases by 1060 BTUH per 100 0 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1 000 CFM per degree bel ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 18

    246723-YTG-J-1006 18 Unitary Products Group NOTES ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 19

    246723-YTG-J-1006 Unitary Products Group 19 NOTES ...

  • York 13 SEER - R410A CZB018 THRU 060 - page 20

    Subject to change without notice. Printe d in U.S.A. 246723-YTG-J-1006 Copyright © by York International/JCI 2006. All righ ts reserved. Supersedes: 246723-YTG-H-0906 Unitary 5005 Norman Product s Y ork OK Group Drive 73069 NOTES ...

Fabricant York Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilYork 13 SEER - R410A CZB018 THRU 060 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations 13 SEER - R410A CZB018 THRU 060
- fiches produit York
- dépliants
- ou étiquettes-énergie York 13 SEER - R410A CZB018 THRU 060
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York 13 SEER - R410A CZB018 THRU 060.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York 13 SEER - R410A CZB018 THRU 060, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York 13 SEER - R410A CZB018 THRU 060. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York 13 SEER - R410A CZB018 THRU 060.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York 13 SEER - R410A CZB018 THRU 060, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York 13 SEER - R410A CZB018 THRU 060 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York 13 SEER - R410A CZB018 THRU 060.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York 13 SEER - R410A CZB018 THRU 060 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York 13 SEER - R410A CZB018 THRU 060, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork 13 SEER - R410A CZB018 THRU 060 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York 13 SEER - R410A CZB018 THRU 060 - qui devraient nous aider dans les premières étapes lors de l'utilisation York 13 SEER - R410A CZB018 THRU 060
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York 13 SEER - R410A CZB018 THRU 060
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York 13 SEER - R410A CZB018 THRU 060 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York 13 SEER - R410A CZB018 THRU 060?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York 13 SEER - R410A CZB018 THRU 060, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York 13 SEER - R410A CZB018 THRU 060 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)