Manuel d’utilisation Emerson CF4600GLZ00

20 pages 0.32 mb
Télécharger

Aller à la page of 20

Summary
  • Emerson CF4600GLZ00 - page 1

    LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor , this warranty will la ...

  • Emerson CF4600GLZ00 - page 2

    2 W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accident ...

  • Emerson CF4600GLZ00 - page 3

    3 This Manual is Designed to Make it as Easy as Possible for Y ou to Assemble, Install, Operate and Maintain Y our Ceiling Fan Do not install or use fan if any part is damaged or missing. Call T oll-Free: 1-800-654-3545 ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifica ...

  • Emerson CF4600GLZ00 - page 4

    4 m. One loose parts bag containing: 1. T wo 8-32 x 1-1/4” threaded studs 2. T wo 8-32 x 1” threaded studs 3. Four knurled knobs 4. Four lockwashers 5. Five wire connectors 6. One clevis pin/hairpin clip assembly 7. Eleven 5-32 x 9/16” pan head screws 8. Sixteen 10-32 x 1/2” pan head screws 9. Sixteen #10 flat washers 10. One 5/16-18 x 1/4? ...

  • Emerson CF4600GLZ00 - page 5

    5 1. Mount the fan blades to the blade flanges using three 10-32 x 1/2” pan head screws and three #10 flat washers (screws and washers supplied) (Figure 1). How to Assemble Y our Ceiling Fan T o reduce the risk of personal injury , do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not ins ...

  • Emerson CF4600GLZ00 - page 6

    3. Carefully rest the switch cup assembly on the fan blades, then engage the connector of the switch cup assembly with the motor connector (Figure 3). The two connectors are keyed and must be mated correctly before they can be engaged. Make sure the connectors are engaged properly . 4. Remove and retain four pan head screws from the rim of the swit ...

  • Emerson CF4600GLZ00 - page 7

    7 HAIRPIN CLIP CLEVIS PIN DOWNROD MOTOR COUPLING 5/16-18 x 1/4" SETSCREW Figure 6 PIN HANGER BALL SETSCREW DOWNROD Figure 5 8. Separate, untwist and unkink the three motor leads. Route the motor lead wires through the downrod and seat the downrod in the motor coupling (Figure 6). 9. Align the clevis pin holes in the downrod with the holes in t ...

  • Emerson CF4600GLZ00 - page 8

    14. Carefully place the upper housing over the upper glass, making certain that the upper glass seats firmly in the upper housing flange. 15. Align the two holes in the housing trim with two threaded holes in the upper housing (Figure 8). Loosely install two 8-32 x 1/2” pan head screws (supplied) to secure the trim. Repeat this procedure for the ...

  • Emerson CF4600GLZ00 - page 9

    9 18. Position the ceiling cover over the downrod and rest it on the upper housing (Figure 10). NOTE: Be careful not to scratch the finish on the upper housing. PIN HANGER BALL DOWNROD SETSCREW CEILING COVER ! W ARNING It is critical that the pin in the hanger ball is properly installed and the setscrew securely tightened. Failure to verify that th ...

  • Emerson CF4600GLZ00 - page 10

    10 Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard. ! W ARNING T o avoid possible fire or shock, do not pinch wires between the hanger ball/downrod assembly and hanger bracket. ! W ARNING NOTE: CEILING COVER, SUPPL Y WIRES AND F AN WIRES OMITTED FOR CLARITY . OUTLET BOX HANGER BRACKET HANGER BA ...

  • Emerson CF4600GLZ00 - page 11

    11 1. Position the supply wires to the left side of the outlet box (Figure 14); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 14. NOTE: Make all wiring connections using wire connectors (supplied). Make sure that all connections are tig ...

  • Emerson CF4600GLZ00 - page 12

    3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver . 4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14). 5. Lift the ceiling cover up to the threaded studs and turn until the stud ...

  • Emerson CF4600GLZ00 - page 13

    13 Setting Operating Frequency of W all Control and Receiver (Figure 17) Y our wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows: 1. Slide the four switch leve ...

  • Emerson CF4600GLZ00 - page 14

    14 6. Screw wall control into wall box and install decorator style faceplate (included). Leave wall control in “OFF” mode until fan installation is completed. 7. Refer to page 5 and complete the ceiling fan installation. EMERSON ® HI MED LOW FAN OFF LIGHT ON OFF BLACK BLK HOT F AN/LIGHT WALL CONTROL WALL BOX T O L O A D T O 1 2 0 V A C S O U R ...

  • Emerson CF4600GLZ00 - page 15

    15 ST ANDARD WIRING FOR EXISTING 3-WA Y CONTROL HOT BLK F AN/LIGHT WALL CONTROL BLK TRA VELER WIRES BLK BLK BLACK LOAD BLACK LOAD TRA VELER WIRES HOT BLK EXISTING WALL CONTROL EMERSON ® EMERSON ® HI MED LOW FAN OFF LIGHT ON OFF HI MED LOW FAN OFF LIGHT ON OFF Figure 21 Operating Y our Ceiling Fan IMPORT ANT Fan installation must be completed, inc ...

  • Emerson CF4600GLZ00 - page 16

    Replacing Light Bulbs SETSCREW UPPER HOUSING/GLASS HOUSING TRIM 7-WA TT (MAXIMUM) CANDELABRA BULB (6) LOWER HOUSING FLANGE Figure 24 T o replace a burned out light bulb, loosen the setscrew in the upper housing and raise the upper housing/glass enough to access the defective bulb, then tighten the setscrew (Figure 24). Unscrew the defective bulb an ...

  • Emerson CF4600GLZ00 - page 17

    The use of any other control not specifically approved for this fan could result in fire, shock and personal injury . ! W ARNING This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designa ...

  • Emerson CF4600GLZ00 - page 18

    Repair Parts 1 17 2 3 18 20 6 7 10 11 12 21 22 25 13 15 24 23 16 19 26 14 30 29 6 7 5 4 28 27 HI MED LOW FAN OFF LIGHT ON OFF EMERSON 1 2 3 4 ON 8 9 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REP AIR P ARTS WHEN ORDERING REP AIR P ARTS, AL W A YS GIVE THE FOLLOWING INFORMA TION: • P ART NUMBER • N ...

  • Emerson CF4600GLZ00 - page 19

    19 Part Numbers Key Model No. Model No. N o . Description CF4600GLZ00 CF4600WB00 * Hanger Pack, Consisting of: 761655-51 761655-52 1 Hanger Bracket — — 2 Hanger Ball — — 3 Downrod — — * Parts Bag, Containing: 762990 762990 4 Wire Connector (5) — — 5 Threaded Stud, 8-32 x 1-1/4” (2) — — 6 Knurled Knob (4) — — 7 Lockwasher ( ...

  • Emerson CF4600GLZ00 - page 20

    T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch circuit fuses start. blown. or circuit breakers. W ARNING: Make sure main power is turned off. 2. Loose power line 2. Check line power connections to fan. connections to the fan, or 3. Fan/Light W all Control is OFF . 3. T u ...

Fabricant Emerson Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilEmerson CF4600GLZ00 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Emerson
- manuels d’utilisations CF4600GLZ00
- fiches produit Emerson
- dépliants
- ou étiquettes-énergie Emerson CF4600GLZ00
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Emerson CF4600GLZ00.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Emerson CF4600GLZ00, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Emerson CF4600GLZ00. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Emerson CF4600GLZ00.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Emerson CF4600GLZ00, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Emerson CF4600GLZ00 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Emerson CF4600GLZ00.

Le manuel d’utilisation complet Emerson, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Emerson CF4600GLZ00 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Emerson CF4600GLZ00, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmerson CF4600GLZ00 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Emerson CF4600GLZ00 - qui devraient nous aider dans les premières étapes lors de l'utilisation Emerson CF4600GLZ00
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Emerson CF4600GLZ00
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Emerson CF4600GLZ00 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Emerson CF4600GLZ00?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Emerson CF4600GLZ00, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Emerson CF4600GLZ00 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image