Manuel d’utilisation Heatiator CD4236ILR-C

73 pages 4.45 mb
Télécharger

Aller à la page of 73

Summary
  • Heatiator CD4236ILR-C - page 1

    1 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - DO NOT try to light any appliance. - DO NOT touch any electrical switch. DO NOT use any phone in your building. - Immedi ...

  • Heatiator CD4236ILR-C - page 2

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on fi replace: _____________________ Dealership purchased from: _________ ...

  • Heatiator CD4236ILR-C - page 3

    3 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury . • CAUTION! Indicates a hazardous situati ...

  • Heatiator CD4236ILR-C - page 4

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 4  = Contains updated information. 13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 53 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 14 Appliance Setup A. Remove Fixed Glass Assembly . . . . . ...

  • Heatiator CD4236ILR-C - page 5

    5 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and ele ...

  • Heatiator CD4236ILR-C - page 6

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 6 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS:  7KLVZDUUDQWRQOFRYHUV++7DSSOLDQFHVWKDWDUHSXUFKDVHGW KURXJKDQ++7 DXWKRUL]HGGHDOHURUGLVWULEXWRU  $ OLVWRI ++7DXWKRUL]HGGHDOHUVLVDYDLODEOHRQW ...

  • Heatiator CD4236ILR-C - page 7

    7 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 C. BTU Speci fi cations MODELS: CD4236IR-C, CD4236ILR-C, CD4842IR-C, CD4842ILR-C LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Direct Vent Gas Appliance Heater STANDARD: ANSI Z21.88-2009 • CSA 2.33-2009 This product is listed to ANSI standards for “V ented Gas Ap ...

  • Heatiator CD4236ILR-C - page 8

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and wher ...

  • Heatiator CD4236ILR-C - page 9

    9 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions. Failure to operate fi replace according to operating instructions could cause fi re or injury . DECORA TIVE DOORS (NOT SHOWN) ...

  • Heatiator CD4236ILR-C - page 10

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.2. Avoid placing candles and other heat-sensitive objects on mantel or hearth. Heat may damage these objects. Figure 2.2 ...

  • Heatiator CD4236ILR-C - page 11

    11 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 I. Control Module Operation 1. The control module has an ON/OFF/REMOTE selector switch that must be set. See Figure 2.3. OFF Position: Appliance will ignore all power inputs and will not respond to any commands from a wall switch or remote. The unit should be in the OFF posit ...

  • Heatiator CD4236ILR-C - page 12

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 12 K. Lighting Instructions (IPI) 1. This appliance is equipped with an ignition device which automatically lights the burner. DO NOT try to light the burner by hand. 2. Wait fi ve (5) minutes to clear out any gas. Then smell for gas, including near the fl oor. If you smell ga ...

  • Heatiator CD4236ILR-C - page 13

    13 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly . See Section 14.H. • Clean fi xed glass assembly . See Section 3. • Repl ...

  • Heatiator CD4236ILR-C - page 14

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 14 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care. Glass is breakable. • Avoid striking, scratching or slamming glass • Avoid abrasiv ...

  • Heatiator CD4236ILR-C - page 15

    15 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. Maintenance T asks-Quali fi ed Service T echnician The following tasks must be performed by a quali fi ed ser- vice technician. Gasket Seal and Glass Assembly Inspection Frequency: Annually By: Quali fi ed Service T echnician T ools needed: Protective gloves, drop cloth ...

  • Heatiator CD4236ILR-C - page 16

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 16 C. Logs/Grate and V alve Assembly Removal It may become necessary to remove the logs/grate and valve assembly . This task should be performed by a quali- fi ed service technician. The base pan does not need to be removed to service the burner assembly . 1. Remove the two top ...

  • Heatiator CD4236ILR-C - page 17

    17 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Figure 3.1 1 V alve Assembly Removal 5. Remove the two screws from the back corners of the burner assembly . See Figure 3.8. Figure 3.8 Remove Screws from Burner Assembly Rear Corners Figure 3.9 Remove Burner Skirt 6. Remove burner skirt by removing 4 screws. See Figure 3.9. ...

  • Heatiator CD4236ILR-C - page 18

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 18 D. Burner Identi fi cation/V eri fi cation The burner may be accessed for identi fi cation and veri- fi cation purposes. This task should be performed by a quali fi ed service technician. Only the log/grate assembly and burner skirt need to be removed in order to identif ...

  • Heatiator CD4236ILR-C - page 19

    19 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual Figure 4.1 T ypical System CEILING FIRESTOP ON FLOO ...

  • Heatiator CD4236ILR-C - page 20

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 20 B. Design and Installation Considerations Heatilator direct vent gas appliances are designed to op- erate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside. No additional outside air source is required. Installation MU ...

  • Heatiator CD4236ILR-C - page 21

    21 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.1). W ARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for servi ...

  • Heatiator CD4236ILR-C - page 22

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 22 B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase. NOTICE: T reatment of ceiling fi restops and wall shield fi restops and c ...

  • Heatiator CD4236ILR-C - page 23

    23 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 D. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc). M ...

  • Heatiator CD4236ILR-C - page 24

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 24 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 .................................................1.25* Over 7/12 to 8/12 ............................................ ...

  • Heatiator CD4236ILR-C - page 25

    25 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches................. clearance to window or door that may be opened, or to permanently closed window ...

  • Heatiator CD4236ILR-C - page 26

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 26 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies DVP or SLP venting systems. Refer to Sec- tion 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers. The pipe is tested to be ...

  • Heatiator CD4236ILR-C - page 27

    27 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 E. V ent Diagrams T op V ent—Horizontal T ermination—T wo 45º Elbows Installation requirements to replace the fi rst 90º elbow with two 45º elbows: 4 ft min. (1.22 m) 20 ft max. (6.10 m) Figure 7.3 T op V ent - Horizontal T ermination Fire Risk. Explosion Risk. Do NOT ...

  • Heatiator CD4236ILR-C - page 28

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 28 INST ALLED HORIZONT ALL Y H 1 H 2 V 1 H 1 V 1 Figure 7.4 Figure 7.5 T op V ent - Horizontal T ermination One Elbow T wo Elbows Note: For corner installations: A 6 inch (152 mm) section of straight pipe may need to be attached to the appliance before a 90º elbow , to allow th ...

  • Heatiator CD4236ILR-C - page 29

    29 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Figure 7.6 T op V ent - Horizontal T ermination - (continued) Three Elbows H 2 H 1 V 2 V 1 V 1 Min. H 1 Max. V 2 Min. H 2 Max. Elbow only 2 ft. 610 mm 0 in. 0 mm 1 ft. 305 mm 6 in. 152 mm 3 ft 914 mm 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 6 ft. 1.8 m 1 ft. 305 mm 6 ft. 1.8 m ...

  • Heatiator CD4236ILR-C - page 30

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 30 EXHAUST SHIELD FLUE RESTRICTOR T op V ent - V ertical T ermination No Elbow Figure 7.7 Note: If installing a vertical vent/ termination off the top of the ap- pliance, the fl ue restrictor should be used. V 1 V 1 = 60 ft. Max. (18.3 m) V 1 = 3 ft. Min. (914 mm) Flue Restrict ...

  • Heatiator CD4236ILR-C - page 31

    31 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 H 1 V 1 V 2 T op V ent - V ertical T ermination (continued) Figure 7.12 T wo Elbows Figure 7.1 1 4. Center the Flue Restrictor on vent and secure in place by using two self-tapping screws (see Figure 7.8 and Figure 7.1 1). 5. Reinstall the Exhaust Shield. 3. Match the amount ...

  • Heatiator CD4236ILR-C - page 32

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 32 Figure 7.13 T op V ent - V ertical T ermination - (continued) Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 V 2 V 1 H 1 + H 2 V 2 V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft. 305 mm * * * 1 ft. 305 mm 6 in. 152 mm 2 ft. 610 mm * * * 2 ft. 610 mm 1 ft. 305 mm 2 ft ...

  • Heatiator CD4236ILR-C - page 33

    33 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Rear V ent - Horizontal T ermination Figure 7.15 No Elbow One 45º Elbow H 1 H 1 H 1 = 18 in. (457 mm) Maximum Figure 7.14 H 1 = 12 in. (305 mm) Maximum CD4236IR H 1 = 15 in. (381 mm) Maximum CD4842IR ...

  • Heatiator CD4236ILR-C - page 34

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 34 INSTALLED HORIZONTALLY H 3 H 1 H 2 V 1 Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.16 Figure 7.17 Three Elbows H 1 H 2 V 1 H 1 Maximum V 1 Minimum H 2 H 1 + H 2 Maximum 1 ft. 305 mm Back to Back 90º Elbows 1 ft. 305 mm 2 ft. 610 mm 2 ft. 610 mm 6 ...

  • Heatiator CD4236ILR-C - page 35

    35 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Rear V ent - V ertical T ermination One Elbow Figure 7.18 T wo Elbows Figure 7.19 H 1 V 1 INST ALL ED HORIZONT ALL Y H 1 H 2 V 1 V 1 Minimum H 1 Maximum 6 in. 152 mm 2 ft. 610 mm 1 ft. 305 mm 3 ft. 914 mm 2 ft. 610 mm 5 ft. 1.5 m 3 ft. 914 mm 7 ft. 2.1 m 4 ft. 1.2 m 8 ft. 2.4 ...

  • Heatiator CD4236ILR-C - page 36

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 36 Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.20 Three Elbows Figure 7.21 INST ALLED HORIZONT ALL Y H 3 H 1 H 2 V 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft. 2.4 m 6 ft. 1.8 m *** 9 ft. 2.7 m 7 ft. 2.1 m *** 10 ft. 3.1 ...

  • Heatiator CD4236ILR-C - page 37

    37 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 A* B* 10 in. 12 in. C D 10 in. 12 in. A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent. DO NOT pack insulation or other combustibles: • Between ceiling fi restops • Between wall shield fi restops • Around vent system Fail ...

  • Heatiator CD4236ILR-C - page 38

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 38 C. Install the Ceiling Firestop A ceiling fi restop MUST be used between fl oors and attics. • DVP pipe only - Frame an opening 10 in. by 10 in. (254 mm by 254 mm) whenever the vent penetrates a ceiling/ fl oor (see Figure 8.3). • SLP pipe only - Frame opening 9 in. x ...

  • Heatiator CD4236ILR-C - page 39

    39 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield. The National Fuel Gas Code ANSI Z223.1 and NFPA 54 requires an attic shield constructed ...

  • Heatiator CD4236ILR-C - page 40

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 40 9 9 Appliance Preparation CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. A. T op V ...

  • Heatiator CD4236ILR-C - page 41

    41 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. Rear V ent CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. Figure 9.7 Fold the t ...

  • Heatiator CD4236ILR-C - page 42

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 42 Figure 9.14 Proper Positioning and Securing of an Appliance NAILING TABS (BOTH SIDES) PILOT HOLES Figure 9.12 Non-combustible Board C. Installing the Non-combustible Board The factory supplied non-combustible board spans the dis- tance from the top of the fi replace to the c ...

  • Heatiator CD4236ILR-C - page 43

    43 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 1 0 10 Inst alling V ent Pipe (D VP and SLP P ip e ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of the pipe sec tions wi th the lanced ta bs will face toward the appliance. Attach the fi rst pipe section to the starting coll ...

  • Heatiator CD4236ILR-C - page 44

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 44 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL or DVP-SLP24 adapter to the starting collar of the appliance. • Lock the vent components into place by sliding the pipe section on ...

  • Heatiator CD4236ILR-C - page 45

    45 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.10) so the seams on both pipe sections are aligned as shown in Figure 10.1 1. • Pull carefully to se ...

  • Heatiator CD4236ILR-C - page 46

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 46 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop. • Seal the gap between the vent pipe and fi restop using ...

  • Heatiator CD4236ILR-C - page 47

    47 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.15. Roof Pitc ...

  • Heatiator CD4236ILR-C - page 48

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I. Install V ertical T ermination Cap • Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the c ...

  • Heatiator CD4236ILR-C - page 49

    49 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 Figure 10.20 V enting through the wall INTERIOR HEA T SHIELD OR EXTENDED HEA T SHIELD W ALL SHIELD FIRESTOP HEA T SHIELD 1-1/2 IN. (38 MM) MIN. OVERLAP SHEA THING VENT DEPTH FROM BACK OF APPLIANCE T O OUTSIDE SURF ACE OF EXTERIOR WA LL (SEE CHART BELOW) SLIP SECTION CAN BE EX ...

  • Heatiator CD4236ILR-C - page 50

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts. B. Gas Pressure • Optimum appliance performance requi ...

  • Heatiator CD4236ILR-C - page 51

    51 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.1. • Wire the appliance ju ...

  • Heatiator CD4236ILR-C - page 52

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 52 F . W all Switch Installation for Fan (Optional) If the box is being wired to a wall mounted switch for use with a fan (See Figure 12.3): • The power supply for the appliance must be brought into a switch box. • The power can then be supplied from the switch box to the ap ...

  • Heatiator CD4236ILR-C - page 53

    53 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 1 3 13 Fi nishing A. Mantel and W all Projections W ARNING! Risk of Fire! Comply with all minimum clear- ances as speci fi ed. Framing closer than the minimums listed must be constructed entirely of noncombustible materials (i.e., steel studs, concrete board, etc.) Combustib ...

  • Heatiator CD4236ILR-C - page 54

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 54 A. Remove Fixed Glass Assembly See Section 14.H. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox. C. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cav ...

  • Heatiator CD4236ILR-C - page 55

    55 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 G. Install the Log Assembly LOG PLACEMENT INSTRUCTIONS Log Set Assembly: LOGS-4236, LOGS-4842 Models: CNXT4236IT -C, CNXT4842IT -C, CNXT4236IH-C, CNXT4842IH-C CD4236IR-C, CD4842IR-C 1. Base logs have been permanently mounted on the grate assembly . Do not attempt to remove or ...

  • Heatiator CD4236ILR-C - page 56

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 56 Figure 14.6 Air Shutter Figure 14.5 Fixed Glass Assembly H. Fixed Glass Assembly W ARNING! Risk of Asphyxiation! Handle fi xed glass assembly with care. Inspect the gasket to ensure it is undamaged and inspect the glass for cracks, chips or scratches. • DO NOT strike, slam ...

  • Heatiator CD4236ILR-C - page 57

    57 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service technician in the diagnosis of a problem a ...

  • Heatiator CD4236ILR-C - page 58

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 58 T roubleshooting (continued) Symptom Possible Cause Corrective Action 4. Pilot lights but contin- ues to spark, and main burner will not ignite. (If the pilot continues to spark after the pilot fl ame has been lit, fl ame recti fi cation has not occurred.) A. A shorted or ...

  • Heatiator CD4236ILR-C - page 59

    59 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only . For framing dimensions and clearances refer to Section 5. Figure 16.1 Appliance Dimensions CD4236IR-C Models A B C D E FRONT VIEW TOP VIEW LEFT SIDE ...

  • Heatiator CD4236ILR-C - page 60

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 60 Figure 16.1 Appliance Dimensions CD4842IR-C Models Location Inches Millimeters J 21 533 K 1 1-1 1/16 297 L 35-1/2 901 M 17-3/4 451 N 8-1/2 216 O 2-7/8 73 P 8-1/2 216 Q1 2 5 R 42-7/8 1089 Location Inches Millimeters A 48 1219 B 43-1/8 1096 C 34-3/8 873 D 36-5/8 930 E 2-3/8 60 ...

  • Heatiator CD4236ILR-C - page 61

    61 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. V ent Components Diagrams Figure 16.2 DVP vent components Pipe Effective Length Inches Millimeters DVP4 4 102 DVP6 6 152 DVP12 12 305 DVP24 24 610 DVP36 36 914 DVP48 48 1219 DVP6A 3 to 6 76 to 152 DVP12A 3 to 12 76 to 305 DVP12MI 3 to 12 76 to 305 DVP24MI 3 to 24 76 to 610 ...

  • Heatiator CD4236ILR-C - page 62

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 62 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be used o ...

  • Heatiator CD4236ILR-C - page 63

    63 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in. (349 mm) 5 in. (127 mm) 13-3/4 in. (349 mm) Cap Shield DRC-R ...

  • Heatiator CD4236ILR-C - page 64

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 64 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 7-1/4 in. 12 in. 305 mm (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (Not compatible with Intellifire Plus? ...

  • Heatiator CD4236ILR-C - page 65

    65 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. V ent Components Diagrams (continued) DVP-HRC-SS DVP-HRC-ZC-SS HORIZONT AL TERMINA TION CAP 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3° 87° Effective Length 5-3/4 to 8-3/8 in. 146 to 213 mm 5-1/2 in. 140 mm 8-3/8 in. 213 mm F ...

  • Heatiator CD4236ILR-C - page 66

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 66 B. V ent Components Diagrams (continued) Figure 16.7 SLP Series V ent Components 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 9-7/8 in. 251 mm 6-1/2 in. 165 mm 9-1/4 in. 235 mm SLP45 45° Elbow SLP90 90° Elbow Effective He ...

  • Heatiator CD4236ILR-C - page 67

    67 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components SLP-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black DVP-2SL Adapt ...

  • Heatiator CD4236ILR-C - page 68

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 68 Fire Risk. • When using SLP-HRC-SS and SLP-HRC-ZC- SS termination caps on top vented fi replaces, a one foot minimum vertical vent section is required before installing fi rst elbow . 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) 10-7/8 in. 276 mm 10-1/2 in. 267 mm 3 ...

  • Heatiator CD4236ILR-C - page 69

    69 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 C. Service Parts Beginning Manufacturing Date: Dec 2009 Ending Manufacturing Date: ______ CD4236IR-C, CD4236ILR-C 36 in. Caliber - DV IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and seri ...

  • Heatiator CD4236ILR-C - page 70

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 70 Service Parts Beginning Manufacturing Date: Dec 2009 Ending Manufacturing Date: ______ CD4842IR-C, CD4842ILR-C 42 in. Caliber - DV IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial ...

  • Heatiator CD4236ILR-C - page 71

    71 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P AR ...

  • Heatiator CD4236ILR-C - page 72

    Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 72 Service Parts CD4236IR-C, CD4236ILR-C, CD4842IR-C, CD4842ILR-C IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an auth ...

  • Heatiator CD4236ILR-C - page 73

    73 Heatilator • CD4236IR-C, CD4842IR-C • 2207-900 Rev . J • 1 1/1 1 D. Contact Information Please contact your Heatilator dealer with any questions or concerns. For the location of your nearest Heatilator dealer , please visit www .heatilator .com. - NOTES - ________________________________________________________________________________ ____ ...

Fabricant Heatiator Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilHeatiator CD4236ILR-C peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Heatiator
- manuels d’utilisations CD4236ILR-C
- fiches produit Heatiator
- dépliants
- ou étiquettes-énergie Heatiator CD4236ILR-C
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Heatiator CD4236ILR-C.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Heatiator CD4236ILR-C, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Heatiator CD4236ILR-C. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Heatiator CD4236ILR-C.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Heatiator CD4236ILR-C, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Heatiator CD4236ILR-C par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Heatiator CD4236ILR-C.

Le manuel d’utilisation complet Heatiator, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Heatiator CD4236ILR-C - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Heatiator CD4236ILR-C, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHeatiator CD4236ILR-C qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Heatiator CD4236ILR-C - qui devraient nous aider dans les premières étapes lors de l'utilisation Heatiator CD4236ILR-C
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Heatiator CD4236ILR-C
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Heatiator CD4236ILR-C dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Heatiator CD4236ILR-C?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Heatiator CD4236ILR-C, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Heatiator CD4236ILR-C il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)