  • Hill Phoenix P074749F - page 1

    P074749F Rev . 2 07/09 O WZA Installation & Operation Handbook FROZEN FOOD CASE T able of Contents Energy Data & Dimensions ........................... 2-3 General Information ......................................... 4 Installation ......................................................5-6 Refrigeration Piping .............................. ...

  • Hill Phoenix P074749F - page 2

    ii ...

  • Hill Phoenix P074749F - page 3

    Important A t Hill PHOENIX ® , the safety of our customers and employees, as well as the ongoing performance of our products, are top priorities. T o that end, we include important warning messages in all Hill PHOENIX installation and operation handbooks, ac- companied by an alert symbol paired with the word "DANGER" , "WARNING" ...

  • Hill Phoenix P074749F - page 4

    COMPONENT All measurements are taken per ARI 1200 - 2002 specifications. E NERGY D ATA OWZA Defrost Contr ols Model Defrosts Per Day Electric Defrost 6 Timed Of f Defrost 7 Hot Gas Defrost Reverse Air Defrost Fail-Safe (min) T ermination T emp (°F) Fail-Safe (min) T ermination T emp (°F) Fail-Safe (min) T ermination T emp (°F) Fail-Safe (min) T ...

  • Hill Phoenix P074749F - page 5

    C ASE D IMENSIONS MODEL OWZA CONDENSING UNIT CONDENSING UNIT DRAIN PA N JUNCTION BOX 53-1/4 in [135.3 cm] 96 in [243.8 cm] {8’ CASE} 1-1/2 in [3.8 cm] 42-5/8 in [108.2 cm] C L 43 in [109.2 cm] 13-1/8 in [33.3 cm] 8-7/8 in [22.6 cm] 33-11/16 in [85.6 cm] 7-7/8 in [20.0 cm] 29-5/8 in [75.3 cm] 43-1/4 in [109.9 cm] 42-9/16 in [108.1 cm] 51-5/16 in [ ...

  • Hill Phoenix P074749F - page 6

    CASE DESCRIPTION This manual specifically covers the OWZA frozen food mer - chandiser . STORE CONDITIONS Hill PHOENIX cases are designed to operate in an air-condi- tioned store that maintains a 75°F (24°C) store temperature and 55% (max) relative humidity (CRMA conditions). Case opera- tion will be adversely affected by exposure to excessively h ...

  • Hill Phoenix P074749F - page 7

    I NSTALLATION MOVING CASES Hill PHOENIX display cases are generally shipped to stores with casters installed on the base frame. The casters make the job of moving cases easier for everyone involved in the ship- ping and installation process, as well as reducing the chance of damage from raising and lowering cases with ”J” bars to place them on ...

  • Hill Phoenix P074749F - page 8

    R EFRIGERATION P IPING Refrigeration components for OWZA cases are easily acces- sible in the tank and beneath the case. The expansion valve and suction line 1/4” access valve are both located on the front-left side of the tank and are acces- sible without lifting the fan plenum. These components may be reached by lifting only the left-hand deck ...

  • Hill Phoenix P074749F - page 9

    MODEL OWZA (Refrigeration Piping, cont'd) T ANK AREA Split Evaporator TVX Bulb Fan Plenum 1/4" Access V alve Flow Direction Service V alve Compressor Condenser Fan Receiver Filter Drier Dual Pressur e Control Condenser TVX TVX 1/4" Access V alve Condenser Compressor Service V alve Condenser Fan Service V alve Service V alve Receiver ...

  • Hill Phoenix P074749F - page 10

    P LUMBING MODEL OWZA The “P” trap assembly – attached to the case at the factory so no assembly is required – directs the case drainage to the drain pan. The case drain is located front-and-center in the case for con- venient access – simply remove the front kick plate. Should any future maintenance issues arise, it is important to note t ...

  • Hill Phoenix P074749F - page 11

    The OWZA comes pre-wired with a NEMA L14-30P twist- lock plug (250 volt, 4-prong). For export models, a NEMA L6-30 twist-lock plug (250 volt, 3-prong) is used. Dual Dixell XR03CX digital controllers are provided for case operation and programming. The controllers are located inside the electrical junction box and are utilized according to your temp ...

  • Hill Phoenix P074749F - page 12

    JUNCTION BOX A IR F LOW , D EFR OST & T EMP C ONTR OL DEFROST & TEMPERA TURE CONTROLS OWZA cases are equipped with both Electric (low-temp) and T imed-Off (medium-temp) defrost and can be run in either low- or medium-temperature defrost modes. Switching between the two different temperature modes is easily done by using a spe- cial key swit ...

  • Hill Phoenix P074749F - page 13

    CASE CLEANING Cases are designed to facilitate cleaning. All surfaces pitch to a deep-drawn drain trough that angles toward the front-center of the case where the waste outlet is located for easy access. The coil is covered to prevent waste fluids from entering, but it is easily accessible for cleaning: simply remove the two coil-cover fasteners, t ...

  • Hill Phoenix P074749F - page 14

    1. Contact the Service Parts Department at: 1-800-283-1109 2. Pr ovide the following information about the part you ar e or dering: • Model number and serial number of the case for which the part is intended. • Length of the part (if applicable). • Color of part (if painted) or color of polymer part. • Whether part is for left- or right-han ...

  • Hill Phoenix P074749F - page 15

    A PPENDIX A: D OMESTIC W IRING D IAGRAM ...

  • Hill Phoenix P074749F - page 16

    ...

  • Hill Phoenix P074749F - page 17

    ...

  • Hill Phoenix P074749F - page 18

    ...

  • Hill Phoenix P074749F - page 19

    ...

  • Hill Phoenix P074749F - page 20

    A PPENDIX B: E XPORT W IRING D IAGRAM ...

  • Hill Phoenix P074749F - page 21

    ...

  • Hill Phoenix P074749F - page 22

    ...

  • Hill Phoenix P074749F - page 23

    ...

  • Hill Phoenix P074749F - page 24

    ...

  • Hill Phoenix P074749F - page 25

    A PPENDIX C: C ONTR OLLER I NFORMATION ...

  • Hill Phoenix P074749F - page 26

    dIXEL Operating Manual 1592020130 159202013 0 XR03_04CX GB 16.01.07. doc XR03CX – X R04CX DIGITA L C ONTROLLER XR03CX – XR04CX 1. CONTENTS 1. Conte nts __________________________________________________________________________ 1 2. Gener al war ni ng s ___________________________________________________________________ 1 3. Gener al des cri pt ...

  • Hill Phoenix P074749F - page 27

    dIXEL Operating Manual 1592020130 159202013 0 XR03_04CX GB 16.01.07. doc XR03CX – X R04CX Hy Differential: (0,1°C ÷ 25°C) Intervention differential f or set point. Compressor Cut IN is SET POINT + differential (Hy). Compressor Cut OUT is when the temperature reaches the set point. LS Mini mum SET POIN T: (-55°C÷SET/-58°F÷SET): Sets the min ...

  • Hill Phoenix P074749F - page 28

    dIXEL Operating Manual 1592020130 159202013 0 XR03_04CX GB 16.01.07. doc XR03CX – X R04CX Protection: IP20; Fron t a l pr o t e ct ion: IP65 Connections: Screw terminal block ≤ 2,5 mm 2 wiring. Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%; 230Vac ± 10%, 50/60Hz, 110Vac ± 10%, 50 / 60Hz Power absorption: 3VA max Displ ...

  • Hill Phoenix P074749F - page 29

    A PPENDIX D: U SER S ET P OINTS ...

  • Hill Phoenix P074749F - page 30

    ...

  • Hill Phoenix P074749F - page 31

    07/09 W ARRANTY HEREINAFTER REFERRED TO AS MANUF ACTURER FOURTEEN MONTH WARRANTY . MANUF ACTURER’S PRODUCT IS WARRANTED TO BE FREE FROM DEFECTS IN MA TERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF FOURTEEN MONTHS FROM THE DA TE OF ORIGINAL SHIPMENT . A NEW OR REBUIL T P ART TO REPLACE ANY DEFECTIVE P ART WILL BE PROVIDED ...

  • Hill Phoenix P074749F - page 32

    1925 Ruffin Mill Road, Colonial Heights, V A 23834 Due to our commitment to continuous improvement all specifications are subject to change without notice. Hill PHOENIX is a Sustaining Member of the American Society of Quality . Visit our web site at www .hillphoenix.com W ar ning Maintenance & Case Car e When cleaning cases the following must ...

Fabricant Hill Phoenix Catégorie Freezer

Les documents que nous recevons du fabricant de l'appareilHill Phoenix P074749F peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Hill Phoenix
- manuels d’utilisations P074749F
- fiches produit Hill Phoenix
- dépliants
- ou étiquettes-énergie Hill Phoenix P074749F
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Hill Phoenix P074749F.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Hill Phoenix P074749F, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Hill Phoenix P074749F. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Hill Phoenix P074749F.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Hill Phoenix P074749F, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Hill Phoenix P074749F par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Hill Phoenix P074749F.

Le manuel d’utilisation complet Hill Phoenix, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Hill Phoenix P074749F - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Hill Phoenix P074749F, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHill Phoenix P074749F qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Hill Phoenix P074749F - qui devraient nous aider dans les premières étapes lors de l'utilisation Hill Phoenix P074749F
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Hill Phoenix P074749F
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Hill Phoenix P074749F dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Hill Phoenix P074749F?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Hill Phoenix P074749F, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Hill Phoenix P074749F il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)