Manuel d’utilisation Draper 1000

22 pages 0.4 mb
Télécharger

Aller à la page of 22

Summary
  • Draper 1000 - page 1

    OWNER`S MANUAL 1000 MODEL STOVE Verified and tested following ULC S627 Standard by: Manufactured by : STOVE BUILDER INTERNATIONAL INC. . 1700, Léon-Harmel, Québec (Québec) G1N 4R9 Tel : (418 ) 527-3060 Fax : (418 ) 527-4311 w w w .osburn-mfg.com READ AND KEEP THIS MANUAL FOR REFERENCE 45126A ...

  • Draper 1000 - page 2

    1 TABLE OF CONTENTS INTRODUCTION ............................................................................................................................ 2 TECHNICAL SPECIFICATIONS ................................................................................................. 3 DOOR ADJUSTMENT ................................................. ...

  • Draper 1000 - page 3

    2 INTRODUCTION SBI INC., one of the most im portant wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wishes to help you get maximum satisfaction from your wood stove. In the pages that follow, we will give you advice on wood heating and controlled combustion as well as technica l specifications regarding inst ...

  • Draper 1000 - page 4

    3 TECHNICAL SPECIFICATIONS MODEL TEST STANDARDS HEAT OUTPUT RANGE SHIPPING WEIGHT COOK TOP HEIGHT COOK TOP WIDTH DEPTH MINIMUM NON-COMBUSTIBLE HEARTH SIZE FIREBOX SIZE DOOR OPENING SIZE RECOMMENDED LOG SIZE FLUE OUTLET OPTIONS O SBURN 1000 1. ULC S627 (CSA B366.2) RESIDENTIAL 2. UL 1482 RESIDENTIAL 6,000 - 41,000 BTU/HR BTU/HR OUTPUT WILL VARY WITH ...

  • Draper 1000 - page 5

    DOOR ADJUSTMENT In order for your stove to operate properly, the door shoul d be adjusted periodically to provide an air tight fit. To adjust: • Remove the lock pin (spring pin) by pulling and turning it using pliers ("wise grip") • Turn the handle counter clock wise one turn to increase pressure • Re-install the lock pin (spring pi ...

  • Draper 1000 - page 6

    5 INSTALLATION The Osburn Model 1000 is a freestanding space heater, for use in residential and mobile homes, providing installation and usage is according to the information given in this manual. SAFETY NOTICE • I F THIS STOVE IS NOT PROPERLY INSTALLED , A HOUSE FIRE MAY RESULT . T O REDUCE THE RISK OF FIRE , FOLLOW THE INSTALLATION INSTRUCTIONS ...

  • Draper 1000 - page 7

    FLOOR PROTECTOR Your wood stove should be placed on a non-com bustible surface. The floor protector should be under the stove, eighteen inches bey ond the front and eight inches beyond each side of the fuel loading and as h removal opening. If there is a horizontal section of chimney connector, the floor protector shoul d go under it and two inches ...

  • Draper 1000 - page 8

    In Australia , the corner clearance is 152 mm (6") when installed with the Benja Mk 2 flue system and fitted with a 889 mm (35") long polished stainless steel flue shield. FLUE SYSTEM CONFIGURATION A B C 889 mm Long Polished S/S or AL Flue Shield 4" (102 mm) 14" (356 m m) 6" (152 mm) REDUCED CLEARANCES 7 ...

  • Draper 1000 - page 9

    8 You may decrease the clearances by installing heat radiation shields between the walls or the ceiling and the stove. These heat radiation shields must be installed permanently, and can include sheet metal, a rigid non-co mbustible sheet or a masonry wall. Clearances of not less than 1" (25 mm) and not more than 3" (76 mm) between the bo ...

  • Draper 1000 - page 10

    9 CHIMNEY Your wood stove may be hooked up with a factory built or masonry chimney. If you are using a factory built chimney, it must comply with UL 103 or ULC S629 standards; therefore it must be a Type HT (2100°F). It is extremely important that it be installed according to the manufacturer's specifications. If you are using a masonry chimn ...

  • Draper 1000 - page 11

    CHIMNEY CONNECTOR (STOVE PIPE) Your chimney connector and chimney must have the same diameter as the stove outlet. If this is not the case, we recommend you contact your dealer in order to insure there will be no problem with the draught. The stove pipe must be made of aluminized or cold roll steel with a minimum thickness of 0.021" or 0.53 mm ...

  • Draper 1000 - page 12

    TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY: ROOF FLASHING 18" CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation MASONRY CHIMNEY: Cl ay l i n e r Thim b l e Cl ean out door 11 ...

  • Draper 1000 - page 13

    FACTORY BUILT THIMBLE: BRICK THIMBLE: 12 ...

  • Draper 1000 - page 14

    13 OUTSIDE COMBUSTION AIR Your OSBURN stove is approved to be insta lled with an outside air intake which is necessary for a mobile home. This type of installation is also required in air tight houses and houses with negative pressure problems. Y ou can purchase this option through your OSBURN dealer. Make sure to specify th is part number: #OA1050 ...

  • Draper 1000 - page 15

    14 Wood species Energy y ield (millions of BTU/cord) Oak 29 Sugar Maple 28 Beech 26 Yellow birch 25 Ash 24 High energy yield Elm 23 Larch (Tamarack) 23 Red Maple 23 Douglas red fir 23 Silver birch 22 Alder 18 Poplar 17 Medium energy yield Hemlock 17 Spruce 17 Pine 17 Bass 16 Low energy yield Fir 13 Data provided by Energy, Mines and Resources - Can ...

  • Draper 1000 - page 16

    15 If your wood hisses and water or vapour escapes at the ends of the piece, your wood is soaked or freshly cut. Do not use this wood in your stove. Large am ounts of creosote could be deposited in your chimney, creating pot ential conditions for a chimney fire. THE FIRST FIRES The fresh paint on your stove needs to be cured to preserve its quality ...

  • Draper 1000 - page 17

    16 WARNINGS • N EVER OVERFIRE YOUR STOVE . I F ANY PART OF THE STOVE STARTS TO GLOW RED , OVER FIRING IS HAPPENING . R EADJUST THE AIR INTAKE CONTROL AT A LOWER SETTI NG . • T HE INSTALLATION OF A LOG CRADLE IS NO T RECOMMENDED IN YOUR DROLET WOOD STOVE . • N EVER PUT WOOD ABOVE THE FIREBRICK LINING OF T HE FIREBOX . Use the following table t ...

  • Draper 1000 - page 18

    17 We strongly recommend that you install a m agnetic thermometer on your smoke exhaust pipe, approximately 18" above the stove. This thermometer will indicate the temperature of your gas exhaust fumes within the smoke exhaus t system. The ideal te mperature for these gases is somewhere between 275 o F and 500 o F. Below these temperatures, th ...

  • Draper 1000 - page 19

    18 • Inspect the glass regularly in order to detect any cracks. If you spot one, turn the stove off immediately. Do not abuse the glass door by striking or slamming shut. Do not use the stove if the glass is broken. • If the glass on your stove breaks, replace only with glazing supplied from the OSBURN dealer. Replace only with 255 mm x 450 mm ...

  • Draper 1000 - page 20

    PAINT Only clean your stove with a dry soft cl oth that will not harm the paint finish. If the paint becomes scratched or damaged, it is possible to give your wood stove a brand new look, by repai nting it with a 1200 o F heat resistant paint. For this purpose, simply scrub the surface to be repainted with fine s and paper, clean it properly, and a ...

  • Draper 1000 - page 21

    20 TROUBLESHOOTING Symptom Possible Cause Corrective Action I Smoke in room 1. Down draft 1. Upgrade chimney 2. Chimney blocked 2. Clean chimney 3. Chimney damper shut 3. Open or remove damper 4. Baffle out of position 4. Correctly position baffle 5. New paint is curing 5. Refer to instructions II Wood burns poorl y or is slow to start or no heat 1 ...

  • Draper 1000 - page 22

    21 1700, rue Léon-Harmel, Québec (Québec) G1N 4R9 tel. : (418) 527-3060 fax : (418) 527-4311 e- m ai l : t e ch @ os b ur n -m f g. c om we b s it e : h t t p: / /www. os b ur n -m f g. c om LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers bra ...

Fabricant Draper Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilDraper 1000 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Draper
- manuels d’utilisations 1000
- fiches produit Draper
- dépliants
- ou étiquettes-énergie Draper 1000
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Draper 1000.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Draper 1000, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Draper 1000. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Draper 1000.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Draper 1000, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Draper 1000 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Draper 1000.

Le manuel d’utilisation complet Draper, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Draper 1000 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Draper 1000, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDraper 1000 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Draper 1000 - qui devraient nous aider dans les premières étapes lors de l'utilisation Draper 1000
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Draper 1000
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Draper 1000 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Draper 1000?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Draper 1000, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Draper 1000 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)