Manuel d’utilisation Cleveland Range SGM-40-TR

22 pages 0.81 mb
Télécharger

Aller à la page of 22

Summary
  • Cleveland Range SGM-40-TR - page 1

    SE95033 Rev . 5 1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com Operators Manual Installation, Operation & Service Skillets Clev elan d ™ Enodis OPEN BASE & MODULAR GAS SKILLETS - MODELS SGL-30-TR SGM-30-TR SGL-40-TR SGM-40-TR BULLET FOOT (FRONT) ...

  • Cleveland Range SGM-40-TR - page 2

    FOR THE USER IMPOR T ANT Post in a prominent location, instructions to be followed in the event the user smells gas. This information shall be obtained by consulting your local gas supplier . Keep appliance area free and clear from combustibles. Do not obstruct the flow of combustion and ventilation air . All service must be performed by a qualifie ...

  • Cleveland Range SGM-40-TR - page 3

    ✘ 1 2 ✘ SER VICING IMPOR T ANT CAUTION DANGER GAS APPLIANCES For your safety K eep hands and utensils aw ay from moving parts and pinch points. W ear protective equipment when discharging hot product. Shut off power at main fuse disconnect prior to ser vicing. Inspect unit daily f or proper operation. Surf aces may be e xtremely hot! Use protec ...

  • Cleveland Range SGM-40-TR - page 4

    GENERAL Installation of the unit must be accomplished by qualified installation personnel working to all applicable local and national codes. Improper installation of unit could cause injury or damage. This equipment is built to comply with applicable standards for manufactur ers. Included among those approval agencies ar e: UL, A.G.A., NSF , ASME/ ...

  • Cleveland Range SGM-40-TR - page 5

    INST ALLA TION KEEP THE APPLIANCE AREA FREE AND CLEAR OF COMBUSTIBLE MA TERIALS. 1. Carefully r emove unit from carton or crate. Remove any packing material from unit. 2. A protective material has been applied to the stainless steel panels. NO TE : This material must be removed immediately after installation, as heat will melt the material and make ...

  • Cleveland Range SGM-40-TR - page 6

    CONTROL P ANEL OPERA TING INSTRUCTIONS ITEM # DESCRIPTION FUNCTION 1. On-Off Switch Main power switch for unit. 2. Power Indicator Light (Red) Indicates power is on. 3. Heat Indicator Light (Y ellow) T urns ON when system is calling for heat and OFF when system is satisfied. 4. T emperature Dial Regulates the surface temperature of the pan. 5. Powe ...

  • Cleveland Range SGM-40-TR - page 7

    ST ART UP PROCEDURE This appliance has been factory tested and adjusted under ideal conditions but, rough handling, low gas pressur e, altitude or variations in gas characteristics may requir e fine adjustment. All units are equipped with fixed orifices and do not requir e primar y air adjustment. LIGHTING INSTRUCTIONS NO TE : This appliance is equ ...

  • Cleveland Range SGM-40-TR - page 8

    CARE AND CLEANING Cooking equipment must be cleaned regularly to maintain its fast, efficient cooking performance and to ensure its continued safe, r eliable operation. The best time to clean is shortly after each use (allow unit to cool to a safe temperature). W ARNINGS ➩ Do not use detergents or cleansers that are chloride based or contain quat ...

  • Cleveland Range SGM-40-TR - page 9

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Range SGM-40-TR - page 10

    2 6 6 3 10 7 4 12 11 9 10 2 8 5 1 1 6 6 3 7 4 Hydraulic Jack Assemb ly KE000772 F or units built prior to Februar y 2005 (replaces old Jac k #s SK2381000 & SK00403) Hydraulic Jack Assemb ly KE000523 F or units built after F ebr uar y 2005 HYDRAULIC JACK ASSEMBLIES ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE600526 HYDRAULIC CYLINDER . . . . . . ...

  • Cleveland Range SGM-40-TR - page 11

    HYDRAULIC JACK ASSEMBLIES - HAND TIL T ITEM NO . P ART NO . DESCRIPTION QTY . 1 2381000 HYDRAULIC JACK ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 (NO LONGER A V AILABLE, USE KE000772) 5 F A95007-7 RET AINING RING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SGM-40-TR - page 12

    ACTUA TOR ASSEMBL Y - POWER TIL T (used prior to January , 2000) ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK2337499 ACTUA TOR MOUNTING BRACKET ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. SK23576 ...

  • Cleveland Range SGM-40-TR - page 13

    ACTUA TOR ASSEMBL Y - POWER TIL T (used after Jan uar y , 2000) 7 7 6 7 9 8 9 7 3 4 4 1 2 5 5 10 11 1 3 12 15 14 ITEM NO . P ART NO . DESCRIPTION QTY . 1. SK2346100 ACTUA TOR ASSY ., COMPLETE WITH ITEM 2 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE003242 ACTUA TOR ASSY ., WITH MANUAL OVERRIDE, COMPLETE WITH ITEMS 2 & 3 . . .1 2. SK23 ...

  • Cleveland Range SGM-40-TR - page 14

    New (added February 2005) KE600452 (Strainer) FI00351 (Bushing) FI05318-1 (Elbow , hose barb) ITEM NO . P ART NO . DESCRIPTION QTY . 1 2379100 HYDRAULIC ADAPTOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2379600 HYDRAULIC HOSE ASSY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SGM-40-TR - page 15

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2474101 POWER SWITCH (240V , USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . .1 2474100 POWER SWITCH (USED AFTER FEBRUARY 2001) . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2343500 POWER SWITCH (USED PRIOR TO FEBRUAR Y 2001) . . . . . . . . . . . . . . . . . . . . . . . .1 2 234 ...

  • Cleveland Range SGM-40-TR - page 16

    ITEM NO . P ART NO . DESCRIPTION QTY . 1. SE00119 T HERM OSTA T BOAR D ASSEMBLY (INCLUDES 2 - 14) 1 2. SK2142002 TEMPERA TURE SENSOR BOARD 1 3. SK2159300 INSULA TOR, THERMOST A T 1 4. SK2498399 P OTEN TIO ME T ER SHAFT ASSEMBLY (INCLUDES 5-10) 1 5. SK2167200 RET AINING RING, SP-NR #R1000-25 1 6. SK2167100 W ASHER, BOWED/SPRING 1 7. SK2167300 P ANEL ...

  • Cleveland Range SGM-40-TR - page 17

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE53838-32 TRANSFORMER - POWER TIL T - 110-120V/60 . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-31 TRANSFORMER - POWER TIL T - 208-240/60 . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53838-30 TRANSFORMER - POWER TIL T - 208-240/50 . . . . . . . . . . . . . . . . . . . . . . . . . .1 K ...

  • Cleveland Range SGM-40-TR - page 18

    ITEM NO. P ART NO. DESCRIPTION QTY . 1 KE55069-7 HI-LIMIT 1 2 2353900 BULB CLAMP 1 3 2354099 BULB SHIELD ASSY 1 4 F95 NUT 1 5 2345100 RTD SENSOR 1 6 2344900 SHIELD LINER 1 7 2345000 SHIELD 1 PLA TE ASSEMBL Y (used prior to January , 2000) ITEM NO. P ART NO. DESCRIPTION QTY . 1 F A21053 LOCK NUT 1/2-13 S.S. . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SGM-40-TR - page 19

    SPRING ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1 2452300 SPRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2381700 TURNBUCKLE BODY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 3 2374900 CONNECTING ROD R/H ...

  • Cleveland Range SGM-40-TR - page 20

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2359300 BACK TOP MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 2 2360101 REAR COMBUSTION SEAL - 40 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2360100 REAR COMBUSTION SEAL - 30 GAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range SGM-40-TR - page 21

    ITEM NO . P ART NO . DESCRIPTION QTY . 1 2373100 BURNER (NA T . GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. KE02410 BURNER (LP GAS) . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 for 30 gal., 10 for 40 gal. 2 KE55277-1 ORIFICE, (NA T . GAS), 2000 FT . . . . . . . . . . . . . . . . . . .7 for 30 ...

  • Cleveland Range SGM-40-TR - page 22

    N OT E : ANY MAINTENANCE OR SERVICE INVOL VING DISSASSEMBL Y OF COMPONENTS SHOULD BE MADE BY A QUALIFIED SERVICE TECHNICIAN. ENSURE GAS, ELECTRICAL AND W A TER SUPPL Y (IF APPLICABLE) TO THE APPLIANCE ARE SHUT OFF Y ou have purchased the finest commer cial cooking equipment available anywhere. Like any other fine, precision built piece of equipment ...

Fabricant Cleveland Range Catégorie Fryer

Les documents que nous recevons du fabricant de l'appareilCleveland Range SGM-40-TR peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cleveland Range
- manuels d’utilisations SGM-40-TR
- fiches produit Cleveland Range
- dépliants
- ou étiquettes-énergie Cleveland Range SGM-40-TR
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cleveland Range SGM-40-TR.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cleveland Range SGM-40-TR, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cleveland Range SGM-40-TR. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cleveland Range SGM-40-TR.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Cleveland Range SGM-40-TR, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cleveland Range SGM-40-TR par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cleveland Range SGM-40-TR.

Le manuel d’utilisation complet Cleveland Range, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cleveland Range SGM-40-TR - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cleveland Range SGM-40-TR, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCleveland Range SGM-40-TR qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cleveland Range SGM-40-TR - qui devraient nous aider dans les premières étapes lors de l'utilisation Cleveland Range SGM-40-TR
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cleveland Range SGM-40-TR
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cleveland Range SGM-40-TR dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cleveland Range SGM-40-TR?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cleveland Range SGM-40-TR, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cleveland Range SGM-40-TR il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)