    AS-H40Y - 12kW AS-H50Y - 15kW AS-H60Y - 18kW AL TO Hea t Pump inst alla tion manu al F1-F7 ...

  • Sigma AS-H60Y - page 2

    1 CUSTOMER NAME........................................................................ POOL DEALER.............................................................................. DA TE INST ALLED.......................................................................... SERIAL NO........................................................................ ...

  • Sigma AS-H60Y - page 3

    HEA T PUMP- AS-H40Y 12kW 2 ...

  • Sigma AS-H60Y - page 4

    3 HEA T PUMP- AS-H50Y (15kW) & AS-H60 (18kW) ...

  • Sigma AS-H60Y - page 5

    INST ALLA TION AND SITING Prior to installing your heat pump:- All heat pumps are factory assembled and tested prior to delivery . Please check for any external damage especially to the evaporator fins, please diagram below . Do not be concerned about minor damage or indent ations to the fins (especially where the fan unit is mounted) as it will no ...

  • Sigma AS-H60Y - page 6

    5 PLUMBING Alto heat pumps are supplied with 1.5" BSP parallel threads, male. We strongly recommend a 1.5" female socket union is applied to inlet/outlets for future draining and servicing of the appliance. Alto heat pumps must be inst alled in the return line after the filter . If an existing heater or back-up heater has been installed t ...

  • Sigma AS-H60Y - page 7

    N L ON OFF CONT A CTOR 12 HEA TER Red Black OUTLET FLOW SWITCH OPERA TION WA TER FLOW FROM PUMP SOCKET UNION TEE INLET OFF ON Alternat ive w irin g route SOCKET UNION RETURN W A TE R FLOW TO POOL 1. Insert reducing bushes (provided) into 1.5” T ee using suitable adhesive. 2. Connect 1.5” T ee to socket union adjacent to Inlet on heat pump. T ee ...

  • Sigma AS-H60Y - page 8

    7 Ball Va l v e BACK WASH FILTER FIL TER Pool Position for option al Erosion Fe eder Non-Retur n V alve Back-Up Heater if required Condensat e W ater to waste PUMP Female/ Threade d Socket Union Drw .1 Recommended plumbing layout for a st andard heat pump installation. Drw .2 Recommended plumbing layout when incorporating Solar Heating. If an incre ...

  • Sigma AS-H60Y - page 9

    Ball Va l v e BACKW ASH FIL TER FIL TER Pool Non-R etu rn Valve Back-Up Heater if required Condensate W ater to waste PUMP Female/ Threaded Socket Union to be applied on all inlet/outlets Position for optional Erosion Feeder Ball Va l v e Ball Va l v e Condensate W ater to waste required or Erro sion Feede r if instal led Drw .4 Recommended plumbin ...

  • Sigma AS-H60Y - page 10

    9 ELECTRICAL CONNECTION & CIRCUIT DIAGRAM IMPORT ANT . It is recommended that all electrical supplies and connections are carried out by a qualified electrician , in accordance with I.E.E. standards, latest issue, or local codes of practice as applicable. Also recommended is a protected supply to incorporate fuses or motor type circuit breaker ...

  • Sigma AS-H60Y - page 11

    1. When electric supply is connected the ‘Run’ power light will be on and the display panel will display the current water temperature. ie.10 H = 10°C. 2. On/OFF button to turn heater on and off. 3. The ‘set’ button is used to set the F1-6 functions ie.water temperature, defrosting cycle and defrosting time etc. see pages 1 1-12 PLEASE REA ...

  • Sigma AS-H60Y - page 12

    11 When the ON/OFF buttons is pressed for the first time, the display panel will display the current water temperature and the desired pool temperature. eg. the display may read 10 40 ----- 10 is the current water temperature 10°C and 40 is the desired water temperature 40°C. ADJUSTING THE POOL W A TER TEMPERA TURE Using the up and down buttons, ...

  • Sigma AS-H60Y - page 13

    When the SET button is pressed for the fourth time, the display p anel will display:- F4 : Operation Mode. F4 C : Cooling Mode. F4 H : Heating Mode When the SET button is pressed for the fif th time, the display panel will display:- F5 : The defrosting temperature of the evaporator pipe . The recommended temperature setting for the UK should be set ...

  • Sigma AS-H60Y - page 14

    13 RED area RED area area RED area RED area area RED area RED area area After the water heater has been running for more than 24 hrs, it should be running at full capacity . The PSI reading should be in the region 150 -200. If you want to make the heat pump run more efficiently the water flow should be adjusted by checking the pressure meter displa ...

  • Sigma AS-H60Y - page 15

    E1 : the water temperature sensor is not working correctly . E2 : the tube sensor is not working correctly . Please contact your dealer . E3 : Pool filtration is running but water flow is not sensed. ‘Flow Switch’ may not be working properly or there is a lack of water flow . Backwash filter and check suction lines (Skimmer(s) & Main Drain( ...

  • Sigma AS-H60Y - page 16

    15 AUT O REST ART AND DEFROSTING FUNCTION AUTO REST ART FUNCTION The Alto water heat pump has an auto rest art function. When the power supply is switched off accidentally , it will automatically save the operation mode. When the power supply is restored, the unit will automatically restart af ter five minutes and operate in the same working mode. ...

  • Sigma AS-H60Y - page 17

    WINTERISING / ST ART -UP procedure - ALL MODELS W A TER CHEMISTR Y The following water quality must be maintained at all times to prevent premature corrosion. It is recommended that your water balance is checked and balanced by a pool professional. Y our warranty does not cover for damaged caused by poor water chemistry and neglect. pH: 7.2 -7.6 T ...

  • Sigma AS-H60Y - page 18

    17 AL T O W ARRANTY POLICY This voluntary policy is supplement al to and in no way affects any st atutory rights which the customer may have. 1 W arranties 1.1 Paramount Pools warrants the Alto Heat Pump for a period of one (1) year from the date installed for both part s and labour . 1.2 At the end of the first year the following warranties apply ...

  • Sigma AS-H60Y - page 19

    HEA T PUMP SER VICE An Alto heat pump should give you many years trouble free service. However , to obtain the maximum efficiency from your heater Alto recommend that your heater is checked and serviced every 12 months. Service & extended warranty packages are available from a UK Service Agent (see contact det ail below). HEA T PUMP BREAKDOWN I ...

  • Sigma AS-H60Y - page 20

    Model No. AS-H40Y AS-H50Y AS-H60Y 12kW 15kW 18kW Heating Capacity (Btu) 40000 50000 60000 Cooling Capacity (Btu) 35000 42000 55000 Rated Input (W) Heating 2540 3185 3790 Cooling 2465 3020 3900 PTC Power (W) -------- -------- -------- COP for Heating (w/w) 4.42 4.40 4.44 (at 20 °C ambient air temperature) Refrigerant R407C R407C R407C Power Supply ...

Fabricant Sigma Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilSigma AS-H60Y peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sigma
- manuels d’utilisations AS-H60Y
- fiches produit Sigma
- dépliants
- ou étiquettes-énergie Sigma AS-H60Y
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sigma AS-H60Y.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sigma AS-H60Y, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sigma AS-H60Y. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sigma AS-H60Y.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sigma AS-H60Y, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sigma AS-H60Y par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sigma AS-H60Y.

Le manuel d’utilisation complet Sigma, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sigma AS-H60Y - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sigma AS-H60Y, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSigma AS-H60Y qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sigma AS-H60Y - qui devraient nous aider dans les premières étapes lors de l'utilisation Sigma AS-H60Y
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sigma AS-H60Y
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sigma AS-H60Y dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sigma AS-H60Y?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sigma AS-H60Y, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sigma AS-H60Y il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)