    SY STEM CONFIGURA TION for S900II robots Software V ersion 1.0 Corporate Office: 412.312.6000 l Instant Access 24/7 (Parts and Service): 800.458.1960 l Parts and Service: 814.437.6861 USERGUIDE www .conairnet.com W ARNING - Reliance on this Manual Could Result in Se vere Bodily Injury or Death! This manual is out-of-date and is provided only f or i ...

  • Conair S900II - page 2

    ...

  • Conair S900II - page 3

    System Configuration S900II I – Memory 1 01T01350_0 2.2.98 I – MEMOR Y I – 1. Accessing the memory After accessing ”Memory Management” by pressing [Memo_M] (programming menu), pressing the [M_Read] key gives access to the read (or modification) function of the user and system RAM or EEPROM memory (at the address of the memory box by defau ...

  • Conair S900II - page 4

    System Configuration S900II I – Memory 2 01T01350_0 2.2.98 * The function keys F1 to F5 :  [Address] to change the address.  [Modif] to change the contents of the memory area displayed (word).  [Search] to search for a particular word (e.g. : F A1B)  [Print] to print the memory contents from the displayed address (in order to search f ...

  • Conair S900II - page 5

    System Configuration S900II I – Memory 3 01T01350_0 2.2.98 I – 2. Memory areas I – 2. 1.Data saved in RAM (512 K x 8) 0 to 7 FFFF Addr ess in Hexadecimal Contents 00000 V ariables used by Philips (BOOT) 027FF 02800 “Fixed” SEPRO variables, see table below for details of the variables 0A4FF 0A500 SEPRO parameters in RAM 0B2FF 0B300 PRG sto ...

  • Conair S900II - page 6

    System Configuration S900II I – Memory 4 01T01350_0 2.2.98 I – 2. 2.Program addr essing in memory The PRG and PLC programs are stored in the RAM memory , starting from the address 0xB300. The maximum length of a PRG is 12286 bytes ; 4096 bytes for a PLC. This area reserved for the permanent storage varies depending on the option 32 to 128 Kbyte ...

  • Conair S900II - page 7

    System Configuration S900II I – Memory 5 01T01350_0 2.2.98 Block number Addr ess in Hexadecimal Contents F10 C0000 Messages in language 1 F10 CEBEF F10 CEBF0 Messages in language 2 F10 DD7DF F10 DD7E0 Font robot 1 F10 DE7EF F10 DE7F0 Font robot 2 7th block F10 DF7FF F10 DF800 Messages Code converter table IMM 1 F10 DF9FF F10 DF A00 Code converter ...

  • Conair S900II - page 8

    System Configuration S900II I – Memory 6 01T01350_0 2.2.98 I – 3. Specific information These are directly accessed using the Memory Read function followed by the request [Address] and a letter : – to access the memory area containing the passwords. – to access the memory area containing the serial number and the type of robot. 15 0 Password ...

  • Conair S900II - page 9

    System Configuration S900II II – Instruction codes 7 01T01350_0 2.2.98 II – INSTRUCTION CODES II – 1. Part programs T ype of Instruction Display Codop (hexadecimal) Examples ACTION ACT 00 (to 99) * A000 [oper . 16 bits] A000000C = ACT12 OUTPUT OUT 000 (to 255) * A001 [oper . 16 bits] A0010050 = OUT080 INPUT IN 000 (to 255) A002 [oper . 16 bit ...

  • Conair S900II - page 10

    System Configuration S900II II – Instruction codes 8 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples VEL.X WW_*nn B050 0000 [oper .12bits] B0500042 = VEL.X WW066 VEL.Y WW_*nn B051 0000 [oper .12bits] B0510043 = VEL.Y WW067 VEL.Z WW_*nn B052 0000 [oper .12bits] B0520042 = VEL.Z WW066 VEL.B WW_*nn B053 0000 [oper .12bits ...

  • Conair S900II - page 11

    System Configuration S900II II – Instruction codes 9 01T01350_0 2.2.98 MOTORIZED MOTIONS SLOW APPROACH SLA.X 001 to 100 B020 [oper . 16 bits] B0200026 = SLA.X 026 in % of the maximum SLA.Y 001 to 100 B021 [oper . 16 bits] B0210034 = SLA.Y 034 parametered speed SLA.Z 001 to 100 B022 [oper . 16 bits] B0220090 = SLA.Z 090 SLA.B 001 to 100 B023 [oper ...

  • Conair S900II - page 12

    System Configuration S900II II – Instruction codes 10 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples CHECKING X.CTL_R Angle C130[oper .8bits][oper .24bits] C13000000664=X.CTL.R00163.6 Y .CTL_R Angle C131[oper .8bits][oper .24bits] C131000F423F=Y .CTL.R9999.9 Z.CTL_R Angle C132[oper .8bits][oper.24bits] C13200000320=Z. ...

  • Conair S900II - page 13

    System Configuration S900II II – Instruction codes 1 1 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples RELA TIVE X.REL_R WW *nn C320 [oper . 16 bits] C3200001 = X.REL.R WW01 Y .REL_R WW *nn C321 [oper . 16 bits] Z.REL_R WW *nn C322 [oper . 16 bits] B.REL_R WW *nn C323 [oper . 16 bits] C.REL_R WW *nn C324 [oper . 16 bit ...

  • Conair S900II - page 14

    System Configuration S900II II – Instruction codes 12 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples LINEAR POS_ANA X = POS ANA + distance C060 [oper . 32 bits] Y = POS ANA + distance C061 [oper . 32 bits] Z = POS ANA + distance C062 [oper . 32 bits] B = POS ANA + distance C063 [oper . 32 bits] C = POS ANA + distance ...

  • Conair S900II - page 15

    System Configuration S900II II – Instruction codes 13 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples ROT A TING POS_ANA X = POS ANA + angle C160 [oper . 32 bits] Y = POS ANA + angle C161 [oper . 32 bits] Z = POS ANA + angle C162 [oper . 32 bits] B = POS ANA + angle C163 [oper . 32 bits] C = POS ANA + angle C164 [oper ...

  • Conair S900II - page 16

    System Configuration S900II II – Instruction codes 14 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples TEST , CONDITIONS . 1 Operand on Bit IF BIT 000 (to 127) D000 [oper . 16 bits] IF/BIT 000 (to 127) D010 [oper . 16 bits] on Output IF OUT 000 (to 255) D001 [oper . 16 bits] IF/OUT 000 (to 255) D01 1 [oper . 16 bits] on ...

  • Conair S900II - page 17

    System Configuration S900II II – Instruction codes 15 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples * on WW ord (32 bits) IF WWRD 000 (to 127) D320 [oper . 16 bits] –> 1st Operand IF/WWRD 000 (to 127) D330 [oper . 16 bits] with decimal value = 00000000 (to 09999999) D500 [oper . 32 bits] > = 00000000 (to 0999 ...

  • Conair S900II - page 18

    System Configuration S900II II – Instruction codes 16 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples with Inputs (modulo 16) = IN 000 (to 1 12) D930 [oper . 16 bits] > = IN 000 (to 1 12) D931 [oper . 16 bits] < = IN 000 (to 1 12) D932 [oper . 16 bits] AND IN 000 (to 1 12) D933 [oper . 16 bits] with W ord (16 bit ...

  • Conair S900II - page 19

    System Configuration S900II II – Instruction codes 17 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples with Counter = CNT 00 (to 15) D720 [oper . 16 bits] + CNT 00 (to 15) D721 [oper . 16 bits] – CNT 00 (to 15) D722 [oper . 16 bits] x CNT 00 (to 15) D723 [oper . 16 bits] / CNT00 (to 15) D724 [oper . 16 bits] AND CNT 0 ...

  • Conair S900II - page 20

    System Configuration S900II II – Instruction codes 18 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples with Inputs (modulo 16) = IN *nn D830 [oper . 16 bits] + IN *nn D831 [oper . 16 bits] – IN *nn D832 [oper . 16 bits] *nn = 00 to 1 12 x IN *nn D833 [oper . 16 bits] and 136 to 240 / IN *nn D834 [oper . 16 bits] AND I ...

  • Conair S900II - page 21

    System Configuration S900II II – Instruction codes 19 01T01350_0 2.2.98 T ype of Instruction Display Codop (hexadecimal) Examples with Inputs (modulo 16) = IN 000 (to 1 12) DA30 [oper . 16 bits] + IN 000 (to 1 12) DA31 [oper . 16 bits] – IN 000 (to 1 12) DA32 [oper . 16 bits] x IN 000 (to 1 12) DA33 [oper . 16 bits] / IN 000 (to 1 12) DA34 [ope ...

  • Conair S900II - page 22

    System Configuration S900II II – Instruction codes 20 01T01350_0 2.2.98 II – 2. PLC programs T ype of Instruction Display Codop (hexadecimal) PROG.PLC xx header (num) PLC xx FC [oper . 16 bits] TEST CONDITION IF ... See part programs INITIALISA TION SET ... See part programs RST ... INC ... DEC ... COMP ARISON xxxx > = xxxx CMP 0000 (to 0015 ...

  • Conair S900II - page 23

    System Configuration S900II III – Pr ogram codes 21 01T01350_0 2.2.98 III – PROGRAM CODES III – 1. Declaration of programs, subr outines and PLCs " Header codes of PRG, SP ,..., SR, PLC G F9b xn = Main program G b = 0, standard PRG (encoded on 15 bits) b = 1 , SAP PRG (encoded on 15 bits) G F Ann = STD, STK.. // subroutine (see stacking ...

  • Conair S900II - page 24

    System Configuration S900II III – Pr ogram codes 22 01T01350_0 2.2.98 III – 2. Subroutine and pr ogram calls " SPECIFIC codes for SP , SR, PLC as an instruction G E000 [oper . 16 bits] : Standar d SP SP nn Lmm (nn = 01 to 40) (mm = 00 to 99) Regular Stacking SP SP nn D Lmm (or I Lmm) (nn = 41 to 60) (mm = 00 to 99) General Stacking SP SP n ...

  • Conair S900II - page 25

    System Configuration S900II IV – V ariable addr essing 23 01T01350_0 2.2.98 IV – V ARIABLE ADDRESSING IV – 1. Output – OUT – Accessible in read and write. Number (logical address) Physical address Structures / Functions OUT 000 OUT 255 28A0 299F 2 A1D OUT 125 not used Forcing (Extended monitor) Continuous status (See Param. No 14) IV – ...

  • Conair S900II - page 26

    System Configuration S900II IV – V ariable addr essing 24 01T01350_0 2.2.98 IV – 4. 16 bits user and system words – WRD – WRD 0000 2AA0 WRD 0031 2ADF WRD 0032 2AE0 WRD 0063 2B1E WRD 0064 2B20 WRD 0079 2B3F WRD 0080 2B40 WRD 0095 2B5F WRD 0096 2B60 WRD 4096 3A9F 32 user W ords (read/write) with no predefined functions. B15 0 16 bit structure ...

  • Conair S900II - page 27

    System Configuration S900II IV – V ariable addr essing 25 01T01350_0 2.2.98 IV – 6. Counters Each address corresponds to a 16 bit structure in the memory . 2 B4x CNT0008 WRD0088 . values from 0000 to 9999 in decimal . values from 0000 to FFFF in hexadecimal b15 b0 x = bit number in hexadecimal (e.g.: CNT 0008, address = 2 B50). – Standard cou ...

  • Conair S900II - page 28

    System Configuration S900II V – CPU fault signalling 26 01T01350_0 2.2.98 V – CPU F AUL T SIGNALLING V – 1. Flashing Leds These signal a CAN network fault by displaying the problem number in binary on the LEDs at the bottom of the CPU, and the node number (if concerned) on the LEDs at the top if the pendant is not functioning. 30 1 = CAN driv ...

  • Conair S900II - page 29

    System Configuration S900II V – CPU fault signalling 27 01T01350_0 2.2.98 V – 2. Fixed Leds These signal a fault when powering up by giving the problem number in binary on the LEDs at the bottom of the CPU, and the node number (if concerned) on the LEDs at the top if the pendant is not functioning. 1 = Problem with recovering the parameters in ...

  • Conair S900II - page 30

    parameter 175 2 in the case of restart with programmed delay System Configuration S900II VI – IMM Anticipated Restart 28 01T01350_0 2.2.98 VI – IMM ANTICIP A TED REST ART " Parameter 174 : type of IMM anticipated restart G 0 : no anticipated restart G 1 : anticipated restart G 2 : programmed delay anticipated restart –> WWRD 63 progra ...

  • Conair S900II - page 31

    System Configuration S900II VI – IMM Anticipated Restart 29 01T01350_0 2.2.98  Safety circuit principle. A hard–wired circuit controls the respective positions of the moving mould (“MO” = Mould Open signal) and of the robot (“ZBD” = Arm Free Area / “ZHM” = Outside Mould Area signal). The output of this hard–wired circuit (”MO ...

  • Conair S900II - page 32

    System Configuration S900II VI – IMM Anticipated Restart 30 01T01350_0 2.2.98 IF IN XX SET WORD 62 = 200 Until a parameter for the control input for the anticipated restart safety circuit is integrated into the software, this input must be monitored and a fault must be generated using the monitoring PLC. RELANCE ANTICIPEE NON CONFORME : in French ...

Fabricant Conair Catégorie Robotics

Les documents que nous recevons du fabricant de l'appareilConair S900II peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Conair
- manuels d’utilisations S900II
- fiches produit Conair
- dépliants
- ou étiquettes-énergie Conair S900II
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Conair S900II.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Conair S900II, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Conair S900II. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Conair S900II.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Conair S900II, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Conair S900II par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Conair S900II.

Le manuel d’utilisation complet Conair, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Conair S900II - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Conair S900II, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lConair S900II qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Conair S900II - qui devraient nous aider dans les premières étapes lors de l'utilisation Conair S900II
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Conair S900II
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Conair S900II dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Conair S900II?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Conair S900II, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Conair S900II il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)