Manuel d’utilisation Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72

20 pages 0.81 mb
Télécharger

Aller à la page of 20

Summary
  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 1

    SERVICE MANUAL For additional information on Vulcan-Hart or to locate an authorized parts and service provider in your area, visit our website at www.vulcanhart.com F35628 (10-04) - NOTICE - This manual is prepared for the use of trained Vulcan Service Technicians and should not be used by those not properly qualified. If you have attended a Vulcan ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 2

    — 2 — F35628 (10-04) T ABLE OF CONTENTS GENERAL ............................................................................................................................... ......... 3 Introduction ............................................................................................................................... .3 Installation . ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 3

    — 3 — F35628 (10-04) INTRODUCTION Procedures in this manual will apply to all models unless specified. Pictures and illustrations can be of any model unless the picture or illustration needs to be model specific. All models are equipped with 30,000 BTU/HR burners as standard equipment. One burner is used for every 12 inches of griddle surface. ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 4

    — 4 — F35628 (10-04) REMOV AL AND REPLACEMENT OF P ARTS COMPONENT LOCATION Figure A Bullnose Deflector Plate Heat Shield Control Plate Control Panel Grease Drawer Griddle Flame Switch Ignitor Module Dual Solenoid Pilot Solenoid Dual Solenoid Ignitor Module Panel Connector Flame Switch Back Panel ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 5

    — 5 — F35628 (10-04) CONTROL PANEL WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the two screws securing the control panel. One screw is located at each end of the control panel. 2 . Pull the control panel forward and disconnect the electrical connector near the right end. Figure B 3. ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 6

    — 6 — F35628 (10-04) POWER ON/OFF SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the power ON/OFF switch. 3. Squeeze the switch retainer and slide the switch out through the front of the control panel. Figure E 4. Reverse pr ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 7

    — 7 — F35628 (10-04) FLAME SWITCH WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the control panel. 2. Label and disconnect the wires to the flame switch. 3. Remove the two screws securing flame switch to control plate. 4. Remove sensor from the pilot assembly. Sensor can be accessed fr ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 8

    — 8 — F35628 (10-04) GAS BURNER WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. 1. Remove the back panel. 2. Cut shipping tie from burner. 3. To remove the burner, reach through the back of the unit and lift the burner up over the guide screw then pull the burner out through the back of the unit. ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 9

    — 9 — F35628 (10-04) PILOT WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AND FOLLOW LOCKOUT / TAGOUT PROCEDURES. WARNING: SHUT OFF THE GAS BEFORE SERVICING THE GRIDDLE. 1. Remove control panel and heat shield for visual access of the pilot. 2. Reaching underneath the front of the griddle remove the pilot tube fitting and disengage the ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 10

    — 10 — F35628 (10-04) WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TEST OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER AND FOLLOW LOCKOUT / TAGOUT PROCEDURES, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST. THERMOSTAT CAL ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 11

    — 11 — F35628 (10-04) 2. Units for operation of natural or propane gas are also equipped with a factory preset pressure regulator with an outlet pressure of 5” W.C. (Water Column) for natural gas supply and 10” W.C. for propane gas supply, and should not require further adjustment. 3. The burners and pilot flames may be observed through rou ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 12

    — 12 — F35628 (10-04) COMPONENT DESCRIPTION Power Switch ON/OFF – Switch turns power ON or OFF. Ignition Control Module – Provides ignition spark. Turned on when ON/OFF switch is set to the ON position and turned off when flame switch closes. Burner On Lights – Illuminates to indicate burner is turned on. Thermostats – Turns burner on a ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 13

    — 13 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 24” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723526-1 ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 14

    — 14 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 36” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723527-1 ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 15

    — 15 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 48” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723528-1 ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 16

    — 16 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 60” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723529-1 ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 17

    — 17 — F35628 (10-04) SCHEMA TIC DIAGRAMS Schematic Drawing for 72” Griddle B NOTE: 1. USE SUPPLY WIRES SUITABLE FOR 200 ° C OR EQUIVALENT EMPLOYER DES FILS D’ALIMENTATION ADEQUATS 200 ° C OR EQUIVALENT 2. HARNESS PART NO. 723530-1 ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 18

    — 18 — F35628 (10-04) TROUBLESHOOTING GUIDE SYMPTOM Indicator light fails to light when power ON/OFF switch is set to ON position Indicator light fails to go out when power ON/OFF switch is set to the OFF position Griddle does not heat when thermostat is turned on Igniter stays on too long after pilot flame is established Igniter fails to light ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 19

    — 19 — F35628 (10-04) TROUBLESHOOTING GUIDE REMEDY Check operation of pilot valve Purge gas lines Check that gas supply is on Check and repair wire connection Check for obstruction or wrong size orifice Realign pilot and igniter Check and repair wire connection Correct air flow Check for obstruction or wrong size orifice Realign pilot and ignit ...

  • Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - page 20

    FORM 35628 (10-04) PRINTED IN U.S.A. ...

Fabricant Vulcan-Hart Catégorie Griddle

Les documents que nous recevons du fabricant de l'appareilVulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vulcan-Hart
- manuels d’utilisations 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G6
- fiches produit Vulcan-Hart
- dépliants
- ou étiquettes-énergie Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72.

Le manuel d’utilisation complet Vulcan-Hart, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vulcan-Hart 924RE, 936RE, 948RE, 960RE, 972RE, ML-135221-00G24, ML-135222-00G36, ML-135223-00G48, ML-135224-00G60, ML-135225-00G72 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)