Manuel d’utilisation Lincoln Electric LN-9 SVM127-A

135 pages 1.49 mb
Télécharger

Aller à la page of 135

Summary
  • Lincoln Electric LN-9 SVM127-A - page 1

    SVM127-A November , 1996 Safety Depends on Y ou Lincoln arc welding equipment is designed and built with safety in mind. However , your overall safety can be increased by proper installation. . . and thoughtful operation on your part. DO NOT INST ALL, OPERA TE OR REP AIR THIS EQUIPMENT WITHOUT READ- ING THIS MANUAL AND THE SAFETY PRECAUTIONS CON- T ...

  • Lincoln Electric LN-9 SVM127-A - page 2

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY i i LN-9 Wire Feeder FOR ENGINE powered equipment. 1.a. T urn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, ...

  • Lincoln Electric LN-9 SVM127-A - page 3

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY ii ii LN-9 Wire Feeder ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I ...

  • Lincoln Electric LN-9 SVM127-A - page 4

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iii iii LN-9 Wire Feeder FOR ELECTRICALL Y powered equipment. 8.a. T urn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes ...

  • Lincoln Electric LN-9 SVM127-A - page 5

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC SAFETY iv iv LN-9 Wire Feeder PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- ante ...

  • Lincoln Electric LN-9 SVM127-A - page 6

    MASTER T ABLE OF CONTENTS FOR ALL SECTIONS v v LN-9 Wire Feeder Page Safety .................................................................................................................................................i-iv Installation ............................................................................................................... ...

  • Lincoln Electric LN-9 SVM127-A - page 7

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - INST ALLA TION SECTION - Section A-1 Section A-1 LN-9 Wire Feeder Installation ................................................................................................................................Section A T echnical Specifications .. ...

  • Lincoln Electric LN-9 SVM127-A - page 8

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-2 A-2 TECHNICAL SPECIFICA TIONS — LN-9 INPUT POWER Supplied by power source: 1 15 V AC, 50/60 Hz., 350 V A WIRE FEED SPEED 50 to 600 inches per minute (1.27 to ...

  • Lincoln Electric LN-9 SVM127-A - page 9

    INST ALLING THE LN-9N and LN-9S 2-ROLL AND 4-ROLL MODELS A TT ACHING THE WIRE REEL ST AND Both 2-Roll and 4-Roll LN-9 model wire feeders are shipped without a wire reel stand. The screws and washers for mounting a wire reel stand are included with the LN-9 (fastened in their respective mounting holes). T o attach a stand: 1. Remove the three 3/8&qu ...

  • Lincoln Electric LN-9 SVM127-A - page 10

    ROUTING THE ELECTRODE The electrode supply may be either from reels, Readi- Reels, spools, or bulk packaged drums or reels. Observe the following precautions: • The electrode must be routed to the wire feed unit so that the bends in the wire are at a minimum. The force required to pull the wire from the reel into the wire feed unit must be kept a ...

  • Lincoln Electric LN-9 SVM127-A - page 11

    CONNECTING THE POWER INPUT CABLE ASSEMBL Y TO THE LN-9NE or LN-9SE The hand crank drive rolls will feed all the wires used on the extension. The rolls have been stenciled for identification. 1. Position the extension assembly cable so that the amphenol plug with the threads on its O.D. can be attached to the amphenol end of the power input cable. A ...

  • Lincoln Electric LN-9 SVM127-A - page 12

    7. If using welding currents over 450 amperes, con- nect a length of 1/0 cable between the brass block on the hand crank and the input strap located in the wire drive unit. T ape this cable to the extension assembly . Proper cable lengths are as follows: 22-1/2 ft. extension 26’ M5906-106 45 ft. extension 46’ M5906-104 8. A handle is provided a ...

  • Lincoln Electric LN-9 SVM127-A - page 13

    CONNECTING THE POWER INPUT CABLE ASSEMBL Y TO POWER SOURCES T urn input supply power to the power source OFF before connecting the LN-9 or LN-9F wire feeder . Connect to an appropriate Lincoln power source as fol- lows: 1. If using a multipurpose source (such as the DC- 250, DC-400 and DC-600), be sure it is properly set for the welding process bei ...

  • Lincoln Electric LN-9 SVM127-A - page 14

    INST ALLA TION A-8 A-8 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.5 – CONNECTION OF LN-9 TO DC-250, DC-400, AND CV/CVI POWER SOURCES Above diagram shows electrode connected positive. T o change ...

  • Lincoln Electric LN-9 SVM127-A - page 15

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-9 A-9 LN-9 Wire Feeder FIGURE A.6 – CONNECTION OF LN-9 TO DC-600 POWER SOURCES Above diagram shows electrode connected positive. T o change polarity , turn pow ...

  • Lincoln Electric LN-9 SVM127-A - page 16

    INST ALLA TION A-10 A-10 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.7 – CONNECTION OF LN-9 TO DC-1000 POWER SOURCES Above diagram shows electrode connected positive. T o change polarity , turn ...

  • Lincoln Electric LN-9 SVM127-A - page 17

    INST ALLA TION A-11 A-11 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE A.8 – CONNECTION OF LN-9 TO PULSE POWER 500 POWER SOURCES Above diagram shows electrode connected positive. T o change polarity ...

  • Lincoln Electric LN-9 SVM127-A - page 18

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC INST ALLA TION A-12 A-12 LN-9 Wire Feeder MACHINE GROUNDING LN-9 wire feeders are grounded to the power source through the input cable. The power source grounding cable must be p ...

  • Lincoln Electric LN-9 SVM127-A - page 19

    CONNECTING THE GUN CABLE T O THE WIRE FEEDER A variety of gun and cable assemblies are available for the LN-9 models. See the Accessories section of this manual. Lay the cable out straight. Insert the connector on the welding conductor cable into the brass conductor block on the front of the wire drive unit. See Figure A.9. Make sure the connector ...

  • Lincoln Electric LN-9 SVM127-A - page 20

    NOTES A-14 A-14 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric LN-9 SVM127-A - page 21

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section B-1 Section B-1 LN-9 Wire Feeder T ABLE OF CONTENTS - OPERA TION SECTION - Operation .................................................................................................................................Section B Safety Instructions .............. ...

  • Lincoln Electric LN-9 SVM127-A - page 22

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC B-2 B-2 LN-9 Wire Feeder SAFETY INSTRUCTIONS Read and understand this entire section of operating instructions operating the machine. ELECTRIC SHOCK can kill. • Do not touch el ...

  • Lincoln Electric LN-9 SVM127-A - page 23

    GENERAL DESCRIPTION The LN-9 2-Roll and 4-Roll semiautomatic wire feeder models feature the precise "set and forget" digital pro- cedure control. They are designed to achieve higher quality control and weld quality levels more easily . The arc voltage and wire feed speed can be set on a digital meter before the arc is struck and the proce ...

  • Lincoln Electric LN-9 SVM127-A - page 24

    CONTROLS AND SETTINGS Operator controls for LN-9N, NE, S and SE models are shown in Figure B.1. Controls for LN-9F models are shown in Figure B.2. Refer to these figures and the fol- lowing descriptions of the controls. ELECTRODE POLARITY SWITCH: The polarity switch is located inside the wire drive section on the LN-9 model and on the front panel o ...

  • Lincoln Electric LN-9 SVM127-A - page 25

    FIGURE B.1 – WIRE FEEDER CONTROLS FOR LN-9N, NE, S, SE OPERA TION B-5 B-5 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC VOLTS CONTROL METER READING SWITCH DIGITAL METER SET-ACTUAL PUSHBUTTON CIRCUIT BREAKE ...

  • Lincoln Electric LN-9 SVM127-A - page 26

    OPERA TION B-6 B-6 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE B.2 – WIRE FEEDER CONTROLS FOR LN-9F LN-9F CONTROL BOX BOTTOM VIEW ...

  • Lincoln Electric LN-9 SVM127-A - page 27

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-7 B-7 LN-9 Wire Feeder CIRCUIT BREAKER AND GROUNDING LEAD PRO- TECTOR (GLP) RESET SWITCH: These protection circuit devices are located on the front rail of the LN-9 ...

  • Lincoln Electric LN-9 SVM127-A - page 28

    If such a grounding lead fault occurs, the meter will still be on and will be reading. The trigger circuit will not operate, however . T o release the circuit, press the "GLP Reset" button. See Figure B.1 or B.2 for the location of this button. The following precautions are recommended to avoid GLP shutdown: • Do not allow the electrode ...

  • Lincoln Electric LN-9 SVM127-A - page 29

    DRIVE ROLL INST ALLA TION AND PRESSURE SETTING CHANGING WIRE FEED ROLLS AND GUIDE TUBES FOR TWO-ROLL WIRE FEEDERS T o change drive or idle rolls on a two-roll wire feeder , refer to Figure B.3 and perform the following steps: 1. Loosen idle roll spring pressure screw . 2. Remove clamping collar from the drive shaft. 3. Install drive roll and replac ...

  • Lincoln Electric LN-9 SVM127-A - page 30

    6. Loosen the ingoing guide tube clamping screw . Install the all steel guide tube through the rear brass block. T ighten the locking screw . 7. Replace the large ingoing guide tube into rear brass block. 8. Install the outgoing guide tube with its plastic insert through front brass block. T ighten the locking screw so its dog point goes into the g ...

  • Lincoln Electric LN-9 SVM127-A - page 31

    CHANGING WIRE FEED ROLLS AND GUIDE TUBES FOR 4-ROLL WIRE FEED- ERS T o change drive rolls on a 4-roll wire feeder , refer to Figure B.4 and perform the following steps: 1. Release both quick release levers. 2. Remove clamping collars from both drive shafts. 3. Install one drive roll and replace clamping collar . T ighten screw . 4. Slide the middle ...

  • Lincoln Electric LN-9 SVM127-A - page 32

    For Aluminum Wire Each set of rolls should have their pressure set independent of the other . T o do this, release and open the other quick release arm while making each adjustment. Follow the procedure below for each adjustment. 1. With low idle roll pressure, load the feeder so it’s ready for welding. 2. Run the feeder at a slow speed (about 10 ...

  • Lincoln Electric LN-9 SVM127-A - page 33

    OPERA TION B-13 B-13 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE B.4 – INST ALLING DRIVE ROLLS ON A 4-ROLL FEEDER ...

  • Lincoln Electric LN-9 SVM127-A - page 34

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OPERA TION B-14 B-14 LN-9 Wire Feeder WIRE LOADING LOADING AND FEEDING READI-REELS OR SPOOLS LOADING A 22 TO 30 LB. READI-REEL P ACKAGE USING THE MOLDED PLASTIC K363-P TYPE ADAPT ...

  • Lincoln Electric LN-9 SVM127-A - page 35

    7. T o remove the Readi-Reel from the adapter , depress the retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove the adapter from the spindle. LOADING A 15 TO 30 LB. SPOOL (12" DIAMETER): (For 8" spools, a K468 spindle adapter must be used.) 1. Remove the locking collar a ...

  • Lincoln Electric LN-9 SVM127-A - page 36

    LOADING 50 AND 60 LB. COILS AND BRAKE ADJUSTMENT (K299 or K303 Wire Reel Stand) 1. T o remove the wire reel from its shaft, grasp the spring loaded knob and pull it out. This straightens the knob so that it seats into the shaft when released. Remove the reel. 2. Lay the reel flat on the floor , loosen the spinner nut and remove the cover plate. 3. ...

  • Lincoln Electric LN-9 SVM127-A - page 37

    ELECTRODE FEEDING 1. T urn the reel until the free end of the electrode is accessible. 2. While tightly holding the electrode, cut off the bent end. Straighten the first 6 inches. 3. Cut off the first inch. Insert the free end through the incoming guide tube. 4. Insert the free end through the incoming guide tube. 5. Press the gun trigger or “col ...

  • Lincoln Electric LN-9 SVM127-A - page 38

    MAKING A TEST WELD AND ADJUSTING LN-9 RESPONSE AND ST ARTING CHARACTERISTICS ADJUST THE POWER SOURCE DC-250, DC-400, or DC-600* 1. Connect electrode lead to terminal of desired polarity . 2. Set toggle switch to same polarity as the electrode cable connection. 3. Set toggle switch to "Output Control Remote." 4. Set mode switch to the desi ...

  • Lincoln Electric LN-9 SVM127-A - page 39

    ADJUST THE LN-9 CONTROLS 1. Set the "Electrode Polarity" switch to same polarity as the electrode lead. 2. Connect the "Direct Work Lead" if it is going to be used. 3. Check that "Feed Direction" is set to forward. 4. Set the "T rigger Interlock" switch as desired. 5. Set the "Meter Reading" switch ...

  • Lincoln Electric LN-9 SVM127-A - page 40

    MAKING A WELD 1. Inch the electrode through the gun and cable and then cut the electrode within approximately 3/8" of the end of the contact tip for solid wire and within approximately 3/4" of the extension guide for cored wire. 2. Connect the work cable to the metal to be welded. The work cable must make good electrical contact to the wo ...

  • Lincoln Electric LN-9 SVM127-A - page 41

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE OF CONTENTS - ACCESSORIES - Accessories .............................................................................................................................Section C Auxiliary Equipment Contacts ....................................................... ...

  • Lincoln Electric LN-9 SVM127-A - page 42

    AUXILIAR Y EQUIPMENT CONT ACTS The power for 1 15 volt AC auxiliary equipment can be obtained from the terminals inside the LN-9 control box. The contacts are “hot” whenever the trigger is pressed or the unit is welding. The current draw of this circuit must not exceed 1/4 ampere. TURN THE INPUT POWER TO THE POWER SOURCE OFF A T THE DISCONNECT ...

  • Lincoln Electric LN-9 SVM127-A - page 43

    A TT ACHING THE WIRE REEL ST ANDS The mounting hardware for mounting the stands is included with the LN-9. Screws and washers are inserted in their respective mounting holes. T o con- nect: 1. Remove the three 3/8 in. hex head bolts from the back of the wire feed unit. 2. Place the wire reel mounting stand mounting bracket in position against the b ...

  • Lincoln Electric LN-9 SVM127-A - page 44

    ACCESSORIES C-4 C-4 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GUN AND CABLE ASSEMBLIES A variety of standard Lincoln and Magnum gun and cable assemblies are available for the LN-9 in 10 ft., 12 ft. and 1 ...

  • Lincoln Electric LN-9 SVM127-A - page 45

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ACCESSORIES C-5 C-5 LN-9 Wire Feeder WIRE FEEDER ACCESSORIES BURNBACK DELA Y KIT (K202) Provides a precise control of the electrode burnback at the end of the weld. Prevents crat ...

  • Lincoln Electric LN-9 SVM127-A - page 46

    SWIVEL PLA TFORM (K178-1) For all LN-9 wire reel stand combinations. For mount- ing wire feeder-wire reel stand assembly on top of suit- able Lincoln Idealarc power sources. Recommended input cable assembly length is 10 feet (3m) when using the K178-1. Bolt the platform to the lift bail according to instructions supplied with the platform (M16260). ...

  • Lincoln Electric LN-9 SVM127-A - page 47

    ACCESSORIES C-7 C-7 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC MAGNETIC SEP ARA TOR (K58) The K58 is a permanent magnet type separator designed to fit the top of the standard fill funnel of the continuous ...

  • Lincoln Electric LN-9 SVM127-A - page 48

    ACCESSORIES C-8 C-8 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T ABLE C.2 – DRIVE ROLL AND GUIDE TUBE KITS Wire Size Kit 2-Roll 4-Roll Solid Steel Electrode .030 - .035” (0.8 - 0.9 mm) KP502 - 035 KP5 ...

  • Lincoln Electric LN-9 SVM127-A - page 49

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section D-1 Section D-1 LN-9 Wire Feeder T ABLE OF CONTENTS -MAINTENANCE- Maintenance ......................................................................................................................... Section D Routine Maintenance ............................ ...

  • Lincoln Electric LN-9 SVM127-A - page 50

    SAFETY PRECAUTIONS ELECTRIC SHOCK can kill. • Only qualified personnel should perform this maintenance. • T urn the input supply power OFF at the disconnect switch or fuse box before working on this equipment. • Do not touch electrically hot parts. ROUTINE MAINTENANCE DRIVE ROLLS AND GUIDE TUBES After feeding any coil of wire, inspect the dri ...

  • Lincoln Electric LN-9 SVM127-A - page 51

    GUN AND CABLE MAINTENANCE For instructions on periodic maintenance for the weld- ing gun and cables, refer to the manual for your specif- ic model of welding gun. Also see IM-294. GUN CABLE CONNECTOR REQUIREMENTS TO PERMIT PROPER CONNECTION TO LINCOLN LN-9 AND LN-9F WIRE FEEDER The following Figures D.1 and D.2 should serve as a guide to determine ...

  • Lincoln Electric LN-9 SVM127-A - page 52

    MAINTENANCE D-4 D-4 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC FIGURE D.3 – GENERAL COMPONENT LOCA TIONS 1. CONTROL PC BOARD 2. TRIGGER PC BOARD 3. T1 TRANSFORMER 4. POWER PC BOARD 5. BOX ASSEMBL Y 6. D ...

  • Lincoln Electric LN-9 SVM127-A - page 53

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section E-1 Section E-1 LN-9 Wire Feeder Theory of Operation ............................................................................................................. Section E General Description ................................................................. ...

  • Lincoln Electric LN-9 SVM127-A - page 54

    POWER INPUT CIRCUITS The 1 15V AC is applied (usually from the welding power source) via the input connector and through the circuit breaker and R1 resistor to the power board, the T2 trig- ger transformer , and the T1 transformer . The 24V AC developed at the T2 trigger transformer is applied to the trigger board. There it is rectified and regulat ...

  • Lincoln Electric LN-9 SVM127-A - page 55

    TRIGGER AND SHUTDOWN CIRCUIT When the gun trigger switch is activated (closed), the trigger board completes the trigger signal path. This energizes the CR1 relay located on the power board. The CR1 relay activates the wire drive motor and the #2 and #4 circuit, which then activates the Lincoln welding power source. The CR1 relay may also be used to ...

  • Lincoln Electric LN-9 SVM127-A - page 56

    ARC VOL T AGE, WIRE SPEED CONTROL AND METERING The arc voltage, which is sensed at the work piece and motor gear box, is connected through a polarity switch to the voltage board. This actual arc voltage is com- pared to the reference preset voltage that is set by the voltage control. The voltage board determines what correction signal needs to be s ...

  • Lincoln Electric LN-9 SVM127-A - page 57

    PRINTED CIRCUIT BOARD FUNCTIONS POWER BOARD The input power (1 15V AC) is applied to the power board, and from that the power board develops the DC field voltage for the wire drive motor . The SCR circuit- ry , used to control the motor armature voltage, is also contained on the power board. The relay used to activate motor armature voltage, field ...

  • Lincoln Electric LN-9 SVM127-A - page 58

    NOTES E-6 E-6 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric LN-9 SVM127-A - page 59

    Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Section F-1 Section F-1 LN-9 Wire Feeder T roubleshooting & Repair Section ................................................................................ Section F How to Use T roubleshooting Guide .............................................................. ...

  • Lincoln Electric LN-9 SVM127-A - page 60

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC HOW T O USE TROUBLESHOOTING GUIDE Service and repair should be performed by only Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may ...

  • Lincoln Electric LN-9 SVM127-A - page 61

    ELECTRIC SHOCK can kill. Have an electrician install and service this equipment. T urn the machine OFF before working on equipment. Do not touch electrically hot parts. Sometimes machine failures appear to be due to PC board failures. These problems can sometimes be traced to poor electrical connections. T o avoid prob- lems when troubleshooting an ...

  • Lincoln Electric LN-9 SVM127-A - page 62

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-4 F-4 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 63

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-5 F-5 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 64

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-6 F-6 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 65

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-7 F-7 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 66

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-8 F-8 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 67

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-9 F-9 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you do ...

  • Lincoln Electric LN-9 SVM127-A - page 68

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-10 F-10 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. CAUTION If for any reason you d ...

  • Lincoln Electric LN-9 SVM127-A - page 69

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-11 F-11 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you d ...

  • Lincoln Electric LN-9 SVM127-A - page 70

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC F-12 F-12 LN-9 Wire Feeder TROUBLESHOOTING & REP AIR TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. CAUTION If for any reason you d ...

  • Lincoln Electric LN-9 SVM127-A - page 71

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-13 F-13 LN-9 Wire Feeder Observe Safety Guidelines TROUBLESHOOTING GUIDE detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 72

    TROUBLESHOOTING & REP AIR F-14 F-14 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 73

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-15 F-15 LN-9 Wire Feeder TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 74

    TROUBLESHOOTING & REP AIR F-16 F-16 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 75

    TROUBLESHOOTING & REP AIR F-17 F-17 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 76

    TROUBLESHOOTING & REP AIR F-18 F-18 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 77

    TROUBLESHOOTING & REP AIR F-19 F-19 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 78

    TROUBLESHOOTING & REP AIR F-20 F-20 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 79

    TROUBLESHOOTING & REP AIR F-21 F-21 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 80

    TROUBLESHOOTING & REP AIR F-22 F-22 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING GUIDE Observe Safety Guidelines detailed in the beginning of this manual. PROBLEMS (SYMPTOMS) POSSIBLE AR ...

  • Lincoln Electric LN-9 SVM127-A - page 81

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-23 F-23 LN-9 Wire Feeder T1 TRANSFORMER TEST W ARNING Service and repair should be performed by only Lincoln Electric factory trained personnel. U ...

  • Lincoln Electric LN-9 SVM127-A - page 82

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-24 F-24 LN-9 Wire Feeder T1 TRANSFORMER TEST (continued) TEST PROCEDURE 1. Remove input power to the LN-9 wire feed- er . 2. Using the phillips he ...

  • Lincoln Electric LN-9 SVM127-A - page 83

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-25 F-25 LN-9 Wire Feeder 6. Using the volt/ohmmeter , check for 10V AC at secondary leads #601 and #602. T ypically , these leads are yellow . Pla ...

  • Lincoln Electric LN-9 SVM127-A - page 84

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-26 F-26 LN-9 Wire Feeder W ARNING T2 TRANSFORMER TEST Service and repair should be performed by only Lincoln Electric factory trained personnel. U ...

  • Lincoln Electric LN-9 SVM127-A - page 85

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-27 F-27 LN-9 Wire Feeder T2 TRANSFORMER TEST (continued) FIGURE F .3 – “PROTECTION CIRCUIT TROUBLESHOOTING” NAMEPLA TE PROTECTION CIRCUIT TR ...

  • Lincoln Electric LN-9 SVM127-A - page 86

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-28 F-28 LN-9 Wire Feeder T2 TRANSFORMER TEST (continued) 4. Locate the T2 transformer primary lead #32A connected to the 5 amp circuit break- er . ...

  • Lincoln Electric LN-9 SVM127-A - page 87

    TROUBLESHOOTING & REP AIR F-29 F-29 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T2 TRANSFORMER TEST (continued) Electric Shock can kill. • With power applied, there are high voltages inside the wire ...

  • Lincoln Electric LN-9 SVM127-A - page 88

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-30 F-30 LN-9 Wire Feeder W ARNING WIRE DRIVE MOT OR AND T ACH FEEDBACK TEST Service and repair should be performed by only Lincoln Electric factor ...

  • Lincoln Electric LN-9 SVM127-A - page 89

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-31 F-31 LN-9 Wire Feeder WIRE DRIVE MOT OR AND T ACH FEEDBACK TEST (continued) FIGURE F .6 – LEAD #539, #541, #626B AND #627B A T POWER PC BOARD ...

  • Lincoln Electric LN-9 SVM127-A - page 90

    6. Apply 1 15 V AC power . ELECTRIC SHOCK can kill. • With power applied, there are high voltages inside the wire feeder . Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied. 7. With the gun trigger activated or the gun ter- minals jumpered together (see the Wiring Diagram), check the motor arma ...

  • Lincoln Electric LN-9 SVM127-A - page 91

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-33 F-33 LN-9 Wire Feeder T ACH FEEDBACK TEST PROCEDURE 1. Locate tach PC board leads #510, #525 and #555 on the control PC board. See Figure F .7. ...

  • Lincoln Electric LN-9 SVM127-A - page 92

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-34 F-34 LN-9 Wire Feeder W ARNING VOL TMETER ACCURACY TEST Service and repair should be performed by only Lincoln Electric factory trained personn ...

  • Lincoln Electric LN-9 SVM127-A - page 93

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-35 F-35 LN-9 Wire Feeder VOL TMETER ACCURACY TEST (continued) FIGURE F .8 – VOL TMETER CONNECTION POINT TEST PROCEDURE Perform the following che ...

  • Lincoln Electric LN-9 SVM127-A - page 94

    ELECTRIC SHOCK can kill. • With power applied, there are high voltages inside the wire feeder . Do not reach into the wire feeder or touch any internal part of the wire feeder while power is applied. 3. With the LN-9 gun trigger closed or the gun terminals jumpered together (see the Wiring Diagram), the test meter reading should match the LN-9 AC ...

  • Lincoln Electric LN-9 SVM127-A - page 95

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-37 F-37 LN-9 Wire Feeder W ARNING METER CIRCUIT ACCURACY TEST Service and repair should be performed by only Lincoln Electric factory trained pers ...

  • Lincoln Electric LN-9 SVM127-A - page 96

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-38 F-38 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) FIGURE F .9 – METER PC BOARD LOCA TIONS AND COVER MOUNTING SCREWS TEST PROCEDUR ...

  • Lincoln Electric LN-9 SVM127-A - page 97

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-39 F-39 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) 5. T est for AC supply to the meter PC board. Check for 8 to 1 1 V AC from lead # ...

  • Lincoln Electric LN-9 SVM127-A - page 98

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-40 F-40 LN-9 Wire Feeder METER CIRCUIT ACCURACY TEST (continued) T est Digital Meter Accuracy . (For LN-9 models above code 7980 with separable di ...

  • Lincoln Electric LN-9 SVM127-A - page 99

    T est Meter PC Board Accuracy . (Metric Models Only) 1. Use a test meter with at least 3-1/2 digits and +/- .5% accuracy . 2. Connect the + probe to lead called for in the table below and the - probe to lead #510C. NOTE: The coating will have to be removed from the test points. 3. With the meter in SET M/MIN, adjust the speed con- trol until the LN ...

  • Lincoln Electric LN-9 SVM127-A - page 100

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-42 F-42 LN-9 Wire Feeder W ARNING WIRE SPEED ACCURACY TEST Service and repair should be performed by only Lincoln Electric factory trained personn ...

  • Lincoln Electric LN-9 SVM127-A - page 101

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-43 F-43 LN-9 Wire Feeder WIRE SPEED ACCURACY TEST (continued) TEST PROCEDURE Perform the following checks with the LN-9 wire feeder connected to a ...

  • Lincoln Electric LN-9 SVM127-A - page 102

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-44 F-44 LN-9 Wire Feeder W ARNING OUT OF VOL T AGE RANGE SHUT DOWN TEST Service and repair should be performed by only Lincoln Electric factory tr ...

  • Lincoln Electric LN-9 SVM127-A - page 103

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-45 F-45 LN-9 Wire Feeder OUT OF VOL T AGE RANGE SHUT DOWN TEST (continued) FIGURE F .1 1 – VOL T AGE PC BOARD WITH JUMPERS BYPASS PINS 1/8 AMP F ...

  • Lincoln Electric LN-9 SVM127-A - page 104

    TROUBLESHOOTING & REP AIR F-46 F-46 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC OUT OF VOL T AGE RANGE SHUT DOWN TEST (continued) 8. If the ACTUAL voltage reading is zero, the sensing leads may be faul ...

  • Lincoln Electric LN-9 SVM127-A - page 105

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-47 F-47 LN-9 Wire Feeder W ARNING GENERAL POWER SUPPL Y TESTS Service and repair should be performed by only Lincoln Electric factory trained pers ...

  • Lincoln Electric LN-9 SVM127-A - page 106

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-48 F-48 LN-9 Wire Feeder GENERAL POWER SUPPL Y TESTS (continued) TEST PROCEDURE 1. Remove input power to the LN-9 wire feeder . 2. Using the phill ...

  • Lincoln Electric LN-9 SVM127-A - page 107

    TROUBLESHOOTING & REP AIR F-49 F-49 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC GENERAL POWER SUPPL Y CHECKS CHECKPOINT TEST CONNECTOR LEAD NO. NORMAL LOCA TION DESCRIPTION PLUG PIN NO. ACCEPT ABLE VOL ...

  • Lincoln Electric LN-9 SVM127-A - page 108

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-50 F-50 LN-9 Wire Feeder W ARNING DIGIT AL METER AND METER PC BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincol ...

  • Lincoln Electric LN-9 SVM127-A - page 109

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-51 F-51 LN-9 Wire Feeder FIGURE F .12 – METER P ANEL ASSEMBL Y SCREWS MOUNTING SCREWS METER DIGIT AL METER AND METER PC BOARD REMOV AL AND REPLA ...

  • Lincoln Electric LN-9 SVM127-A - page 110

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-52 F-52 LN-9 Wire Feeder FIGURE F .14 – METER PC BOARD REMOV AL 4 MOUNTING NUTS DIGIT AL METER AND METER PC BOARD REMOV AL AND REPLACEMENT (cont ...

  • Lincoln Electric LN-9 SVM127-A - page 111

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-53 F-53 LN-9 Wire Feeder W ARNING REED SWITCH (CR2) REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric facto ...

  • Lincoln Electric LN-9 SVM127-A - page 112

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-54 F-54 LN-9 Wire Feeder PROCEDURE 1. Remove input power to the LN-9 wire feeder . 2. Lift the right side cover assembly . 3. Locate the CR2 reed ...

  • Lincoln Electric LN-9 SVM127-A - page 113

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-55 F-55 LN-9 Wire Feeder W ARNING T1 TRANSFORMER REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory ...

  • Lincoln Electric LN-9 SVM127-A - page 114

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-56 F-56 LN-9 Wire Feeder PROCEDURE 1. Remove input power to the LN-9. 2. Using the phillips head screw driver remove the screws holding the left s ...

  • Lincoln Electric LN-9 SVM127-A - page 115

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-57 F-57 LN-9 Wire Feeder 6. Disconnect leads #526 and #527 from the power PC board terminals. See Figure F .17. T1 TRANSFORMER REMOV AL AND REPLAC ...

  • Lincoln Electric LN-9 SVM127-A - page 116

    Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR F-58 F-58 LN-9 Wire Feeder 8. Remove the two phillips head screws from the control PC board mounting panel. 9. Using the 1 1/32" wrench, remove ...

  • Lincoln Electric LN-9 SVM127-A - page 117

    TROUBLESHOOTING & REP AIR F-59 F-59 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC T1 TRANSFORMER REMOV AL AND REPLACEMENT (continued) 1 1. Using the 5/16" wrench, remove the nuts and lockwashers mou ...

  • Lincoln Electric LN-9 SVM127-A - page 118

    F-60 F-60 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR W ARNING T ACH PC BOARD REMOV AL AND REPLACEMENT Service and repair should be performed by only Lincoln Electric factory ...

  • Lincoln Electric LN-9 SVM127-A - page 119

    TROUBLESHOOTING & REP AIR F-61 F-61 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC PROCEDURE 1. Remove input power to the LN-9 wire feeder . 2. Using the Phillips head screw driver , remove the screws hol ...

  • Lincoln Electric LN-9 SVM127-A - page 120

    F-62 F-62 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR 5. Remove control PC board leads #510, #525 and #555. See Figure F .22. T ACH PC BOARD REMOV AL AND REPLACEMENT (continue ...

  • Lincoln Electric LN-9 SVM127-A - page 121

    F-63 F-63 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR T ACH PC BOARD REMOV AL AND REPLACEMENT (continued) REASSEMBL Y 8. Upon reassembly the spacers must be used to assure tha ...

  • Lincoln Electric LN-9 SVM127-A - page 122

    F-64 F-64 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT W ARNING Service and repair should be performed by only Lincoln Electric factory tr ...

  • Lincoln Electric LN-9 SVM127-A - page 123

    F-65 F-65 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) PROCEDURE 1. Remove input power to the LN-9 wire feeder . 2. Using the ...

  • Lincoln Electric LN-9 SVM127-A - page 124

    F-66 F-66 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) 1 1. Remove the three screws that hold the glas- tic mounting to the LN ...

  • Lincoln Electric LN-9 SVM127-A - page 125

    TROUBLESHOOTING & REP AIR F-67 F-67 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC 13. Lift the right side cover assembly and care- fully lift and slide the motor and wire drive assembly partially out of ...

  • Lincoln Electric LN-9 SVM127-A - page 126

    F-68 F-68 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC TROUBLESHOOTING & REP AIR DRIVE MOT OR REMOV AL AND REPLACEMENT (continued) 15. With the slot head screw driver , remove the three screws, lock was ...

  • Lincoln Electric LN-9 SVM127-A - page 127

    TROUBLESHOOTING & REP AIR F-69 F-69 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC RETEST AFTER REP AIR Retest the LN-9 wire feeder: If it fails any test and the test requires removing or replacing any me ...

  • Lincoln Electric LN-9 SVM127-A - page 128

    NOTES F-70 F-70 LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric LN-9 SVM127-A - page 129

    ELECTRICAL DIAGRAMS G-1 G-1 LN-9 Wire Feeder Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC Electrical Diagram Section ............................................................................................ Section G Wiring Diagram ............................................................................ ...

  • Lincoln Electric LN-9 SVM127-A - page 130

    NOTES LN-9 Wire Feeder Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC ...

  • Lincoln Electric LN-9 SVM127-A - page 131

    G-2 ELECTRICAL DIAGRAMS LN-9 Wiring Diagram 517 510 518 562 518 C2 516 1 2 3 4 5 6 7 8 9 10 11 12 513 C3 VOLTS-SPEED SELECTOR SWITCH 561 560 517 1 4 3 6 2 5 7 8 9 562 561 560 517 510 518 510C 602 601 METER BOARD DIGITAL METER METER BOARD PLUG 562 561 560 517 517 510 518 518 87 6 53 4 1 2 9 510B 510A 602 601 N.O. N.C. N.C. N.O. 515 514 512 511 515 5 ...

  • Lincoln Electric LN-9 SVM127-A - page 132

    G-3 ELECTRICAL DIAGRAMS LN-9 OPERA TING SCHEMA TIC 1702 3-25-94A 8-2-96B OPERATING SCHEMATIC FI NONE 1702 6-14-85 11-1-96 G1590 t UNLESS OTHERWISE SPECIFIED TOLERANCE ON HOLE SIZES PER E2056 ON 2 PLACE DECIMALS IS .02 WITH PUBLISHED STANDARDS. ON 3 PLACE DECIMALS IS .002 ON ALL ANGLES IS .5 OF A DEGREE MATERIAL TOLERANCE (" ") TO AGREE TH ...

  • Lincoln Electric LN-9 SVM127-A - page 133

    G-4 ELECTRICAL DIAGRAMS LN-9 METER BOARD (L6687) SCHEMA TIC (UNLESS OTHERWISE SPECIFIED) EC +5V 602 TP5 METER BOARD SCHEMATIC 21145 LN-9 & LN-9F (METRIC) SUBJECT S SHT. SUP'S'D'G. COMMON CONNECTION EQUIP. TYPE NO. EARTH GROUND CONNECTION POWER SUPPLY SOURCE POINT FRAME CONNECTION CHK. 9-24-93 CLEVELAND, OHIO U.S.A. VOLTAGE NET SU ...

  • Lincoln Electric LN-9 SVM127-A - page 134

    G-5 ELECTRICAL DIAGRAMS LN-9 TRIGGER BOARD (M13861) SCHEMA TIC 1A 600V D5 1A 600V D6 OCI1 4 3 OCI1 1 2 562 R5 1A 600V D2 1A 600V D3 332 R1 1A 600V D4 1A 600V D1 50 25V C1 1W 20V DZ1 1W 75V DZ2 332 R3 562 R4 562 R6 562 R2 500 S 530 622 20031 24 VAC SWITCH 621 TRIGGER 620 623 FILE: S20031_3EB LABELS ELECTRICAL SYMBOLS PER E1537 A PRINTED N.A. SINCE C ...

  • Lincoln Electric LN-9 SVM127-A - page 135

    G-6 ELECTRICAL DIAGRAMS LN-9 T ACHOMETER SCHEMA TIC 525 15.0K R2 1.3K R4 40V 600mA Q1 OCI1 2 3 1 4 1/4W ( UNLESS OTHERWISE SPECIFIED) 1A, 400V RESISTORS = Ohms ( LN-9 TACHOMETER LABELS FRAME CONNECTION SUPPLY POWER SUPPLY SOURCE POINT EQUIP. TYPE THE LINCOLN ELECTRIC CO. S UNLESS OTHERWISE SPECIFIED) NONE 19852 MW 3/8/91 SCHEMATIC 19852 THE INTERCH ...

Fabricant Lincoln Electric Catégorie Welder

Les documents que nous recevons du fabricant de l'appareilLincoln Electric LN-9 SVM127-A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lincoln Electric
- manuels d’utilisations LN-9 SVM127-A
- fiches produit Lincoln Electric
- dépliants
- ou étiquettes-énergie Lincoln Electric LN-9 SVM127-A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lincoln Electric LN-9 SVM127-A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lincoln Electric LN-9 SVM127-A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lincoln Electric LN-9 SVM127-A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lincoln Electric LN-9 SVM127-A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Lincoln Electric LN-9 SVM127-A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lincoln Electric LN-9 SVM127-A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lincoln Electric LN-9 SVM127-A.

Le manuel d’utilisation complet Lincoln Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lincoln Electric LN-9 SVM127-A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lincoln Electric LN-9 SVM127-A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLincoln Electric LN-9 SVM127-A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lincoln Electric LN-9 SVM127-A - qui devraient nous aider dans les premières étapes lors de l'utilisation Lincoln Electric LN-9 SVM127-A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lincoln Electric LN-9 SVM127-A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lincoln Electric LN-9 SVM127-A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lincoln Electric LN-9 SVM127-A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lincoln Electric LN-9 SVM127-A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lincoln Electric LN-9 SVM127-A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)