Manuel d’utilisation Vanguard Heating VDDVF36PN/PP

32 pages 0.95 mb
Télécharger

Aller à la page of 32

Summary
  • Vanguard Heating VDDVF36PN/PP - page 1

    Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL DIRECT -VENT GAS FIREPLACE ® ® VDDVF36PN/PP (PENINSULA) AND VDDVF36STN/STP (SEE THRU) This appliance may be installed in an aftermarket* permanently located, manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use ...

  • Vanguard Heating VDDVF36PN/PP - page 2

    2 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® FRONT VIEW 30 (76cm) (Opening) 23 5 / 8 (60cm) 25 (64cm) RIGHT SIDE 22 5 / 8 (57cm) 43 1 / 8 (110cm) 32 (81cm) (Opening) 1 7 / 8 (5cm) 1 1 / 4 (3cm) BA CK VIEW 39 3 / 4 (101cm) 26 3 / 8 (67cm) 3 (8cm) 1 (3cm) 2 (5cm) 3 (8cm) 22 5 / 8 (57cm) 34 3 / 4 (88cm) T OP VIEW (Left ...

  • Vanguard Heating VDDVF36PN/PP - page 3

    3 106918 OWNER’S MANUAL Models VDDVF36PN/PP series are three-sided direct-vent gas fireplace with a sealed combus- tion chamber. Models VDDVF36STN/STP series are two-sided direct-vent gas fireplace with a sealed combustion chamber. All models use a millivolt gas control and a millivolt igni- tion system. All models have a manual HI/LO valve to co ...

  • Vanguard Heating VDDVF36PN/PP - page 4

    4 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® FRAMING Once the final location has been determined, observing height clearances for vent termi- nation, you may construct framing using dimensions shown in Figures 7 through 9, page 5, depending on your installation. If the appliance is to be installed directly on carpet ...

  • Vanguard Heating VDDVF36PN/PP - page 5

    5 106918 OWNER’S MANUAL Figure 7 - Rough Opening for Installing Peninsula Fireplace 39 3 / 4 " (1010mm) Min. 40 1 / 2 " (1029mm) 23 5 / 8 " (600mm) 39 3 / 4 " (1010mm) Min. 40 1 / 2 " (1029mm) 23 5 / 8 " (600mm) * Figure 8 - Rough Opening for Installing Peninsula Fireplace on Platform * As required by design as long ...

  • Vanguard Heating VDDVF36PN/PP - page 6

    6 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 ...

  • Vanguard Heating VDDVF36PN/PP - page 7

    7 106918 OWNER’S MANUAL WARNING: Read all instruc- tions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. Operation of im- properly installed and maintained venting system could result in serious injury, property damage or loss of life. WARNING: Seal all of ...

  • Vanguard Heating VDDVF36PN/PP - page 8

    8 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed. Snork ...

  • Vanguard Heating VDDVF36PN/PP - page 9

    9 106918 OWNER’S MANUAL UP UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1/2" (190mm) V ent Opening Combustible W all V ent Opening Non-Combustible W all Figure 17 - Vent Opening Requirements Continued 3. Attach vent pipe assembly to the fire- place. Set fireplace in front of it’ s per - manent lo ...

  • Vanguard Heating VDDVF36PN/PP - page 10

    10 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® VENTING INST ALLA TION Continued UP Figure 21 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Figure 22 - Horizontal Termination Using Flexible Venting Horizontal V enting V ertical (V) Horizontal (H) 49.5" min. 15" max. (45 ° el ...

  • Vanguard Heating VDDVF36PN/PP - page 11

    11 106918 OWNER’S MANUAL VENTING INST ALLA TION Continued V enting with T wo 90 ° Elbows V ertical (V) Horizontal (H 1 ) + Horizontal (H 2 ) 5' min. 4' max. 6' min. 8' max. 7' min. 10' max. 8' min. 15' max. 20' max. 20' max. Figure 23 - Horizontal Termination Configuration for Rigid Venting Using ...

  • Vanguard Heating VDDVF36PN/PP - page 12

    12 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® 4. Connect a section of pipe and extend up through the hole. Note: If an offset is needed to avoid obstructions, you must support the vent pipe every 3 feet. Use wall straps for this purpose (see Figure 24). Whenever possible, use 45 ° elbows instead of 90 ° elbows. Th ...

  • Vanguard Heating VDDVF36PN/PP - page 13

    13 106918 OWNER’S MANUAL VENTING INST ALLA TION Continued Continued Figure 26 - Cathedral Ceiling Support Box Installation Non-hardening Mastic under all edges of support box before nailing Figure 27 - Installed Cathedral Ceiling Support Box Vertical Termination Configurations Figures 28 through 31 show four different configurations for vertical ...

  • Vanguard Heating VDDVF36PN/PP - page 14

    14 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® V er tical V enting V = 30' max. Figure 31 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V enting with T wo 9 0 ° Elbo ws V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' m ...

  • Vanguard Heating VDDVF36PN/PP - page 15

    15 106918 OWNER’S MANUAL VENTING INST ALLA TION Continued HIGH ALTITUDE INSTALLATION Your Vanguard direct-vent fireplace has been AGA tested and approved for eleva- tions from 0-2000 feet and CGA certified for elevations from 0-4500 feet. When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the inp ...

  • Vanguard Heating VDDVF36PN/PP - page 16

    16 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® Figure 33 - Wall Switch Wiring Diagram OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL (GHRC SERIES) INSTALLATION Note: If using an optional wireless hand- held remote control, the wall switch is no longer operational. Figure 35 - Installing Remote Receiver (Shown from Rear ...

  • Vanguard Heating VDDVF36PN/PP - page 17

    17 106918 OWNER’S MANUAL INST ALLA TION Continued Installing 9-Volt Alkaline Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of re- mote control unit. 2. Attach terminal wires to the battery (not included). Place battery into the battery housing. 3. Replace battery cover onto remote con- trol unit. Figure 37 - Installing ...

  • Vanguard Heating VDDVF36PN/PP - page 18

    18 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® INST ALLA TION Continued INSTALLING LOG SET Before proceeding, make sure the gas con- trol valve is in the “OFF” position. Logs have been packaged separately to prevent damage to glass or refractory. 1. Remove top and bottom louvers by si- multaneously pulling both t ...

  • Vanguard Heating VDDVF36PN/PP - page 19

    19 106918 OWNER’S MANUAL INST ALLA TION Continued WARNING: Improper installa- tion, adjustment, alteration, ser- vice, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer, service agency, or gas supplier. BURNER REMOVAL CAUTION: Before proceed- ing, make ...

  • Vanguard Heating VDDVF36PN/PP - page 20

    20 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® OPERA TING GUIDELINES AND MAINTENANCE INSTRUCTIONS When lit for the first time, the appliance may emit a slight odor for about 16 - 24 hours. This is normal and is due to the “curing” of the logs and the “burn-in” of internal paints and lubricants used in the man ...

  • Vanguard Heating VDDVF36PN/PP - page 21

    21 106918 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the ap- pliance if service is to be perf ormed. 3. Remove contr ol access panel. 4. Push in gas control knob slightly and turn clockwise to “OFF”. Do not f orce. 5. Replace control access panel. OPERA TING FIREPLACE FOR YOUR ...

  • Vanguard Heating VDDVF36PN/PP - page 22

    22 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® 1. After lighting, let pilot flame burn f or about one minute. T urn contr ol knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMO TE position. Note: The bur n- ers may light if hand-held remote ON button w ...

  • Vanguard Heating VDDVF36PN/PP - page 23

    23 106918 OWNER’S MANUAL Thermocouple Incoming Main Gas Supply Piezo Ignitor Control V alve V ariable Speed Control * Remote Control Electrical Rating: 120v , 60Hz, 0.7A Blower * Use Extension Cord (Included With Kit) Pilot TH TP TPTH Thermopile Piezo Ignitor Do Not Connect T o 120V N.O .SW (W all Switch Supplied) Pilot Gas Line Wirew ay GND BLK ...

  • Vanguard Heating VDDVF36PN/PP - page 24

    24 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® TROUBLESHOOTING OBSERVED PROBLEM Pilot will not light No gas to burner, although wall switch and valve are set to the ON position Frequent pilot outage Burner goes off after a short time POSSIBLE CAUSE 1. No gas supply , or shut-off valve is OFF 2. Air in gas line 3. Con ...

  • Vanguard Heating VDDVF36PN/PP - page 25

    25 106918 OWNER’S MANUAL www.desatech.com TROUBLESHOOTING Continued POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor cable pinched or wet 3. Piezo ignitor nut is loose 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1. Gas supply turned off or manual shu ...

  • Vanguard Heating VDDVF36PN/PP - page 26

    26 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Fireplace produces a whistling noise when burner is lit Glass soots Fireplace produces a clicking/ticking n ...

  • Vanguard Heating VDDVF36PN/PP - page 27

    27 106918 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot re ...

  • Vanguard Heating VDDVF36PN/PP - page 28

    28 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® ACCESSORIES RECEIVER AND HAND-HELD ON/OFF REMOTE CONTROL KIT - GHRC For all models. Allows the gas log heater to be turned on and off by using a hand-held remote control. LOG SET - 105891-01 (27237) Log Piece A - 105896-01 (27238) Log Piece B - 105895-01 (27239) Log Piec ...

  • Vanguard Heating VDDVF36PN/PP - page 29

    29 106918 OWNER’S MANUAL GAS CONTROL VALVE Natural - 104496-01 (14389) Propane/LP - 104496-02 (14390) If in need of replacing, have a qualified technician replace it. END GLASS ASSEMBLY (Peninsula Only) 106922-01 (26624) (Tempered) REFRACTORY PIECES Front (Bottom) 105886-01 (25854) Left/Right (Bottom) 105887-01 (25856) Rear - 106924-01 (27374) Fr ...

  • Vanguard Heating VDDVF36PN/PP - page 30

    30 106918 DIRECT -VENT GAS FIREPLACE VDDVF36PN/PP and VDDVF36STN/STP Series ® NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _________________________________________________________________________ ...

  • Vanguard Heating VDDVF36PN/PP - page 31

    31 106918 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________ ...

  • Vanguard Heating VDDVF36PN/PP - page 32

    LIMITED WARRANTY DIRECT-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this warranty the ...

Fabricant Vanguard Heating Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilVanguard Heating VDDVF36PN/PP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vanguard Heating
- manuels d’utilisations VDDVF36PN/PP
- fiches produit Vanguard Heating
- dépliants
- ou étiquettes-énergie Vanguard Heating VDDVF36PN/PP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vanguard Heating VDDVF36PN/PP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vanguard Heating VDDVF36PN/PP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vanguard Heating VDDVF36PN/PP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vanguard Heating VDDVF36PN/PP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vanguard Heating VDDVF36PN/PP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vanguard Heating VDDVF36PN/PP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vanguard Heating VDDVF36PN/PP.

Le manuel d’utilisation complet Vanguard Heating, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vanguard Heating VDDVF36PN/PP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vanguard Heating VDDVF36PN/PP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVanguard Heating VDDVF36PN/PP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vanguard Heating VDDVF36PN/PP - qui devraient nous aider dans les premières étapes lors de l'utilisation Vanguard Heating VDDVF36PN/PP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vanguard Heating VDDVF36PN/PP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vanguard Heating VDDVF36PN/PP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vanguard Heating VDDVF36PN/PP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vanguard Heating VDDVF36PN/PP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vanguard Heating VDDVF36PN/PP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image