Manuel d’utilisation Foster 7055 062

37 pages Non applicable
Télécharger

Aller à la page of 37

Summary
  • Foster 7055 062 - page 1

    Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com USER'S MANUAL FOR GAS COOKER HOBS Ab stra c t cod. 9606801 ...

  • Foster 7055 062 - page 2

    20 ENGLISH T able of Contents 1. Usage warnings ................................................................................................................... 21 2. Safety warnings .................................................................................................................... 22 3. Warnings for disposal ................... ...

  • Foster 7055 062 - page 3

    21 ENGLISH GENERAL WARNINGS 1. Usage warnings This manual is and integral part of this appliance. It is necessary to keep it undamaged and on hand for the entire life cycle of the hob. We recommend carefully reading this document and all instructions contained within before using the appliance . Installation must be completed by qualified personne ...

  • Foster 7055 062 - page 4

    22 ENGLISH GENERAL WARNINGS 2. Safety warnings In your interest and for your safety , by law it has been established that instal - lation and service for all electric or gas appliances must be carried out by qualified personnel, according to current regulations and the require - ments of local companies supplying gas and electric power . • Ga ...

  • Foster 7055 062 - page 5

    23 ENGLISH GENERAL WARNINGS disposed of correctly . Contact your reseller or competent organizations in your area for information about waste collection centres, recycling and disposal. DO NOT ABBANDON THE P ACKAGING MA TERIAL OR PAR TS OF IT . THEY MA Y CREA TE A SUFFOCA TION DANGER FOR CHILDREN, ESPECIALL Y PLASTIC BAGS. Even your old appliance m ...

  • Foster 7055 062 - page 6

    24 ENGLISH INST ALLER INSTRUCTIONS ENGLISH 5. First installation Do not leave packaging material waste unguarded in the household environment. Separate the various packaging waste materials and deliver them to the closest selective waste collection centres. In order to remove all manufacturing residues, we recommend cleaning the appliance. For furt ...

  • Foster 7055 062 - page 7

    25 ENGLISH INST ALLER INSTRUCTIONS • The distance of the cooker hob from the back edge must be at least 50mm; • The distance of the cooker hob from the walls that exceed worktop height must be at least 100 mm; • Should a hood be installed above the hob, see the hood assembly instructions which provide the correct distance to be re ...

  • Foster 7055 062 - page 8

    26 ENGLISH INST ALLER INSTRUCTIONS • Accurately clean milling. • Before positioning the top, lay the sealer gasket provided on the entire milling surface [ Fig. 5 ]. • Once these operations have been completed, use the supplied brackets to fasten the hob to the structure. Re- fer to the “ Fastening the cooker hob to the cabinet ” ...

  • Foster 7055 062 - page 9

    27 ENGLISH INST ALLER INSTRUCTIONS 7.1 Fixed hooks They make it possible to fasten the cooker hob using fixing frames pre-set along specific points. Standard edge (8 mm) Q4 edge (4 mm) Semi-flush edge (3 mm) Flush-mount edge ...

  • Foster 7055 062 - page 10

    28 ENGLISH INST ALLER INSTRUCTIONS Set hook B in frame A welded to the hob, making sure that it is blocked in the spe - cific holes based on top thickness (for a 30 mm thick top, lock the hook in the the highest hole in the frame; for a 40 mm thick top, block the hook in the lowest hole of the frame). Rotate tongue CA until it is positioned above ...

  • Foster 7055 062 - page 11

    29 ENGLISH INST ALLER INSTRUCTIONS 7.3 Fixed brackets Make it possible to fasten the cooker hob in pre-set fastening points. Standard edge (8 mm) A B Introduce the bracket B in appropriate top seat. Manually lock the bracket using screw A. 8. Connecting the cooker hob to the gas network It is necessary for the gas supply system to conform to local ...

  • Foster 7055 062 - page 12

    30 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : Always place the gasket between the hob fitting and the connection pipe. • If using a stainless steel flexible pipe , it must be installed so that it does not come in contact with any part of the cabinet, but passes through an unoccupied area where its entire length can be inspected. Maximum ex ...

  • Foster 7055 062 - page 13

    31 ENGLISH INST ALLER INSTRUCTIONS 10. Discharging combustion products (exhaust) Discharge of combustion products must be ensured through hoods connected to an efficient natural draught flue, or through a forced exhaust. An efficient exhaust system requires an accurate design by a specialist that is ap - proved for this work, following positions ...

  • Foster 7055 062 - page 14

    32 ENGLISH INST ALLER INSTRUCTIONS Gas type Burner Nominal power (KW) Rated con- sumption (g/h) Injector (ø mm) Min. nominal power (KW) Series No. Ref. METHANE GAS G20 20 mbar II 2 Auxiliary 1,00 95 0,72 0,52 3 Semi-quick 1,75 167 0,97 0,52 4 Quick 2,70 257 1,08 0,90 5 T riple crown 3,50 333 1,35 1,80 10 Dual 4,50 429 i 0.72 / and 1.02 i 0.46 / an ...

  • Foster 7055 062 - page 15

    33 ENGLISH INST ALLER INSTRUCTIONS IMPORT ANT : After adjusting for use with a gas that is different from the initial testing one, replace the label on appliance housing with the one that corresponds to the new gas type. 12. Adjustment of the minimum Instructions for urban and methane gas 1. Light the burner and bring it to the minimum position. 2. ...

  • Foster 7055 062 - page 16

    34 ENGLISH USER INSTRUCTIONS It is mandatory to have an earth connection as per modes foreseen in the electrical system safety standards. • For direct connection to the electric mains, a device must be applied which guar - antees disconnection from the mains with a contact opening distance which al - lows complete disconnection in overvoltage ...

  • Foster 7055 062 - page 17

    35 ENGLISH USER INSTRUCTIONS The upper cover (B) of the burners must be placed in opposite seat with the two intro - ductions notches in correspondence of the two cylinders below (C) and tighten clock - wise. The associated burner is indicated near each knob. The appliance is equipped with an electric ignition device. It is sufficient to press the ...

  • Foster 7055 062 - page 18

    36 ENGLISH USER INSTRUCTIONS 14.2 Practical recommendations for burner use For better burner yield, and minimum gas consumption, it is necessary to use flat and regular bottom pots, equipped with a cover and proportioned to the burner , in order to avoid that the flame goes up their sides (see the “Pots diameter” paragraph [ Page 36 ]). When ...

  • Foster 7055 062 - page 19

    37 ENGLISH USER INSTRUCTIONS 15. Cleaning and maintenance Do not use a steam jet to clean the appliance. Before any intervention it is necessar y to disengage the appliance power supply . Avoid leaving acid or alkaline (vinegar , lemon juice, salt, tomato juice,...) substances on the steel, grids and other parts of the appliance. 15.1 Cleaning the ...

  • Foster 7055 062 - page 20

    182 Riepilogo piani cottura a gas Legenda Serie N. Bruciatore Potenza (W) 1 Manopola di comando II 2 Ausiliario 1.000 3 Semirapido 1.750 4 Rapido 2.700 5 T ripla corona 3.500 10 Dual 4.500 III 6 Ausiliario 1.100 7 Semirapido 1.750 8 Rapido 3.000 9 T ripla corona 3.800 AE 11 Ausiliario 1.100 12 Semirapido 1.750 13 Rapido 3.000 14 Doppia corona 5.000 ...

  • Foster 7055 062 - page 21

    187 1.1 4000 1 6 7 7 8 9 9 N7272V A = 1160 mm B = 480 mm N7272V 1200 1221 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 +1 0 1 6 7 7 8 9 N7252V A = 860 mm B = 480 mm N7252V 900 921 +1 0 500 521 R10.5 10.5 1.5 +1 0 +1 0 +1 0 1 7 7 6 8 9 N7270V A = 860 mm B = 480 mm N7270V 900 921 +1 0 500 521 R10.5 10.5 1.5 +1 0 +1 0 +1 0 ...

  • Foster 7055 062 - page 22

    188 1 8 6 7 7 8 7 N7253V A = 830 mm B = 480 mm N7253V 830 851 +1 0 500 521 +1 0 R10.5 10.5 1.5 +1 0 +1 0 6 7 7 8 1 N7251V A = 560mm B = 480 mm N7251V 600 +1 0 621 +1 0 500 +1 0 521 +1 0 R10.5 10.5 1.5 1 6 9 7 8 N7254V A = 1159 mm B = 348 mm N7254V 1180 +1 0 369 +1 0 1162 351 9 1.5 R10.5 +1 0 +1 0 N7254V A = 1162 B = 351 mm ...

  • Foster 7055 062 - page 23

    189 1 14 N7278V-AEO A = 430 mm B = 480 mm 1 10 N7277V A = 430 mm B = 480 mm 1 12 11 N7276V-AEO A = 360 mm B = 480 mm ...

  • Foster 7055 062 - page 24

    190 1.2 QUADRA 1 2 5 3 4 N7215V A = 1162 mm B = 351 mm N7214V 1180 +1 0 369 +1 0 1162 351 +1 0 9 1.5 R10.5 +1 0 1 2 5 3 N7211V A = 862 mm B = 351 mm N7211V 369 +1 0 351 +1 0 R10.5 9 1.5 926 +1 0 908 +1 0 1 3 N7221V A = 309 mm B = 454 mm N7221V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.5 ...

  • Foster 7055 062 - page 25

    191 1 5 N7223V A = 309 mm B = 454 mm N7223V 309 +1 0 323 +1 0 R11 468 +1 0 454 +1 0 7 1.5 1 1 2 5 2 4 3 N7238V 351 +1 0 955.5 +1 0 157.8 +1 0 45° 955.5 +1 0 351 +1 0 N7238V 369 351 R10.5 955.5 +1 0 973.5 157.8 9 9 9 9 R9.5 R10.5 45° 9 1.5 +1 0 +1 0 +1 0 +1 0 ...

  • Foster 7055 062 - page 26

    192 1.3 KE 1 6 6 7 7 9 N7603VKE A = 840 mm B = 480 mm N7600VKE 7 1.5 500 +1 0 514 +1 0 790 +1 0 804 +1 0 R10.5 N7600VKE N7600VKE A = 770 mm B = 480 mm 1.4 KS 1 6 7 7 7 9 N7610V A = 770 mm B = 480 mm 1 1 6 8 7 7 N7615V A = 560 mm B = 480 mm ...

  • Foster 7055 062 - page 27

    193 1.5 PROFESSIONALE 1 2 3 3 4 5 N7055V-10 N7055V-10 A = 840 mm B = 480 mm N7055V-10 7 1.5 500 514 R10.5 860 874 +1 0 +1 0 +1 0 +1 0 1 2 3 5 N7053V-10 A = 560 mm B = 480 mm N7053V-10 500 514 R10.5 590 604 +1 0 7 1.5 +1 0 +1 0 +1 0 1 2 3 N7062V-08 A = 270 mm B = 480 mm ...

  • Foster 7055 062 - page 28

    194 1 5 N7061V-08 A = 270 mm B = 480 mm 1.6 LISA 1 5 8 7 7 6 N7290V 828.8 587 506.8 R93.5 200.5 303 R161 R1262.5 N7290V 828.8 842.8 +1 0 587 +1 0 601 +1 0 506.8 7 1.5 R100.5 R93.5 200.5 303 R161 R168 R1269.5 R1262.5 +1 0 ...

  • Foster 7055 062 - page 29

    195 1.7 F AUST 1 2 3 3 3 5 N7075V N7048V A = 770 mm B = 480 mm N7047VFT1 7 1.5 500 514 +1 0 790 804 R10.5 +1 0 +1 0 +1 0 1.8 ELEONORA 1 2 3 3 3 5 N7095V A = 770 mm B = 480 mm N7295V 770 480 R135 N7296VFT R152 R145 7 1.5 500 514 860 874 +1 0 +1 0 +1 0 +1 0 ...

  • Foster 7055 062 - page 30

    196 1.9 VULCANO 1 3 10 10 N7097V A = 950 mm B = 480 mm N7297V R152 R145 7 1.5 500 514 +1 0 970 984 +1 0 +1 0 +1 0 1.10 VERONIKA 1 2 4 5 3 3 N7067V A = 560 mm B = 480 mm 1 4 3 3 2 N7066V A = 560 mm B = 480 mm ...

  • Foster 7055 062 - page 31

    197 1 8 7 6 N7063V A = 420 mm B = 480 mm 1 6 7 7 8 8 N7367V 500 +1 0 514 +1 0 760 774 +1 0 R152 R145 7 1.5 +1 0 1 1 6 8 7 7 N7266V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145 ...

  • Foster 7055 062 - page 32

    198 1.11 ELETTRA - P ANDORA 1 2 4 5 3 3 N7064V A = 560 mm B = 480 mm 1 2 4 5 3 3 N7065V A = 560 mm B = 480 mm 1.12 MAGIC 1 2 3 3 4 N7024V A = 740 mm B = 480 mm N7044V 500 +1 0 514 +1 0 760 +1 0 774 +1 0 R152 R145 7 1.5 ...

  • Foster 7055 062 - page 33

    199 1 4 5 3 N7021V A = 740 mm B = 480 mm 1 2 4 3 3 N7023V A = 560 mm B = 480 mm N7042V 7 1.5 600 +1 0 614 +1 0 500 +1 0 514 +1 0 R152 R145 1.13 ALIEN 1 3 5 4 N7017V A A = 840 mm B = 480 mm ...

  • Foster 7055 062 - page 34

    200 1.14 ANGOLARE 1 2 3 5 3 3 N7038V 619 810 330 480 20x45° 810 191x45° 619 810 +4 0 480 +4 0 +4 0 +4 0 +4 0 1.15 F2000 1 2 3 5 N7053000V A = 560 mm B = 480 mm 1 2 3 3 4 5 N7055000V A = 840 mm B = 480 mm ...

  • Foster 7055 062 - page 35

    201 1.16 RONDÒ - GIOTTO 1 4 2 3 N7052V Ø 500 mm 1 10 N7051VG Ø 500 mm 1.17 ALF A 1 6 7 5 8 7 N7260V N7260V A = 840 mm B = 480 mm N7260V 7 1.5 500 +1 0 514 +1 0 R10.5 860 +1 0 874 +1 0 ...

  • Foster 7055 062 - page 36

    202 1.18 GK 14 12 12 11 1 1 GK4F A = 1030 mm B = 450 mm GK4F 1030 +1 0 1051 +1 0 450 +1 0 471 +1 0 R10.5 10.5 1.5 ...

  • Foster 7055 062 - page 37

    Foster spa via M.S. Ottone, 18/20 42041 Brescello (RE) - Italy tel. +39.0522.687425 - tel. Servizio Assistenza +39.0522.684450 fax +39.0522.686019 - fax Servizio Ricambi +39.0522.962166 e-mail: service@fosterspa.com www .fosterspa.com cod. 9606801 Rev . 01 - 04/2012 ...

Fabricant Foster Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilFoster 7055 062 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Foster
- manuels d’utilisations 7055 062
- fiches produit Foster
- dépliants
- ou étiquettes-énergie Foster 7055 062
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Foster 7055 062.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Foster 7055 062, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Foster 7055 062. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Foster 7055 062.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Foster 7055 062, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Foster 7055 062 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Foster 7055 062.

Le manuel d’utilisation complet Foster, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Foster 7055 062 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Foster 7055 062, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFoster 7055 062 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Foster 7055 062 - qui devraient nous aider dans les premières étapes lors de l'utilisation Foster 7055 062
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Foster 7055 062
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Foster 7055 062 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Foster 7055 062?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Foster 7055 062, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Foster 7055 062 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)