Manuel d’utilisation Ducane 2HP13

18 pages 0.28 mb
Télécharger

Aller à la page of 18

Summary
  • Ducane 2HP13 - page 1

    100402-07 Issue 0733 Page 1 of 18 These instructions must be read and understood completely before attempting installation. Issue 0733 S a f e t y P r e c a u t i o n s ...................................... 2 U n i t L o c a t i o n & I n s t a l l a t i o n ................................ 2 Rooftop Installation & Recommendations ........ ...

  • Ducane 2HP13 - page 2

    100402-07 Issue 0733 Page 2 of 18 Safety Precautions Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and foll ow all warning or cautions attached to the unit. 1. Always wear proper personal protection equipment. 2. Always d ...

  • Ducane 2HP13 - page 3

    100402-07 Issue 0733 Page 3 of 18 Elevate Unit Elevate unit per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit. Use snow stand in areas where prolonged freezing temperatures are encountered. If conditions or local codes require the unit be attached to pad or mounting fram ...

  • Ducane 2HP13 - page 4

    100402-07 Issue 0733 Page 4 of 18 Recommended Liquid & Vapor Tube Diameters (In.) It is important that no tubing be cut or seals broken until you are ready to actually make connections to the evaporator and to the condenser section. DO NOT remove rubber plugs or copper caps from the tube ends until ready to make connections at evaporator and co ...

  • Ducane 2HP13 - page 5

    100402-07 Issue 0733 Page 5 of 18 2. The valves should be kept in the "front seated" (closed) position. This will allow evacuation of the refrigeration lines and the indoor coil, without disturbing the factory charge in the outdoor unit. 3. Follow the vacuum pump manufacturer's instructions. Allow the pump to operate until the system ...

  • Ducane 2HP13 - page 6

    100402-07 Issue 0733 Page 6 of 18 Heat Pump Application with Electric Heat Emergency Heat (heating heat pump) If selector switch on thermostat is set to the em ergency heat position, the heat pump will be locked out of the heating circuit, and all heating will be electric heat ( if applicable). A jumper should be placed between W and E on the therm ...

  • Ducane 2HP13 - page 7

    100402-07 Issue 0733 Page 7 of 18 10. Remove charge if superheat is low and add charge if superheat is high. Units with Indoor TXV Units installed with TXV on indoor side, require charging with the subcooling method. 1. Operate unit a minimum of 10 minutes before checking charge. 2. Measure liquid service valve pre ssure by attaching an accurate ga ...

  • Ducane 2HP13 - page 8

    100402-07 Issue 0733 Page 8 of 18 defrost), the defrost relay is energized and defrost begins. The factory setting is 60 minutes. However, if frost accumulation is easily cleared, the optimum efficiency setting is 90 minutes. Outdoor Unit Defrost Control Board Defrost Control Timing Pins Each timing pin selection provides a different accumulated co ...

  • Ducane 2HP13 - page 9

    100402-07 Issue 0733 Page 9 of 18 H/P SINGLE PHASE WIRING DIAGRAM ...

  • Ducane 2HP13 - page 10

    100402-07 Issue 0733 Page 10 of 18 H/P 3 PHASE WIRING DIAGRAM ...

  • Ducane 2HP13 - page 11

    100402-07 Issue 0733 Page 11 of 18 SUPERHEAT TABLES FOR CHARGING SYSTEMS WITH PISTON COILS Required Superheat for 2HP13 (B,L)18P-1A Heating Mode Pressures 2HP13(B,L)18P-1A Required Superheat for 2HP13 (B,L)24P-1A Heating Mode Pressures 2HP13(B,L)24P-1A INDOOR WET-BULB ( / F) OUTDOOR DRY BULB TEMPERA TURE ( / F) 60 65 70 75 80 85 90 95 100 105 110 1 ...

  • Ducane 2HP13 - page 12

    100402-07 Issue 0733 Page 12 of 18 Required Superheat for 2HP13 (B,L)30P-1A Heating Mode Pressures 2HP13(B,L)30P-1A Required Superheat for 2HP13 (B,L)36P-1A Heating Mode Pressures 2HP13(B,L)36P-1A INDOOR WET-BULB ( / F) OUTDOOR DRY BULB TEMPERA TURE ( / F) 60 65 70 75 80 85 90 95 100 105 110 115 53 6 -- -- -- -- -- -- -- -- -- -- -- 55 9 1 -- -- -- ...

  • Ducane 2HP13 - page 13

    100402-07 Issue 0733 Page 13 of 18 Required Superheat for 2HP13 (B,L)42P-1A Heating Mode Pressures 2HP13(B,L)42P-1A Required Superheat for 2HP13 (B,L)48P-1A Heating Mode Pressures 2HP13(B,L)48P-1A INDOOR WET-BULB ( / F) OUTDOOR DRY BULB TEMPERA TURE ( / F) 60 65 70 75 80 85 90 95 100 105 110 115 53 6 -- -- -- -- -- -- -- -- -- -- -- 55 9 1 -- -- -- ...

  • Ducane 2HP13 - page 14

    100402-07 Issue 0733 Page 14 of 18 Required Superheat for 2HP13 (B,L)60P-1A Heating Mode Pressures 2HP13(B,L)60P-1A ......................... INDOOR WET-BULB ( / F) OUTDOOR DRY BULB TEMPERA TURE ( / F) 60 65 70 75 80 85 90 95 100 105 110 115 53 6 -- -- -- -- -- -- -- -- -- -- -- 55 9 1 -- -- -- -- -- -- -- -- -- -- 57 12 4 -- -- -- -- -- -- -- -- - ...

  • Ducane 2HP13 - page 15

    100402-07 Issue 0733 Page 15 of 18 Homeowner's Information Heat Pump Operation Your new heat pump has several characteristics that you should be aware of: ! Heat pumps satisfy heating demand by delivering large amounts of warm air into the living space. This is quite different from gas-or oil-fired furnaces or an electric furnace which deliver ...

  • Ducane 2HP13 - page 16

    100402-07 Issue 0733 Page 16 of 18 On models without a fan Selection Switch, the fan will cycle with the outdoor unit. Important System Information ! Your system should never be operated without a clean air filter properly installed. ! Return air and supply air registers should be free from restrictions or obstructions to allow full flow of air. Re ...

  • Ducane 2HP13 - page 17

    100402-07 Issue 0733 Page 17 of 18 OUTDOOR EQUIPMENT LIMITED WARRANTY (Not applicable outside the U.S.A. and Canada.) Warrantor: Allied A ir Enterprises Inc., 215 Me tropolitan Driv e, West Columbia, SC 29170 These Allied Air Enterprises, Inc. Products are available under the following names: Ducane, Concord GENER AL FI VE YEAR PART WARRANTY - (her ...

  • Ducane 2HP13 - page 18

    100402-07 Issue 0733 Page 18 of 18 Keep this book and your sales slip together for future refe rence. You must provide proof of purchase or installation date for in-warranty service. Write down the following information about your unit to better help you obtain assistance or service if you ever need it. You will need to know the complete model and ...

Fabricant Ducane Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilDucane 2HP13 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Ducane
- manuels d’utilisations 2HP13
- fiches produit Ducane
- dépliants
- ou étiquettes-énergie Ducane 2HP13
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Ducane 2HP13.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Ducane 2HP13, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Ducane 2HP13. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Ducane 2HP13.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Ducane 2HP13, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Ducane 2HP13 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Ducane 2HP13.

Le manuel d’utilisation complet Ducane, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Ducane 2HP13 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Ducane 2HP13, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDucane 2HP13 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Ducane 2HP13 - qui devraient nous aider dans les premières étapes lors de l'utilisation Ducane 2HP13
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Ducane 2HP13
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Ducane 2HP13 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Ducane 2HP13?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Ducane 2HP13, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Ducane 2HP13 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)