    1 Y our air compressor has been engineer ed and manufactured to our high standar d for dependability , ease of operation, and operator safety . When properly car ed for , it will give you years of rugged, trouble-free performance. WARNING: T o reduce the risk of injury , the user must read and understand the operator’ s manual before using this p ...

  • RIDGID OL50135W - page 2

    2 3 n Introduction ..................................................................................................................................................................... 2 � n General Safety Rules ........................................................................................................................................ ...

  • RIDGID OL50135W - page 3

    2 3 GENERAL SAFETY RULES WARNING: Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fir e, and/or serious personal injury . SA VE THESE INSTRUCTIONS WORK AREA n Keep y our work area clean and well lit. Cluttered benches and dark areas invite accidents. Floor must not be slippery from ...

  • RIDGID OL50135W - page 4

    4 5 n Know your power tool. Read operator’s manual care- fully. Learn its applications and limitations, as well as the specific potential hazards related to this tool. Following this rule will reduce the risk of electric shock, fire, or seri- ous injury. n Drain tank of moisture after each day’s use. If unit will not be used for a while, it is ...

  • RIDGID OL50135W - page 5

    4 5 SYMBOLS Some of the following symbols may be used on this tool. Please study them and learn their meaning. Pr oper interpr eta- tion of these symbols will allow you to operate the tool better and safer . Read The Operator’ s Manual Risk of Bursting Risk of Fire or Explosion SYMBOL NAME DESIGNA TION/EXPLANA TION V oltage Current Frequency (cyc ...

  • RIDGID OL50135W - page 6

    6 7 SYMBOLS SERVICE Servicing requir es extreme car e and knowledge and should be performed only by a qualified service tech- nician. For service we suggest you return the product to the nearest AUTHORIZED SERVICE CENTER for r epair . When servicing, use only identical replacement parts. WARNING: T o avoid serious personal injury , do not attempt t ...

  • RIDGID OL50135W - page 7

    6 7 EXTENSION CORDS Use only 3-wire extension cords that have 3-prong gr ound- ing plugs and 3-pole receptac les that accept the tool’ s plug. When using a power tool at a cons iderab le dis tance from the power source, use an extension cord heavy enough to carry the curr ent that the tool will draw . An undersized extension cord will cause a dro ...

  • RIDGID OL50135W - page 8

    8 9 GLOSSAR Y OF TERMS Pressur e Switch Automatically controls the on/off cycling of the compressor . It stops the compr ess or wh en the cut -of f pres sur e in the tank is r eached and starts the compressor when the air pr essure drops below the cut-in pr essure. Pounds Per Square Inch (PSI) Measurement of the pressur e exerted by the force of th ...

  • RIDGID OL50135W - page 9

    8 9 FEA TURES Fig. 2 PRODUCT SPECIFICA TIONS Air Tank Capacity ....................................................... 5 gal. Air Pressure .................................................... 135 psi max. Air Delivery ........................................... 4.6 SCFM @ 90 psi Gauges .......................................................... 2 in ...

  • RIDGID OL50135W - page 10

    10 11 FEA TURES KNOW YOUR AIR COMPRESSOR See Figure 2. Before attempting to use this pr oduct, familiarize yourself with all operating features and safety rules. BUIL T -IN CORD WRAP A built-in cord wrap is provided for convenience in moving and storing the unit. DRAIN V AL VES A drain valve is located on each tank for draining condensa- tion to he ...

  • RIDGID OL50135W - page 11

    10 11 ASSEMBL Y BREAKING IN THE PUMP See Figures 4 - 5. Perform the following steps to break in the pump before using the air compressor for the first time. n Make sure the plug in the oil fill hole has been replaced with the dipstick and the oil level falls within the MIN and MAX range. n Turn the pressure regulator knob fully clockwise to open th ...

  • RIDGID OL50135W - page 12

    12 13 BUIL T -IN CORD WRAP OPERA TION WARNING: Do not allow familiarity with tools to make you careless. Remember that a careless fraction of a second is sufficient to inflict sever e injury . WARNING: Alwa ys wear safety gog gles or safety glasses with side shields when operating tools. Failure to do so could result in objects being thrown into yo ...

  • RIDGID OL50135W - page 13

    12 13 Fig. 8 REFERENCE LEVEL MARKS OIL FILL HOLE DIPSTICK OIL DIPSTICK OPERA TION CHECKING THE OIL See Figures 8 - 9. The air compressor is pr e-filled with the proper type and quantity of oil. However , it is necessary to check the oil level before each use, and add oil if needed. NOTE: Always check the oil when the unit is sitting on a level surf ...

  • RIDGID OL50135W - page 14

    14 15 OPERA TION Fig. 10 Fig. 11 USING THE AIR COMPRESSOR See Figures 10 - 11. n Ensure power switch is in the OFF (O) position and air compressor is unplugged. n If not already installed, attach hose to compressor as previously instructed. n Attach 1/4 in. NPT male connector fitting to accessory or tool you intend to use. n Insert the other end of ...

  • RIDGID OL50135W - page 15

    14 15 WARNING: If air leaks after the ring has been released, or if the valve is stuck and cannot be actuated by the ring, Do not use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could r esult in serious personal injury . DRAINING THE T ANKS See Figure 12. T o help prevent tank corrosion a ...

  • RIDGID OL50135W - page 16

    16 17 MAINTENANCE WARNING: W h e n s e r v i c i n g u s e o n l y i d e n t i c a l R I D G I D replacement parts. Use of any other parts may create a hazar d or cause product damage. WARNING: Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust. If operation is dusty , also wear a dust ma ...

  • RIDGID OL50135W - page 17

    16 17 MAINTENANCE Fig. 15 Fig. 16 HEX HEAD BOL T DRAIN PLUG OIL FILL HOLE CHANGING THE OIL See Figures 15 - 16. Replace the oil after the first 100 hours of operation and every 300 hours following the first oil change. NOTE: Though not necessary , you may find it helpful to remove the wheel from the unit to easily access the oil drain. T o remove t ...

  • RIDGID OL50135W - page 18

    18 19 TROUBLESHOOTING PROBLEM CAUSE SOLUTION Compressor will not run Loss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Thermal overload open Pressur e switch bad T ank is full of air C h e c k f o r p r o p e r u s e o f e x t e n s i o n cord Ch ec k to b e s ur e u ni t i s p lu g ge d i n Check fuse/b ...

  • RIDGID OL50135W - page 19

    18 19 TROUBLESHOOTING Air r eceiver pr essure drops when com- pressor shuts of f Loose connections (fittings, tubing, etc.) Loose drain valve Check valve leaking Check all connections with soap and water solution and tighten Tighten drain valve T ake compressor to service center DANGER: Do not disassemble check valve, tank drain valves or safe ty r ...

  • RIDGID OL50135W - page 20

    20 21 NOTES ...

  • RIDGID OL50135W - page 21

    20 21 Proof of purchase must be presented when r equesting war - ranty service. This product is manufactured by One W orld T echnologies, Inc. The trad emark is licen sed fr om RIDGID, Inc. All warran ty commun ication s shoul d be dir ecte d to One W orld T ech nolo- gie s, Inc., attn : RIDGID Han d He ld and Statio nary Pow er T ool T echnical Se ...

  • RIDGID OL50135W - page 22

    22 983000-800 7-05 Customer Service Information: For parts or service, contact your nearest RIDGID authorized service center . Be sure to provide all relevant information when you call or visit. For the location of the authorized service center near est you, please call 1-866-539-1710 or visit us online at www .ridgid.com. The model number of this ...

Fabricant RIDGID Catégorie Air Compressor

Les documents que nous recevons du fabricant de l'appareilRIDGID OL50135W peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques RIDGID
- manuels d’utilisations OL50135W
- fiches produit RIDGID
- dépliants
- ou étiquettes-énergie RIDGID OL50135W
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation RIDGID OL50135W.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation RIDGID OL50135W, manuels d’entretien, brefs manuels ou manuels de l’utilisateur RIDGID OL50135W. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit RIDGID OL50135W.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil RIDGID OL50135W, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser RIDGID OL50135W par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs RIDGID OL50135W.

Le manuel d’utilisation complet RIDGID, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel RIDGID OL50135W - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières RIDGID OL50135W, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRIDGID OL50135W qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil RIDGID OL50135W - qui devraient nous aider dans les premières étapes lors de l'utilisation RIDGID OL50135W
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de RIDGID OL50135W
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service RIDGID OL50135W dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de RIDGID OL50135W?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec RIDGID OL50135W, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec RIDGID OL50135W il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)