    Operation Ma nual LAM 3 IR RED / INFRARED LASER AIMER / ILLUMINATOR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...

  • Newcon Optik LAM 3 IR - page 2

    ii LASER RADIATION –AVOID EXPOSURE TO THE BEAM INFRARED LASER OUTPUT POWER <25 mW WAVELENGTH 830-860 nm RED LASER OUTPUT POWER <8 mW WAVELENGTH 630-660 nm CLASS 3B LASER PRODUCT LASER WARNING LABEL IS LOCATED ON TOP OF THE DEVICE ...

  • Newcon Optik LAM 3 IR - page 3

    iii IMPORTANT INFORMATION Read prior to activation You have ju st purchased a sophisticat ed electronic de vice. To operate it properly, please read this manual carefully. LAM belongs t o Class 3b lase r products i n accordance with IEC 6 0825-1. This radiation is hazardous for your eyes. Here are some comm on precautions t hat must be observed. Av ...

  • Newcon Optik LAM 3 IR - page 4

    iv  NEVER reverse polarity of the battery  ALWAYS make sure that the device i s fixed firml y on the weapon  ALWAYS remove battery whe n not in use fo r a long period  ALWAYS store in a warm dry place when not in use  ALWAYS clea n output windows wi th soft c loth only  ALWAYS check t he O-ring when repl acing the battery. ...

  • Newcon Optik LAM 3 IR - page 5

    1 CONTENTS 1. Brief description ..........................................................2 1. LAM DESIGN AND APPEAR ANCE ........................ 3 2. DELIVERY S ET ......................................................... 9 2.1 Standard deliv ery set ................................... 9 3. SPECIFICATION S ........................................ ...

  • Newcon Optik LAM 3 IR - page 6

    2 Carefully read all the instructions prior to use. Failure to obey the instructions will void the warranty ! INVISIBLE LASER RADIAT ION CLASS 3B LASER PRODUCT 830–860 nm 25 mW, 630-650 nm 8 mW. DON’T LOOK INTO THE BEAM! 1. Brief description LAM laser aimer/illuminator (hereinafter referred as LAM) is desi gned for precise aiming at day and nig ...

  • Newcon Optik LAM 3 IR - page 7

    3 1. LAM 3IR APPEARANCE Fig. 1 — Front view 1 - Windage and elevation adjustment knobs, for Visible & IR aimer channel 2 - Windage and elevation adjustment knobs, for illuminator channel 3 – Housing 4 - IR ai mer 5 - Visible red aimer 6 - Battery compart ment cover 7 – Illuminator 8 - Illuminator beam divergence adjustment ring 9 - Quick ...

  • Newcon Optik LAM 3 IR - page 8

    4 Fig. 2 — LAM rear view 11 - Bracket 12 - blocking ri ng 13 - mode s witch 14 - low battery indicator 15 – hig h / low (wor king / t raining m odes) power s witch 16 - remote button conn ector 17 - windage adjustment knob, illuminator channel 11 17 16 15 14 13 12 ...

  • Newcon Optik LAM 3 IR - page 9

    5 LAM consists of three laser emitters – IR aimer (4, Fig. 1), visible aimer (5, Fig.1) and IR illuminator (7, Fig. 1) – comb ined in o ne h ous ing (3 , Fi g. 1 ) w ith i nter axis distance of 44.8 millimeters. LAM is powered by a lithium battery (CR123 type). Th e battery is installed between aimer and illuminator and covered with battery com ...

  • Newcon Optik LAM 3 IR - page 10

    6 OFF LAM is off R Visible aimer is on P IR aimer is on IL Illuminator is on ILP Both IR aimer and Illuminator are on BT Battery test The LED (14, Fig. 2) in BT mode indicates bat tery level: solid red LED means the battery charge is normal, if it is blinking - the batte ry must be replace d. IR channels of LAM can ope rate at high (H m ode) and lo ...

  • Newcon Optik LAM 3 IR - page 11

    7 High power mode is a health hazard! Lock switch (15, Fig.2) with blo cking ring (12, Fig.2) when you do not intend using LAM in high power mode. Use filter with the Red Channel in the training mode LAM can be turned on either w ith a switch (13, Fig. 2) or with a remote control pressure switch, when it is connected through the remote control conn ...

  • Newcon Optik LAM 3 IR - page 12

    8 points (de pending on t he locati on of LAM on t he weapon). For precise shooting you sho uld know the distance to the target and ha ve trajectory correction t able for your weapon. The shooter shou ld estimate the distance and determine the s hift of the aim er spot in acc ordance with the correction table. Use illuminator when light cond itions ...

  • Newcon Optik LAM 3 IR - page 13

    9 2. DELIVERY SET Standard delivery set Quantity Laser aimer / illuminator LAM 3 IR with mount 1 Remote pressure switch 1 O-Ring 1 Soft case 1 Manual 1 Warranty card 1 ...

  • Newcon Optik LAM 3 IR - page 14

    10 3. SPECIFICATIONS Aimer V IR Illuminator Laser wavelength 635 ± 10 nm 830-860 nm 830- 860 nm Beam divergence 0.4 mrad (1’) 0.9-80 mrad (3’...4°30’) Power of laser emission, L mode H mode 0.24 mW  10% with filter 25 mW  10% 2 mW  10% 25 mW  10% 2 mW  10% Windage / elevation adjustment range ± 20 mrad (±1°10’) Adjustmen ...

  • Newcon Optik LAM 3 IR - page 15

    11 4. OPERATION INSTRUCTIONS DANGER! THIS LASER EQUIPMENT IS HAZARDOUS FOR YO UR EYES!  Do not look into laser beam with naked eyes or through any optical device.  Do not point an active unit at highly reflective surfaces or towards other indivi duals or animals. Battery installation  Ensure the m ode switch (13, Fig. 2) is in OF F positio ...

  • Newcon Optik LAM 3 IR - page 16

    12 Mounting LA M on a weapon  Mount LAM on the Picatinny rail u sing the quick release lever mount (9, Fig. 1) so that the laser emission is directed towards the target;  If desired, connect the remote switch cable to the connector (16, Fig. 2) a nd tighten t he nut. Fix t he remote switch on the weapon pivot or gr ip by Velcro tape in place, ...

  • Newcon Optik LAM 3 IR - page 17

    13 1. Mount LAM on the weapo n. 2. Fix the weapon in the aiming rest. 3. Insert the laser bore sight into the barrel. 4. Zero the bore sight in accordance with its operation manual. 5. Set the target at the distance, required for th is weapon and this target. 6. Activate LAM in ILP mode. 7. Set minimal divergence of the illuminato r channel. 8. Set ...

  • Newcon Optik LAM 3 IR - page 18

    14 4. Set the minimal divergence of the illuminator channel. 5. Superpose ce nters of the sp ots produced by the aimer and illuminator on the aiming mark by rotating adjustment knobs (1, Fig. 1), (1 7, Fig. 2). 6. Fire the we apon. 7. If point of impact is off the aiming m ark adjust windage and el evation by r otating adjustm ent knobs (1, Fig. 1) ...

  • Newcon Optik LAM 3 IR - page 19

    15 Preparing LAM for transpo rtation 1. Turn LAM off by turning operating modes switch (13, Fig. 2) to OFF position. 2. Disconnect the remote switch from the weapon. 3. Loosen quick release lever (9, Fi g.1), remove LAM from Picat inny rail. 4. Pack LAM and remote switch into the case ...

  • Newcon Optik LAM 3 IR - page 20

    16 5. CARE, STORAGE AND TRANSPORTA TION General LAM is a sophisticated precise optical in strument equipped with electronics. Ther efore, it should be handled with due care. - Never disassem ble LAM. - Keep away from direct sunlight, im pacts, dust, moisture, and sharp cha nges of temperature. - Do not store LAM at tem peratures higher than 70 o C ...

  • Newcon Optik LAM 3 IR - page 21

    17 If LAM was exposed to salt water it should be rinsed in fresh water a nd dried outside at n o more than 55 o C. Long-term storage When preparing for long-term storage, cover the exte rnal metal surfaces of LAM with pr otective lubricant. Eac h 4 (four) years old layer of lubri cant should be removed a nd new layer be applied. To remove ol d laye ...

  • Newcon Optik LAM 3 IR - page 22

    18 2. When preparin g for a long- term storage LA M just received from manufacture r or from workshop ensure that actual set is the same as indicated in the Delivery Set section of this manual. 3. Cases with units shoul d be placed on stands, shelves or in cupboards in dry heated and v entilated premises in accordance with Stora ge conditions as de ...

  • Newcon Optik LAM 3 IR - page 23

    19 8. Presence of acid and alkaline vapor, as well as of other aggressi ve admixtures i n the air i n the storage area may cause damage to L AM. 9. After 4 years of storage, it is necessary to perform thorough inspection of units’ functionality. Transporta tion When packed, LAMs ca n be transported by any covered means in accordance with Storage ...

  • Newcon Optik LAM 3 IR - page 24

    20 6. TROUBLESHOOTING The LED indicator is off when switch is ON. Turn the switch on again. If LAM still does not go ON check that battery is installe d properly and has sufficient charge. Replace battery if necessary. Spot shape or size has chan ged Emitter objective lens is dirty. Flush emitter lens with fresh water and wipe it with soft cloth. I ...

  • Newcon Optik LAM 3 IR - page 25

    21 7. WARRANTY NEWCON warrants this product against defects in material and workmanship for one year from the date o f the original purchase. Longe r warranty is available, subject to the terms of the specific sales contract. Should your Newcon pr oduct prove to be defecti ve during this period, please deliver the produc t securely packaged in its ...

  • Newcon Optik LAM 3 IR - page 26

    22 Postage, insura nce, and ship ping costs i ncurred whi le presenting your NEWCON p roduct for w arranty service are your responsibility. If shipping from North America please incl ude a cheque or money or der payabl e to NEWCON OPTIK fo r the amount of $15.00 to cover handling a nd retu rn shipping . ...

  • Newcon Optik LAM 3 IR - page 27

    23 8. CUSTOMER SUPPORT Should you experience an y difficulties with your NEWCON OP TIK product , consult t he enclosed m anual. If the problem remains unreso lved, contact our customer support department at ( 416) 663-6963 or toll free at 1- 877-368-6666 . Our oper ating hours ar e 9am-5pm, Monday - Friday, Eastern Standard Time. At no tim e should ...

  • Newcon Optik LAM 3 IR - page 28

    24 10. QUALITY CERTIFICATE LAM 3 IR seri al number_______ ____________ __________ complies wit h all technical specifi cations and has passed the inspection. Date of pr oduction: _____________ ____________ ________ Quality Inspector: _____________ ____________ _________ Quality Assurance Seal ...

  • Newcon Optik LAM 3 IR - page 29

    25 ...

  • Newcon Optik LAM 3 IR - page 30

    26 ...

  • Newcon Optik LAM 3 IR - page 31

    27 ...

  • Newcon Optik LAM 3 IR - page 32

    NEWCON OPTIK  M065-24/A/XII R1.I – 8.11 ...

Fabricant Newcon Optik Catégorie Binoculars

Les documents que nous recevons du fabricant de l'appareilNewcon Optik LAM 3 IR peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Newcon Optik
- manuels d’utilisations LAM 3 IR
- fiches produit Newcon Optik
- dépliants
- ou étiquettes-énergie Newcon Optik LAM 3 IR
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Newcon Optik LAM 3 IR.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Newcon Optik LAM 3 IR, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Newcon Optik LAM 3 IR. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Newcon Optik LAM 3 IR.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Newcon Optik LAM 3 IR, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Newcon Optik LAM 3 IR par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Newcon Optik LAM 3 IR.

Le manuel d’utilisation complet Newcon Optik, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Newcon Optik LAM 3 IR - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Newcon Optik LAM 3 IR, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNewcon Optik LAM 3 IR qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Newcon Optik LAM 3 IR - qui devraient nous aider dans les premières étapes lors de l'utilisation Newcon Optik LAM 3 IR
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Newcon Optik LAM 3 IR
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Newcon Optik LAM 3 IR dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Newcon Optik LAM 3 IR?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Newcon Optik LAM 3 IR, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Newcon Optik LAM 3 IR il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)