    SE95010 Rev . 9 Operators Manual Installation, Operation & Service Gas T able T op Kettles MODELS : KGT -6-T KGT -12-T 1333 East 179th S t., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com Clev elan d ™ Enodis For models built af ter July 2002 ...

  • Cleveland Range KGT-12-T - page 2

    FOR THE USER IMPOR T ANT POST IN A PROMINENT LOCA TION, INSTRUCTIONS T O BE FOLLOWED IN THE EVENT THE USER SMELLS GAS. THIS INFORMA TION SHALL BE OBT AINED BY CONSUL TING YOUR LOCAL GAS SUPPLIER. KEEP APPLIANCE AREA FREE AND CLEAR FROM COMBUSTIBLES. DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR. ALL SERVICE MUST BE PERFORMED BY A QUAL ...

  • Cleveland Range KGT-12-T - page 3

    INSPECTION Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions. SHIPPING DAMAGE INSTRUCTIONS If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim. 1. Write down ...

  • Cleveland Range KGT-12-T - page 4

    Installation must be in accordance with local codes and/or the National Fuel Gas Code ANSI Z223.1 Latest Edition (USA) or the latest Installation Codes for Gas Burning Appliances and Equipment CAN/ CGA B149.1 and CAN/ CGA B149.2 (Canada). Use a gas pipe joint compound which is resistant to L.P . gas. T est all pipe joints for leaks with soap and wa ...

  • Cleveland Range KGT-12-T - page 5

    6 7 8 5 4 3 2 1 9 OPERA TING INSTRUCTIONS ITEM # DESCRIPTION FUNCTION 1. Tilting Handle Used for tilting the kettle. 2. V acuum/Pressur e Gauge Indicate steam pressur e in PSI inside steam jacket as well as vacuum in inches of mercury . 3. Pressur e Relief V alve This valve is used to vent the kettle and in the unlikely event there is an excess ste ...

  • Cleveland Range KGT-12-T - page 6

    OPERA TING THE KETTLE DO NOT A TTEMPT TO OPERA TE THIS APPLIANCE DURING A POWER F AILURE. KEEP APPLIANCE AND AREA FREE AND CLEAR OF COMBUSTIBLES. DO NOT LEAN ON OR PLACE OBJECTS ON KETTLE LIP . SERIOUS INJURY COULD RESUL T IF KETTLE TIPPED OVER, SPILLING HOT CONTENTS. 1. Before turning kettle on, read the V acuum/Pressure Gauge ( 2 ). The gauges ne ...

  • Cleveland Range KGT-12-T - page 7

    MARINE LOCK Y our unit is equipped with a marine lock to prevent accidental tilting. The following procedur e should be used to tilt the kettle. 1. Grasp the tilt handle. 2. Hold the latch down to unlock tilting mechanism. 3. Pull the handle to tilt kettle. 4. T o lock, r etur n the kettle to its upright position and push handle back. NOTE: Inspect ...

  • Cleveland Range KGT-12-T - page 8

    ST AINLESS STEEL EQUIPMENT CARE AND CLEANING (Suppied courtesy of Nafem. For more information visit their web site at www .nafem.org) Contrary to popular belief, stainless steels ARE susceptible to rusting. Corrosion on metals is everywhere. It is r ecognized quickly on iron and steel as unsightly yellow/orange rust. Such metals are called “activ ...

  • Cleveland Range KGT-12-T - page 9

    SER VICE P AR TS W ARRANTY Our Company supports a worldwide network of Maintenance and Repair Centers. Contact your nearest Maintenance and Repair Centre for r eplacement par ts, service, or information regarding the pr oper maintenance and repair of your cooking equipment In order to pr eserve the various agency safety cer tification (UL, NSF , AS ...

  • Cleveland Range KGT-12-T - page 10

    CONSOLE COMPONENTS (used after J une 2005) ITEM # P ART # DESCRIPTION QTY . 1. KE600545 COMPONENT MOUNTING BRACKET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. KE50753-7 RELA Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3. KE00458 SOLID ST A TE CONTROL ...

  • Cleveland Range KGT-12-T - page 11

    CONSOLE COMPONENTS (used prior to June 2005) ITEM # P ART # DESCRIPTION QTY . 1-8 KE01928-3 COMPONENT PLA TE ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. KE01927-2 COMPONENT MOUNTING PLA TE WELDMENT . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE50753-7 RELA Y . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGT-12-T - page 12

    O VERHEAD VIEW 3 2 1 ITEM # P ART # DESCRIPTION QTY . 1. F A21024 HEX NUT , SS, 5/16-18 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. F A31030 HELICAL SPRING LOCK W ASHER, SS, 5/16" DIA. . . . . . . . . . . . . . . . . . . . . . . 4 3. KE600343 BARTITE SEALING WASHER, 5/16" DIA. . . . . . . . ...

  • Cleveland Range KGT-12-T - page 13

    SWITCHES & INDICA TORS (used after J une 2005) KE600560-B 2 3 5 6 7 8 9 1 4 10 OFF 4 1 2 5 6 3 ITEM # P ART # DESCRIPTION QTY . 1. KE55486-3 INDICA TOR LIGHT , GREEN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2. KE55486-2 INDICA TOR LIGHT , RED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGT-12-T - page 14

    SWITCHES & INDICA TORS (used prior to June 2005) 5 6 5 4 2 3 1 8 5 7 ITEM # P ART # DESCRIPTION QTY . 1. SE00114 POTENTIOMETER WITH ON/OFF SWITCH, C/W ITEM #2 . . . . . . . . . . . . . . . . .1 2. KE51005 ROT ARY SEAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50569-1 KNOB, POTENT ...

  • Cleveland Range KGT-12-T - page 15

    1 2 3 5 6 17 1 8 19 SEE FAUCET DRAWING 20 21 2 8 25 26 27 2 8 4 22 2 3 24 7 8 ITEM # P ART # DESCRIPTION QTY . 1. SK50403 BRONZE BEARING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. SK50434 W ASHER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Cleveland Range KGT-12-T - page 16

    PIPING ASSEMBL Y T O MAIN GA S S UPPL Y 14 5 6 2 1 4 3 11 10 8 1 3 16 17 7 9 15 ...

  • Cleveland Range KGT-12-T - page 17

    ITEM # P ART # DESCRIPTION QTY . 1. KE01929-1 FEED PIPE ASS'Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE55240-8 GAS V AL VE, NA TURAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE55240-7 GAS V AL VE, C/W L.P . CONVERSION KIT . . . . . . . ...

  • Cleveland Range KGT-12-T - page 18

    Cleveland Range equipment requir es little preventative maintenance. We do however pr ovide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECK LIST The following check should be completed every six months or more frequently if unit is in a high volume facility . ...

  • Cleveland Range KGT-12-T - page 19

    CALIBRA TING PROCEDURE 1. Insure the unit has a vacuum befor e you begin calibrating procedur es. If unit requires venting r efer to Kettle V enting Instructions. 2. Set On-Off Switch/T emperature Control to " 10 " ( Max.). 3. Allow the unit to cycle twice. 4. Check temperature of the inner kettle surface with a digital surface ther momet ...

  • Cleveland Range KGT-12-T - page 20

    RESERVOIR FILL PROCEDURES The kettle's water level must be maintained at the proper level. Under normal operating conditions, the sealed water reservoir should never r equire the addition of water . If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically ...

  • Cleveland Range KGT-12-T - page 21

    KETTLE JACKET CLEANOUT AND P ASSIV A TION PROCEDURES The following procedur e should be preformed at least once ever y three years to pr event possible corrosion and ensure the optimum life of the kettle. DESCRIPTION - Molyfilm 315 inhibits corrosion in stainless steel and copper . A pH buffer is pr esent to assist in maintaining the appropriate pH ...

  • Cleveland Range KGT-12-T - page 22

    KETTLE VENTING INSTRUCTIONS 1. T urn kettle ON and set T emperatur e Control to 10 (Max.), heat the empty kettle until unit cycles off. 2. V ent kettle by pulling safety valve ring 8-10 times in short 2-3 second blasts with a 5 second interval between pulls. NOTE : If unit cycles ON, stop venting and wait for kettle to cycle OFF before continuing. ...

  • Cleveland Range KGT-12-T - page 23

    WIRING DIAGRAM 4 4 10 13 11 15 3 14 12 5 1 2 8 8 9 6 7 ITEM # P ART # DESCRIPTION 1. KE55486-2 L.E.D., RED (USED AFTER JUNE 2005) KE50567-1 L.E.D., RED (USED PRIOR TO JUNE 2005) 2 KE55486-3 L.E.D., GREEN (USED AFTER JUNE 2005) . KE50567-3 L.E.D., GREEN (USED PRIOR TO JUNE 2005) 3. KE55486-2 L.E.D., AMBER (USED AFTER JUNE 2005) KE50567-2 L.E.D., AMB ...

  • Cleveland Range KGT-12-T - page 24

    OPERA TING SEQUENCES 1. T urn On-Off Switch/ * 14 volt transformer is energized and powers solid state control system. T emperatur e Control Knob "ON" * T emperature knob is turned up and control box calls for heat. * Relay (R Y -1) closes and powers 24 volt transformer . * Ignition control box is power ed. 3. Ignitor Sparks * Gas valve i ...

  • Cleveland Range KGT-12-T - page 25

    MARINE LOCK TESTING PROCEDURE 1. Check that lock clears stop pin on side box without rubbing when kettle is tilted (Figure A ). 2. Check side to side play . Lock should remain fully over stop pin when pushed to it's maximum side to side play (Figure B ). 3. Check that the kettle when pushed fully upright moves the lock to a closed position. T ...

Fabricant Cleveland Range Catégorie Hot Beverage Maker

Les documents que nous recevons du fabricant de l'appareilCleveland Range KGT-12-T peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cleveland Range
- manuels d’utilisations KGT-12-T
- fiches produit Cleveland Range
- dépliants
- ou étiquettes-énergie Cleveland Range KGT-12-T
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cleveland Range KGT-12-T.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cleveland Range KGT-12-T, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cleveland Range KGT-12-T. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cleveland Range KGT-12-T.

Manuel d’utilisation complet de l’appareil Cleveland Range KGT-12-T, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cleveland Range KGT-12-T par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cleveland Range KGT-12-T.

Le manuel d’utilisation complet Cleveland Range, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cleveland Range KGT-12-T - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cleveland Range KGT-12-T, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCleveland Range KGT-12-T qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cleveland Range KGT-12-T - qui devraient nous aider dans les premières étapes lors de l'utilisation Cleveland Range KGT-12-T
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cleveland Range KGT-12-T
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cleveland Range KGT-12-T dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cleveland Range KGT-12-T?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cleveland Range KGT-12-T, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cleveland Range KGT-12-T il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)