Manuel d’utilisation MGE UPS Systems 3000 XL

32 pages 0.6 mb
Télécharger

Aller à la page of 32

Summary
  • MGE UPS Systems 3000 XL - page 1

    Installation and user manual www .mgeups.com Pulsar Evolution 2200/3000/3000 XL ...

  • MGE UPS Systems 3000 XL - page 2

    Page 2 - 3400723100/AD SA VE THESE INSTRUCTIONS. This manual contains important instructions for 89347, 89348, and 89349 that should be followed during installation and maintenance of the UPS and batteries. Thank you for selecting an MGE UPS SYSTEMS product to protect your electrical equipment. The Pulsar Evolution range has been designed with the ...

  • MGE UPS Systems 3000 XL - page 3

    3400723100/AD - Page 3 Introduction CAUTION: Safety of persons ◗ The UPS has its own internal power source (the battery). Consequently , the power outlets may be energized even if the UPS is disconnected from the AC-power source. ◗ Dangerous voltage levels are present within the UPS. It should be opened exclusively by qualified service personne ...

  • MGE UPS Systems 3000 XL - page 4

    Page 4 - 3400723100/AD Foreword Using this document IMPORT ANT : Important instructions that must always be followed. NOTE: Information, advice, help. Visual indication. Action. Audio indication. In the illustrations on the following pages, the symbols below are used: LED off. LED on. LED flashing. Information may be found in two ways, using: ◗ t ...

  • MGE UPS Systems 3000 XL - page 5

    3400723100/AD - Page 5 Contents 1. Presentation 1.1 Overall view .................................................................................................................................. 7 T ower position ..................................................................................................................................7 Rack ...

  • MGE UPS Systems 3000 XL - page 6

    Page 6 - 3400723100/AD Contents 6. Appendices 6.1 T echnical data ..............................................................................................................................24 Simplified diagram ..........................................................................................................................24 T echnical ...

  • MGE UPS Systems 3000 XL - page 7

    3400723100/AD - Page 7 1. Presentation 1.1 Overall view T ower position Rack position P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0 W H D Dimensions in inches (W x H x D) Evolution 2200 Evolution 3000 17.24 (19") x 3.56 (2U) x 25.2 Evolution 3000 XL Weight in lbs Evolution 2200 75 Evolution 3000 82 Evolution 3000 XL 46 ...

  • MGE UPS Systems 3000 XL - page 8

    5-20P 72Vdc, 7Ah Pb 344-50 2 8 2 -00 TO B A TTERY C A B IN ET R S 2 3 2 S I TE W I R IN G 3 b attery c a b inets max F A UL T W A R NIN G O U T D ata l ine p r o te c ti o n IN H ert z 50 /6 0 Hz H ert z 50 /6 0 Hz A m p s 1 6 A M A X V ol t 1 2 0 V ~ 1 O V ol t 1 2 0 V ~ 1 O W / VA 1 540 W / 1 9 2 0 VA V ol t : 72Vdc 40 A A C O u t p u t A C I n p ...

  • MGE UPS Systems 3000 XL - page 9

    3400723100/AD - Page 9 1 2 % % 1.3 Control panel Bar graph indicating percent load at output. Group 1 programmable receptacles supplied with power . Illuminated ON/OFF button for the receptacles. Group 2 programmable receptacles supplied with power . Operation on battery power . 15 16 17 20 19 23 22 18 21 1. Presentation UPS fault. Battery fault. O ...

  • MGE UPS Systems 3000 XL - page 10

    P U L S A R Evolution 3 0 0 0 Page 10 - 3400723100/AD 2. Installation 2.1 Unpacking and parts check RS232 communications cable for Windows Operating Systems. For UNIX/Linux Operating Systems, please order , for free, the following part number: 66090 USB communications cable. T elescopic rails for mounting in 19" bay with mounting hardware. T w ...

  • MGE UPS Systems 3000 XL - page 11

    3400723100/AD - Page 11 2. Installation 2.2 Upright installation (tower position) Connect the two supports for the upright position. P U L S A R Evolution 3 0 0 0 P U L S A R Evolution 3 0 0 0 ...

  • MGE UPS Systems 3000 XL - page 12

    P U L S A R Evolution 3 0 0 0 ...

  • MGE UPS Systems 3000 XL - page 13

    3400723100/AD - Page 13 H ert z 50 /6 0 Hz H ert z 50 /6 0 Hz A m p s 1 6 A M A X V ol t 1 2 0 V ~ 1 O V ol t 1 2 0 V ~ 1 O W / VA 1 540 W / 1 9 2 0 VA V ol t : 72Vdc 40 A A C O u t p u t A C I n p u t U . S . P A T . N o . 6 , 0 9 4 , 3 6 3 B A TTERY C O NN E C TOR U . P . S . R 34 Z 5 A C I n p u t P r o g ramma b l e 2 P r o g ramma b l e 1 A C ...

  • MGE UPS Systems 3000 XL - page 14

    Only for 3000 72Vdc, 9Ah Pb 344-50297-00 TO BATTERY RS232 CABINET IN SITE WIRING FAULT max for 3000XL max for 3000 12 battery cabinets WARNING 3 battery cabinets OUT Data line protection Volt: 72Vdc 40A BATTERY CONNECTOR U.S. PAT. No. 6,094,363 Page 14 - 3400723100/AD Only for 3000 72Vdc, 9Ah Pb 344-50297-00 TO BATTERY RS232 CABINET IN SITE WIRING ...

  • MGE UPS Systems 3000 XL - page 15

    3400723100/AD - Page 15 2. Installation 2.7 Installation of the communications-card option 1 - Remove the slot cover 5 secured by two screws. 2 - Insert the card in the slot. 3 - Secure the cover with the two screws. It is not necessary to shut down the UPS to install the communications card. Slot for the communications-card option. 5 Only for 3000 ...

  • MGE UPS Systems 3000 XL - page 16

    Page 16 - 3400723100/AD 1 2 % % 3. Operation 3.1 Start-up 15 16 17 Press the ON / OFF button 15 . The buzzer beeps and all the LEDs come ON. The buzzer beeps twice during the self-test, then button 15 remains ON, indicating that the receptacles are supplied with power . - AC power is present : Only button 15 is ON. The protected equip- ment is supp ...

  • MGE UPS Systems 3000 XL - page 17

    3400723100/AD - Page 17 1 2 % % 1 2 % % 3. Operation 3.3 Operation on battery power (following failur e of AC-input power) T ransfer to battery power The AC-input power is out of tolerances, LED 16 goes ON. During operation on battery power , the buzzer beeps every ten seconds. The equipment connected to the UPS is supplied by the battery . Thresho ...

  • MGE UPS Systems 3000 XL - page 18

    Page 18 - 3400723100/AD 3. Operation 3.4 Personalization (optional) Function Configurable function Automatic restart Cold start Forced reboot Energy saving UPS ON / OFF via software Default setting Enabled Enabled Enabled Disabled Enabled Personalization parameters can be set and modified using the UPS Driver software installed on a computer that i ...

  • MGE UPS Systems 3000 XL - page 19

    3400723100/AD - Page 19 3. Operation Configurable function Output voltage on battery power Upper threshold for transfer to battery power Fader-mode cut-in threshold Booster-mode cut-in threshold Lower threshold for transfer to battery power Maximum input-voltage range Default setting 120 V 151 V 132 V 102 V 89 V Disabled Options 100 V - 127 V 141 V ...

  • MGE UPS Systems 3000 XL - page 20

    Page 20 - 3400723100/AD T roubleshooting requiring MGE UPS SYSTEMS after-sales support 4. Maintenance 4.1 T rouble-shooting Indication LED 17 goes ON and the buzzer sounds continuously . Signification UPS electronics have detected a UPS fault. ◗ The connected equipment is no longer supplied. The equipment connected to the UPS is no longer protect ...

  • MGE UPS Systems 3000 XL - page 21

    3400723100/AD - Page 21 ...

  • MGE UPS Systems 3000 XL - page 22

    Page 22 - 3400723100/AD I H F G 4. Maintenance Installation of the new battery module Carry out the above operation in reverse order . ◗ CAUTION: risk of electric arc when connecting the battery . ◗ T o maintain an identical level of performance and safety , use a battery module identical to that previously mounted in the UPS. ◗ Press the two ...

  • MGE UPS Systems 3000 XL - page 23

    3400723100/AD - Page 23 5. Environment This product has been designed to respect the environment: It does not contain CFCs or HCFCs. UPS recycling at the end of service life: MGE UPS SYSTEMS undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (c ...

  • MGE UPS Systems 3000 XL - page 24

    Page 24 - 3400723100/AD 6. Appendices 6.1 T echnical data Simplified diagram Input Output Battery Charger Inverter Booster / fader transformer Filter ...

  • MGE UPS Systems 3000 XL - page 25

    3400723100/AD - Page 25 6. Appendices T echnical characteristics Output rating AC-input power ◗ V oltage ◗ Frequency Output power (operation on battery power) ◗ V oltage ◗ Frequency Battery Environment ◗ Noise level (operation on AC-input power) ◗ Operating temperature ◗ Relative humidity Pulsar Evolution 2200 1920 V A / 1540 W (1) 6 ...

  • MGE UPS Systems 3000 XL - page 26

    Page 26 - 3400723100/AD 6. Appendices Examples of battery backup times Pulsar Evolution 2200 Pulsar Evolution 3000 Pulsar Evolution 3000 XL + 3 EXB 1 data server + 1 hard disk 2 distributed servers + 1 hub 8 rack-mounted servers 1 data server + 1 hard disk 4 distributed servers + 1 hub + 1 router 12 rack-mounted servers 1 telecom device 1 set of te ...

  • MGE UPS Systems 3000 XL - page 27

    3400723100/AD - Page 27 6. Appendices 6.2 Glossary Backup time T ime that the connected equipment can operate on battery power if AC-input power fails. Bar graph Device on the front panel indicating the percent remaining backup time or the percent load. Battery module (additional) Additional battery modules connected in parallel to increase the UPS ...

  • MGE UPS Systems 3000 XL - page 28

    Page 28 - 3400723100/AD 6. Appendices 6.3 Index A Automatic start ................................................................18 B Bar graph ..........................................................................9 Battery Additional modules ....................................................8 Backup time .................................... ...

  • MGE UPS Systems 3000 XL - page 29

    ...

  • MGE UPS Systems 3000 XL - page 30

    ...

  • MGE UPS Systems 3000 XL - page 31

    ...

  • MGE UPS Systems 3000 XL - page 32

    1660 Scenic Avenue Costa Mesa, CA 92626 USA www .mgeups.com ...

Fabricant MGE UPS Systems Catégorie Surge Protector

Les documents que nous recevons du fabricant de l'appareilMGE UPS Systems 3000 XL peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques MGE UPS Systems
- manuels d’utilisations 3000 XL
- fiches produit MGE UPS Systems
- dépliants
- ou étiquettes-énergie MGE UPS Systems 3000 XL
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation MGE UPS Systems 3000 XL.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation MGE UPS Systems 3000 XL, manuels d’entretien, brefs manuels ou manuels de l’utilisateur MGE UPS Systems 3000 XL. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit MGE UPS Systems 3000 XL.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil MGE UPS Systems 3000 XL, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser MGE UPS Systems 3000 XL par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs MGE UPS Systems 3000 XL.

Le manuel d’utilisation complet MGE UPS Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel MGE UPS Systems 3000 XL - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières MGE UPS Systems 3000 XL, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMGE UPS Systems 3000 XL qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil MGE UPS Systems 3000 XL - qui devraient nous aider dans les premières étapes lors de l'utilisation MGE UPS Systems 3000 XL
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de MGE UPS Systems 3000 XL
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service MGE UPS Systems 3000 XL dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de MGE UPS Systems 3000 XL?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec MGE UPS Systems 3000 XL, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec MGE UPS Systems 3000 XL il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image