    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 1 INSTALLATION INSTRUCTIONS SEALED COMBUSTION DOWNFLOW MGD SERIES GAS FURNACE SIZES 60, 75, 90 FOR INSTALLATION IN: MANUFACTURED (MOBILE) CAUTION: READ ALL SAFETY GUIDES HOMES, RECREATIONAL VEHICLES, PARK MODELS, BEFORE INSTALLING ...

  • Heat Controller MGD90-E3A - page 2

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 2 SPECIFICATIONS 80 A FUE- AU TOMA TIC HOT SURFA CE IGNITION Model No. MGD60-E3A MGD75-E3A MGD90-E3 A MGD60-E5A MGD75-E5A MGD90-E5A Input, BTUH 60,000 75,000 90,000 60,000 75,000 90,000 Output, BTUH 48,000 60,000 72,000 48,000 60, ...

  • Heat Controller MGD90-E3A - page 3

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 3 SAFETY CONSIDERATIONS INSTALLATION STANDARDS CODE COMPLIANCE The installer shall become familiar with and follow all local codes and regulations which govern the i nstallation of t his furnace. Where applicable, local codes may ...

  • Heat Controller MGD90-E3A - page 4

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 4 RETURN AIR ALCOVE INSTRUCTION The furnace may be installed free standing or in an alcove with a free flow of air back to the furnace. A minimum of 18” shall be provided at the front for return air and service access. CLOSET IN ...

  • Heat Controller MGD90-E3A - page 5

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 5 ...

  • Heat Controller MGD90-E3A - page 6

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 6 ...

  • Heat Controller MGD90-E3A - page 7

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 7 SEALED COMBUSTION ROOF JACK – (REQUIRED) ...

  • Heat Controller MGD90-E3A - page 8

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 8 CUTTING ROOF JACK OPENING A proper installation of the roof jack requires that openings in roof and ceiling be on the same vertical centerline as the furnace flue collar. See FIG. 1 Mark the center point on t he ceiling and scri ...

  • Heat Controller MGD90-E3A - page 9

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Instructions 9 CONNECT POWER SUPPLY 1. Remove the furnace control panel cover. 2. Insert 115 V wiring through a strai n relief bushing on the left side of the furnace. 3. Connect the HOT wire to the black pigtail lead; connect the NEUTRAL wire ...

  • Heat Controller MGD90-E3A - page 10

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Inst ructions 10 GAS PIPE AND TUBING-MIN SIZES MODEL TYPE LENGTH PIPE TUBING MGD OF SIZE SIZE GAS (FT.) (IN.) (IN. OD) to 20 3/8 5/8 Natural to 60 1/2 - 60 to 70 - 3/4 to 40 3/8 - Propane to 70 - 5/8 to 80 1/2 - to 20 - 5/8 to 50 1/2 - Natural ...

  • Heat Controller MGD90-E3A - page 11

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Inst ructions 11 WIRING DIAGRAM, MGD ...

  • Heat Controller MGD90-E3A - page 12

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Inst ructions 12 REPLACEMENT PARTS ...

  • Heat Controller MGD90-E3A - page 13

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Inst ructions 13 MGD Gas Furnace Parts List ITEM NO. USED ON FURNACE MODEL PART NO. QTY DESCRIPTION 1 All R68DD0010 1 Pressure Switch, -0.20 N.O. 2 All R71CA0006 2 ft. Silicon Tubing 3 All R68CA0005 1 Limit Switch, Manual, Upper-180F 4 All R86 ...

  • Heat Controller MGD90-E3A - page 14

    MGD Series Gas Furnace Installation Inst ructions Heat Controller, Inc. Jackson, MI 49203 MGD Installation Inst ructions 14 Reference: NFPA No. 54, ANSI Z 223.1 National Fuel Gas Code Table shows 4% Input Reducti on per 1,000 feet elevation For Canadian High Altitude (2,000-4, 500 feet), reduce gas pressure to burner manifold (manifold Ps.) to 3.0? ...

Fabricant Heat Controller Catégorie Furnace

Les documents que nous recevons du fabricant de l'appareilHeat Controller MGD90-E3A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Heat Controller
- manuels d’utilisations MGD90-E3A
- fiches produit Heat Controller
- dépliants
- ou étiquettes-énergie Heat Controller MGD90-E3A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Heat Controller MGD90-E3A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Heat Controller MGD90-E3A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Heat Controller MGD90-E3A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Heat Controller MGD90-E3A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Heat Controller MGD90-E3A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Heat Controller MGD90-E3A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Heat Controller MGD90-E3A.

Le manuel d’utilisation complet Heat Controller, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Heat Controller MGD90-E3A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Heat Controller MGD90-E3A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHeat Controller MGD90-E3A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Heat Controller MGD90-E3A - qui devraient nous aider dans les premières étapes lors de l'utilisation Heat Controller MGD90-E3A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Heat Controller MGD90-E3A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Heat Controller MGD90-E3A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Heat Controller MGD90-E3A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Heat Controller MGD90-E3A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Heat Controller MGD90-E3A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)