  • Vermont Casting EWF36 - page 1

    EWF36A Fireplace Homeowner ’ s Installation and Operating Manual Do Not Discard This Manual: Retain for Future Use 20005167 1/08 Rev . 14 5167 EP A36 cover 3/02 SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAIN- T AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. ...

  • Vermont Casting EWF36 - page 2

    2 V ermont Castings EWF36A 20005167 Introduction Thank you for purchasing a V ermont Castings, EWF36A fireplace. An efficient fireplace carefully engineered to bring you the latest in wood combustion principles and modern foundry technology . Y ou can count on years of comfortable heating and pleasurable fire viewing if you treat it properly an ...

  • Vermont Casting EWF36 - page 3

    3 V ermont Castings EWF36A 20005167 Safety Information Please Read This Manual Before Installing and Using Fireplace IMPORT ANT : Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty . Description The EWF36A fireplace is a so ...

  • Vermont Casting EWF36 - page 4

    4 V ermont Castings EWF36A 20005167 Specifications Range of heat output* ............... 1 1,300 - 75,500 Btu/hr Maximum heat output** ..... in excess of 100,000 Btu/hr EP A emissions rating (g/h, catalytic) .......................2.4* Area heated*** ............... Up to 2500 sq. ft. (558 sq. m) Size of wood splits ..................... 18” - 2 ...

  • Vermont Casting EWF36 - page 5

    5 V ermont Castings EWF36A 20005167 Fig. 2 Fireplace and chase parts identification. FP554a FP554a BFC Fireplace and chase parts identification circulating model 8/21/00 djt Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation. T ermination Cap Storm Collar Pan Flashing Draftstop Batt Insu ...

  • Vermont Casting EWF36 - page 6

    6 V ermont Castings EWF36A 20005167 D Rise B G H B Offset C E 6 FT . G H A Hearth Floor Chimney Section CHIMNEY FLUE EXIT Elbow FP269 MBUF 5/16/96 rev . 5/25 TCS8A Support Example 1 Example 2 Example 3 Chimney Requirements - Offset Installations Notes: G + H cannot exceed 20 feet. Air Space Clearances: “S” Series (3-wall) = 2” Min. to Combust ...

  • Vermont Casting EWF36 - page 7

    7 V ermont Castings EWF36A 20005167 Planning Information Determine how the chimney will be run, length of run and chimney components required to complete the job. (Fig. 4) Never install a chimney below minimum heights. In planning a chimney system, it is important to know: 1. The height of a chimney is measured from the hearth to the exit point on ...

  • Vermont Casting EWF36 - page 8

    8 V ermont Castings EWF36A 20005167 Chimney Supports The chimney system is supported by the fireplace for vertical chimney heights less than 30’ (9m) above the hearth. Chimney supports are required if the vertical height exceeds 30’ (9m). Locate chimney supports at ceiling holes or other structural framing at 30’ (9m) heights. Spacing betwee ...

  • Vermont Casting EWF36 - page 9

    9 V ermont Castings EWF36A 20005167 Framing Framing can be constructed before or after the fireplace is set in place, however , most installers build the frame before setting the fireplace. Frame fireplace with 2 x 4 lumber or heavier materi- als. Refer to framing dimensions in Figure 1 for basic fireplace specifications. NOTE: Framing should ...

  • Vermont Casting EWF36 - page 10

    10 V ermont Castings EWF36A 20005167 Ceiling Chimney Hole/ Possible Obstructions The size of the hole in ceiling will vary with the angle at which the chimney passes through ceiling. Drive a nail up through ceiling at marked chimney center point. Go to floor above and see where hole will be cut. Check to see where existing ceiling joists and other ...

  • Vermont Casting EWF36 - page 11

    1 1 V ermont Castings EWF36A 20005167 Installating Outside Air Kit An outside air kit may be installed on the EWF36A. If desired, or if local codes mandate the use of an air kit, then two (2) AK-MST s are required to complete the installation (from air kit to the outdoors). If the outside air kits are to be used, the AK-MST s MUST be installed BEFO ...

  • Vermont Casting EWF36 - page 12

    12 V ermont Castings EWF36A 20005167 Installing the Chimney System Start by attaching the first chimney section to the collar on top of the fireplace. Install the pipe as pictured in Figure 16. When you get a good lock, you will hear the pipe clearly snap together . Once sections are snap-locked in place, it is extremely difficult to get them ap ...

  • Vermont Casting EWF36 - page 13

    13 V ermont Castings EWF36A 20005167 Installing the Firestop Spacer in the Ceiling Hole A firestop spacer is used to keep pipe spaced properly and required for safety . Nail the firestop spacer (at each corner) to the framing members of the ceiling hole. NOTE: A firestop spacer is not required at the roof. Hole sizes listed in Figure 9 for angle ...

  • Vermont Casting EWF36 - page 14

    14 V ermont Castings EWF36A 20005167 Penetrating the Roof Run pipe to roofline. Since chimney system must be vented to the out-of-doors, you must use an approved CFM Corporation termination. If a chase is used, refer to the installation manual pro- vided with the termination cap. Locate Chimney Centerpoint on Roof Use same procedure detailed in lo ...

  • Vermont Casting EWF36 - page 15

    15 V ermont Castings EWF36A 20005167 Finish W all Finish the wall with material of your choice. Do not install a combustible mantel shelf less than 12” (305 mm) above the firebox grille opening. Do not install a mantel face plate less than 6” (159 mm) from top of grille opening. (Fig. 20) If a combustible material is used below a flat mantel ...

  • Vermont Casting EWF36 - page 16

    16 V ermont Castings EWF36A 20005167 Examples of wall shield insulation: 1. Manville - CERAFORM 126, K=.27, 1/2 inches thick 2. EH2416, K = .458, 1 inch thick required. Hearth Installation A hearth extension is required to protect a combustible floor in front of the fireplace. Refer to Figure 26 for mini- mum dimensions and mounting detail. NOTE: ...

  • Vermont Casting EWF36 - page 17

    17 V ermont Castings EWF36A 20005167 FP1201 Fig. 26 Combustible side wall protection and hearth extension dimensions. Minimum W all Clearances WITH Noncombustible Surround Facing WITHOUT Noncombustible Surround Facing Minimum Hearth Extension Dimensions (for On-Site Construction) G H G J Seal cracks between the fireplace and hearth extension with n ...

  • Vermont Casting EWF36 - page 18

    18 V ermont Castings EWF36A 20005167 Operation Attach Handles The fallaway handles are used to open and close the front doors. Remove after each use so they will not get hot. Keep in convenient location for each use. (Fig. 27) Assemble the primary air control and damper handles by passing the 3 ³⁄₈ ” screw through the ceramic shaft and into ...

  • Vermont Casting EWF36 - page 19

    19 V ermont Castings EWF36A 20005167 KT108b BFC Correct door position 8/23/00 djt KT108b Fig. 30 Correct door position during operation. Correct Optional Spark Screen Correct The Fan Heated air from the fireplace is forced into the room by an internal fan. The control for the fan is in the right corner of the unit. “Off” is to the far left. ? ...

  • Vermont Casting EWF36 - page 20

    20 V ermont Castings EWF36A 20005167 Starting and Maintaining a Wood Fire Burn solid wood fuel only in the EWF36A, and burn it directly on the grate. Do not elevate the fuel. Do not burn coal or other fuels. Minimize thermal stress by allowing the plates to adjust gradually during an initial break-in fire by following Steps 1-3 below . W ARNING: O ...

  • Vermont Casting EWF36 - page 21

    21 V ermont Castings EWF36A 20005167 Different results may be experienced even in the same installation if you switch from burning good, dry wood to wood that is partially rotted or inadequately seasoned. T o compensate for these factors in cold climates, it may be necessary to operate the EWF36A with the air con - trol set to a higher level more o ...

  • Vermont Casting EWF36 - page 22

    22 V ermont Castings EWF36A 20005167 Keep your EWF36A Fireplace Looking New and Working Its Best Care of the Cast Iron Surface An occa sio nal dus ting wit h a dry ra g wi ll k eep the pa inte d cas t ir on of y our EWF 36A fire plac e l ooki ng n ew. If the paint needs retouching, first allow the surface to cool completely . Wire-brush areas nee ...

  • Vermont Casting EWF36 - page 23

    23 V ermont Castings EWF36A 20005167 When to Suspect a Combustor Problem The bes t w ay t o e valu ate the per for manc e of yo ur EWF 36A’ s c ombu sto r is to obs erve th e am ount of smo ke lea ving th e ch imn ey - bot h w hen the com bust or has “li ghte d-o ff” and whe n it ha s no t. Foll ow t hes e st eps : • With a fire going and ...

  • Vermont Casting EWF36 - page 24

    24 V ermont Castings EWF36A 20005167 Replaceable Fiberglass Gaskets Gasket Size... ...And The Parts It Seals 1/2” The door to the front 5/8” Door to the hearth brick support 3/16” The glass seal to the door 1/2” Cat holder to top plate 1/2” Braided Damper to top plate Should you need to change a replaceable gasket, wait until the fire is ...

  • Vermont Casting EWF36 - page 25

    25 V ermont Castings EWF36A 20005167 The prefabricated chimney used with your fireplace should be cleaned from above using an 8” round brush and the appropriate number of extension rods for com- plete access. The chimney cap first must be removed following the procedure recommended by the manufacturer . After thoroughly cleaning the chimney , r ...

  • Vermont Casting EWF36 - page 26

    26 V ermont Castings EWF36A 20005167 Chimney Components Component Description Model Number Chimney Support Used to support chimney for each of TCS8A 30’ vertical height and 6’ of angled chimney run (8” flue) Firestop Required at each floor level and attic on FS2A (8” straight flue) multi-story installation FS6A (8” 30° inclined flue) ...

  • Vermont Casting EWF36 - page 27

    27 V ermont Castings EWF36A 20005167 1 3 7 5 6 1 1 46 40 13 13 20 22 15 86 15 10 37 36 47 47 45 41 44 16 16 17 39 52 27 28 29 30 31 19 33 34 35 9 54 32 42 43 2 2 4 56 55 52 48 51 50 49 73 74 EWF36CLK 75 75 65 EWF36CLK EWF36CLK 76 76 EWF36CLK 79 79 80 80 82 83 84 85 81 82 83 84 85 EWF36S 24 25 26 24 25 26 18 24 25 26 87 38 62 63 64 EWF36CFTK 24 25 2 ...

  • Vermont Casting EWF36 - page 28

    28 V ermont Castings EWF36A 20005167 22. Glass Right Door - EP A Front 20005152 23. Right, Door Handle Assy . V ert. Nickel 20006286 24. Damper Steel Handle w/Screw 5004265 25. Handle, Ceramic Blk 2.78 Lg 20006381 26. Ov Hd Sl 1/4-20 x 3/375 Lg 1201294 27. Linkage Assy . 20005307 28. Pawl, T op 20005154 29. Pawl, Bottom 20005155 30. Link, EP A FP F ...

  • Vermont Casting EWF36 - page 29

    29 V ermont Castings EWF36A 20005167 Optional Accessories Fan Kit FK26 Fan The FK26 fan helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox tem- perature rises above and falls below a preset tempera- ture. A rheostat provides for variable fan speeds. ...

  • Vermont Casting EWF36 - page 30

    30 V ermont Castings EWF36A 20005167 ...

  • Vermont Casting EWF36 - page 31

    31 V ermont Castings EWF36A 20005167 W arranty Limited 3 Y ear W arranty CFM Corporation warrants that this woodburning stove will be free of defects in material and workmanship for a period of three years from the date you receive it, except that the catalyst, thermostat assembly , handles, glass door panels, cement, and gasketing shall be warrant ...

  • Vermont Casting EWF36 - page 32

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 • www .cfmcorp.com CFM Corporation ...

Fabricant Vermont Casting Catégorie Outdoor Fireplace

Les documents que nous recevons du fabricant de l'appareilVermont Casting EWF36 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vermont Casting
- manuels d’utilisations EWF36
- fiches produit Vermont Casting
- dépliants
- ou étiquettes-énergie Vermont Casting EWF36
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vermont Casting EWF36.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vermont Casting EWF36, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vermont Casting EWF36. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vermont Casting EWF36.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vermont Casting EWF36, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vermont Casting EWF36 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vermont Casting EWF36.

Le manuel d’utilisation complet Vermont Casting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vermont Casting EWF36 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vermont Casting EWF36, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVermont Casting EWF36 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vermont Casting EWF36 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vermont Casting EWF36
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vermont Casting EWF36
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vermont Casting EWF36 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vermont Casting EWF36?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vermont Casting EWF36, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vermont Casting EWF36 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)