    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 1 Model(s): CERONA-36 CERONA-42 • Do not store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance. • What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any ph ...

  • Hearth and Home Technologies CERONA-42 - page 2

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 2 Congratulations Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: __________________ Serial Number: __________________________________________ Location on appliance: ____________________ Dealership purchased f ...

  • Hearth and Home Technologies CERONA-42 - page 3

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 3  = Contains updated information. T able of Contents 1 Listing and Code Approvals A. Appliance Certi fi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. BTU Speci fi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. High Altitud ...

  • Hearth and Home Technologies CERONA-42 - page 4

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 4 B. BTU Speci fi cations Not e: This installation must c onform wi th local c odes. In the absenc e of local c odes you must c omply wit h the Nation al Fuel Gas Code, A NSI Z2 23. 1- latest edition in th e U .S. A. an d the CA N/CGA B1 49 Inst allation Code s in Canada. 1 1 ...

  • Hearth and Home Technologies CERONA-42 - page 5

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 5 G. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and whe ...

  • Hearth and Home Technologies CERONA-42 - page 6

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 6 A. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the out- side. No additional outside air source is required. 2 2 Get tin ...

  • Hearth and Home Technologies CERONA-42 - page 7

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 7 D. Inspect Firebox Surface cracking or crazing of fi rebrick material is normal and expected. The following types of cracks are acceptable and do not require replacement of the unit or the fi rebox: • Cracks that do not propagate entirely thru the material. • Light frac ...

  • Hearth and Home Technologies CERONA-42 - page 8

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 8 3 3 F raming and Clearances Note: • Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONL Y . • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference. Fire Risk Provide adequate clearance: ...

  • Hearth and Home Technologies CERONA-42 - page 9

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 9 Fire Risk. • Construct chase to all clearance speci fi cations in manual. • Locate and install appliance to all clearance speci fi cations in manual. B. Constructing the Appliance Chase A chase is a vertical boxlike structure built to enclose the gas appliance and/or it ...

  • Hearth and Home Technologies CERONA-42 - page 10

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 10 D. Mantel Projections Figure 3.3 Clearances to mantels or other combustibles above appliance Figure 3.4 Clearances to Mantel Legs or W all Projections (Acceptable on both sides of opening.) NON-COMBUSTIBLE F ACING MA TERIAL COMBUSTIBLE F ACING MA TERIAL 1 in. TYPICAL D MINIM ...

  • Hearth and Home Technologies CERONA-42 - page 11

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 1 1 Fire Risk. Hearth extension required to protect combustible fl oors in front of appliance. • An 8 inch minimum hearth extension must be constructed of non-combustible material. E. Hearth Extension W ARNING Figure 3.6 Hearth Extension Dimensions AB Cerona-36 in. 41-1/8 8 ...

  • Hearth and Home Technologies CERONA-42 - page 12

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 12 A. V ent T ermination Minimum Clearances Fire Risk. Explosion Risk. Maintain vent clearance to combustibles as speci fi ed. • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials away from vent pipe may cause fi re. Roof ...

  • Hearth and Home Technologies CERONA-42 - page 13

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 13 V = VENT TERMINAL X = AIR SUPPL Y INLET = AREA WHERE TERMINAL IS NOT PERMITTED Figure 4.4 Minimum Clearances for T ermination A = 12 inches................. clearances above grade, ver anda, porch, deck or balcony B = 12 inches................. clearances to window or door t ...

  • Hearth and Home Technologies CERONA-42 - page 14

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 14 B. Continue Adding V ent Components T o Install the Heat Shield: 1. Determine if the heat shield is required. Do so by measuring the vertical distance between the top horizontal surface of the elbow to any combustible surface above. If the distance is more than 4 inches, the ...

  • Hearth and Home Technologies CERONA-42 - page 15

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 15 Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid-fuel or gas burning appliance. • V ent this appliance directly outside. • Use separate vent system for this appliance. May impair safe operation ...

  • Hearth and Home Technologies CERONA-42 - page 16

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 16 H 1 V 1 Figure 5.3 Figure 5.4 D. V ent Diagrams 1. T op V ent - Horizontal T ermination One Elbow T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 Fire Risk. Explosion Risk. Do NOT pack insulation or other combustibles between ceiling fi restops. • AL W A YS maintain spe ...

  • Hearth and Home Technologies CERONA-42 - page 17

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 17 Figure 5.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows 2. T op V ent - V ertical T ermination Straight up V ertical V enting V 1 = 50 ft. Max. (15.2 m) V 1 Minimum H 1 Maximum Cerona-36 ONL Y 1/2 ft 152 mm 3 ft 914 mm 1 ft 305 mm 4 ft 1.2 m 2 ft 610 mm ...

  • Hearth and Home Technologies CERONA-42 - page 18

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 18 Figure 5.7 Figure 5.8 Three Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 2 V 1 V 1 Minimum H 1 Maximum Cerona-36 ONL Y 1/2 ft 152 mm 2 ft 610 mm 1 ft 305 mm 2 ft 610 mm 2 ft 610 mm 5 ft 1.5 m 3 ft 914 mm 8 ft 2.4 m 4 ft 1.2 m 1 1 ft 3.4 m 5 ft 1.5 m 14 ft 4.3 m 6 ft 1.8 m 17 f ...

  • Hearth and Home Technologies CERONA-42 - page 19

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 19 A. Pipe Clearances to Combustibles 6 6 V ent Clearances and F raming B. W all Penetration Framing Combustible W all Penetration Frame a hole in a combustible wall for an interior wall shield fi restop, (Figure 6.3) whenever a wall is penetrated. Use same size framing materi ...

  • Hearth and Home Technologies CERONA-42 - page 20

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 20 C. V ertical Penetration Framing Installing the Ceiling Firestop • Frame an opening 10 inches by 10 inches whenever the vent system penetrates a ceiling/ fl oor (see Figure 6.4). • Frame the area with the same sized lumber as used in ceiling/ fl oor joist. • When ins ...

  • Hearth and Home Technologies CERONA-42 - page 21

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 21 7 7 Appliance Preparation A. Removing Non-combustible Facing Mate- rial Assembly The non-combustible assembly is located on the back of appliance (see Figure 7.1). Figure 7.1 Non-Combustible Facing Material Assembly • Hold non-combustible pieces in place. • Remove and sa ...

  • Hearth and Home Technologies CERONA-42 - page 22

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 22 CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. C. Installing Non-combustible Facing Material Figure 7.3 Attaching Non-combustible Facing Material Fire Risk. • Follow these instructions exactly . • Facing materials must be installed ...

  • Hearth and Home Technologies CERONA-42 - page 23

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 23 D. Installing Flue Restrictors Locate the fl ue restrictor and two screws inside the manual bag. Use the following table to determine which restrictors to use for the vent run. V ent Run V ertical 15 ft. - 50 ft. Cerona-36 1-1/4 Cerona-42 1-1/4 Figure 7.5 • Attach the lef ...

  • Hearth and Home Technologies CERONA-42 - page 24

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 24 Make sure that the fi berglass rope ring supplied in the manual bag seals between the fi rst v ent component and the outer appliance wrap (see Figure 8.1). Figure 8.1 Fiberglass Rope Ring FIRST VENT COMPONENT FIBERGLASS ROPE RING OUTER WRAP Fire Risk Exhaust Fumes Risk Imp ...

  • Hearth and Home Technologies CERONA-42 - page 25

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 25 Figure 8.5 Seams Note: Make sure that the seams are not aligned to prevent unintentional disconnection. INCORRECT CORRECT Assembling DVP-12A Slip Sections The outer fl ue of the slip section should slide over the outer fl ue of the pipe section and into (inner fl ue) the ...

  • Hearth and Home Technologies CERONA-42 - page 26

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 26 C. Disassembly of V ent Sections T o disassemble any two pieces of pipe, rotate either section (see Figure 8.1 1), so that the seams on both pipe sections are aligned (see Figure 8.12). They can then be carefully pulled apart. B. Securing the V ent Sections V ertical Section ...

  • Hearth and Home Technologies CERONA-42 - page 27

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 27 D. Installing Heat Shield and Horizontal T ermination Cap Note: Where required, an exterior wall fl ashing is available. When penetrating a brick wall, a brick extension kit is available for framing the brick. Heat Shield Requirements for Horizontal T ermination For all hor ...

  • Hearth and Home Technologies CERONA-42 - page 28

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 28 SCREWS CAULK STORM COLLAR (1 of 3) E. Installing Roof Flashing and V ertical T er- mination Cap T o install roof fl ashing see Figure 8.16. For installation of vertical termination cap see minimum vent heights for various pitched roofs (see Figure 8.14). Caulk the gap betwe ...

  • Hearth and Home Technologies CERONA-42 - page 29

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 29 Figure 8.17 Assembling the Storm Collar Figure 8.18 Assembling the Storm Collar Around the Pipe Connect both halves of the storm collar with two screws (see Figure 8.17). Wrap the storm collar around the exposed pipe section and align brackets. Insert a bolt (provided) throu ...

  • Hearth and Home Technologies CERONA-42 - page 30

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 30 Note: Hav e the gas supp ly line installed in acc ordanc e w i t h l o c a l b u i l d i n g c o d e s , i f a n y . I f n o t , f o l l o w A N S I 223. 1 . Installation shou ld b e done by a quali fi ed ins taller approv ed and/or li censed as requ ired b y the locality . ...

  • Hearth and Home Technologies CERONA-42 - page 31

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 31 Fire hazard. Do NOT change the valve settings. • This valve has been preset at the factory . • Changing valve settings may result in fi re hazard or bodily injury . HIGH AL TITUDE INST ALLA TIONS U.L. Listed gas appliances are tested and approved without requiring chang ...

  • Hearth and Home Technologies CERONA-42 - page 32

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 32 A. Recommendation for Wire This appliance requires 1 10-120 V AC be wired to the junction box for proper operation of the appliance. This appliance uses an Intelli fi re ignition system. 1 0 10 Elec tric al Information Note: This appliance must be electrically wired and gro ...

  • Hearth and Home Technologies CERONA-42 - page 33

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 33 WHITE JUNCTION BOX STRAIN RELIEF CONNECTOR FRONT OF FIREPLACE COPPER GROUND A TT ACHED TO GROUND SCREW WITH GROUND WIRE HEA T SHIELD BOTTOM P AN GROUND WIRE INSIDE BOX BLACK 14/2WG Figure 10.1 Intelli fi re Pilot Ignition (IPI) W iring Diagram D. Junction Box Installation F ...

  • Hearth and Home Technologies CERONA-42 - page 34

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 34 Note TO APPLIANCE INST ALLERS: T o protect appliance after installation, but before use, please replace corrugated splatterguard on unit per directions noted below . STEP 1 For Cerona-36, center left to right over glass and fold top center section under top heat shield as in ...

  • Hearth and Home Technologies CERONA-42 - page 35

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 35 A. Mantel Projections Figure 1 1.1 shows the minimum vertical and correspond- ing maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance. 1 1 11 Finishing Figure 1 1.1 Clearances to mantels or other combu ...

  • Hearth and Home Technologies CERONA-42 - page 36

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 36 B. Facing Material Fire Risk. Finish all edges and fronts to clearances and speci fi cations listed in manual. • Black metal appliance front may be covered with noncombustible material only . • Do NOT overlap combustible materials onto appliance front. • Install combu ...

  • Hearth and Home Technologies CERONA-42 - page 37

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 37 C. Finishing Material Options Finishing Material Thickness from 3/4 in. to 1-1/4 in. Finishing material within this thickness range can be brought to 1/2 inch behind the door top and sides. These non-combustible fi nishing materials must never overlap or obstruct the air ou ...

  • Hearth and Home Technologies CERONA-42 - page 38

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 38 Fire Risk. Hearth extension required to protect combustible fl oors in front of appliance. • An 8 inch minimum hearth extension must be constructed of non-combustible material. D. Hearth Extension W ARNING Figure 1 1.9 Hearth Extension Dimensions AB Cerona-36 in. 41-1/8 8 ...

  • Hearth and Home Technologies CERONA-42 - page 39

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 39 1 2 12 Appliance Setup A. Remove Shipping Materials Remove shipping materials from inside or underneath the fi rebox. B. Clean the Appliance Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity . C. Accessories Install ...

  • Hearth and Home Technologies CERONA-42 - page 40

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 40 E. Positioning the Logs Model: Cerona-36 If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. Log Assembly: LOGS-Cerona36 CAUTION: Carefully remove the logs from th ...

  • Hearth and Home Technologies CERONA-42 - page 41

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 41 STEP 4. LOG #4 (SRV2106-704): Log #4 is form fi tted to the burner . It sits on the middle portion of the burner as shown. 4 4 5 5 Figure 12.8 Figure 12.9 Figure 12.10 STEP 5. LOG #5 (SRV2106-702): Place the right portion of log #5 on the formed area of log #1. Place the le ...

  • Hearth and Home Technologies CERONA-42 - page 42

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 42 Model: Cerona-42 If the gas logs have been factory installed they should not need to be positioned. If the logs have been packaged separately , refer to the following instructions. CAUTION: Carefully remove the logs from the packaging. Logs are fragile! STEP 1. LOG #1 (SRV21 ...

  • Hearth and Home Technologies CERONA-42 - page 43

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 43 STEP 3. LOG #3 (SRV 2107-703 ): Place the notch on the tip of log #3 over the locating tab on log #1. Place the left leg of the log on the far left grate tine (A) . See Figure 12.15. STEP 4. LOG #4 (SRV2107-704): Place the left formed end of log #4 on the burner detail locat ...

  • Hearth and Home Technologies CERONA-42 - page 44

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 44 Figure 12.19 Glass Assembly F . Glass Assembly Removing Glass Assembly Pull the four glass assembly latches out of the groove on the glass frame. Remove glass door from the appliance (see Figure 12.19). Replacing Glass Assembly Replace the glass door on the appliance. Pull o ...

  • Hearth and Home Technologies CERONA-42 - page 45

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 45 A. Before Lighting Appliance This appliance has an Intelli fi re ignition system. 1 3 13 Op erating Instr uctions CAUTION If installing Intelli fi re ignition battery backup: • Do not install batteries if the backup mode may not be used for extended time. • Batteries m ...

  • Hearth and Home Technologies CERONA-42 - page 46

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 46 B. Lighting Appliance 1. T urn off all electric power to the appliance. 2. This appliance is equipped with an ignition device which automatically lights the burner . Do not try to light the burner by hand. 3. Wait fi ve (5) minutes to clear out any gas. Then smell for gas, ...

  • Hearth and Home Technologies CERONA-42 - page 47

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 47 Initial Break-in Procedure When you light the appliance, you may notice that it pro- duces heat which does have an associated odor or smell. If you feel this odor is excessive it may require the initial three to four hour continuous burn on high followed by a second burn up ...

  • Hearth and Home Technologies CERONA-42 - page 48

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 48 1 4 14 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a quali fi ed service person in the diagnosis of a problem and ...

  • Hearth and Home Technologies CERONA-42 - page 49

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 49 Intelli fi re Ignition System - (continued) Symptom Possible Cause Corrective Action 3. (Continued) Pilot lights but continues to spark, and main burner will not ignite. (If the pilot contin- ues to spark after the pilot fl ame has been lit, fl ame recti fi cation has no ...

  • Hearth and Home Technologies CERONA-42 - page 50

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 50 1 5 15 Maintaining and Ser v icing Applianc e Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a quali fi ed service technician should perform an appliance checkup at the beginning of each heating season. Annual ...

  • Hearth and Home Technologies CERONA-42 - page 51

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 51 Inspect Maintenance T asks Doors, Surrounds and Fronts 1. Assess condition of screen and replace as necessary . Recommend addition of screen if one is not present. 2. Inspect for scratches, dents or other damage and repair as necessary . 3. V erify no obstructions to air fl ...

  • Hearth and Home Technologies CERONA-42 - page 52

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 52 1 6 16 R eference Mater ials G A MINIMUM VERTICAL RISE REQUIRED BEFORE 90° ELBOW Ø GAS LINE ACCESS ELECTRICAL ACCESS C B D H E F I J K P L M N O Q R A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. Fo r framing dimensions a ...

  • Hearth and Home Technologies CERONA-42 - page 53

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 53 B. V ent Components Diagrams Figure 16.2 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in. (235 mm) 13-1/4 in. (337 mm) 1/2 in. TYP DVP90ST (90° Elbow) 10 in. (254 mm) 1 in. (25 mm) 12 in. (3 ...

  • Hearth and Home Technologies CERONA-42 - page 54

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 54 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-HPCK1-B DVP-HPCK2-B DVP-TRAPK1 DVP-TRAPK2 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield ...

  • Hearth and Home Technologies CERONA-42 - page 55

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 55 B. V ent Components Diagrams (continued) Figure 16.4 DVP vent components 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extensi ...

  • Hearth and Home Technologies CERONA-42 - page 56

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 56 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap Not for use with these models 7-1/4 in. (184 mm) 5-1/4 in. (133 mm) 12-1/2 in. (318 mm) DVP-TVHW VerticalTermination Cap (Highwind) PVK-80 (For use with IPI and DSI appliances only.) 14 in. (356 mm) 12 in. ...

  • Hearth and Home Technologies CERONA-42 - page 57

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 57 C. Service Parts CERONA-36 Beginning Manufacturing Date: June 2006 Ending Manufacturing Date: ______ Service Parts Diagram Part number list on following page. Log Set Assembly 7 8 9 10 11 12 13 14 5 6 4 1 2 3 ...

  • Hearth and Home Technologies CERONA-42 - page 58

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 58 Service Parts List CERONA-36 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ...

  • Hearth and Home Technologies CERONA-42 - page 59

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 59 Service Parts CERONA-36 Beginning Manufacturing Date: June 2006 Ending Manufacturing Date: ______ IPI V alve Assembly IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All ...

  • Hearth and Home Technologies CERONA-42 - page 60

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 60 Service Parts CERONA-42 Beginning Manufacturing Date: June 2006 Ending Manufacturing Date: ______ 14 7 8 9 10 11 12 13 Part number list on following page. Log Set Assembly 5 6 3 4 2 1 Service Parts Diagram ...

  • Hearth and Home Technologies CERONA-42 - page 61

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 61 IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number . All parts listed in this manual may be ordered from an authorized dealer . Stocked at Depot ITEM DESCRIPTION COMMENTS P A ...

  • Hearth and Home Technologies CERONA-42 - page 62

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 62 Service Parts CERONA-42 Beginning Manufacturing Date: June 2006 Ending Manufacturing Date: ______ V alve Assembly Diagram/ Parts List IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and ser ...

  • Hearth and Home Technologies CERONA-42 - page 63

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 63 D. Limited Lifetime W arranty Hearth & Home T echnologies LIMITED W ARRANTY Hearth & Home T echnologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and ...

  • Hearth and Home Technologies CERONA-42 - page 64

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 64 D. Limited Lifetime W arranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. ...

  • Hearth and Home Technologies CERONA-42 - page 65

    Heat & Glo • Cerona-36, Cerona-42 • 2106-900 Rev . H • 1 1/08 65 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215th St., Lakeville, MN 55044 www .heatnglo.com E. Contact Information Please contact your Heat & Glo dealer with any questions or concerns. For the location of your nearest Heat & Glo dealer , ple ...

Fabricant Hearth and Home Technologies Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilHearth and Home Technologies CERONA-42 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Hearth and Home Technologies
- manuels d’utilisations CERONA-42
- fiches produit Hearth and Home Technologies
- dépliants
- ou étiquettes-énergie Hearth and Home Technologies CERONA-42
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Hearth and Home Technologies CERONA-42.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Hearth and Home Technologies CERONA-42, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Hearth and Home Technologies CERONA-42. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Hearth and Home Technologies CERONA-42.

Manuel d’utilisation complet de l’appareil Hearth and Home Technologies CERONA-42, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Hearth and Home Technologies CERONA-42 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Hearth and Home Technologies CERONA-42.

Le manuel d’utilisation complet Hearth and Home Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Hearth and Home Technologies CERONA-42 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Hearth and Home Technologies CERONA-42, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHearth and Home Technologies CERONA-42 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Hearth and Home Technologies CERONA-42 - qui devraient nous aider dans les premières étapes lors de l'utilisation Hearth and Home Technologies CERONA-42
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Hearth and Home Technologies CERONA-42
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Hearth and Home Technologies CERONA-42 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Hearth and Home Technologies CERONA-42?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Hearth and Home Technologies CERONA-42, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Hearth and Home Technologies CERONA-42 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)