    Installatio n, Oper ation, & Maintenan ce Instruc tion Models DC2, 3, 4, 5, and 6 Bulletin #: IO M-OM-1104- E Manufacturers of Quality Pumps, Controls, and Systems STANDARD PUMP OPERATIONS 27101 Airport Road Punta Gorda, FL 33982 (941) 575-3800 Fax (941) 575 -4085 www.pulsatron.com ® ...

  • Honeywell DC5 - page 2

    ii Pulsafeeder F actory Ser vice Policy Should you experience a problem with your Pulsafeeder pum p, first consult the troubleshooting g uide in your operation and maintenance manual. I f the problem is not covered or cannot be solved, please contact your local Pulsafeeder Sale s Representative or D istributor, or our Technical Services Departm ent ...

  • Honeywell DC5 - page 3

    iii Table of Contents 1. I NTRODUCT ION ....................................................................... ..............................................................1 2. P RINCIPLES O F O PERATION ....................................................................... ...........................................1 2.1 Reagent He ad Assembly ...

  • Honeywell DC5 - page 4

    i v 8.3 KOPkit numb ers by m odel: ....................................................................................................20 9. M ODEL N UMBER I DENTIFICATION ....................................................................... ....................................21 10. W ET E ND M A TERIALS R EFERENCE .............................. ...

  • Honeywell DC5 - page 5

    1 1. Introduction The OMNI ® metering pump is positive displacem ent, mechanically operated reci procating diaphragm pump. Each pump consists of a power end an d a process end separated by a PTFE faced diaphragm . Individual pumps will vary in appearance due to various liquid end s and accessories; however, the basic principles of operation rem ai ...

  • Honeywell DC5 - page 6

    2 2.1 Reagent H ead Assembl y The typical reagent head assem bly consists of reagent head, diaphragm , and suction and discharge cartridge check valves. This assem bly is the only part of the pump to contact the process liquid; consequently, maintenance is critical to pum p performance. 2.2 Control Assembl y The OMNI ® pump incorporates a lost mot ...

  • Honeywell DC5 - page 7

    3 3. Equipment Inspection Check all equipment for com pleteness against the order and for any ev idence of shipping dam age. Shortages or damag e must be reported immediately to the carrier and y our authorized representative or distributor of OMNI ® pumps. 4. Storage 4.1.1 Short Term Storage of your OMNI ® pump for up to 12 months is considered ...

  • Honeywell DC5 - page 8

    4 5.2 Piping S ystem 1. All systems should include a pressu re relief valve on the discharg e side, to protect piping and process equipment, including the pum p, from excess process pressures . A n external relief valve is required! There should be no devic es capable of restricting flow (such as a valve) loca ted between the pump and the relief de ...

  • Honeywell DC5 - page 9

    5 5.3 Suction Pr essur e Requir ements Although OMNI ® metering pumps have some suction lift capability, a flood ed suction (i.e., suction pressure higher than atm ospheric pressure) is preferable whenev er possible. The pum p should be located as close as possible to the suct ion side reservoir or fluid supply source. For fluid with a vapor press ...

  • Honeywell DC5 - page 10

    6 Figure 4, stroke adjustment 6. Equipment Startup 6.1 Fastener In spection All pump fasteners should be check ed prior to pump operation, and occasiona lly during use. This would include reagent head m ounting bolts, motor mounting bolts, and the hardware that secures the pump to its foundation. Most hardware c an be checked simply to ensure it is ...

  • Honeywell DC5 - page 11

    7 6.3 Priming the Reage nt Hea d 1. When handling process liquids, fo llow all applicable personal and fac ility safety guidelines. 2. Ensure that the pump is rea dy for operation and that all process conne ctions are secure. 3. Open the suction and discharge line shuto ff valves. 4. If the piping system design and the storag e tank are such that t ...

  • Honeywell DC5 - page 12

    8 6.4 Calibration Figure 6, sample flow calibration curve All metering pumps must be ca librated to accurately specify stroke length settings for requir ed flow rates. A typical calibration chart is shown abov e. Although output is linear with respect to stroke leng th setting, an increase in discharge pressure decr eases output uniform ly, describ ...

  • Honeywell DC5 - page 13

    9 7. Maintenance B EFORE PERF ORMING ANY MAINTENANCE RE QUIRING RE AGENT HE AD OR V AL VE ( WET E ND ) DISASSEM BLY , BE SURE T O RELIEVE PRE SSURE FROM THE PIP ING SYSTEM AND , WHERE HAZARDOUS PRO CESS MATE RIALS ARE INV OLVED , RENDER T HE PUMP SAFE TO PERSONNE L AND THE E NVIRONMENT BY CLEANING AND CHEMIC ALLY NEUTRALIZING AS APPROPRI ATE . W EA ...

  • Honeywell DC5 - page 14

    10 7.2 Wet End Remo val, Inspecti on, & Reins tallation I F THE DI APHRAGM HAS F AILED , PROCESS F LUID M AY HAVE CONT AMINATED THE PUMP ECCENTRIC HOUSING ( ALTHOUGH NORM ALLY , ANY P ROCESS FLUID BEHIN D A FAILED DIAPHRAGM W OULD PASS THROUGH THE BOT TOM DRAIN HOLE ). H ANDLE W ITH APPROPRIATE CARE . Figure 8, wet end components OMNI ® diaphr ...

  • Honeywell DC5 - page 15

    11 7.2.1 Diaphragm Removal & Reinstallation 1. Adjust the stroke setting to 50% and disconnec t the power source to the dr ive motor. 2. Relieve all pressure from the piping system. 3. Close the inlet and outlet shutoff valv es. 4. Place a pan underneath the pump head adaptor to catch any liquid leakage. 5. Disconnect piping to the reag ent hea ...

  • Honeywell DC5 - page 16

    12 7.3 Check Val ves 7.3.1 General Description Most fluid metering proble ms are related to check v alves. Problems usually stem from solids accumulation between valve and sea t, corrosion of seating surfaces, e rosion, or physical dam age due to wear or the presence of foreign objects. The valve incorporates a ball, guide, and seat. Flow in the un ...

  • Honeywell DC5 - page 17

    13 Figure 10, check valves, DC3 and DC 4 Figure 11, check valves, DC5 and DC6 plastic construction Check Valve Suction Position Check Valve Suction Position Check Valve Discharge Position Check Valve Discharge Position ...

  • Honeywell DC5 - page 18

    14 7.3.2 Check Valve Removal & Reinstallation , Cartridge type Valving that is of the cartridge design is intended to be replaced as an assemb ly. 15. Disconnect the power source to the drive m otor. 16. Relieve all pressure from th e piping system. 17. Take all precautions necess ary to prevent contamination to the env ironment and personnel e ...

  • Honeywell DC5 - page 19

    15 Inserting the check valve assmbly into the pump in the wrong dir ectiom, or having the check seat upside down, will prevent proper seals at the o-rings, decrease pump p erformance, and can cau se damage to the diaphragm. 12. Carefully m ake sure that the check assemblies are in proper position, and tighten the four tie- bar bolts, using a star p ...

  • Honeywell DC5 - page 20

    16 7.4 Motor Rem o val & Reinstalla tion 1. Disconnect the power source to the drive m otor. 2. Disconnect the motor wiring from the motor. 3. Remove the four bolts retaining the m otor to the motor adaptor. The motor shaft fits into a b ore on the pump input shaft. 4. Slide the motor shaft out of the pump input s haft. Be careful not to lift t ...

  • Honeywell DC5 - page 21

    17 Figure 14, gearset components 7. Loosen the set screw (Item 9) on the worm gear (Item 8) and remov e it along with its shaft key (I tem 10). If you have the DC2 or 3 models go to step 8. I f you have the DC4, 5, or 6 m odels go to step 9. 8. Remove the Thrust Washers and Bearing (Item 11 & 12) from the housing. If the Thrust Washers show sig ...

  • Honeywell DC5 - page 22

    18 7.6 Gearset Re plac ement 1. Apply PULSA lube grease # NP980006- 000 to both sides of the thrust washer and install onto the eccentric shaft. On the DC4, 5, and 6 models, the washer fits into a shallow counter- bore. 2. Assemble Worm Gear (Item 8) and key (Item 10) to the eccentric shaf t. Do not tighten the setscrew yet. 3. Thread the M6-1.0 sc ...

  • Honeywell DC5 - page 23

    19 8. Replacement Parts 8.1 KOPkit Pr ogram OMNI ® KOPkits contain all replacement parts norm ally used in a preven tative maintenance program . ( PULSAlube grease is also available separately for prev entative maintenance program s. Refer to Section 6 – Equipment Sta rtup ). There is a specific KOPk it for every OMNI ® pump model. Each KOPkit ...

  • Honeywell DC5 - page 24

    20 8.3 KOPkit n umber s b y model: Pump Model Wet ted Material Connection Type KOPkit number D C 2 P V D F N P T N L K 0 2 0 F P D C 3 o r D C 4 P V D F N P T N L K 0 4 0 F P D C 3 o r D C 4 P V D F I S O 7 - 1 N L K 0 4 0 F B D C 5 o r D C 6 P V D F N P T N L K 0 5 0 F P D C 5 o r D C 6 P V D F I S O 7 - 1 N L K 0 5 0 F B D C 7 P V D F n / a N L K ...

  • Honeywell DC5 - page 25

    21 9. Model Number Identification Position Sample Specifies Option s 1 and 2 DC DC = OMNI m odel pum p 3 and 4 3B Size/Flow 2 / 3 / 4 / 5 / 6 – diaphra gm diam eter A / B / C / D – strok ing rate See s ales literature for flow/pressure ratings 5 X Motor fram e 1 – ½ Hp, 1 pH 11 5/230 V, 71 fram e and size 2 – ½ Hp, 1 pH, 1 15/230 V, 56 fr ...

  • Honeywell DC5 - page 26

    22 10. Wet End Materials Reference Wet End Configu ration Model Connection Head Gu ide Sealing O-rings Balls Seats Seat O- ring DC2 1/4" NPT DC3 DC4 1/2" NPT or ISO 7 -1 DC5 DC6 1" NPT or ISO 7-1 PTFE PVDF n/a PVDF (Kynar ® ) DC7 1 1/2" NPT & ANSI Flange and 1 1/2" DIN40 Flange PVDF PVDF Viton ® Ceram ic PVDF (o- ring ...

  • Honeywell DC5 - page 27

    23 11. Troubleshooting Difficulty Probable Cause Remedy Faulty power source. Check power source. Blown fuse, circuit breaker. Replace - eliminate overloa d. Broken wire. Locate and repair. Wired improperly. Check diagram. Pump does not start Process piping blockage. Open v alves, clear other obstruction s. Motor not running. Check power source. Che ...

  • Honeywell DC5 - page 28

    24 Difficulty Probable Cause Remedy Discharge pressure too high. Reduce pressure. Water hammer. Install pulsation dampener. Stroke length at partial setti ng. Some operating noise is characterist ic of lost motion pumps. Noisy gearing, knocking Low grease level. Add or replace grease. Pipe size too small. Increase size of piping - install pulsation ...

  • Honeywell DC5 - page 29

    25 12. Piping Accessories Pressure Relief Valves Pressure relief valves are designed to protect chemical feed sy stems from damag e that may be caused by defective equipment or a block age in the discharge line. These valves function to lim it the pressure downstream of the pump. Field adjust the pr essure relief valve to opera te when the discharg ...

  • Honeywell DC5 - page 30

    26 13. Dimensional Dra w ing Letters refe rence dimensiona l table on next page ...

  • Honeywell DC5 - page 31

    27 Dimens ion table in inc hes / m m Letter referenc es to d iagram , previous page “PP” = Pol ypropylene wetted m aterial “SS” = Stai nless steel wetted m aterial Dimens ions are with st andard IEC 71 B14 f ram e motor Dimension Model A B C D E DC2 1.0 / 25.4 0.7 / 18.0 6.9 / 175.3 4.5 / 113.5 1.5 / 38.1 DC3 1.0 / 25.4 0.7 / 18.0 6.9 / 175 ...

  • Honeywell DC5 - page 32

    28 14. Parts Diagrams and Parts Lists 14.1 Parts dia gram, DC2 and 3 ...

  • Honeywell DC5 - page 33

    29 14.2 Bill of Mater ials, DC2 ITEM DESCRIPTION QTY P ART NUMBER 1 SUPPORT PLATE 1 N P 1 4 0 0 5 4 - B R S 2 DIAPHRAGM 1 N P 1 7 0 0 3 0 - T H Y 3 REAGENT HEAD PVDF 1 N P 1 6 0 0 7 6 - P V D 3 REAGENT HEAD PVC (obsole te) 1 N P 1 6 0 0 5 4 - P V C 3 REAGENT HEAD 316 1 N P 1 6 0 0 5 4 - 3 1 6 4 BOLT 4 N P 9 9 0 4 2 0 - 1 8 8 5 FLT WASHER 4 N P 9 9 ...

  • Honeywell DC5 - page 34

    30 35 NAME TAG 1 N P 5 5 0 1 3 0 - 0 0 0 36 NAME TAG SCRE W 4 W 7 7 1 0 0 0 - 1 8 8 38 SET SCRE W 2 W 7 7 1 0 0 4 - 0 2 2 39 NEEDLE BEARING 1 N P 4 0 0 0 4 6 - 0 0 0 40 KEY-WORM GEAR 1 W 7 7 3 0 9 7 - 0 0 4 41 ECCENTRIC SPAC ER 1 N P 4 7 0 0 3 1 - 0 0 0 42 GASKET 1 N P 4 6 0 0 4 7 - 0 0 0 43 SCRE W 2 N P 9 9 0 0 0 8 - S T A 44 OIL SEAL 1 N P 4 5 0 ...

  • Honeywell DC5 - page 35

    31 14.3 Bill of Mater ials, DC3 ITEM DESCRIPTION QTY P ART NUMBER 1 SUPPORT PLATE 1 N P 1 4 0 0 5 5 - B R S 2 DIAPHRAGM 1 N P 1 7 0 0 3 1 - T H Y 3 REAGENT HEAD PVDF 1 N P 1 6 0 0 7 7 - P V D 3 REAGENT HEAD PVC (obsole te) 1 N P 1 6 0 0 5 5 - P V C 3 REAGENT HEAD 316 1 N P 1 6 0 0 5 5 - 3 1 6 4 BOLT 4 N P 9 9 0 4 3 6 - 1 8 8 5 FLT WASHER 4 N P 9 9 ...

  • Honeywell DC5 - page 36

    32 31 WASHER 1 W 7 7 1 0 0 6 - S T L 32 MOTOR ADAPT ASSY 56C 1 N P 4 9 0 0 3 0 - 0 0 0 32 MOTOR ADAPT A SSY 71 1 N P 4 9 0 0 2 9 - 0 0 0 33 W ORM SHAFT ASSY 56C 1 N P 0 6 0 0 3 1 - A 0 0 33 W ORM SHAFT ASSY IEC71 1 N P 0 6 0 0 3 1 - D 0 0 34 DC2/3 GEARBOX 1 N P 0 1 0 0 2 4 - A L U 35 NAME TAG 1 N P 5 5 0 1 3 0 - 0 0 0 36 NAME TAG SCRE W 4 W 7 7 1 0 ...

  • Honeywell DC5 - page 37

    33 This page intentionall y left BLANK ...

  • Honeywell DC5 - page 38

    34 14.4 Parts Dia gram, DC 4, 5, and 6 ...

  • Honeywell DC5 - page 39

    35 14.5 Bill of Mater ials, DC4 ITEM DESCRIPTION QTY P ART NUMBER 1 SUPPORT PLATE 1 N P 1 4 0 0 5 5 - B R S 2 DIAPHRAGM 1 N P 1 7 0 0 3 1 - T H Y 3 REAGENT HEAD PVDF 1 N P 1 6 0 0 7 7 - P V D 3 REAGENT HEAD PVC (obsole te) 1 N P 1 6 0 0 5 5 - P V C 3 REAGENT HEAD 316 1 N P 1 6 0 0 5 5 - 3 1 6 4 BOLT 4 N P 9 9 0 4 3 6 - 1 8 8 5 FLT WASHER 4 N P 9 9 ...

  • Honeywell DC5 - page 40

    36 30 LABEL 1 N P 5 5 0 0 8 4 - 0 0 0 31 WASHER 1 W 7 7 1 0 0 6 - S T L 32 MOTOR ADAPT ASSY 56C 1 N P 4 9 0 0 3 0 - 0 0 0 32 MOTOR ADAPT ASSY 71 1 N P 4 9 0 0 2 9 - 0 0 0 33 W ORM SHAFT ASSY 56C 1 N P 0 6 0 0 3 2 - A 0 0 33 W ORM SHAFT ASSY IEC71 1 N P 0 6 0 0 3 2 - B 0 0 34 DC4/5 GEARBOX 1 N P 0 1 0 0 2 3 - A L U 35 NAME TAG 1 N P 5 5 0 1 3 0 - 0 ...

  • Honeywell DC5 - page 41

    37 14.6 Bill of Mater ials, DC5 ITEM DESCRIPTION QTY P ART NUMBER 1 SUPPORT PLATE 1 N P 1 4 0 0 7 1 - B R S 2 DIAPHRAGM 1 N P 1 7 0 0 3 7 - T H Y 3 REAGENT HEAD PVDF 1 N P 1 6 0 0 2 2 - P V D 3 REAGENT HEAD PP 1 N P 1 6 0 0 2 2 - P P L 3 REAGENT HEAD PVC 1 N P 1 6 0 0 1 7 - P V C 3 REAGENT HEAD 316 1 N P 1 6 0 0 0 4 - 3 1 6 4 BOLT 6 N P 9 9 0 4 3 6 ...

  • Honeywell DC5 - page 42

    38 29 SCREW 1 W 7 7 1 0 0 1 - 0 1 0 30 LABEL 1 N P 5 5 0 0 8 4 - 0 0 0 31 WASHER 1 W 7 7 1 0 0 6 - S T L 32 MOTOR ADAPT ASSY 56C 1 N P 4 9 0 0 3 0 - 0 0 0 32 MOTOR ADAPT A SSY 71 1 N P 4 9 0 0 2 9 - 0 0 0 33 W ORM SHAFT ASSY 56C 1 N P 0 6 0 0 3 2 - A 0 0 33 W ORM SHAFT ASSY IEC71 1 N P 0 6 0 0 3 2 - B 0 0 34 DC4/5 GEARBOX 1 N P 0 1 0 0 2 3 - A L U ...

  • Honeywell DC5 - page 43

    39 14.7 Bill of Mater ials, DC6 ITEM DESCRIPTION QTY P ART NUMBER 1 SUPPORT PLATE 1 N P 1 4 0 0 8 1 - S T L 2 DIAPHRAGM 1 N P 1 7 0 0 3 9 - T H Y 3 REAGENT HEAD FPP 1 N P 1 6 0 0 2 3 - F P P 3 REAGENT HEAD PVDF 1 N P 1 6 0 0 2 3 - P V D 3 REAGENT HEAD 316 1 N P 1 6 0 0 3 1 - 3 1 6 4 BOLT 6 N P 9 9 0 4 7 7 - 1 8 8 5 FLT WASHER 6 N P 9 9 1 0 1 8 - 1 ...

  • Honeywell DC5 - page 44

    40 34 DC4/5/6 GEARBOX 1 N P 0 1 0 0 2 3 - A L U 35 NAME TAG 1 N P 5 5 0 1 3 0 - 0 0 0 36 NAME TAG SCRE W 4 W 7 7 1 0 0 0 - 1 8 8 38 SET SCREW 2 W 7 7 1 0 0 4 - 0 3 2 40 KEY-WORM GEAR 1 W 7 7 3 0 9 8 - 0 0 4 41 RETAINING RING 1 N P 9 9 9 0 3 2 - S T L 42 GASKET 1 N P 4 6 0 0 4 7 - 0 0 0 43 SCREW 2 N P 9 9 0 0 0 8 - S T A 44 OIL SEAL 1 N P 4 5 0 0 2 ...

  • Honeywell DC5 - page 45

    41 ...

  • Honeywell DC5 - page 46

    42 STANDARD PUMP O PERAT IONS 27101 Airport Road Punta Gord a, FL 33 982 (941) 575-38 00 Fax ( 941) 575-4085 Bullet in #: IOM- OM-1104- E www.pulsatro n.com R e v E ...

Fabricant Honeywell Catégorie Water Pump

Les documents que nous recevons du fabricant de l'appareilHoneywell DC5 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations DC5
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell DC5
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell DC5.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell DC5, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell DC5. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell DC5.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell DC5, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell DC5 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell DC5.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell DC5 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell DC5, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell DC5 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell DC5 - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell DC5
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell DC5
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell DC5 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell DC5?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell DC5, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell DC5 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)