    P ART NO. 63940 REV . B (06-09) WARNING: If the information in these instructions is not followed exactly , a fire or explosion may result causing property damage, per- sonal injury or death. WARNING: Improper inst allation, adjustment, alter- ation, service, or maintenance can cause injury or property damage. Refer to this manual. For assist ance ...

  • GSW 5065 - page 2

    This page intentionally lef t blank. May be used for notes or to record other installation information. – 2 – ...

  • GSW 5065 - page 3

    T ABLE OF CONTENTS I) Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Consumer Responsibilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . II) Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Co ...

  • GSW 5065 - page 4

    Thank you for purchasing a Flammable V apour Ignition Resist ant Power V ented Water Heater . This water heater is designed to reduce the risk of flammable vapour related fires by shutting the burner down before flammable vapours get into the water heater combustion chamber . This is achieved by the means of the flammable vapour sensor . Properly i ...

  • GSW 5065 - page 5

    This water heater is design-certified by CSA International as a Category I, non-direct vented water heater which takes it s combustion air either from the installation area or from air ducted to the unit from the outside. In addition to the installation instructions found in this man- ual, the water heater must be installed in accordance with all l ...

  • GSW 5065 - page 6

    R elief V alve R equirements (T&P) All water heaters must be fitted with a proper temperature and pressure relief valve. These valves must be certified as meeting the requirements of the “ S tandard For Relief V alves For Hot Water Supply Systems, ANSI Z21.22/CSA 4.4” . If this water heater has been exposed to flooding, freezing, fire or an ...

  • GSW 5065 - page 7

    to the area adjacent to the water heater or to lower floors of the structure (see “IMPORT ANT” notice on the previous page). Before inst alling this water heater , consideration and planning must be given to the following details: • Proximity to walls and other objects (see “Clearance and Accessibility”). • Access to gas supply (see “ ...

  • GSW 5065 - page 8

    This gas piping must be installed in accordance with all local and provincial or state codes or , in the absence of such, the latest edition of “Natural Gas and Prop ane Installation Code” CAN/CSA-B149.1 (Canada), or “National Fuel Gas Code” ANSI Z223.1 (NFP A 54) (U.S.A.). Note: When installing gas piping, apply sealing compounds approved ...

  • GSW 5065 - page 9

    Air R equirements Import ant: Air for combustion and ventilation must not come from a corrosive atmosphere. Any failure due to cor- rosive elements in the atmosphere is excluded from war- ranty coverage. Installations in or for cert ain places including, but not limited to, those listed below will require outdoor air for combustion due to chemical ...

  • GSW 5065 - page 10

    Confined Space Air R equirements for U .S. Installa tions Refer to Figure 5 (a), (b), (c) or (d) for proper sizing and location of combustion air ducts and openings. CHECK LOCAL CODES . (a) Equipment located in confined spaces; all air from inside the building. T wo permanent openings shall be provided connecting the confined space (e.g., closet, s ...

  • GSW 5065 - page 11

    V enting This water heater has a power vent system that discharges all it's combustion products out doors. The heater must be properly vented for removal of exhaust gases. Correct installation of the vent pipe system is mandatory for the safe and efficient operation of this water heater and is an impor- tant factor in the life of the unit. V e ...

  • GSW 5065 - page 12

    Horizontal V ent T er minal Installations The following requirements are illustrated in Figure 10: 1. ("A") Minimum 2.1m (7 ft.) above a p aved sidewalk or paved driveway that is located on public property . 2. ("B") Minimum 900mm (3 ft.) above any forced air or mechanical air supply inlet located within 1.8m (6 ft.) horizontall ...

  • GSW 5065 - page 13

    2. Must provide proper support for all pipes protruding through roof. 3. The vertical roof terminations should be sealed with a plumbing roof boot or equivalent flashing. The specifications are displayed in Figure 1 1. V ent Pipe Installation Refer to T able 2 for maximum and minimum vent length. Plan the vent system layout so that proper clearance ...

  • GSW 5065 - page 14

    V ent Pipe Runs All Power V ented water heaters generate a certain amount of operational noise. In order to minimize noise transmission to floor joists though hangers, place some sof t material such as foam rubber , approximately 12mm (1/2 in.) thick, between hangers and the vent pipes. 1. Horizontal runs must not, under any circumst ances, run dow ...

  • GSW 5065 - page 15

    4. T ighten the upper gear clamp to ensure the vent pipe is firmly secured and gas tight. 5. Check that the lower gear clamp is firmly seated, secured and gas tight. 6. As a final check, the vent pipe should be gently moved side to side and vertically . There should be no slipp age or movement of the vent pipe within the coupling. 7. Seal around th ...

  • GSW 5065 - page 16

    5. Install a shut-of f valve in the cold water inlet line. It should be located close to the water heater and be eas- ily accessible. The owner/operator must be shown the location of this valve and be given instructions on how to use it to shut off the water to the heater . Filling the Wa ter Heater Do not insert the power cord into the electrical ...

  • GSW 5065 - page 17

    in the water heater . The valve’s relief pressure must not exceed the working pressure of the water heater as stated on the data plate. Import ant: Only a new temperature and pressure relief valve should be used with your water heater . Do not use an old or existing valve as it may be damaged or not adequate for the working pressure of the new wa ...

  • GSW 5065 - page 18

    AIR PRESSURE SWITCH BLOWER GND L1 N IGNITER FLAME SENSOR GAS V AL VE SOLENOID POLARITY SENSITIVE DO NOT MIS- MA TCH WIRING! FAILURE TO CONNECT CORRECTL Y WILL PREVENT THE UNIT FROM FUNCTIONING PROPERL Y . FLAMMABLE V APOUR SENSOR CONNECTOR HIGH LIMIT SWITCH Figure 22 Robertshaw Wiring Diagram - Control Figure 23 Gas Control/Thermostat Details (Robe ...

  • GSW 5065 - page 19

    Installation Chec klist Check Here Wa ter Heater Loca tion 1. Centrally located with the water piping system. Located as close to gas piping and vent pipe system as possible. 2. Located indoors and in a vertical position. Protected from freezing temperatures. 3. Proper clearances from combustible surfaces maintained and not inst alled directly on a ...

  • GSW 5065 - page 20

    FOR YOUR SAFETY READ BEFORE OPERA TING POUR VOTRE SÉCURITÉ, LISEZ A V ANT DE METTRE EN MARCHE OPERA TING INSTRUCTIONS INSTRUCTIONS DE MISE EN MARCHE TO TURN OFF GAS T O APPLIANCE COMMENT COUPER L'ADMISSION DE GAZ DE L'APP AREIL W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property da ...

  • GSW 5065 - page 21

    Fir st Lighting This appliance is equipped with an ignition device, which automatically lights the pilot. Do not try to light manually with a match. The temperature dial is adjusted to it s lowest tempera- ture position when shipped from factory . Gas Control/T her mostat This heater is equipped with a Robertshaw 2000WDER combination gas control/th ...

  • GSW 5065 - page 22

    Impor tant: When using a leak test solution around the control, do not splash any liquid on the flammable vapour sensor , electric connections or electronic components of the gas control/thermostat. The gas control/thermostat can be damaged. DO NOT use a flame to detect gas leaks. 7. T urn the temperature dial to the lowest setting. The burner will ...

  • GSW 5065 - page 23

    Wa ter Hea ter Oper a tion Figure 24 shows the water heater ’ s sequence of operation when a call for heat is initiated. The ignition control module will attempt to light the burner three times. If the ignition con- trol does not detect ignition it will enter lockout mode, indi- cated by a three flash error code. Bur ner Flames Inspect the burner ...

  • GSW 5065 - page 24

    complaint associated with the anode rod is a “rotten egg smell” produced from the presence of hydrogen sulfide gas dissolved in the water . Do not remove this rod perma- nently as it will void any warranties, st ated or implied. A special anode can be ordered if water odour or discoloura- tion occurs. This rod may reduce, if not eliminate, wate ...

  • GSW 5065 - page 25

    T emperature and Pr essure Relief V alv e Manually operate the temperature and pressure relief valve at least once a year to make sure it is working properly (see Figure 27). T o prevent water damage, the valve must be properly connected to a discharge line that terminates at an adequate drain. S t anding clear of the outlet (discharged water may b ...

  • GSW 5065 - page 26

    Installation The heating mode may be one of the following options: A. A fan coil/air handler (Figure 28). B. A hydronic baseboard (finned tube) loop/In floor heating (Figure 29). The following is a list of requirements for the inst allation of the heating loop to the water heater . 1. Install shut-of f valves and unions so that the water heater can ...

  • GSW 5065 - page 27

    VIII) TROUBLESHOO TING GUIDE (Rober tshaw 2000WDER) SYMPT OM POSSIBLE CA USE(S) CORRECTIVE ACTION BLOWER WILL NOT ST ART . 1. No Power to unit. 2. Thermostat setting too low . 3. Defective air pressure switch (must be open at start-up before blower is ener- gized). 4. Defective blower . 5. Disconnected or loose wire. 6. Control locked-out. 1. Plug ...

  • GSW 5065 - page 28

    IX) P ARTS REFERENCE ILL USTRA TION 17 16 14 15 13 12 10 11 9 8 7 6 1 3 2 26 25 23 24 22 21 20 19 18 5 4 31 6 27 28 29 30 1. V ent T ermination Elbow with Rodent Screen 2. **V ent Pipe 3. **V ent Pipe Coupling (if required) 4. **V ent Pipe Elbow (long radius) 5. Limit Switch 6. T&P V alve 7. Diptube 8. Baffle Assembly 9. Driptube 10. Gas Contro ...

  • GSW 5065 - page 29

    See Rating Label Serial Number prefix for W arranty Code. Reduced warranty period applies to Newfoundland. W arranty Code: P R S T U V W Y S tandard W arranty Y ears: 3 5 6 7 8 9 10 12 Reduced W arranty Y ears: 2 3 3 555 5 7 ~ Certificate of W arranty ~ For its GSW and John W ood water heaters and storage boosters ("Unit"), GSW W ater Hea ...

Fabricant GSW Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilGSW 5065 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques GSW
- manuels d’utilisations 5065
- fiches produit GSW
- dépliants
- ou étiquettes-énergie GSW 5065
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation GSW 5065.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation GSW 5065, manuels d’entretien, brefs manuels ou manuels de l’utilisateur GSW 5065. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit GSW 5065.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil GSW 5065, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser GSW 5065 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs GSW 5065.

Le manuel d’utilisation complet GSW, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel GSW 5065 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières GSW 5065, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGSW 5065 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil GSW 5065 - qui devraient nous aider dans les premières étapes lors de l'utilisation GSW 5065
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de GSW 5065
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service GSW 5065 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de GSW 5065?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec GSW 5065, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec GSW 5065 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)