Manuel d’utilisation Emerson CMF200A

26 pages 1.43 mb
Télécharger

Aller à la page of 26

Summary
  • Emerson CMF200A - page 1

    Micro Motion ® ELITE ® Sensors Inst allation Manual Inst allation Manual P/N 20002158, Rev . C September 20 07 ...

  • Emerson CMF200A - page 2

    ©2007, Micro Motion, Inc. All rights rese rved. ELITE and Pr oLi nk are registered trademarks, and MVD and MVD Direct Co nnect are trademarks of Micro Motion, Inc., Boulder , Colorado. Micro Mo t ion is a registered tr ade name of Mi cro Motion, Inc ., Boulder , Colorado. The Mi cro Motion and Emerson logos are t rademarks and service marks of Eme ...

  • Emerson CMF200A - page 3

    Installati on Manual 1 Before Y ou Begin Before Y ou Begin This manual describes ho w to install a Micro Motion ® ELITE ® sensor . The follo wing information is provided in this manual: Customer service For technical assistance, phone the Micr o Motion Customer Service depa rtment: • In the U.S.A., phone 800-522-MASS (800-522-6277) (toll free) ...

  • Emerson CMF200A - page 4

    2 Micro Motion ® ELITE ® Sensors Before Y ou Begin Specifications Full product specif ications can b e found in the pro duct data sheet, which is a va ilable from the Micro Motion web site at www .micromotion.com . Definitions The term MVD ™ transmitt er refers to the follo wing transmitter models: • Models 1500, 1700, 240 0S, 2500, and 27 00 ...

  • Emerson CMF200A - page 5

    Installation Manua l 3 Before Y ou Begin Figure 1 ELITE sensor with Model 2400S tran smitter or enhanced core processor Flow direction arrow Purge fittings or rupture disks (optional) Calibration tag Thru holes for alternative mounting Process connection CMF010 Approv al tag Model 2400S transmitter or enhanced core processor Model 2400S transmitter ...

  • Emerson CMF200A - page 6

    4 Micro Motion ® ELITE ® Sensors Before Y ou Begin Figure 2 ELITE sensor with core p rocessor Flow direction arrow Purge fittings or rupture disks (optional) Calibration tag Core processor housing Thru holes for alternative mounting Process connection CMF010 CMF025, CMF050, or CMF100 Purge connections (optional) CMF200, CMF300, CMF400, or CMFHC3 ...

  • Emerson CMF200A - page 7

    Installation Manua l 5 Before Y ou Begin Figure 3 ELITE sensor with j unction box Flow direction arrow Purge connections or rupture disks (optional) Calibration tag Junction bo x Approv al tag Thru holes f or alternative mounting Process connection Junction bo x Approv al tag CMF025, CMF050, or CMF100 Flow direction arro w Process connection Purge ...

  • Emerson CMF200A - page 8

    6 Micro Motion ® ELITE ® Sensors Determining a Location Figure 4 High-temperature or extre me high-temperature ELITE sensor Step 1 Determining a Location Choose a location for the sensor based on the requirements descri bed in th is section. The foll o wing general guidelines can help you select an appropriate location fo r the sensor . Full flow ...

  • Emerson CMF200A - page 9

    Installati on Manual 7 Determining a Locati on Figure 5 ELITE sensor ambie nt and proces s temperature limits (all models except high-temperature and e xtreme high-temperature mo dels) Ambient temperature of core processor or transmitter in °F (°C) Maximum process temperature in °F (°C) Mount transmitter remotely; use junction box –148 (–10 ...

  • Emerson CMF200A - page 10

    8 Micro Motion ® ELITE ® Sensors Determining a Location Figure 6 High-temperature and extre me high-temperature ELITE sensor ambient an d process tem perature limits Hazardous area approv als may impose additional limits on ambient and pr ocess temperature. For the A TEX “T” rating, refer to the A TEX documentation shipped with the sensor or ...

  • Emerson CMF200A - page 11

    Installation Manua l 9 Determining a Locati on Maximum wiring distances If the transmitter is mounted remote ly from the sensor , the maximum di stance between the sensor and transmitter depends on cable type. See T able 2. For high-temperat ure and extreme high-tempe rature ELITE sensors, note the f ollo wing: • For sensors with a Model 1700/270 ...

  • Emerson CMF200A - page 12

    10 Micro Motion ® ELITE ® Sensors Orientin g the Se nsor Step 2 Orienting the Sensor The sensor will function prop erly in an y orientation if the sensor tubes remain filled with process fluid. Micro Motion reco mmends orientin g ELITE sensors as sho wn in T able 3. Flow direction arrow The sensor has a flo w direction arrow (see Figures 1–4) t ...

  • Emerson CMF200A - page 13

    Installation Manua l 11 Mounting the Se nsor Step 3 Mounting the Sensor Use your common practices to minimize torque and bendi ng load on process conn ections. Figure 7 illustrates ho w to mount the sensor . T o reduce the risk of co ndensation or excessi ve mois ture, the cond uit opening should not point up ward (if possible). The conduit opening ...

  • Emerson CMF200A - page 14

    12 Micro Motion ® ELITE ® Sensors Mounting the Sensor Installing extended mount electronics If you ordered a sensor with an e xte nded mount for the electronics, you will need to install the e xtender . T o install the e xtended mount electronics: 1. There is a metal clamping ring around the base of the feedthrough (Figure 9). Remov e this ring a ...

  • Emerson CMF200A - page 15

    Installation Manua l 13 Mounting the Se nsor Figure 10 Mounting the temperature e xtender onto the sensor Mounting the electronics of high-temperature and e xtreme high-temperature se nsors High-temperature and extreme high-tem perature ELITE sensors come with a 32 ″ (812 mm) pre-installed flexible conduit. This conduit is required for agency app ...

  • Emerson CMF200A - page 16

    14 Micro Motion ® ELITE ® Sensors Mounting the Sensor Figure 11 Electronics mounting for h igh-temperature and extreme high-tempera ture ELITE sensors Installing wafer -style sensors A wafer -style sensor , which has no flanges or f ittin gs, lets you “clamp” the sensor between process connections in the pipeline. Model CMF025, CMF050, and CM ...

  • Emerson CMF200A - page 17

    Installation Manua l 15 Mounting the Se nsor Figure 12 Wafer -style assembly Figure 13 Tightening the sensor alignment rin gs Process connection Sensor waf er Flange bolt Alignment ring Gasket (user-supplied) Flange nut Rotate the ring... ...to push the bolts outward Sensor waf er Sensor alignment ring Flange bolt ...

  • Emerson CMF200A - page 18

    16 Micro Motion ® ELITE ® Sensors Wiring Step 4 Wiring Hazardous area installations If you are installing the sensor in a hazardous location, verify that the hazardous classif ication information printed on the sensor tag matches the en viro nment in which the sensor will be installed. Improperly sealed housings can expose electron ics to moistur ...

  • Emerson CMF200A - page 19

    Installation Manua l 17 Wiring Figure 14 Micro Motion cable gland an d heat shrink 4. Fo r connection at the core p rocessor housing, pr epare shielded cable as follows (for armored cable, omit steps d, e, f, and g): a. Strip 4 1/2 inch es (114 mm) o f cable jack et. b . Remov e the clear wrap that is inside the cable jack et, and remov e the fille ...

  • Emerson CMF200A - page 20

    18 Micro Motion ® ELITE ® Sensors Wiring Figure 16 Applying the heat shrink g. Position gland clamping inse rt so the interior end is flush with the heat shrink. h. Fold the cl oth shield or braid and drain wires o ver the clampin g insert and approximately 1/8 inch (3 mm) past the O-ring. Figure 17 Folding the cloth shield i. Install the gland b ...

  • Emerson CMF200A - page 21

    Installation Manua l 19 Wiring Figure 19 Connecting the wires at the core processor 7. Reinstall and tighten the co re processor housing co ver . 8. Additional wiring instructions for the tran smitter can be found in the t ransmitter manual. Note: Never gr ound the 4-w ir e cable shield an d shield drain wir e(s) at the transmit ter . Junction box ...

  • Emerson CMF200A - page 22

    20 Micro Motion ® ELITE ® Sensors Grounding Step 5 Grounding The sensor can be groun ded via the piping if the joints in the pipeline are ground- bonded. If the sen sor is not grounded via the piping, con nect a ground wire to the in ternal or exter nal grounding scre w , which is located on the transmitter , core processor , or junction box. Imp ...

  • Emerson CMF200A - page 23

    Installation Manua l 21 Purge Fittings Purge Fittings If the sensor has pur ge fittings, the y should remain seal ed at all times. After a purge plug has been remo ved, the sensor case should b e purged w ith ar gon or nitrogen and resealed. Purging the case protects internal components. The sensor is purged of all oxygen and sealed at the factory ...

  • Emerson CMF200A - page 24

    22 Micro Motion ® ELITE ® Sensors Rupture Disks Rupture Disks If the sensor has rupture disks, the y are installed in the sensor purge f itting openin gs. The rupture disks should remain installed at all times. If you remov e a rupture disk from the se nsor case, it will be necessary to re-pur ge the case (see Case pur ging pr ocedur e on page 21 ...

  • Emerson CMF200A - page 25

    Installation Manua l 23 Return Policy Return Policy Micro Motion procedu res must be followed when retu rning equipment. These procedures ensure le gal compliance with go vernment transpor tation agencies and help pro vide a safe working en vironment for Micro Motion employees. F ailure to follo w Micro Motion proced ures will result in your equipm ...

  • Emerson CMF200A - page 26

    Micro Motion Inc. USA Worldwide Headqu arters 7070 Winchester Circle Boulder , Colorado 80301 T +1 303-527-5200 +1 800-522-6277 F +1 303-530-8459 Micro Motion Europe Emerson Process Management Neonstraat 1 6718 WX Ede The Netherlands T +31 (0) 318 495 555 F +31 (0) 318 495 556 Micro Motion Japan Emerson Process Management 1-2-5, Higashi Shinagawa S ...

Fabricant Emerson Catégorie Stud Sensor

Les documents que nous recevons du fabricant de l'appareilEmerson CMF200A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Emerson
- manuels d’utilisations CMF200A
- fiches produit Emerson
- dépliants
- ou étiquettes-énergie Emerson CMF200A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Emerson CMF200A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Emerson CMF200A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Emerson CMF200A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Emerson CMF200A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Emerson CMF200A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Emerson CMF200A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Emerson CMF200A.

Le manuel d’utilisation complet Emerson, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Emerson CMF200A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Emerson CMF200A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmerson CMF200A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Emerson CMF200A - qui devraient nous aider dans les premières étapes lors de l'utilisation Emerson CMF200A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Emerson CMF200A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Emerson CMF200A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Emerson CMF200A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Emerson CMF200A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Emerson CMF200A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image