    0910 Form # AM-328-04 Part # 63543 GRINDMASTER CORPORA TION ™ Liquid Cof fee Dispenser Operation and Instruction Manual for LCD-2A (Ambient Cabinet) & LCD-2R (Refrigerated Cabinet) © Grindmaster Corporation, 2009 Printed in USA T ABLE OF C ONTENTS Prior authorization must be obtained from Grindmaster Corporation for all warranty claims. Intr ...

  • Grindmaster LCD-2A - page 2

    Page 2 Model LCD-2R and LCD-2A Introduction The Grindmaster-Cecilware Liquid Coffee Dispensers (LCD-2A) and the Liquid Coffee Chilled Dispenser (LCD-2R) deliver two types of coffee made from liquid concentrate plus hot water . • The dispenser can be set up for continuous draw (by the cup) for self-serve applications, or portion-control to fill ca ...

  • Grindmaster LCD-2A - page 3

    Page 3 Model LCD-2R and LCD-2A User Replaceable Part s      !"#$%& '($) * ) ...

  • Grindmaster LCD-2A - page 4

    Page 4 Model LCD-2R and LCD-2A W arning Labels The following warning labels were on your dispenser when it was shipped from the factory . They should remain on your dispenser in good, readable condition at all times. If one of your labels is missing or damaged, order a replace- ment label immediately . Part #62981, Located on lower splash panel on ...

  • Grindmaster LCD-2A - page 5

    Page 5 Model LCD-2R and LCD-2A Inst allation W ater Inlet Connection: The National Sanitation Foundation requires the following for an NSF approved water hook-up: 1. A quick disconnect water connection or enough coiled tubing so that the machine can be moved for cleaning underneath. 2. An approved backflow prevention device, such as a double check ...

  • Grindmaster LCD-2A - page 6

    Page 6 Model LCD-2R and LCD-2A Inst allation (cont.) Electrical Hook-up: Ensure water connection is made to machine before proceeding and water source is turned ON. The electrical ratings for your dispenser are located on the serial plate on the outside cabinet. For configuration of heater to optional wattages, refer to configuration decal 50524-04 ...

  • Grindmaster LCD-2A - page 7

    Page 7 Model LCD-2R and LCD-2A 9. Af ter the water tank has completed the fill cycle, the display located on the front door of the dispenser should indicate that the heating element has been activated. Allow 10-60 minutes for the water tank to reach operating temperature. (Note: Heatup time is dependent on water inlet temperature and input wattage ...

  • Grindmaster LCD-2A - page 8

    Page 8 Model LCD-2R and LCD-2A Open the door and insert Setup key into keyswitch above cooler compartment. T urn key ¼ turn clock- wise, the display on front of door will say ‘Setup Mode, Press Enter ’. The two ‘Prime’ buttons and the Flush button now become the programming buttons: Prime 1 = UP , Prime 2 = DOWN, Flush = ENTER Press the En ...

  • Grindmaster LCD-2A - page 9

    Page 9 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode T o access engineer mode go into Setup mode, when the screen says ‘Setup Mode, Press Enter ’ press the Hot W ater tap – the display will now say ‘Engineer Mode, Press Enter’. The engineer has access to the f ...

  • Grindmaster LCD-2A - page 10

    Page 10 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Engineer Mode (cont.) No prod, Stop Sel [Disabled]: No product, stop Selection. If enabled, when the cof fee goes low during a dispense it will stop, giving a low measure. If disabled it will continue with the dispense even if the ...

  • Grindmaster LCD-2A - page 11

    Page 11 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Machine Fault Codes (cont.) 6: W ater overheat The thermistor has detected the water is too hot. The boiler element cont actor may have failed short circuit. The machine may be running high W attage Power with a preheater . 7: Lea ...

  • Grindmaster LCD-2A - page 12

    Page 12 Model LCD-2R and LCD-2A T o check water flow rate and calibrate the actual mix ratio adjustment to match the programming mix ratio: “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.) IMPORT ANT NOTE REGARDING PORTION OVERRIDE BUTTON: The default time ...

  • Grindmaster LCD-2A - page 13

    Page 13 Model LCD-2R and LCD-2A “Engineer” Program Settings TO BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN ONL Y Programming Guide for Calibration of Mix Ratio (cont.) Worksheet Dispensed W ater 1. _____________ ml 2. _____________ ml 3. _____________ ml Average: _____________ ml W ater Flow Rate = Average ml / Override Portion T ime = ml/se ...

  • Grindmaster LCD-2A - page 14

    Page 14 Model LCD-2R and LCD-2A W eekly Cleaning Instructions refer to Figure E NOTE: Some bag-in-box connectors require some disassembly for cleaning and sanitizing NOTE: Some bag-in-box connectors requires some extra steps for cleaning and sanitizing. 1. Remove fitting cap (a) from bag-in-box quick disconnect fitting if applicable. 2. Then, if eq ...

  • Grindmaster LCD-2A - page 15

    Page 15 Model LCD-2R and LCD-2A Service and Cleaning Draining the T ank Always empty the tank before shipping. 1. Prep are a minimum 5 gallon (17.5 litre) heat resistant cont ainer to drain the tank water into. 2. Unplug the machine. 3. Remove the drain tray and front access p anel. 4. Locate the silicone drain hose. Put the end of the drain hose i ...

  • Grindmaster LCD-2A - page 16

    Page 16 Model LCD-2R and LCD-2A T roubleshooting Guide A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problem encountered. If the problem remains af ter exhausting the troubleshooting steps, cont act Grindmaster- Cecilware T echnical Service Department (800-695-4500, 8am-6pm, M-F). • Only qualified ...

  • Grindmaster LCD-2A - page 17

    Page 17 Model LCD-2R and LCD-2A T roubleshooting Guide (cont.)  W ARNING: Risk of electrical shock. Disconnect power before removal of any machine access p anels. Problem/Cause Remedy MACHINE DOES NOT POWER UP Machine is unplugged Ensure machine is plugged into power supply Power switch in OFF position Flip power switch to “ON” position (loc ...

  • Grindmaster LCD-2A - page 18

    Page 18 Model LCD-2R and LCD-2A Problem/Cause Remedy LCD DISPLA Y INDICA TES “OVERFLOW” NOTE: Water must be drained from the tank below the float switch af ter the fault condition is diagnosed. W ater level probe sensitivity is set too low Increase sensitivity of water fill circuit (see programming notes: W ater Level T rip) Faulty or corroded ...

  • Grindmaster LCD-2A - page 19

    *5((1< *5< 5(' *5< 5(' %/. &RQQHFWWR/DVVKRZQIRUYROWZDWW PLQLPXP$:*FRUGDJHRU &RQQHFW/WR1HXWUDOIRUYROWZDWW PLQLPXP$:*FRUGDJH :+7 *5< 'LVSHQVH GLVDEOH VZ ...

  • Grindmaster LCD-2A - page 20

    Grindmaster® Coffee Grinders and Br ewers • PrecisionBr ew™ Brewing Systems • Espressimo® Espr esso Machines Crathco® Hot Beverage Dispensers • Crathco® Cold and Frozen Beverage Dispensers • AMW Cof fee and T ea Systems T el (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 (USA & Canada only) P .O. Box 35020 • Louisville ...

Fabricant Grindmaster Catégorie Coffeemaker

Les documents que nous recevons du fabricant de l'appareilGrindmaster LCD-2A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Grindmaster
- manuels d’utilisations LCD-2A
- fiches produit Grindmaster
- dépliants
- ou étiquettes-énergie Grindmaster LCD-2A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Grindmaster LCD-2A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Grindmaster LCD-2A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Grindmaster LCD-2A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Grindmaster LCD-2A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Grindmaster LCD-2A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Grindmaster LCD-2A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Grindmaster LCD-2A.

Le manuel d’utilisation complet Grindmaster, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Grindmaster LCD-2A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Grindmaster LCD-2A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGrindmaster LCD-2A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Grindmaster LCD-2A - qui devraient nous aider dans les premières étapes lors de l'utilisation Grindmaster LCD-2A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Grindmaster LCD-2A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Grindmaster LCD-2A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Grindmaster LCD-2A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Grindmaster LCD-2A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Grindmaster LCD-2A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)