Manuel d’utilisation United States Stove 4027

20 pages 0.33 mb
Télécharger

Aller à la page of 20

Summary
  • United States Stove 4027 - page 1

    USSC 1 CAUTION: READ ALL INSTRUCTIONS CARE- FULLY BEFORE STARTING THE INSTALLATION OR OPERATING THE HEATER IMPROPER INSTALLATION MAY VOID YOUR WARRANTY DO NOT USE THIS HEATER IN A MOBILE HOME OR TRAILER 851523 C R US UNITED STATES STOVE COMPANY 227 Industrial Park Road P.O.Box 151 South Pittsburg, TN 37380 (423) 837-2100 Owner’s Manual 4027 & ...

  • United States Stove 4027 - page 2

    2 USSC SAFETY PRECAUTIONS PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW HEATING APPLIANCE. FAIL- URE TO FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. THIS HEATING APPLIANCE SHOULD BE INSTALLED ONLY BY AN EXPERIENCED COAL HEATER INSTALLER. IF THIS HEATING APPLIANCE IS NOT PROPERLY INSTALLED, A ...

  • United States Stove 4027 - page 3

    USSC 3 Before Assembly, inspect the heater thoroghly for missing parts or shipping damage. If any damage or missing parts are detected, report it to your heater dealer. DO NOT INSTALL OR USE A DAMAGED OR INCOMPLETE HEATER Shaker Handle Assembly: 1. First, remove the two(2) bolts from the left side of the unit where the shaker handle is to be mounte ...

  • United States Stove 4027 - page 4

    4 USSC FIGURE 1 - MASONRY CHIMNEY REQUIREMENTS FLUE MINIMUM 1/2" AIR SPACE FOUNDATION CHIMNEY WALL 4" NOMINAL 5/8" FIRECLAY OR STAINLESS STEAL FLUE LINER If the heater is to be connected to a masonry chimney, the heater should not be installed until it is determined that the chimney is safe for use. Before installing the heater, have ...

  • United States Stove 4027 - page 5

    USSC 5 FIGURE 4- CHIMNEY HEIGHT REQUIREMENTS A Chimney must be the required height above the roof or other obstruction for safety and for proper draft op- eration. The requirement is that the chimney must be at least 3 feet higher than the highest point where it passes through the roof and at least 2 feet higher than the high- est part of the roof ...

  • United States Stove 4027 - page 6

    6 USSC Figure 5 shows how to connect the chimney connector of a heater to a masonry chimney through a combustible wall. There are five allowable ways that a chimney connector can be connected to a masonry chimney by passing through a combustible wall. NFPA Standard 211 allows the following wall pass-through systems. MASONRY CHIMNEY CONSTRUCTED TO N ...

  • United States Stove 4027 - page 7

    USSC 7 CHIMNEY FLUE MINIMUM CHIMNEY CLEARANCE TO BRICK AND COMBUSTIBLES IS 2 IN. MINIMUM CLEARANCES 12 IN. OF BRICK ALL AROUND CHINEY CONNECTOR TO HEATER FIRE CLAY LINER (5/8" MIN. WALL THICKNESS) MIN. 3-1/2" THICK BRICK MASONRY WALL MASONRY CHIMNEY CONSTRUCTED TO NFPA 211 MINIMUM 12 IN. TO COMBUSTIBLES PART A, FIGURE 5 (FIGURE 5 CONTIUED ...

  • United States Stove 4027 - page 8

    8 USSC PART E - (Figure 5) In addition to the methods shown by A, B, C, and D of Figure 5, a listed factory-built wall pass-through system may be purchased and installed according to the instructions packaged with it to provide a safe method of passing chimney connector through a combustible wall for a connection to a masonry chimney. If the chimne ...

  • United States Stove 4027 - page 9

    USSC 9 METAL PREFABRICATED CHIMNEY REQUIREMENTS Any metal prefabricated chimney that this heater is connected to must be a Listed High Temperature Type 103-HT Factory- Built Residential Type and Building Heating Appliance Chimney. Its interior size should be no smaller than 6 inches in diameter or no larger than 8 inches in diameter. An undersized ...

  • United States Stove 4027 - page 10

    10 USSC COMBUSTIBLE CEILING JOIST SPECIFIED CLEARANCE INSULATION SHEILD LISTED CHIMNEY TO HEATER CEILING SUPPORT CHIMNEY CONNECTOR ROOF FLASHING STORM COLLAR CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.) MAINTAIN 2 INCH CLEARANCE LISTED CHIMNEY CEILING CEILING SUPPORT CHIMNEY CONNECTOR TO HEATER WALL FLOOR PROTECTOR FIGURE ...

  • United States Stove 4027 - page 11

    USSC 11 SECTION LISTED CHIMNEY PIPE TO HEATER TRIM COLLAR ON INSIDE WALL CHIMNEY CONNECTOR LISTED CHIMNEY INSULATED "T" WALL SUPPORT WALL SPACER ON OUTSIDE WALL 2" CLEARANCE (BETWEEN WALL AND CHIMNEY) COMBUSTIBLE OUTSIDE WALL CHIMNEY CAP (WITH SPARK ARRESTER IF DESIRED OR WHERE REQUIRED BY LAW.) ROOF FLASHING STORM COLLAR MAINTAIN 2 ...

  • United States Stove 4027 - page 12

    12 USSC HEATER INSTALLATION CAUTION: FOR YOUR SAFETY, THE INSTALLATION OF THIS HEATER MUST COMPLY WITH LOCAL CODES AND REGULATIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSPECTION TO ASSURE PROPER COMPLIANCE WITH LOCAL CODES AND REGULATIONS. MINIMUM CLEARANCES TO COMBUSTIBLE WALL AND CEILINGS CAUTION: MOST WALLS AND CEILINGS CONTAIN WOOD ...

  • United States Stove 4027 - page 13

    USSC 13 FIGURE 9 - PLAN VIEWS SHOWING FLOOR PROTECTOR'S MINIMUM SIZE (DIMENSIONS IN INCHES) Masonry, or other non-combustible products, attached directly to a combustible surface without an air space offer very little protection and cannot be considered a clearance reducer unless specified materials have been tested and listed for direct attac ...

  • United States Stove 4027 - page 14

    14 USSC 6. Place the crimped end of the first chimney pipe or elbow into the heater's flue collar and mark it through each of the holes in the heater's flue collar. 7. Remove the pipe or elbow from the flue collar and drill 1/8 - inch diameter holes at the points marked. 8. Apply the furnace to the inside surface of the heater's flue ...

  • United States Stove 4027 - page 15

    USSC 15 OPERATING INSTRUCTIONS Burning Coal in your 4027/ASA7 Your Wondercoal is capable of burning both bituminous and Anthracite coal. Anthracite is the best coal fuel because its long even burn time, high heat output, and cleanliness make it a good choice for the home. However, keep in mind it is a much more difficult fuel to use and requires mo ...

  • United States Stove 4027 - page 16

    16 USSC CAUTION! ASHES SHOULD NEVER BE ALLOWED TO ACCUMULATE ABOVE THE TOP OF THE ASH PAN. ASHES IN CONTACT WITH THE BOTTOM OF THE GRATES ACT AS AN INSULATOR, INTENSIFYING THE HEAT ON THE GRATES AND COULD CAUSE THEIR WARPAGE. WITH AN EXCESSIVE ASH BUILDUP, PRIMARY COMBUSTION AIR IS RESTRICTED, THUS THE UNIT’S OUTPUT COULD BE REDUCED. GRATES DAMAG ...

  • United States Stove 4027 - page 17

    USSC 17 OPERATING INSTRUCTIONS continued... Before opening the loading door, open the pipe damper and the ash door first. Whenever a loading door is opened, it always should be cracked slightly to allow oxygen to enter and burn any combus- tion gases that are present before fully opening. Failure to do this could result in sudden ignition of the un ...

  • United States Stove 4027 - page 18

    18 USSC 1 2 3 4 56 7 89 10 12 11 13 16 19 14 15 18 20 17 15 16 26 25 24 20 21 22 23 4027 & ASA7 Repair Parts ...

  • United States Stove 4027 - page 19

    USSC 19 MODEL 4027 & ASA7 - PARTS LIST KEY PART NO. DESCRITION QTY. 1 40422 Cast Iron Legs 4 • 83507 3/8-16 x 1-1/4 Bolt 4 2 25096 Flue Collar 1 • 83431 Weld Tab 3 • 83045A Washer 3/8 i.d._7/8 o.d. 3 • 83432 5/16-18 x 1-1/2 Hex Bolt 3 3 25080B Door Latch 2 • 83508 5/16- 18 x 3/4 Bolt 2 • 83338 5/16- 18 Lock Nut 2 4 69338B S h a k e ...

  • United States Stove 4027 - page 20

    20 USSC THIS MANUAL WILL HELP YOU OBTAIN EFFICIENT, DEPEND- ABLE SERVICE FROM YOUR HOTBLAST FURNACE, AND EN- ABLE YOU TO ORDER REPAIR PARTS CORRECTLY. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFER- ENCE. WHEN WRITING, ALWAYS GIVE THE FULL MODEL NUMBER WHICH IS ON THE NAMEPLATE ATTACHED TO THE HEATER. WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE ...

Fabricant United States Stove Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilUnited States Stove 4027 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques United States Stove
- manuels d’utilisations 4027
- fiches produit United States Stove
- dépliants
- ou étiquettes-énergie United States Stove 4027
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation United States Stove 4027.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation United States Stove 4027, manuels d’entretien, brefs manuels ou manuels de l’utilisateur United States Stove 4027. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit United States Stove 4027.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil United States Stove 4027, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser United States Stove 4027 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs United States Stove 4027.

Le manuel d’utilisation complet United States Stove, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel United States Stove 4027 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières United States Stove 4027, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lUnited States Stove 4027 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil United States Stove 4027 - qui devraient nous aider dans les premières étapes lors de l'utilisation United States Stove 4027
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de United States Stove 4027
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service United States Stove 4027 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de United States Stove 4027?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec United States Stove 4027, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec United States Stove 4027 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image