Manuel d’utilisation Orion 52085

29 pages 1.33 mb
Télécharger

Aller à la page of 29

Summary
  • Orion 52085 - page 1

    Orion ® StarShoot ™ Pro V2.0 Deep Space Color Imager #52085 INSTRUCTION MANUAL Providing Exceptional Consumer Optical Products Since 1975 Customer Support (800 ) 676-1343 E-mail: support@telescope.com Orio n T elescopes.com Corporate Offices (831) 763-7000 89 Hangar W ay , Watsonville, CA 95076 IN 365 Rev . A 02/09 ...

  • Orion 52085 - page 2

    2 3 Filter .......................................... 26 Color Balance .................................. 27 Stretch ........................................ 29 Recommended Pr ocessing Sequence ............... 30 Note on File Format .............................. 30 Batch Pr ocess .................................. 30 4. Using the StarShoot Pro as ...

  • Orion 52085 - page 3

    4 5 1. Getting Started Parts List • StarShoot Pro V2.0 Deep Space Color Imager • 10' USB cable • 12' DC power cable with lighter plug • CD-ROM • Har d carrying case System Requir ements (refer to Figur e 1) T elescope The StarShoot Pro can be used with most telescopes compatible with 2" for - mat eyepieces. The camera is si ...

  • Orion 52085 - page 4

    6 7 Mount Deep sky imaging with the StarShoot Pro requir es an equatorial mount with a right ascension (R.A.) motor drive. The goal for your mount is to seamlessly track the apparent movement of the sky as the Earth rotates. The tracking must be very accurate, or the object you want to image will drift and blur across the camera’ s field of view ...

  • Orion 52085 - page 5

    8 9 2. Click Install . 3. The InstallShield Wizard will start. Click Next . 4. Read the Maxim DL License Agreement. If you agree with the terms, then select I accept the terms in this license agr eement and click Next . 5. Click Install . The installation will pr oceed. 6. The installation is now complete. Click the Finish button. Y ou can start Ma ...

  • Orion 52085 - page 6

    10 11 7. A Windows Security window will appear and mention that “Windows can’t verify the publisher of this driver software”. Choose Install this driver software anyway . 8. When the window appears telling you “The software for this device has been successfully installed”, click Close . This completes the driver instal- lation pr ocess. 9 ...

  • Orion 52085 - page 7

    12 13 screen, you may need to stop-down the apertur e of your telescope further . T ry making another aperture mask with a diameter of only 1⁄4". 10. T urn th e te le sco pe ’ s focu s kn ob so th e fo cus er dra wtu be mov es s low ly inward. The drawtube needs to go approximately 18mm inward from where the eyepiece focuses (for most eyep ...

  • Orion 52085 - page 8

    14 15 of the mouse. T o do this, hold down the Shift key , then left-click and drag the mouse on the image. Y ou’ll find this featur e to be a great convenience when fine adjusting the scr een stretch to get an image to look its best. Instead of using the Scr een Stretch Window , it is faster to use the Q uick Stretch facility . This allows you ...

  • Orion 52085 - page 9

    16 17 5. Click the Expose button. Y ou should see the out of focus star in the image. If you do not see anything, you need to increase the exposur e time. 6. Check that the Subframe section at the bottom of the Camera Control window has both the On and Mouse boxes checked on. 7. Draw a small box around the unfocused star with your mouse (hold-click ...

  • Orion 52085 - page 10

    18 19 V ery accurate polar alignment is essential for deep sky imaging. Stars will streak acr oss the field of view without pr ecise polar alignment and tracking. Longer exposures of 60 seconds or more also r equire autoguiding with a separate camera. The Orion StarShoot AutoGuider can be operated with the StarShoot Pr o in MaxIm DL Essentials. T ...

  • Orion 52085 - page 11

    20 21 is the Base filename , and you choose to Autosave five images, then the images will appear in the selected file folder as “OrionNebula1dark_0001. fit”, “OrionNebula1dark_0002.fit”, “OrionNebula1dark_0003.fit”, “OrionNebula1dark_0004.fit”, and “OrionNebula1dark_0005.fit”. Using the word “dark” in the Base filename ...

  • Orion 52085 - page 12

    22 23 By binning the images in 2x2, you will bypass the RGB filter built into the cam- era; so the resulting binned images will be black and white, without the ability to convert to color . 3. Image Processing After all your image data is captur ed, you are r eady to pr ocess your images to a final resultant image. All of your light images, dark ...

  • Orion 52085 - page 13

    24 25 2. Select Convert Raw to Color in the Pr ocess menu. 3. Select StarShoot Pro High Quality in the Camera T ype pull down menu (Figure 17). 4. Click OK and the image should appear in color . Y ou can make several adjustments to the Color Balance if needed (see “ Color Balance ”). Combining Deep Sky Images Each individual deep sky image is f ...

  • Orion 52085 - page 14

    26 27 sen as the r eference is r ejected fr om the stack, you will not be able to Overlay All Images . 6. Now , click the Overlay All Images button. All of the selected images will stack on top of each other to form one resultant image. Click OK Set the Screen Stretch Window to Medium (or otherwise manually adjust for best image appearance), and us ...

  • Orion 52085 - page 15

    28 29 Color images fr om CCD cameras typically require a background level adjust- ment. This is accomplished by bringing the background level (or bias) in each color plane down to zero. Each of the Background Level values is subtracted from every image pixel in its color plane. Any pixel values that become nega- tive are forced to zero. The Auto bu ...

  • Orion 52085 - page 16

    30 31 Recommended Pr ocessing Sequence What is the best order to apply the processing functions in? Here is a recom- mended sequence: 1. Calibrate (Dark Subtract and Flat Field calibrate) 2. Convert Raw to Color 3. Combine 4. Filter 5. Color Balance 6. Stretch Once you have the combined image, you ar e free to continue pr ocessing the image as desi ...

  • Orion 52085 - page 17

    32 33 5. Click OK to start the Batch Process operation. Successfully converted and saved files are removed from the list box. If an error occurred the file will remain in the list. Point the mouse cursor at an image left in the list. The appropriate err or message will appear in the Status Bar at the bottom of the MaxIm DL Essentials Edition main ...

  • Orion 52085 - page 18

    34 35 7. The ASCOM T elescope Chooser (Figure 25) will appear . Select your telescope model from the provided choices. If your model does not appear , it is not supported by the ASCOM platform. 8. After you have selected your tele - scope model, click the Properties button. 9. In the window that pops-up, choose your specific Scope T ype and desir ...

  • Orion 52085 - page 19

    36 37 telescope does not move, check the Settings . Remember , you have to set up a method for sending the autoguider commands to the telescope! 11. The star should move in an L shape. If it does not move enough, a warning message will appear . The r ecorded positions will be displayed in the scr oll- ing log, along with any err or messages. Note: ...

  • Orion 52085 - page 20

    38 39 View Menu Zoom – Increases or decreases level of image magnification on computer screen. When you zoom in too much, you will start to see the squares of indi- vidual pixels. When zoomed in, you can use Quick Pan ; simply hold down the Ctrl key , then left-click and drag the mouse on the image. Night Vision – T oggles Night V ision mode. ...

  • Orion 52085 - page 21

    40 41 5. If the star drifts north, the telescope mount is pointing too far west. If the star drifts south, the telescope mount is pointing too far east. Determine which way the star drifted and make the appropriate corr ection to the azi- muth position of the mount. Rotate the entire mount (and tripod) slightly east or west as needed or use the azi ...

  • Orion 52085 - page 22

    42 43 7. Specifications CCD Sensor: Sony ® SuperHAD ™ ICX413AQ Color Sensor format: 1.8" Pixel array: 3032x2016 (6,112,512 total) Pixel size: 7.8µm x 7.8µm Exposure range: 0.002 seconds to 9.3 hours A/D conversion: 16 bit Binning optional 2x2 Thermoelectric cooling: 30°C (54° F) below ambient temperature, sealed dry air chamber to prev ...

  • Orion 52085 - page 23

    44 45 arrows to change the speed setting (Figure 27). The minimum is 1; the maximum is 8. Check your USB connection for anything that could potentially introduce interference. Large power supplies or even a cellular phone near the camera or USB cable could interfer e with the data as it is uploaded from the camera to the computer . If you ar e usin ...

  • Orion 52085 - page 24

    46 47 600mm 138.8’ X 90.6’ 750mm 111’ X 72.5’ 900mm 92.5’ X 60.4’ Appendix B. Field of V iew Quick Refer ence Guide For your convenience, refer to the list of common telescope focal lengths and their corresponding fields of view provided by the StarShoot Pr o. The angular field of view is shown in arc-minutes. The image scale shows th ...

  • Orion 52085 - page 25

    48 49 T elescope Focal Length Angular Field of View Image Scale of the Moon Image Scale of M42 1000mm 83.3’ X 54.4’ 1250mm 66.6’ X 43.5’ 1800mm 46.3’ X 30.2’ 2032mm 41’ X 26.8’ 2540mm 32.8’ X 21.4’ 2800mm 29.7’ X 19.4’ ...

  • Orion 52085 - page 26

    50 51 T elescope Focal Length Angular Field of View Image Scale of the Moon Image Scale of M42 3000mm 27.8’ X 18.1 3910mm 21.3’ X 13.9’ Appendix C. Summarized Procedur e to Imaging Deep Sky Objects Action Process T ree Image Capture 1. Focus on a moderately bright star at least 30º (or more above the horizon). Camera Control Window , Mode ? ...

  • Orion 52085 - page 27

    52 53 Action Process T ree 4. T ake a flat field image by pointing the telescope at a uniform and featureless light source, like the sky at dawn or a white sheet of paper . Find the right exposure time that creates a Max Pixel value of approximately 20000, then proceed to Autosave your flats. Y ou do not have to take your flat fields before yo ...

  • Orion 52085 - page 28

    54 55 Notes ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ ________________________________________________________________ _____________ ...

  • Orion 52085 - page 29

    56 One-Y ear Limited W arranty This Orion StarShoot Pro V2.0 is warranted against defects in materi- als or workmanship for a period of one year from the date of purchase. This warranty is for the benefit of the original retail purchaser only . During this warranty period Orion T elescopes & Binoculars will r epair or replace, at Orion’ s op ...

Fabricant Orion Catégorie Telescope

Les documents que nous recevons du fabricant de l'appareilOrion 52085 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Orion
- manuels d’utilisations 52085
- fiches produit Orion
- dépliants
- ou étiquettes-énergie Orion 52085
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Orion 52085.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Orion 52085, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Orion 52085. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Orion 52085.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Orion 52085, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Orion 52085 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Orion 52085.

Le manuel d’utilisation complet Orion, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Orion 52085 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Orion 52085, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOrion 52085 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Orion 52085 - qui devraient nous aider dans les premières étapes lors de l'utilisation Orion 52085
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Orion 52085
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Orion 52085 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Orion 52085?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Orion 52085, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Orion 52085 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)