Manuel d’utilisation Directed Electronics 417

27 pages 2.4 mb
Télécharger

Aller à la page of 27

Summary
  • Directed Electronics 417 - page 1

    © 2000 Directed Electr onics , Inc . Vista, CA N417A 9-00 ® Model 417 Installation Guide ® : http://www. guardianalarms . net ...

  • Directed Electronics 417 - page 2

    2 © 2000 Directed Electr onics , Inc . Vista, CA What Is Included . . . . . . . . . . . . . . . . . . . . . 3 Product Description . . . . . . . . . . . . . . . . . . . 4 Installation P oints to Remember . . . . . . . . . . 4 T ools Required . . . . . . . . . . . . . . . . . . . . . . . 5 Deciding on Component Locations . . . . . . . . . 5 Siren . ...

  • Directed Electronics 417 - page 3

    © 2000 Directed Electr onics , Inc . Vista, CA 3 what is included ■ The control module (see diagr am) ■ A Rev enger ® Soft Chirp ® siren ■ The plug-in V alet ® /progr am switch ■ The plug-in status LED ■ 12-Pin primary harness ■ Starter kill relay pack age ■ A Stinger ® Doubleguard ® shock sensor on-boar d the control module 12- ...

  • Directed Electronics 417 - page 4

    4 © 2000 Directed Electr onics , Inc . Vista, CA pr oduct description This unit is used to enhance a vehi cle’s original equipm ent from m anufactur er (OEM) factory k eyless entry system by converting it in to a full-featured alarm system. It has been d esigned to work with th e factory tran smitters and to in terface with minimal wirin g to th ...

  • Directed Electronics 417 - page 5

    © 2000 Directed Electr onics , Inc . Vista, CA 5 AFTER THE INST ALLA TION ■ T est all functi ons. Th e “Using Y our System” secti on of the Own er’s Guide is very h elp ful when testin g. ■ When testin g, don’t for get that this system is equipped with Nuisan ce Preventi on Circuitry (NPC). This cir- cuitry can bypass both instan t tri ...

  • Directed Electronics 417 - page 6

    6 © 2000 Directed Electr onics , Inc . Vista, CA ■ P oint the sir en down so water does n ot collect in it. ■ Never put th e control m odule in the en gine compartmen t! ■ The first step in h ot-wiring a vehicle is r emoving th e driver's sid e under d ash panel to access th e starter and igniti on wires. If th e control m odule is plac ...

  • Directed Electronics 417 - page 7

    © 2000 Directed Electr onics , Inc . Vista, CA 7 This system has Remote V alet, so the user can en ter and exit V alet Mod e without having to r each th e V alet/program switch. DEI in trodu ced this feature so that switch location was less criti cal in day-to-day use . A s long as th e Valet/pr ogram switch can be reach ed to disarm without a tra ...

  • Directed Electronics 417 - page 8

    8 © 2000 Directed Electr onics , Inc . Vista, CA If the Failsafe ® Starter Kill Relay or its conn ections ar e immediately visible upon r emoval of th e under d ash panel, they can easily be bypassed by a thi ef. Always make th e relay and its conn ections diffi cult to discern from the factory wirin g! Exposed yellow butt connectors do n ot look ...

  • Directed Electronics 417 - page 9

    © 2000 Directed Electr onics , Inc . Vista, CA 9 How to find (+)12V ignition with y our multimeter: 1. Set to DCV or DC voltage (12V or 20V is fine). 2. Attach the (-) pr obe o f the m eter to chassis ground . 3. Probe the wir e you suspect o f being th e ignition wir e . The steerin g column harness (i gnition switch harness) is an e xcellent pla ...

  • Directed Electronics 417 - page 10

    10 © 2000 Directed Electr onics , Inc . Vista, CA making y our connections When conn ecting the security system’s wir es to the vehicle wir es it is important that the conn ections ar e ti ght and n o bare wire is e xposed. In this section, two types o f connection s are described that m ay be used to conn ect the wir es from the security system ...

  • Directed Electronics 417 - page 11

    © 2000 Directed Electr onics , Inc . Vista, CA 11 1. Using your wir e strippers an d razor knife , strip appro xim ately 1 / 2 -inch o f insulation o ff the wire to be con- nected to, with out cutting the wir e. 2. Twist th e security m odule’s wir e around th e bar e section o f the vehicle’s wir e. 3. Solder the bar e conn ection th oroughly ...

  • Directed Electronics 417 - page 12

    12 © 2000 Directed Electr onics , Inc . Vista, CA primary harness (H1) wir e connection guide This section o f the installati on guide d escribes in detail the conn ection of each o f th e primary harn ess wires. Also inclu ded are possible appli cations o f each wire . This system was design ed with th e ultimate in fle xibility and security in m ...

  • Directed Electronics 417 - page 13

    © 2000 Directed Electr onics , Inc . Vista, CA 13 IMPORT ANT! Never interrupt any wire other than the starter wire. NOTE: If connecting the H1/1 wire to control another module, such as a window controller ( P/N 529T or 530T ), a 1 amp diode (type 1N4004) will be required. Insert the diode as shown in the following diagram. H1/2 WHITE (-/+) SELECT ...

  • Directed Electronics 417 - page 14

    14 © 2000 Directed Electr onics , Inc . Vista, CA H1/3 WHITE/BLUE (+) TRUNK RELEASE, SENSOR SHUNT INPUT This input is used to bypass sensor inputs wh en the trunk is opened usin g the factory tr ansmitter . Connect this wire to th e (+) trunk release output of th e factory keyless en try system or trunk release relay . When th e system receives a ...

  • Directed Electronics 417 - page 15

    © 2000 Directed Electr onics , Inc . Vista, CA 15 H1/6 BLUE (-) INST ANT TRIGGER, ZONE 1 This input will respon d to a negative input with an instan t trigger . It is i deal for h ood and trunk pins or vehi- cles without f actory Content Th eft Deterrent (CTD). V ehicles with out CTD may requir e trunk pin s or need to be hard-wir ed to the alarm. ...

  • Directed Electronics 417 - page 16

    16 © 2000 Directed Electr onics , Inc . Vista, CA H1/10 BROWN (+) SIREN OUTPUT Connect this wir e to the red wir e of the sir en. Connect the black wir e of the sir en to (-) chassis gr ound , prefer- ably at the sam e point that you connect th e control m odule’s black groun d wire . H1/11 RED (+) 12V CONST ANT POWER INPUT Befor e connecting th ...

  • Directed Electronics 417 - page 17

    © 2000 Directed Electr onics , Inc . Vista, CA 17 plug-in harnesses The LED oper ates at 2V DC. Make sur e the LED wires ar e not shorted to gr ound because the LED will be d am aged . The LED fits in to a 9 / 32 -in ch moun ting hole . Be sure to ch eck for clearan ce pri or to drillin g the moun ting hole . The V alet/progr am switch should be a ...

  • Directed Electronics 417 - page 18

    18 © 2000 Directed Electr onics , Inc . Vista, CA oper ation mode settings ARMING AND DISARMING WITH THE OEM TRANSMITTER When conn ected to the vehicle’s d atabus, the in terface mod ule can be armed and disarm ed with th e OEM keyless en try tran smitter by pressing th e lock and unlock buttons , respectively . SENSOR SHUNT AND TRUNK TRIGGER BY ...

  • Directed Electronics 417 - page 19

    © 2000 Directed Electr onics , Inc . Vista, CA 19 NOTE: Factory content theft deterrent (CTD) systems in Bonnevilles, A uroras and LeSabres do not monitor the trunk key cylinder wire; theref ore, the trunk k ey cylinder sensor bypass feature is not available on these vehicles. The alarm will trigger if the f actory trunk release feature on the OEM ...

  • Directed Electronics 417 - page 20

    20 © 2000 Directed Electr onics , Inc . Vista, CA internal pr ogr amming jumper s T o access the jumper , open the con trol mod ule. This jumper is used to d etermine the li ght flash output. In the def ault negative (-) position, th e on-board relay is disabled an d the unit will output (-) 200 mA, suitable for drivin g factory parking li ght rel ...

  • Directed Electronics 417 - page 21

    © 2000 Directed Electr onics , Inc . Vista, CA 21 LEVEL II SECURITY MODE When this jumper is m oved to the Level II position, th e databus interf ace module will n ot disarm from the d river’s door or passen ger door k ey cylinder . The trunk tri gger zone will sh unt if opened usin g the tran smitter but will trigg er when the k ey is used or i ...

  • Directed Electronics 417 - page 22

    22 © 2000 Directed Electr onics , Inc . Vista, CA s y stem featur es learn r outine The System Featur es Learn Routine dictates h ow the unit operates . It is possible to access and chan ge any o f th e feature settin gs using the V alet/progr am switch. T o enter the System F eatures Learn Routine: 1. Open a door . 2. Key . T urn the igniti on on ...

  • Directed Electronics 417 - page 23

    © 2000 Directed Electr onics , Inc . Vista, CA 23 5. Release the V alet/progr am switch. ONCE THE FEA TURE IS PROGRAMMED ■ Other featur es can be programm ed. ■ The Learn Routin e can be exited if progr amming is complete . TO A CCESS ANOTHER FEA TURE After you have progr ammed a feature in Step 4 o f the learn routin e, pr ess and release th ...

  • Directed Electronics 417 - page 24

    24 © 2000 Directed Electr onics , Inc . Vista, CA 4 DOOR TRIGGER INST ANT/DELA YED: In the in stant (def ault) setting, if a door is open ed while the security system is armed th e system will trigger imm ediately . In the delayed settin g there is a 15-secon d delay befor e the doors will tri gger the system. This allows th e user 15 seconds to d ...

  • Directed Electronics 417 - page 25

    © 2000 Directed Electr onics , Inc . Vista, CA 25 table o f zones When usin g the diagn ostic functi ons, use th e T able of Zon es to d etermine whi ch input has trigger ed the system. It is also h elpful in deci ding which input to use wh en connecting opti onal sensors an d switch es. tr oubleshooting ■ Starter kill does not work: Is th e cor ...

  • Directed Electronics 417 - page 26

    26 © 2000 Directed Electr onics , Inc . Vista, CA ■ Closing the door triggers the s ystem, but opening the door does not: Have you corr ectly iden tified the type o f door switch system? This often happen s when the wr on g door input has been used. (See th e Finding the Wires You Need, Door Pin Switch Circuit secti on of this guid e.) ■ Syste ...

  • Directed Electronics 417 - page 27

    © 2000 Directed Electr onics , Inc . Vista, CA 27 ...

Fabricant Directed Electronics Catégorie Automobile Alarm

Les documents que nous recevons du fabricant de l'appareilDirected Electronics 417 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Directed Electronics
- manuels d’utilisations 417
- fiches produit Directed Electronics
- dépliants
- ou étiquettes-énergie Directed Electronics 417
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Directed Electronics 417.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Directed Electronics 417, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Directed Electronics 417. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Directed Electronics 417.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Directed Electronics 417, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Directed Electronics 417 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Directed Electronics 417.

Le manuel d’utilisation complet Directed Electronics, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Directed Electronics 417 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Directed Electronics 417, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDirected Electronics 417 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Directed Electronics 417 - qui devraient nous aider dans les premières étapes lors de l'utilisation Directed Electronics 417
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Directed Electronics 417
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Directed Electronics 417 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Directed Electronics 417?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Directed Electronics 417, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Directed Electronics 417 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

ВИКТОР

где расположена свеча зажигания и как поменять