Manuel d’utilisation Directed Electronics 6000

20 pages 0.08 mb
Télécharger

Aller à la page of 20

Summary
  • Directed Electronics 6000 - page 1

    This de vice complies with par t 15 of FCC rules. Operation is subject to the f ollowing two conditions: (1) This de vice ma y not cause harmful interference , and (2) This de vice m ust accept any interf erence receiv ed, including inter- f erence that ma y cause undesired operation. CA UTION: Changes or modifications not e xpressly approv ed b y ...

  • Directed Electronics 6000 - page 2

    2 © 1996 Directed Electronics, Inc. T able of C ontents System Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Y our W arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 What Is Included . . . . . . . . . . . . . . ...

  • Directed Electronics 6000 - page 3

    3 © 1996 Directed Electronics, Inc. What is included ■ The control module ■ A pair of two-b utton transmitters ■ A Stinger ® DoubleGuard ® dual-output shock sensor ■ The Re venger ® Soft Chir p ® six-tone programmab le siren ■ The red Status LED indicator light ■ A push-button V alet ® s witch ■ Y our warranty card ■ F ailSafe ...

  • Directed Electronics 6000 - page 4

    4 © 1996 Directed Electronics, Inc. T ransmitter Channels Channel I The arm/disar m and panic functions, are usually controlled b y Button I. Channel II The Silent Mode ™ /trunk release function, is usually controlled by Button II. Silent Mode ™ and Remote V alet ® work by pressing b utton II for less than one second. T r unk release requires ...

  • Directed Electronics 6000 - page 5

    5 © 1996 Directed Electronics, Inc. Using Y our S ystem Arming Y ou can tur n on, or arm , the system b y pressing button I of y our transmitter f or one second. When the system arms, y ou will hear a short siren sound, or chirp , and see the parking lights flash once. If the v ehicle’ s power door loc ks are controlled by the system, the doors ...

  • Directed Electronics 6000 - page 6

    6 © 1996 Directed Electronics, Inc. to disar m the system with y our transmitter if you inadv er tently open the door while the system is ar med, while still pro viding instant response (e v en if the door is immediately closed). • T ur ning on the ignition ke y will tr ip the same two-stage response as opening a door . • The optional starter ...

  • Directed Electronics 6000 - page 7

    7 © 1996 Directed Electronics, Inc. to check the v ehicle visually . The tr igger will stop , but the v ehicle will remain protected. T o disar m with the transmitter during a trigger , press Button I on your tr ansmitter . The siren will stop sounding. Ne xt press Button I once more and the system will chir p four or fiv e times (repor ting the t ...

  • Directed Electronics 6000 - page 8

    8 © 1996 Directed Electronics, Inc. V alet ® Mode Y ou can prev ent your system from automatically arming and tr iggering by using V alet ® Mode. This is ver y useful when w ashing the vehicle or having it ser viced. In V alet ® Mode, the system will not arm, ev en with the transmitter , but all con venience functions (door loc ks, trunk releas ...

  • Directed Electronics 6000 - page 9

    9 © 1996 Directed Electronics, Inc. trigger the system while it is being bypassed, the 60-minute b ypass period will star t ov er . This ensures that a sensor that continuously triggers will remain bypassed. Doors are cov ered by NPC ™ diff erently: If the alarm is tr iggered b y an open door f or three full cycles (one and one half minutes), th ...

  • Directed Electronics 6000 - page 10

    10 © 1996 Directed Electronics, Inc. Diagnostics The microprocessor at the hear t of your system is constantly monitoring all of the s witches and sensors connected to it. It detects any f aulty switches and sensors and pre vents them from disab ling the entire system. The micro- processor will also record and repor t any triggers that occurred du ...

  • Directed Electronics 6000 - page 11

    11 © 1996 Directed Electronics, Inc. Table of Zones The zone number is the number of LED flashes used by the system to iden- tify that input. The standard input assignments are listed below , along with spaces to write in any optional sensors or s witches you ha ve had installed. NOTE: If the Warn A way ® response is triggered, the LED will not r ...

  • Directed Electronics 6000 - page 12

    12 © 1996 Directed Electronics, Inc. C ode Hopping ™ Explained The receiver and tr ansmitters each use a mathematical formula called an algorithm to change their code each time the transmitter is used. This tech- nology has been de v eloped to increase the security of the unit. The control unit knows what the ne xt codes should be. This helps to ...

  • Directed Electronics 6000 - page 13

    13 © 1996 Directed Electronics, Inc. NOTE: If the door is open when the ignition is turned on, the doors will not lock. • P anic mode enabled /disab led with the ignition on. (Some states hav e laws against siren capability in a moving v ehicle). • A utomatic Engine Disable (AED) on or off . The pur pose of the feature is to pro- tect the vehi ...

  • Directed Electronics 6000 - page 14

    14 © 1996 Directed Electronics, Inc. V ehicle R ecovery S ystem (V RS ® )* The optional V ehicle Recovery System feature is designed to ensure that an y unauthorized user of your v ehicle (ev en if using your ke ys and remote con- trol) will not be able to permanently separate you from y our vehicle . The VRS ® f eature cannot pre vent a carjac ...

  • Directed Electronics 6000 - page 15

    15 © 1996 Directed Electronics, Arming the VR S ® T o ar m the VRS ® , push the b utton once. This can be done before driving or while driving the vehicle. Once the system is ar med, it will go into its triggered sequence (see below) if an y door is opened and closed. If you are f orced from the v ehicle the system will trigger as the door will ...

  • Directed Electronics 6000 - page 16

    F rom this point on, when the ignition k e y is turned off, the VRS ® will immediately turn on the F ailSafe ® starter kill. This will pre- vent the v ehicle from being restar ted, thus immobilizing it at that spot. Three minutes after the constant siren output begins, the flashing parking lights and the siren will stop. The star ter kill will re ...

  • Directed Electronics 6000 - page 17

    17 © 1996 Directed Electronics, Inc. Gloss ary of T erms Control Unit The “brain” of y our system. Usually hidden under neath the dash area of the vehicle . It houses the microprocessor which monitors y our vehi- cle and controls all of the alarm's functions. FailSaf e ® Starter Kill An automatic switch controlled b y the secur ity syste ...

  • Directed Electronics 6000 - page 18

    18 © 1996 Directed Electronics, Inc. Security & C onvenience Expansions Here we ha v e listed only some of the many e xpansion options av ailable . Please consult your dealer f or a complete explanation of all the options a vail- able to y ou. Field Disturbance Sensor : An invisible dome of co verage is estab lished by the 508T “radar” sen ...

  • Directed Electronics 6000 - page 19

    19 QU ICK RE FE RE NCE OPE RA TING C ARD : Arming ▼ Y ou can turn on, or ar m, the system b y pressing Button I of your transmitter f or one second. When the system arms, you will hear a shor t chir p, and see the parking lights flash once . Arming While Driving ▼ Press Button I on y our transmitter while the v ehicle is r unning. The system wi ...

  • Directed Electronics 6000 - page 20

    S ystem Ref er ence Car d Directed Electronics, Inc. 2560 Progress Street Vista, CA 92083-8491 © Copyright 1990, 1996 Directed Electronics, Inc. - All rights reserved G437 12/96 The company behind DEI ® is Directed Electr onics, Inc. Since its inception, the company known as Directed Electronics, Inc. (DEI ® ) has had one pur pose - to br ing th ...

Fabricant Directed Electronics Catégorie Stud Sensor

Les documents que nous recevons du fabricant de l'appareilDirected Electronics 6000 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Directed Electronics
- manuels d’utilisations 6000
- fiches produit Directed Electronics
- dépliants
- ou étiquettes-énergie Directed Electronics 6000
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Directed Electronics 6000.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Directed Electronics 6000, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Directed Electronics 6000. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Directed Electronics 6000.

Manuel d’utilisation complet de l’appareil Directed Electronics 6000, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Directed Electronics 6000 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Directed Electronics 6000.

Le manuel d’utilisation complet Directed Electronics, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Directed Electronics 6000 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Directed Electronics 6000, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDirected Electronics 6000 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Directed Electronics 6000 - qui devraient nous aider dans les premières étapes lors de l'utilisation Directed Electronics 6000
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Directed Electronics 6000
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Directed Electronics 6000 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Directed Electronics 6000?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Directed Electronics 6000, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Directed Electronics 6000 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)