    FIELDPOINT OPERATING INST RUCTIONS AND SPECIFICATIONS cFP-2200/2210/2220 Intelligent Real-Time Contro llers for Compact FieldPoint Figure 1. cFP-22 xx , Front and Bottom Views 1 RS-232 Serial Port 2 RJ-45 Ethernet Port 1 3 Removable Compact F lash (cFP-2220 Only) 4 Status LED 5 Power LED 6 User-Configurable LEDs 7 DIP Switches 8 USB Port (cFP-2220 ...

  • National Instruments Fieldpoint CFP-2200 - page 2

    cFP-2200/2210/2220 2 ni.com This document describes how to mount the cFP-2200/2210/2220 controllers, how to connect the controllers to networks, and how to use the feature s of the control lers. This document also contains specif ications for the controllers. In this docum ent, the cFP-2200/2210/2220 controll ers are referred to inclusi vely as the ...

  • National Instruments Fieldpoint CFP-2200 - page 3

    © National Instruments Corporatio n 3 cFP-2200/2210/2220 has the following symbol stamped besi de it: . Connect the backplane PE ground terminal to safety ground usin g 14 A WG (1.6 mm) wire with a ring lug. Use the 5/16 in. panhead scre w sh ipped with the backplane to secure the ring lug to the backplane PE ground termin al. T o ensure maximum c ...

  • National Instruments Fieldpoint CFP-2200 - page 4

    cFP-2200/2210/2220 4 ni.com Figure 3. cFP-22 xx Installed on cFP-BP- x , Bottom View with Dimensions Figure 4. cFP-22 xx Installed on cFP-BP-4, Front View with Dimensions C ab ling Cle a r a nce 4 s lot s = 246 mm (9.6 8 in.) 8 s lot s = 441 mm (17.4 in.) Cooling O u tline 51 mm (2 in.) Cooling O u tline 51 mm (2 in.) Min. 1 8 2 mm (7.1 8 in.) 106 ...

  • National Instruments Fieldpoint CFP-2200 - page 5

    © National Instruments Corporatio n 5 cFP-2200/2210/2220 Figure 5. cFP-BP-8, Back View with Dimensions Figure 6. cFP-BP-4, Back View with Dimensions Caution Make sure that no I/O modules are in the backplane before m ounting it. 104.78 mm (4.1 in.) 63.50 mm (2.5 in.) 22.23 mm (0.9 in.) 33.15 mm (1.3 in.) 129.54 mm (5.1 in.) 311.40 mm (12.3 in.) 38 ...

  • National Instruments Fieldpoint CFP-2200 - page 6

    cFP-2200/2210/2220 6 ni.com Mounting the Backplane on a DIN Rail The DIN rail mounting kit is NI part nu mber 778614-01. You need one kit to mount the cFP-BP-4 on a standard 35 mm DIN rail. Complete the following step s to mount th e backplane on a DIN rail. 1. Fasten the DIN rail clip to the cFP-BP-4 using a number 2 Phillips screwdri ver and the ...

  • National Instruments Fieldpoint CFP-2200 - page 7

    © National Instruments Corporatio n 7 cFP-2200/2210/2220 3. Press do wn firmly on the backplane to compress the spring u ntil the clip locks in place on the DIN rail. 4. Connect the PE ground terminal on the backplane to safety ground. Caution Disconnect power and mak e sure that no I/O modules are in the backplane before remo ving it from the DI ...

  • National Instruments Fieldpoint CFP-2200 - page 8

    cFP-2200/2210/2220 8 ni.com Figure 10. cFP-BP-4 with Horizontal Panel Mount Kit Installed, Front View with Dimensions Figure 11. cFP-BP-8 with Horizontal Panel-Mount Ki t Installed, Front View with Dimensions Figure 12. Installing th e Vertica l Pa nel-Mount Kit on the cFP-BP-4 260 mm (10.25 in.) 102 mm (4 in.) 102 mm (4 in.) 457 mm (18 in.) N A T ...

  • National Instruments Fieldpoint CFP-2200 - page 9

    © National Instruments Corporatio n 9 cFP-2200/2210/2220 Figure 13. cFP- BP-4 with Vertical Pa nel-Mount Kit Installed, Front View with Dimensions Figure 14. cFP- BP-8 with Vertical Pa nel-Mount Kit Installed, Front View with Dimensions 2. Bolt or screw the plates to a panel. 3. Connect the PE ground terminal on the cFP-BP- x to safety ground. Cau ...

  • National Instruments Fieldpoint CFP-2200 - page 10

    cFP-2200/2210/2220 1 0 ni.com Mounting the Backplane in a Standard 19 in. Rack The rack-mount kit for Compact FieldPoint is NI part number 778 615-01. The following figure shows the dimensions of the rack -mount kit. Figure 15. Dimensions of Rack-Mount Kit Complete the following steps to mount the system in a rack. 1. Fasten the rack-mount bracke t ...

  • National Instruments Fieldpoint CFP-2200 - page 11

    © National Instruments Corporatio n 11 cFP-2200/2210/2220 Figure 16. Installing the Rack-Mount Bracket on the cFP-BP-4 Figure 17. Installing the Rack-Mount Bracket on the cFP-BP-8 N AT ION AL INST R UMEN TS NATIO NA L INST RUMENTS ...

  • National Instruments Fieldpoint CFP-2200 - page 12

    cFP-2200/2210/2220 1 2 ni.com 2. Bolt the rack-mount bracket to a standard 19 in. rack. 3. Connect the PE ground terminal on the cFP-BP- x to safety ground. Caution Disconnect power and mak e sure that no I/O modules are in the backplane before remov ing it from the rack. Y ou can install an 8 in. DIN rail in the rack-mount kit to mount a power sup ...

  • National Instruments Fieldpoint CFP-2200 - page 13

    © National Instruments Corporatio n 13 cFP-2200/2210/2220 Installing the cFP-22 xx on the Backplane 1. Make sure that no po wer is connected to the controller . 2. Make sure that the controller is rig ht side up with the NI logo at the top, and align the capti ve scre ws on the controller with the holes on the backplane. 3. Seat the card edge at t ...

  • National Instruments Fieldpoint CFP-2200 - page 14

    cFP-2200/2210/2220 1 4 ni.com Installing I/O Modules on the Backplane 1. Align the captive scre w s on the I/O modu le with the holes on the backplane. 2. Press firmly to seat the I/O module on the backplane. 3. Using a number 2 P hillips scr ewdri ver with a shank of at least 64 mm (2.5 in.) length, tighten the captive scre ws to 1.1 N · m (10 lb ...

  • National Instruments Fieldpoint CFP-2200 - page 15

    © National Instruments Corporatio n 15 cFP-2200/2210/2220 Installing Connector Blocks on the Backplane In order to connect I/ O modules to input si gnals or loads, you need to install a cFP-CB- x connector block or other conn ectibility accessory for each I/O module on the backplane. Use the connect or socket to the right of each I/O module socket ...

  • National Instruments Fieldpoint CFP-2200 - page 16

    cFP-2200/2210/2220 1 6 ni.com Figure 21. Installing a Connector Block on the Backplane 4. Using a number 2 P hillips scr ewdri ver with a shank of at least 64 mm (2.5 in.) length, tighten the captive scre ws to 1.1 N · m (10 lb · in.) of torque. 5. Repeat this procedure to install additional connector blocks on the backplane. ...

  • National Instruments Fieldpoint CFP-2200 - page 17

    © National Instruments Corporatio n 17 cFP-2200/2210/2220 Connecting the cFP-22 xx to a Network Connect the cFP-22 xx to an Ethern et network using RJ-4 5 Ethernet port 1 on the controller front panel. Use a st andard Category 5 (CAT-5) or better Ethernet cable to connect the controller to an Ethernet hub, or use an Ethernet crossover cable to con ...

  • National Instruments Fieldpoint CFP-2200 - page 18

    cFP-2200/2210/2220 1 8 ni.com Wiring Power to the cFP-22 xx The cFP-22 xx requires an external power supply that meets the specifications in the Power Requirements section. The cFP-22 xx filters and regulates the supplied power an d provides power for all of the I/O mo dules. Y ou must connect a power supply to at least one pair of V and C terminal ...

  • National Instruments Fieldpoint CFP-2200 - page 19

    © National Instruments Corporatio n 19 cFP-2200/2210/2220 2. Install a tie wrap or o ther device on the po wer wires to secure the ferrite in place near the controller po wer connector , as shown in Figure 24. Figur e 24. Ferrite Installed with Tie Wrap 3. Connect the positive lead of the po wer suppl y to the V1 terminal of the COMBICON connector ...

  • National Instruments Fieldpoint CFP-2200 - page 20

    cFP-2200/2210/2220 2 0 ni.com Note The controller indicates which terminal it is using on the channel called Power Source in software. A value of 0 indicates V2, and a value of 1 indicates V1. This beh avior is dif ferent from that of older Compact Fiel dPoint contr ollers. If your app lication uses input from the Power Source channel, you must cha ...

  • National Instruments Fieldpoint CFP-2200 - page 21

    © National Instruments Corporatio n 21 cFP-2200/2210/2220 COM 1 COM 1 is an RS-232 DTE serial port with a standard DB-9 connector. The Serial VIs access COM 1 as port 0. The following fi gure shows the locations of the DB-9 connector pins and Table 1 lists the signals on the pins. Figure 25. Controller Serial Port COM 2 (cFP-2210 and cFP-2220 Only ...

  • National Instruments Fieldpoint CFP-2200 - page 22

    cFP-2200/2210/2220 2 2 ni.com COM 4 (cFP-2220 Only) COM 4 is an RS-485 serial port with a 10-position modular jack. The Serial VIs access COM 4 as port 3. COM 4 has 100 V rms of operational isolat ion. Use an external RS-485 isol ator if your applicat ion requires more isolatio n. Refer to Figure 26 and Table 2 for pin locations and signal descript ...

  • National Instruments Fieldpoint CFP-2200 - page 23

    © National Instruments Corporatio n 23 cFP-2200/2210/2220 Figure 27 sho ws how to wire se veral FP-1001 banks in an RS-485 net work controlled by the cFP-2220. Only tw o FP-1001 banks are shown, b ut the cFP-2220 can control up to 24 FP-1001 banks. Inst all 120 Ω termination resistors at each end of the network as s hown in Figure 27. Figure 27. ...

  • National Instruments Fieldpoint CFP-2200 - page 24

    cFP-2200/2210/2220 2 4 ni.com Y ou can use the two digital input s to control the cFP system from LabVIEW . For example, one input could be a ST AR T/STOP switch, and the other could determine which of two VIs should run at startup. NI recommends connecting a single-pole single-throw (SPST) switch between the input terminal and on e of the C te rmi ...

  • National Instruments Fieldpoint CFP-2200 - page 25

    © National Instruments Corporatio n 25 cFP-2200/2210/2220 Configuring DIP Switches Figure 29. DI P Switches All of the DIP switches are in the OFF position when the controller is shipped from National Instruments. IP RESET Switch Push the IP RESET switch to the ON position and reb oot the controller to reset the IP address to 0.0.0.0 . If the cont ...

  • National Instruments Fieldpoint CFP-2200 - page 26

    cFP-2200/2210/2220 2 6 ni.com NO APP Switch Push the NO APP switch to the ON position to pr event a LabVIEW RT startup application from running at startup . If you want to permanently disable a LabVIEW RT app lication from running at startup, you m ust disable it in LabVIEW. To run an application at startup , push the NO APP switch to the OFF posi ...

  • National Instruments Fieldpoint CFP-2200 - page 27

    © National Instruments Corporatio n 27 cFP-2200/2210/2220 Using the Reset Button Pressing the Reset button resets the processor in the same m anner as cycling power. Understanding LED Indications Figure 30. LEDs ST A TUS LED The STATUS LED is off during normal operation. The cFP-22 xx indicates specific error conditions by flash ing th e STATUS LE ...

  • National Instruments Fieldpoint CFP-2200 - page 28

    cFP-2200/2210/2220 2 8 ni.com POWER LED The POWER LED is lit while the cFP-22 xx is powered on. This LED indicates that the power supply con nected to the controller is adequate. The POWER LED lights green when the co ntroller i s using the primary p ower supply and amber when the controller is u sing the secondary power supply. User -Configurable ...

  • National Instruments Fieldpoint CFP-2200 - page 29

    © National Instruments Corporatio n 29 cFP-2200/2210/2220 Remote Front Panels You may need to monitor and cont rol an embedded VI remotely. The cFP-22 xx supports multiple rem ote front panels for embedded VIs. Users can view the remote front panel using either LabVIEW or a Web browser. Users accessing the remote front panels with a W eb browser n ...

  • National Instruments Fieldpoint CFP-2200 - page 30

    cFP-2200/2210/2220 3 0 ni.com T roubleshooting This section contains troubleshoo ting instructions for the cFP-2 2 xx and FieldPoint software. For mo re troubleshooting in formation, refer to the Measurement & Automation Explorer Help for FieldPoint and the Measurement & Automation Explorer Remote Systems Help . Runaway Startup Application ...

  • National Instruments Fieldpoint CFP-2200 - page 31

    © National Instruments Corporatio n 31 cFP-2200/2210/2220 Specifications The following specifications are typi cal for the – 40 to 70 °C operating temperature range unless otherwi se noted. Network Network interface ....................... ............ 10BaseT and 100BaseTX Ethernet Compatibility ......... .............. ................. . IEE ...

  • National Instruments Fieldpoint CFP-2200 - page 32

    cFP-2200/2210/2220 3 2 ni.com RS-232 (DTE) serial ports Maximum baud rate ................ .........115,200 bps Data bits ........... .............. ................. .5, 6, 7, 8 Stop bits ....................... ................ ....1, 1.5, 2 Parity............. ................. ................. .Odd, Even, Mark, Space Flow control........ ..... ...

  • National Instruments Fieldpoint CFP-2200 - page 33

    © National Instruments Corporatio n 33 cFP-2200/2210/2220 Physical Characteristics If you need to clean the controller, wipe it with a dry towel. Screw-terminal wiring ..... .............. ......... Use copper conductor wire with 10 mm (0.39 in.) of insulation from the ends. External digital I/O termin als ......... 16 to 28 AWG Power supply termi ...

  • National Instruments Fieldpoint CFP-2200 - page 34

    cFP-2200/2210/2220 3 4 ni.com Electromagnetic Compatibility This product is designed to meet the requirements of the follow ing standards of EMC for el ectrical equipment for m easurement, control, and laboratory use: • EN 61326 EMC requirements; In dustrial Immunity • EN 55011 Emissions; Gro up 1, Class A • CE, C-T ick, ICES, and FCC Part 15 ...

  • National Instruments Fieldpoint CFP-2200 - page 35

    © National Instruments Corporatio n 35 cFP-2200/2210/2220 Environmental The cFP-22 xx is intended for indoor use only, but it m ay be used outdoors if mounted in a suitably r ated enclosure. Operating temperature (IEC 60068-2-1, IEC 60068-2-2) ........... – 40 to 70 °C Note T o meet this operating temperature range, f ollow the guidelines in th ...

  • National Instruments Fieldpoint CFP-2200 - page 36

    cFP-2200/2210/2220 3 6 ni.com Cabling Table 4 shows the standard Ethernet cable wiring connection s for both normal and crossover cables. Figure 31. Ethernet Connector Pinout Table 4. Ethernet Cable Wiring Connections Pin Connector 1 Connector 2 (Normal) Connector 2 (Crossover) 1 white/orange white/orange white/green 2 orange orange green 3 white/g ...

  • National Instruments Fieldpoint CFP-2200 - page 37

    © National Instruments Corporatio n 37 cFP-2200/2210/2220 Where to Go for Support The National Instrum ents W eb site is your complete resource for t echnical support. At ni.com/support you hav e access to ev erything from troubleshooting and ap plication devel opment self-help resources to email and phone assistance from NI Application Engin eers ...

  • National Instruments Fieldpoint CFP-2200 - page 38

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for m ore informat ion about Natio nal Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trade names of their respective companie s. For patents coveri ng Nat ...

Fabricant National Instruments Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilNational Instruments Fieldpoint CFP-2200 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations Fieldpoint CFP-2200
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments Fieldpoint CFP-2200
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments Fieldpoint CFP-2200.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments Fieldpoint CFP-2200, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments Fieldpoint CFP-2200. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments Fieldpoint CFP-2200.

Manuel d’utilisation complet de l’appareil National Instruments Fieldpoint CFP-2200, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments Fieldpoint CFP-2200 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments Fieldpoint CFP-2200.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments Fieldpoint CFP-2200 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments Fieldpoint CFP-2200, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments Fieldpoint CFP-2200 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments Fieldpoint CFP-2200 - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments Fieldpoint CFP-2200
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments Fieldpoint CFP-2200
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments Fieldpoint CFP-2200 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments Fieldpoint CFP-2200?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments Fieldpoint CFP-2200, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments Fieldpoint CFP-2200 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)