  • Pentair IC20, IC40 - page 1

    IMPOR T ANT SAFETY INSTR UCTIONS READ AND FOLLO W ALL INSTR UCTIONS SA VE THESE INSTR UCTIONS Installation and User’ s Guide IntelliChlor ™ Electr onic Chlorine Generator (Model IC20, IC40) Patents pending ...

  • Pentair IC20, IC40 - page 2

    © 2006 P entair W ater P ool and Spa, Inc. All rights reser ved This document is subject to change without notice 1620 Hawkins A v e., Sanf ord, NC 27330 • (919) 566-8000 10951 W est Los Angeles Av e., Moorpar k, CA 93021 • (805) 553-5000 T rademarks and disclaimer s IntelliChlor , IntelliT ouch, EasyT ouch and the P entair W ater Pool and Spa ...

  • Pentair IC20, IC40 - page 3

    i IntelliChlor Installation and User ’ s Guide Contents IntelliChlor Overview .................................................................................................................................... 1 Features .............................................................................................................................. ...

  • Pentair IC20, IC40 - page 4

    ii IntelliChlor Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS Impor tant Notice: Attention Installer: This manual contains impor tant information about the installation, operation and saf e use of this product. This information should be given to the owner and/or operator of this equipment. When installing and using this electrical ...

  • Pentair IC20, IC40 - page 5

    iii IntelliChlor Installation and User ’ s Guide IMPORTANT SAFETY PRECAUTIONS CA UTION - Use of chemicals other than those recommended ma y be hazardous. Follo w the Chemical Manuf acturer’ s Instructions. CA UTION - T o reduce the risk of electr ic shock, install IntelliChlor cell at least 5 f eet from the inside wall of the pool. CA UTION - I ...

  • Pentair IC20, IC40 - page 6

    iv IntelliChlor Installation and User ’ s Guide Installation Steps Summary The recommended IntelliChlor installation steps are: Revie w Chemistr y Y ou Need to Know (pa g e 11) : Review this important information. Review Optim um P ool W ater Conditions (page 12) : Review NSPI standards information. Review P ool W ater Preparation (page 16) : Rev ...

  • Pentair IC20, IC40 - page 7

    1 IntelliChlor Installation and User ’ s Guide IntelliChlor Overview The IntelliChlor™ salt chlorinator uses a process known as electrolysis to produce Sodium Hypochlorite (liquid chlorine) from a low concentration of salt added to the pool water . Hypochlorite kills bacteria, oxidizes organic material, and kills algae, then reverts back to sal ...

  • Pentair IC20, IC40 - page 8

    2 IntelliChlor Installation and User ’ s Guide Electrolytic Cell Controller The electrolytic cell controller includes a control panel with buttons and LED indicators to fully control and produce chlorine. The cell controller measures the water temperature and salt level to optimally produce chlorine. If the salt level is too low (red on salt disp ...

  • Pentair IC20, IC40 - page 9

    3 IntelliChlor Installation and User ’ s Guide IntelliChlor P ower Center The Power Center converts AC electrical current to a low voltage DC current which is required by the cell to perform the electrolysis. The power supply is connected with the pool circulation pump electrical source so that the electrolytic cell only operates when the pool pu ...

  • Pentair IC20, IC40 - page 10

    4 IntelliChlor Installation and User ’ s Guide Loop Plumbing Diagram The IntelliChlor will operate in water flow rates from 15 gallons per minute up to 1 10 gallons per minute (the limit of 2” plumbing). For flow rates over 80 gallons per minute, it is recommend that you use a bypass loop (shown below) for best chlorine production. Installation ...

  • Pentair IC20, IC40 - page 11

    5 IntelliChlor Installation and User ’ s Guide Section 1 IntelliChlor Control P anel This section describes the IntelliChlor control panel status LEDs and the More, Less and Boost/On/Off control buttons. Salt Level Status LEDs The salt level is checked daily and is displayed on this section of the unit. • Green: Good salt. The water salt le vel ...

  • Pentair IC20, IC40 - page 12

    6 IntelliChlor Installation and User ’ s Guide Operator Control P anel (continued) Sanitizer Output LED Indicators The five LED indicators display as a bar graph to show in 20% increments, the amount of time the chlorine is produced per hour . In BOOST mode, these LEDs scroll in a pattern. • 0 % No LEDs on indicate no chlorine produced - Intell ...

  • Pentair IC20, IC40 - page 13

    7 IntelliChlor Installation and User ’ s Guide Section 2 Operating IntelliChlor This section describes the start up procedure and operating instructions for IntelliChlor . Initial Star t up P eriod For the first 30 days of cell operation, the self-cleaning cycle will be set to two hours. After 30 days has elapsed, the unit will automatically set ...

  • Pentair IC20, IC40 - page 14

    8 IntelliChlor Installation and User ’ s Guide Startup Procedure (Super Chlorination) Shocking (Super Chlorination) is recommended before pool startup. Start out with clean pool water from the beginning. IntelliChlor will build up a sufficient level of chlorine for sanitation in several hours. However , if pool water has a high demand from the st ...

  • Pentair IC20, IC40 - page 15

    9 IntelliChlor Installation and User ’ s Guide Section 3 User Maintenance This section describes how to maintain the IntelliChlor chlorination system. Daily service. None is needed. W eekly service . 1. Chlorine T est: T est pool water chlorine level with a reliable test kit. Maintain ideal range by adjusting IntelliChlor chlorine production rate ...

  • Pentair IC20, IC40 - page 16

    10 IntelliChlor Installation and User ’ s Guide Monthly Service (Continued) 3. T otal Alkalinity T est: T est pool water for total alkalinity with a test kit. Adjust according to your pool professional’ s recommendations. 80-120 PPM APSP Standard. 4. St abilizer (Cyanuric Acid): T est pool water stabilizer ( cyanuric acid ) level using a test k ...

  • Pentair IC20, IC40 - page 17

    11 IntelliChlor Installation and User ’ s Guide WARNING Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves and eye protection. Always add acid to water, do not add water to acid. Always work in a well-ventilated area. Splashing or spilling acid can cause severe personal injury and/or property damage. d. ...

  • Pentair IC20, IC40 - page 18

    12 IntelliChlor Installation and User ’ s Guide Optimum P ool W ater Conditions In accordance with the Association of Pool and Spa Professionals (APSP) standards, it is recommended that the following water balance conditions be maintained on an on going basis to protect the pool finish and equipment and ensure the pleasing appearance of the water ...

  • Pentair IC20, IC40 - page 19

    13 IntelliChlor Installation and User ’ s Guide Chlorine T esting It is recommended that chlorine test samples be taken from two places. Compare the samples. A higher level should be found at the pool return line. The higher level at the pool return line indicates IntelliChlor is producing chlorine. T ake chlorine test samples: • At the pool re ...

  • Pentair IC20, IC40 - page 20

    14 IntelliChlor Installation and User ’ s Guide How to Ad d Salt to the Pool CA UTION: Do not operate IntelliChlor with newly poured pool plaster; salt damage can occur . W ait at least 1 MONTH to allow new pool plaster to cure before operating IntelliChlor . 1. Switch on the pump to circulate the pool water . 2. Determine the amount of salt from ...

  • Pentair IC20, IC40 - page 21

    15 IntelliChlor Installation and User ’ s Guide T able 2. Approximate Pounds (kg) of Salt Needed to Maintain 3,000 PPM T able 3. Approximate Amount of Chlorine S tabilizer (Cyanuric Acid) Needed to Obtain 75 PPM NOTE: Add 1.25 lb (0.57 kg) Chlorine S tabilizer to the pool every time 50 lb (22.7 kg) of Salt is added to the pool. The S tabilizer re ...

  • Pentair IC20, IC40 - page 22

    16 IntelliChlor Installation and User ’ s Guide P ool W ater Preparation Determining P ool Size (m3 of W ater in Y our P ool) • Rectangular Pools: Length x width (meters) x average depth x 1000 • Circular Pools: Diameter x diameter x average depth x 785 • Oval Pools: Length x width (meters) x average depth x 893 • Sloping Sides: Multiply ...

  • Pentair IC20, IC40 - page 23

    17 IntelliChlor Installation and User ’ s Guide Section 4 Installation This section describes how to install the IntelliChlor electrolytic cell assembly into the pool plumbing system. Also, included are connection instructions for IntelliT ouch and EasyT ouch systems. Before installing, review the IntelliChlor kit contents and required tools. Not ...

  • Pentair IC20, IC40 - page 24

    18 IntelliChlor Installation and User ’ s Guide Installing the Cell Assembly Install the IntelliChlor cell assembly no closer than three (3) feet from the heater outlet, if used. For more information see plumbing diagrams on page 3 and 4. Note: After new pool construction has been completed, in or der to pr event debris fr om entering the Intelli ...

  • Pentair IC20, IC40 - page 25

    19 IntelliChlor Installation and User ’ s Guide Connecting the P ower Center to an IntelliT ouch or EasyT ouch System T o operate IntelliChlor with the IntelliT ouch or EasyT ouch system, connect a four wire cable from the IntelliChlor Power Center to the IntelliT ouch or EasyT ouch load center . An alternate connection can be made by splicing an ...

  • Pentair IC20, IC40 - page 26

    20 IntelliChlor Installation and User ’ s Guide Connecting IntelliChlor to an IntelliT ouch System T o connect the four wire cable communication from the IntelliChlor Power Center (see page 19) to the Personality board located in the IntelliT ouch load center: W ARNING Switch OFF main system power to the Load Center bef ore making any connections ...

  • Pentair IC20, IC40 - page 27

    21 IntelliChlor Installation and User ’ s Guide Connecting IntelliChlor to an EasyT ouch System T o connect the four wire cable from the IntelliChlor Power Center (see page 19) to the motherboard located in the EasyT ouch load center: W ARNING Switch OFF main system pow er to the load center before making any connections . 1. Unlatch the load cen ...

  • Pentair IC20, IC40 - page 28

    22 IntelliChlor Installation and User ’ s Guide Section 5 T r oubleshooting Use the following troubleshooting information to resolve possible problems with the IntelliChlor system. Note: Switch power off to unit before to attempting service or repair . Always remove AC power to Power Center when plugging or unplugging the IntelliChlor cell into t ...

  • Pentair IC20, IC40 - page 29

    23 IntelliChlor Installation and User ’ s Guide m e l b o r Pe s u a C e l b i s s o Pn o i t c A e v i t c e r r o C s i t h g i l t l a s D D A d e R . n o g n i e b s i e n i r o l h c o N . t l a s s d e e n r e t a w l o o P . d e c u d o r p d n a , 4 1 , 3 1 s e g a p n o d e b i r c s e d s a t l a s d d A . 5 1 s i t h g i l t l a s W O ...

  • Pentair IC20, IC40 - page 30

    24 IntelliChlor Installation and User ’ s Guide System Specifications - 110 V A C and 220 V A C Wiring Circuit Protection: T wo-pole 20 AMP device at the electrical panel. IntelliChlor Model IC20 Input: 90-130 V AC, 50/60 Hz, 220 W atts (2 AMP) or 220-240 V AC, 50/60 Hz, 220 W atts (1 AMP). Output: 22-39 VDC @ 6 AMPS maximum from the Power Center ...

  • Pentair IC20, IC40 - page 31

    LIMITED WARRANTY P entair Water P ool and Spa, Inc. ("P entair W ater") manufactures its products with the highest standards of wo r kmanship, using the best materials av ailable through state of the ar t process. P entair W ater warrants its products as follo ws: Limited W arranty: Pentair Water w arrants its products to be free from def ...

  • Pentair IC20, IC40 - page 32

    P/N 520589 - Rev D ...

Fabricant Pentair Catégorie Portable Generator

Les documents que nous recevons du fabricant de l'appareilPentair IC20, IC40 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Pentair
- manuels d’utilisations IC20, IC40
- fiches produit Pentair
- dépliants
- ou étiquettes-énergie Pentair IC20, IC40
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Pentair IC20, IC40.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Pentair IC20, IC40, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Pentair IC20, IC40. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Pentair IC20, IC40.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Pentair IC20, IC40, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Pentair IC20, IC40 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Pentair IC20, IC40.

Le manuel d’utilisation complet Pentair, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Pentair IC20, IC40 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Pentair IC20, IC40, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPentair IC20, IC40 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Pentair IC20, IC40 - qui devraient nous aider dans les premières étapes lors de l'utilisation Pentair IC20, IC40
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Pentair IC20, IC40
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Pentair IC20, IC40 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Pentair IC20, IC40?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Pentair IC20, IC40, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Pentair IC20, IC40 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image