Manuel d’utilisation Stovax 8542-P8542

28 pages 0.68 mb
Télécharger

Aller à la page of 28

Summary
  • Stovax 8542-P8542 - page 1

    C l a r e n d o n a n d A s h d o n C o a l E f f e c t S t o v e R a n g e C on v en t io n al F l ue With upgradeable control valve I ns t r uc t io n s f or U se , I ns t a ll a ti o n a nd S er v i ci n g Fo r use i n G B, IE (G re at Br it ain a nd Ei re ) PR0613 Issue 4 (Februarry 2007)) IMPORTANT Do not attempt to burn rubbish in this fire. ...

  • Stovax 8542-P8542 - page 2

    2 CONTENTS COVERING THE FOLLOWING MODELS CLARENDON - 8541 - P8541 / 8517 - P8517 - 8542 - P8542 / 8518 - P8518 - 8543 - P8543 / 8519 - P8519 ASHDON - 8513 - P8513 / 8522 - P8522 PAGE APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 10 Technical Specifications 10 Site Requirements 11 Installation 12 Commissioning 17 ...

  • Stovax 8542-P8542 - page 3

    3 APPLIANCE COMMISSIONING CHECKLIST Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Stovax 8542-P8542 - page 4

    1.11 Contact a competent service engineer to carry out relevant spillage checks etc. following home improvements after installation of this stove (e.g. the fitting of double glazing). 1.12 In all correspondence, please quote the appliance type and serial number which can be found on the databadge at the rear of the stove. 1.13 This product is guara ...

  • Stovax 8542-P8542 - page 5

    5 3.1 To turn the stove off, locate the control valve, turn the left- hand control knob until it points to off ( ). The main burner goes out leaving the pilot burning. 3.2 To turn the pilot off, locate the control valve, turn the right- hand control knob until it points to off ( ), the pilot goes out. 4.1 Your stove is fitted with a control valve t ...

  • Stovax 8542-P8542 - page 6

    6 USER INSTRUCTIONS 6.1 Place the flame baffle onto the burner and push up against the rear tray lip, see diagram 4. 6.2 Locate the rear panel against the spacer brackets and slide down so that it locates on the ledge of the flame baffle, see diagram 5. 6.3 Locate the front coal between the heat shield and flame baffle so that its ends sit flat aga ...

  • Stovax 8542-P8542 - page 7

    7 6.7 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and the tool supplied, do not over tighten the nuts, see diagram 10. Keep the tool with these instructions for future use. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED ...

  • Stovax 8542-P8542 - page 8

    8 USER INSTRUCTIONS 6.13 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and the tool supplied, do not over tighten the nuts, see diagram 16. Keep the tool with these instructions for future use. NEVER OPERATE THE STOVE WHEN ...

  • Stovax 8542-P8542 - page 9

    9 6.19 Ensure that the fibreglass seal on the back of the door is intact. Locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and the tool supplied, do not over tighten the nuts, see diagram 22. Keep the tool with these instructions for future use. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVE ...

  • Stovax 8542-P8542 - page 10

    10 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Packing Checklist Qty Description 1 Stove 1 Flue Blanking plate 1 Flue In fill plate 1 Coal set* 1 Flame Baffle* 1 Front Coal* 1 Fixing kit containing 1 Instruction Manual 2 Wood screws 2 Rawlplugs 1 Box spanner *Packed in appliance ModelCAT. Gas Gas Type Working Pressure NOX Class Aeration Injec ...

  • Stovax 8542-P8542 - page 11

    11 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1.1 The chimney or flue system must comply with the rules in force, and must be a minimum of 127mm in diameter. (5"). 1.2 The minimum height of the flue or chimney must be 3 metres (10ft). Any horizontal flue run from the rear outlet should not exceed 100mm from the back of the appliance. 1.3 The ...

  • Stovax 8542-P8542 - page 12

    off the gas supply, this indicates there is insufficient flue pull. If this occurs a minimum of 10 minutes should be allowed before trying to relight. Continued operation of this safety device means there may be a serious problem with the flue system and a qualified gas engineer must inspect. DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT IS SAFE T ...

  • Stovax 8542-P8542 - page 13

    13 There is a cutout in the RH rear leg to enable a direct straight connection to be made to the rear of the stove. See diagram 3. A gas soundness check must be completed up to the gas inlet connection. 4.2 Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening. If there is a definite flow into the chimney, ...

  • Stovax 8542-P8542 - page 14

    14 5.6 Place the remaining three round coals behind the centre row so that they touch the back panel, see diagram 9. 5.7 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, se ...

  • Stovax 8542-P8542 - page 15

    15 5.12 Place five small coals along the rear of the flame baffle, resting against the rear ledge, see diagram 15. 5.13 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, see ...

  • Stovax 8542-P8542 - page 16

    16 INSTALLATION INSTRUCTIONS INSTALLATION 5.17 Place three small coals at each end of the front coal so that they lean against the flame baffle and a further four large coals on the flame baffle, two at each end, see diagram 20. 518 Place six small coals along the rear of the flame baffle, resting against the rear ledge, see diagram 21. NOTE: ENSUR ...

  • Stovax 8542-P8542 - page 17

    17 INSTALLATION INSTRUCTIONS COMMISSIONING 1.1 Close all openable doors and windows in the room. Ignite the stove and operate on maximum for 10 minutes. Remove the plastic sight plug from the right-hand side of the stove. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening. Watc ...

  • Stovax 8542-P8542 - page 18

    18 IGNITION FUNCTIONAL CHECK 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark, clean the area. Operate the valve. Is there a spark? Consult Section 2 on page 4 and retry. Check alignment of pilot burner head. Change the ignition lead, see diagram 1, Servicing Requirements. Che ...

  • Stovax 8542-P8542 - page 19

    19 PILOT WILL NOT STAY LIT OR FIRE GOES OUT IN USE Ensure there is no debris around the pilot assembly, e.g. coal, soot etc. which could short the spark, clean the area. Problem is with the pipework or fittings which lead to the fire. Correct and retry. Is thermocouple connection good in back of valve? Replace oxypilot. Will pilot stay alight? Chan ...

  • Stovax 8542-P8542 - page 20

    20 2.3 Loosen main injector nut on airbox and disconnect from injector, see diagram 3, A. 2.4 Remove the 2 screws attaching burner to back of unit, see diagrams 4A & 4B. Carefully withdraw burner unit upwards and tilt to remove the burner through door opening. Remove the 2 screws holding the heat shield in place. Replace in reverse order checki ...

  • Stovax 8542-P8542 - page 21

    21 3.1 Remove the burner module as described in Servicing Section 2 above. Carefully cut the cable ties holding the thermocouple to the pilot pipe. Remove the HT lead from the electrode, undo the two retaining screws and remove the pilot. See diagram 5. 3.2 When replacing the pilot ensure the thermocouple follows its original route, i.e. along the ...

  • Stovax 8542-P8542 - page 22

    22 6.1 Turn the gas supply off at the isolation device. 6.2 Disconnect the 2x8mm and 1x4mm gas pipe fittings at the back of the gas valve and also disconnect the thermocouple, see diagram 9. 6.3 Undo the single screw that secures the left-hand side of the control cover, see diagram 10. 6.4 To release the right-hand side of the control cover, insert ...

  • Stovax 8542-P8542 - page 23

    23 8.1 Turn the gas supply off at the isolation device. Locate the main injector on the LH side of the airbox, undo the compression nut and pull the pipe clear of the injector body, see diagram 13A. 8.2 Rotate the injector until it is fully removed, and install the correct replacement injector. Reassemble and turn the gas supply on, check for leaks ...

  • Stovax 8542-P8542 - page 24

    24 SERVICING INSTRUCTIONS REPLACING PARTS 12. CONTROL UPGRADE Components Small Medium Large Stove Stove Stove NG LPG NG LPG NG LPG Pilot Unit PI0036 PI0037 PI0036 PI0037 PI0036 PI0037 Injector IN0001 IN0003 IN0045 IN0006 IN0046 IN0044 Aeration Plate ME1094 ME1071 ME1096 ME0834 ME1071 ME10095 Gas Valve GC0088K* GC0088K* GC0088K* Flue Sensor EL0001 E ...

  • Stovax 8542-P8542 - page 25

    25 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:........................................................................................ Dealer's Stamp/CORGI Registration Num ...

  • Stovax 8542-P8542 - page 26

    26 ...

  • Stovax 8542-P8542 - page 27

    27 ...

  • Stovax 8542-P8542 - page 28

    Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group ...

Fabricant Stovax Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilStovax 8542-P8542 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Stovax
- manuels d’utilisations 8542-P8542
- fiches produit Stovax
- dépliants
- ou étiquettes-énergie Stovax 8542-P8542
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Stovax 8542-P8542.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Stovax 8542-P8542, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Stovax 8542-P8542. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Stovax 8542-P8542.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Stovax 8542-P8542, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Stovax 8542-P8542 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Stovax 8542-P8542.

Le manuel d’utilisation complet Stovax, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Stovax 8542-P8542 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Stovax 8542-P8542, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lStovax 8542-P8542 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Stovax 8542-P8542 - qui devraient nous aider dans les premières étapes lors de l'utilisation Stovax 8542-P8542
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Stovax 8542-P8542
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Stovax 8542-P8542 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Stovax 8542-P8542?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Stovax 8542-P8542, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Stovax 8542-P8542 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)