    Save this manual for future reference WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 2

    2 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases. 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrical switch; do not use any p ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 3

    3 105273 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Product Identification Flame-Max ® Golden Oak Logs PRODUCT FEA TURES OPERATION This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney. Heat is generated by realistic, dancing yellow flames. This heater is designed for vent-free oper ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 4

    4 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code. NFPA 54/ANS Z223.1, Sec- tion 5.3, Air for Combustion and Ventilation. All spaces in homes fall into one of the three following ventilation classifications: 1. Unusually Tight Construction 2. Uncon ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 5

    5 105273 OWNER’S MANUAL DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the ro ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 6

    6 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® AIR FOR COMBUSTION AND VENTILA TION Continued Figure 3 - Ventilation Air from Outdoors Figure 2 - Ventilation Air from Inside Building Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Or Remove Door into Adjoining Room, Option ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 7

    7 105273 OWNER’S MANUAL WARNING: Never install the heater • in a bedroom or bathroom un- less installed as a vented ap- pliance (see page 10) • in a recreational vehicle • where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater • in high traffic areas • in windy ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 8

    8 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Minimum Noncombustible Material Clearances If Not Using Mantel Note: If using a mantel, proceed to If Using Mantel . If not using a mantel, follow the information below. You must have noncombustible material(s) above the fireplace opening. Noncombus- tible materials (such as slate, m ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 9

    9 105273 OWNER’S MANUAL INST ALLA TION Continued Figure 6 - Minimum Mantel Clearances Without Using Hood Figure 7 - Minimum Mantel Clearances When Using Hood Continued MANTEL CLEARANCES In addition to meeting noncombustible ma - terial clearances, you must also meet re- quired clearances between fireplace opening and mantel shelf. If you do not m ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 10

    10 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Area of Various Standard Round Flues Diameter (ins.) Area (sq. ins.) 5" 20 sq. inches 6" 29 sq. inches 7" 39 sq. inches 8" 51 sq. inches INSTALLING HEATER BASE ASSEMBLY WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adj ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 11

    11 105273 OWNER’S MANUAL Figure 11 - Attaching Flexible Gas Hose to Heater Figure 12 - Attaching Base Assembly to Fireplace Floor Fitting Flexible Gas Hose (if allowed by local codes) Masonry Screw Mounting Flanges INST ALLA TION Continued Installation Items Needed • hardware package (provided with heater) • approved flexible gas hose (not pr ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 12

    12 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® INST ALLA TION Continued CONNECTING TO GAS SUPPLY NOTICE: A qualified service per- son must connect heater to gas supply. Follow all local codes. Installation Items Needed Before installing heater, make sure you have the items listed below. • piping (check local codes) • sealant ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 13

    13 105273 OWNER’S MANUAL Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff valve (see Fig- ure 14). 2. Pressurize supply piping system by ei- ther using compressed air or opening main gas valve located on or near gas meter . 3 . Check all joints from gas meter to manual shutoff valve (see Figure 15). Apply mixture of liquid so ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 14

    14 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater. 1. Place one-piece log set on grate to fit as illustrated in Figure 16. Make sure middle section at bottom of log set is seated into "U"-shaped cutout in ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 15

    15 105273 OWNER’S MANUAL LIGHTING INSTRUCTIONS OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follo w ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 16

    16 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® Ignitor Electrode Pilot Burner Figure 19 - Pilot CAUTION: Do not try to adjust heating levels by using the manual shutoff valve. WARNING: Make sure the selector switch is in the OFF po- sition when you are away from home for long periods of time. Heater will come on automati- cally ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 17

    17 105273 OWNER’S MANUAL ON OFF REMOTE O F F P I L O T O N L O I H TEMP ST ATUS HI LO MAN ON AUT O OFF Increases Room Temperature Decreases Room Temperature Turns Burner On and Off Shows Current Operation Mode Shows Temperature Setting Allows Burner to be Turned On and Off with the Hand- Held Remote Unit. Figure 21 - Thermostat Hand-Held Remote C ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 18

    18 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® CLEANING AND MAINTENANCE WARNING: Turn off heater and let cool before cleaning. CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service perso ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 19

    19 105273 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit. POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 20

    20 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or odor during initial operation Moisture/condensation noticed on windows Heater produces a whistling noise when burner is lit White powder residue ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 21

    21 105273 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, cal ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 22

    22 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® ILLUSTRA TED PA R T S BREAKDOWN FLAME-MAX ® GOLDEN OAK LOG MODELS VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR 4 13 13 14 22 13 8 18 7 6 9 1 12 5 16 15 17 3 11 2 10 24 23 23 19 19 20 21 26 25 O F F P I L O T O N H I L O O F F P I L O T O N H I L O * Note: The Golden Oak Log (104254-01 ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 23

    23 105273 OWNER’S MANUAL P ARTS LIST VYD18NRA, VYD24NRA, VYD30NRA, AND VYD36NR This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 24 of this manual. KEY PART NUMBER FOR NO. VYD18NRA VYD24NRA VYD30NRA VYD36NR DESCRIPTION QTY. 1 105268-01 105268-02 105268-03 ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 24

    24 105273 UNVENTED NA TURAL GAS LOG HEA TER V ANGUARD FLAME MAX ® REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product. If they can’t supply original replacement part(s), call DESA International? ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 25

    25 105273 OWNER’S MANUAL ACCESSORIES Purchase these heater accessories from your local dealer. If they can not supply these accessories, call DESA International’s Parts Department at 1-800-972-7879 for referral information. You can also write to the ad- dress listed on the back page of this manual. DAMPER CLAMP - GA6080 (Not Shown) Permanently ...

  • Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - page 26

    LIMITED WARRANTY VENT-FREE NATURAL GAS LOG HEATERS DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions. To make a claim under this ...

Fabricant Vanguard Heating Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vanguard Heating
- manuels d’utilisations UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER
- fiches produit Vanguard Heating
- dépliants
- ou étiquettes-énergie Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER.

Manuel d’utilisation complet de l’appareil Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER.

Le manuel d’utilisation complet Vanguard Heating, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER - qui devraient nous aider dans les premières étapes lors de l'utilisation Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vanguard Heating UNVENTED (VENT-FREE) NATURAL GAS LOG HEATER il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)