  • Allied Air Enterprises 15) - page 1

    506248-01 Page 1 of 14 Issue 0902 Save these instructions for future reference INST ALLA TION AND MAINTENANCE INSTRUCTIONS (2,4)PHP(13,15) Series Self-Contained Heat Pump Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult ...

  • Allied Air Enterprises 15) - page 2

    Page 2 of 14 506248-01 Issue 0902 INST ALLA TION These instructions explain the recommended method of installation of the PHP heat pump unit and associated electrical wiring. This unit is designed and approved for use as a self- contained air-to-air outdoor heat pump system. The units are factory equipped with a transformer and blower control for a ...

  • Allied Air Enterprises 15) - page 3

    506248-01 Page 3 of 14 Issue 0902 Using Accessory Lif t Kit Figure 1 Units may also be moved or lifted with a forklif t while still in the factory-supplied packaging. The lengths of the forks of the forklif t must be a minimum of 42". Roof Curb Installation If a roof curb is used, follow the manufacturer’s Installation Instructions and be su ...

  • Allied Air Enterprises 15) - page 4

    Page 4 of 14 506248-01 Issue 0902 Ductwork Ductwork should be designed and sized according to the methods in Manual Q of the Air Conditioning Contractors of America (ACCA). A closed return duct system shall be used. This shall not preclude use of economizers or outdoor fresh air intake. It is recommended that supply and return duct connections at t ...

  • Allied Air Enterprises 15) - page 5

    506248-01 Page 5 of 14 Issue 0902 Power supply to the unit must comply with all applicable codes and the National Electical Code (NEC) or Canadian Electrical Code (CEC). A fused disconnect switch should be field provided for the unit. The switch must be sep arate from all other circuit s. Figure 5 Electrical Access Heater P ow er Entr y Thermostat ...

  • Allied Air Enterprises 15) - page 6

    Page 6 of 14 506248-01 Issue 0902 Thermostat The room thermostat should be located on an inside wall where it will not be subject to draft s, sun exposure, or heat from electrical fixtures or appliances. Follow the manufacturer ’ s instructions enclosed with thermostat for general installation procedure. Color-coded insulated wires (#18 A WG) sho ...

  • Allied Air Enterprises 15) - page 7

    506248-01 Page 7 of 14 Issue 0902 OPERA TION Sequence of Operation Cooling When the thermostat is in the cooling mode, the O circuit is powered which energizes the reversing valve. Upon cooling demand, the thermostat closes circuit R and Y . Closing R and Y closes the unit cont actor , starting the compressor and outdoor fan. The thermostat automat ...

  • Allied Air Enterprises 15) - page 8

    Page 8 of 14 506248-01 Issue 0902 jumper is not in place, the control defaults to a 90-minute defrost interval. The maximum defrost period is 14 minutes and cannot be adjusted. A test option is provided for troubleshooting. The test mode may be started any time the unit is in the heating mode and the defrost thermostat is closed or jumpered. If the ...

  • Allied Air Enterprises 15) - page 9

    506248-01 Page 9 of 14 Issue 0902 There is no blower “on” delay after a call for heating or cooling. Blower “off” delay is 90 seconds af ter the thermostat is satisfied. V ariable Speed Motor Units equipped with a variable speed circulation air blower motor will deliver a constant airflow within a wide range of external static pressures. Ot ...

  • Allied Air Enterprises 15) - page 10

    Page 10 of 14 506248-01 Issue 0902 Owner Record Model # _________________________________ Serial # _________________________________ Installation Date ___________________________ Installed by: Dealer __________________________________ Address _________________________________ T elephone # ______________________________ License # ___________________ ...

  • Allied Air Enterprises 15) - page 11

    506248-01 Page 11 of 14 Issue 0902 Figure 9 208/230V -1-60 G W1 CR O BLK RED YEL RED CONT ACT OR THERMOST A T HIGH PRESSURE SWITCH (IF USED) L1 T1 T2 L2 C H F CONDENSER F AN MO TOR COMPRESSOR CONT ACT OR COMPRESSOR CONT ACT OR DUAL CAP ACIT OR COMPRESSOR TRANSFORMER C S R WHT L2 L1 BLK BRN PUR RED RED BLK 208V 240V 24V INDOOR BLOWER MOTO R S4 S1 K1 ...

  • Allied Air Enterprises 15) - page 12

    Page 12 of 14 506248-01 Issue 0902 Connection Diagram Single Phase – V ariable Speed Motor P/N 48374-001 Figure 10 DIAGNOSTIC DISPLA Y Note: Because the pressure switches are monitored only when "Y1" (Input) is activ e, the code for pressure s witch open will not be seen when "Y1" is off . Instead, the “Normal Operation" ...

  • Allied Air Enterprises 15) - page 13

    506248-01 Page 13 of 14 Issue 0902 ALLIED AIR ENTERPRISES EQUIPMENT LIMITED W ARRANTY APPLIES IN U.S.A. AND CANADA ONL Y F AILURE T O MAINT AIN YOUR EQUIPMENT WILL VOID THIS W ARRANTY COVERED EQUIPMENT The following Allied Air Enterprises heating and cooling equipment is covered by the Limited Warranty , Condensing Units: 2SCU13, 4SCU13, 4SCU14, 4S ...

  • Allied Air Enterprises 15) - page 14

    Page 14 of 14 506248-01 Issue 0902 Allied Air Enterprises Inc. (“Allied Air”) provides its air conditioning and heating product s with a S tandard Limited Parts W a rranty for five (5) years. This additional 5-Y ear Limited Extended Parts W arranty is in addition to and is intended to supplement Allied Air ’s St andard Limited Parts W arranty ...

Fabricant Allied Air Enterprises Catégorie Heat Pump

Les documents que nous recevons du fabricant de l'appareilAllied Air Enterprises 15) peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Allied Air Enterprises
- manuels d’utilisations 15)
- fiches produit Allied Air Enterprises
- dépliants
- ou étiquettes-énergie Allied Air Enterprises 15)
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Allied Air Enterprises 15).

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Allied Air Enterprises 15), manuels d’entretien, brefs manuels ou manuels de l’utilisateur Allied Air Enterprises 15). Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Allied Air Enterprises 15).

Manuel d’utilisation complet de l’appareil Allied Air Enterprises 15), quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Allied Air Enterprises 15) par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Allied Air Enterprises 15).

Le manuel d’utilisation complet Allied Air Enterprises, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Allied Air Enterprises 15) - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Allied Air Enterprises 15), FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAllied Air Enterprises 15) qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Allied Air Enterprises 15) - qui devraient nous aider dans les premières étapes lors de l'utilisation Allied Air Enterprises 15)
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Allied Air Enterprises 15)
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Allied Air Enterprises 15) dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Allied Air Enterprises 15)?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Allied Air Enterprises 15), avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Allied Air Enterprises 15) il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)