    FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 360101-XT G-B-0508 TECHNICAL GUIDE ® DESCRIPTION These packaged cooling air conditi oners are designed for outdoor installation. Only ut i lity and duct connections are required at the point of installation. Field-installed electric he ater accessories are availabl e to provide ele ...

  • York D2EB030 - page 2

    360101-XTG-B-0508 2 Johnson Controls Unitary Products TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 STANDARD FEATURES / BENEFITS . . . . . . . . . . . . . . . . . 1 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . . 3 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . ...

  • York D2EB030 - page 3

    360101-XTG-B-0508 Johnson Controls Unitary Products 3 STANDARD FEATURES/BENEFITS (CONT.) UTILITY CONNECTIONS MADE EASY - Electri c al utility knockouts are provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplie d and field installed electrical di ...

  • York D2EB030 - page 4

    360101-XTG-B-0508 4 Johnson Controls Unitary Products operation. Independe nt blade desig n insures p roper control and less than 1% leak rate. Includes hood an d me sh bird screen filter integrated into the ho od, dry bulb senso r and relie f damper. Separate field a ccessories of single enthalpy and dual enthalpy are also available. SINGLE ENTHAL ...

  • York D2EB030 - page 5

    360101-XTG-B-0508 Johnson Controls Unitary Products 5 EER = Energy Efficiency Ratio - the total cooling output in BTU's during a nor mal annual usage period for cooling divided by th e tota l electric power input in watt-hours during the same period. T ABLE 1: PHYSICAL DA T A MODELS DEB 030 036 042 048 060 EVAPORATOR BLOWER CENTRIFUGAL BLOWER ...

  • York D2EB030 - page 6

    360101-XTG-B-0508 6 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 3: COOLING CAP ACITIES - 2 -1/2 T ON (DEB030) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 750 CFM 875 CFM 1,000 CFM 1,125 CFM 1,250 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 32. ...

  • York D2EB030 - page 7

    360101-XTG-B-0508 Johnson Controls Unitary Products 7 ALL SENSIBLE CAPACITIES T ABLE 4: COOLING CAP ACITIES - 3 T ON (DEB036) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 900 CFM 1,050 1,200 1,350 1,500 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 34.7 32.3 28.5 28.4 36 ...

  • York D2EB030 - page 8

    360101-XTG-B-0508 8 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 5: COOLING CAP ACITIES - 3 -1/2 T ON (DEB042) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1,050 CFM 1,225 1,400 1,575 1,750 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 40.7 39.0 36.5 ...

  • York D2EB030 - page 9

    360101-XTG-B-0508 Johnson Controls Unitary Products 9 ALL SENSIBLE CAPACITIES T ABLE 6: COOLING CAP ACITIES - 4 T ON (DEB048) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 49.2 46.1 ...

  • York D2EB030 - page 10

    360101-XTG-B-0508 10 Johnson Controls Unitary Products ALL SENSIBLE CAPACITIES T ABLE 7: COOLING CAP ACITIES - 5 T ON (DEB060) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1200 CFM 1400 CFM 1600 CFM 1800 CFM 2000 CFM WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 6 2 57 72 67 62 57 72 67 62 57 72 67 6 2 57 85 °F Net Cap MBH 65.2 59. ...

  • York D2EB030 - page 11

    360101-XTG-B-0508 Johnson Controls Unitary Products 11 Note: 1. Deduct these resistance values from t he available external static pressure shown in th e respective Blower Performance T able. 2. The pressure thru the economizer is greater for 100 % outdoor air then for 100% return air. If the resistance of the return a ir duct system is less then 0 ...

  • York D2EB030 - page 12

    360101-XTG-B-0508 12 Johnson Controls Unitary Products T ABLE 10: ELECTRICAL DA T A MODEL DEB POWER SUPPL Y VOL T AGE LIMIT A TI ONS 1 COMPRESSOR COND. FA N MOTOR, FLA SUPPL Y AIR BLOWER MOTOR FLA MINIMUM CIRCUIT AMP ACITY MAX. FUSE 2 SIZE, AMPS MAX. HACR BREAKER SIZE, AMPS UNIT POWER FA C T O R TRANSFORMER SIZE (V A) MIN. MAX. RLA LRA 30 208/230 - ...

  • York D2EB030 - page 13

    360101-XTG-B-0508 Johnson Controls Unitary Products 13 * = KW listed is for 240 volts, use table on previous p age for 208 or 230 volts. ** = KW listed is for 480 volts, us e table on previous page for 460 volt s. *** = KW listed is for 600 volts, use table on previous page for 575 volts. 042 208/230-3-60 11.5 88.0 1.1 3.5 2NH04501025 1 7.5/10.0* 2 ...

  • York D2EB030 - page 14

    360101-XTG-B-0508 14 Johnson Controls Unitary Products FIGURE 3 - UNIT DIMENSIONS HIGH VOL TAGE CONN. “ x " DIA. KNOCKOUT 6 DRAIN “ NPTI CONDENSA TE LOW VOL TAGE CONN. “ DIA. KNOCKOUT FRONT CONDENSER COIL 15 4 BACK SIDE RETURN AIR OPENING SIDE SUPPL Y AIR OPENING BOTTOM RETURN AIR OPENING 15 2 1 1 1 15 BOTTOM SUPPL Y AIR OPENING 2 LOW VO ...

  • York D2EB030 - page 15

    360101-XTG-B-0508 Johnson Controls Unitary Products 15 FIGURE 4 - CENTER OF GRAVITY T ABLE 12: UNIT WEIGHTS Unit Size Sh ipping Weight Operating Weight Corner Weights Economizer (lbs.) Roof Curb (lbs.) ABC D 030 333 328 85 81 82 86 40 8" - 70 14" - 75 036 338 333 91 80 78 88 042 347 342 94 83 80 91 048 368 363 92 88 92 97 060 376 371 105 ...

  • York D2EB030 - page 16

    360101-XTG-B-0508 16 Johnson Controls Unitary Products TYPICAL APPLICATIONS FIGURE 5 - TYPICAL SLAB ON GROUND INSTALLATION FIGURE 6 - TYPICAL ROOF CURB INSTALLATION TO POWER SUPPL Y SUPPL Y AIR DUCT RETURN AIR DUCT FIELD SUPPLIED DISCONNECT SWITCH LOCA TED TO REAR OF UNIT CONTROL WIRING TO INDOOR THERMOST A T SLAB ON GROUND INST ALLATION ROOF CURB ...

  • York D2EB030 - page 17

    360101-XTG-B-0508 Johnson Controls Unitary Products 17 FIGURE 7 - ROOF CURB DIMENSIONS (8 ” Roof curb al so available) FIGURE 8 - ROOF CURB APPLICATION FRONT 1 1 WOOD NAILER 4 INSULA TED P ANELS 22 14 OPENING FOR RETURN AIR DUCT OPENING FOR SUPPL Y AIR DUCT RECOMMENDED DUCT SIZE SUPPL Y AIR DUCT " x " RETURN AIR DUCT " x " UNI ...

  • York D2EB030 - page 18

    360101-XTG-B-0508 18 Johnson Controls Unitary Products FIGURE 9 - TYPICAL WIRING DIAGRAM ( 208/230-1-60 POWER SUPPLY) DEB MODEL S 15695BASH0301 SEE DET AIL "A" T2 M1 - 2 DET AIL "A" BLK BLK CCH L1 T1 OPTIONAL CCH S / P CONFIGURA TION BLK BLK CCH L1 D / P CONFIGURA TION L 2 L 2 ...

  • York D2EB030 - page 19

    360101-XTG-B-0508 Johnson Controls Unitary Products 19 TYPICAL WIRING DIAGRAM NOTES T YPICAL WIRING DIAGRAM LEGEND FIGURE 10 -TYPIC A L WI RI NG DIAGRAM (208/230-3-60 POWER SUPPLY) DEB MODELS - 6 - F 9 ( N O T USED ) - -- -- 2 - M 3 , 230V C O I L ...

  • York D2EB030 - page 20

    360101-XTG-B-0508 20 Johnson Controls Unitary Products FIGURE 11 -TYPICAL WIRING DIAGRAM (460-3-60 AND 5 75-3- 60 POWER SUPPLY) DEB MODELS 2 ...

  • York D2EB030 - page 21

    360101-XTG-B-0508 Johnson Controls Unitary Products 21 MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory-assembl ed, single packaged, Electric Cooling units, desi gned for outdo or mounted installation . They shall have built in, equal size, field convertibl e duct connections for down discharge supply/return or horizontal discha ...

  • York D2EB030 - page 22

    360101-XTG-B-0508 22 Johnson Controls Unitary Products b. Controls shall be moun ted in a large co ntrol box with tilt- out, hinged access door, allowing easy acce ss for trouble shooting and mainte nance without affecting the no rmal system operation pressures. c. Unit shall have large, easily removable panels, covering electrical controls an d co ...

  • York D2EB030 - page 23

    360101-XTG-B-0508 Johnson Controls Unitary Products 23 ...

  • York D2EB030 - page 24

    Subject to change without notice. Print ed in U. S.A. 360101-XTG-B-0508 Copyright © 2008 by Johnson Controls, In c. All rights reserved. Supersedes: 360101- XTG-A-0108 Johnson Contr ols Unitary Products 5005 York Drive Norman, OK 73069 ...

Fabricant York Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilYork D2EB030 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques York
- manuels d’utilisations D2EB030
- fiches produit York
- dépliants
- ou étiquettes-énergie York D2EB030
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation York D2EB030.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation York D2EB030, manuels d’entretien, brefs manuels ou manuels de l’utilisateur York D2EB030. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit York D2EB030.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil York D2EB030, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser York D2EB030 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs York D2EB030.

Le manuel d’utilisation complet York, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel York D2EB030 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières York D2EB030, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lYork D2EB030 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil York D2EB030 - qui devraient nous aider dans les premières étapes lors de l'utilisation York D2EB030
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de York D2EB030
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service York D2EB030 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de York D2EB030?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec York D2EB030, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec York D2EB030 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)