Manuel d’utilisation Quantum 9412/9112 A

31 pages 0.07 mb
Télécharger

Aller à la page of 31

Summary
  • Quantum 9412/9112 A - page 1

    1 1 INTRODUCTION This manual is designed to help you quickly and easily learn to use your Quantum Compo s ers Model 9412/9412A pulse generator. Rather than the usual array of knobs and switches, the 9412/9412A uses a menu - driven user interface with "on - line" he lp -- once you learn the basics of operating your 9412/9412A, you may neve ...

  • Quantum 9412/9112 A - page 2

    2 Custom Modifications The 9412/9412A is microprocessor - controlled and employs a flexible and expandable user - interface. New features and operating modes often can be added, without hardware modif i- cations, by merely modifying the software contained inside the 9412/9412A. Most modific a- tions can be made for a very modest charge -- conta ct ...

  • Quantum 9412/9112 A - page 3

    3 6. Never work alone. Someone should always be nearby to render aid if necessary. Training in CPR first aid is highly recommended. ...

  • Quantum 9412/9112 A - page 4

    4 ...

  • Quantum 9412/9112 A - page 5

    5 1 Item Button ...

  • Quantum 9412/9112 A - page 6

    6 1 CONTROLS AND CONNECT ORS This chapter explains the function of each control and connector on the 9412/9412A. Front Panel The front panel contains the most frequently used controls and connectors. Display The 9412/9412A features a backlit liquid crystal display, which displays menu selections and settings. The left half of the display shows the ...

  • Quantum 9412/9112 A - page 7

    7 Left Button (help) For numeric items, this button is used to select which digit in a numeric entry is selected for editing. For other items or when the left most digit is already selected for numeric i tems, pressing and holding this button down displays a brief description of the current item. Right Button (range) For numeric items, this button ...

  • Quantum 9412/9112 A - page 8

    8 T2 Channel 2 output -- designed specifically for use as a solid - stat e laser Q - switch trigger and has all the capabilities of the other output channels, including several special modes which a f- fect only the output of Channel 2. Ext/Gate External Trigger or Gate signal input -- used as either an external signal to trigger the gener a- tion ...

  • Quantum 9412/9112 A - page 9

    9 ...

  • Quantum 9412/9112 A - page 10

    10 1 ...

  • Quantum 9412/9112 A - page 11

    11 1 ...

  • Quantum 9412/9112 A - page 12

    12 1 OPERATING INSTRUCTIO NS This chapter presents detailed instructions on the operation of the 9412/9412A. Overview The 9412/9412A uses a single - line L CD to display menu selections. The front panel keys are used to "navigate" through sets of menus to set various options and control the pulse ge n era- tor. Some keys are only active a ...

  • Quantum 9412/9112 A - page 13

    13 Main Menu The Main Menu consists of a set of menu selections used to set the operating mode, time p e- riod and frequency of the 9412/9412A. MODE - Pulse Modes There are five (5) different Pulse modes available. Continuous Mode While in Continuous mode, the 9412/9412A will generate pulses at the rate set by the inte r nal To Period as set in the ...

  • Quantum 9412/9112 A - page 14

    14 Duty Cycle The Duty Cycle mode is similar to Continuous mode in that a continuous stream of pulses is output. The exception is the outputs are only active for a set number of seconds ( DC:On menu), then disabled for another set time period ( DC:Off menu) before being re - enabled. This cycle is repeated for a set number of times ( CYCLES menu), ...

  • Quantum 9412/9112 A - page 15

    15 ToPer - To Period Except when in External Trigger or Single Shot mode, all pulse outputs are based on an i n te r- nal timer called To. This menu is used to select the rate at which To runs by selecting the time period in microseconds between timer pulses. When in Continuous, Burst, or Duty C y cle mode, pulses are out put at the rate determined ...

  • Quantum 9412/9112 A - page 16

    16 When set to Positive , the output will initially be at 0 Volts. When active, will go high for the specified pulse width time, after which it will return to 0. The voltage level while high w ill d e- pend upon the load and the setting of the output voltage adjustment on the back panel. If set to Negative , the output will normally be at the high ...

  • Quantum 9412/9112 A - page 17

    17 T2:Wait The output of Channel 2 can be delayed for a number of pulses. This menu is used to set the number of pulses that must occur on the other channels before the output o f Channel 2 is e n- abled. This is particularly useful when using Channel 2 as a Q - switch trigger, as it allows the laser to thermally stabilize before activa t ing the Q ...

  • Quantum 9412/9112 A - page 18

    18 RECALL Configuration Recalls a previously stored configuration from the specified memory location. To rec all a configuration use the Up and Down arrow keys to select the memory location number and press the Left or Right arrow key. You will be prompted to press the key to verify that you want to overwrite the active configuration. If you press ...

  • Quantum 9412/9112 A - page 19

    19 ...

  • Quantum 9412/9112 A - page 20

    20 1 5 4 3 2 1 9 8 7 6 ...

  • Quantum 9412/9112 A - page 21

    21 1 COMPUTER INTERFACE The 9412/9412A comes standard with an RS232 serial interface. All menu settings can be set and retrieved over the computer interface using a simple command language. Serial (RS232) Pinout The serial port is located on the back of the 9412/9412A and uses a 9 - pin D - type connector with the following pinout (as viewed from t ...

  • Quantum 9412/9112 A - page 22

    22 P P CR is a carriage return character (ASCII value 13). With echo enabled, all characters sent will be echoed back to the sender. Unidentified commands and most out of range conditions result in the pulse generator igno r ing the command. If the command is properly identified, the pulse generator returns an ok fo l- lo wed by a carriage return a ...

  • Quantum 9412/9112 A - page 23

    23 Communication Protocol Communication parameters are set at 9600 baud, 8 bits, parity = none, and 1 stop bit. To help establish RS232 communications, the pulse generator emits the characters QC a p proximately every 200 ms after power up and until the 9412/9412A receives a $ . ...

  • Quantum 9412/9112 A - page 24

    24 Command List The following table summarizes all the commands. Note: The name of each command is identical to how it appears on the dis play of the 9412/9412A. ...

  • Quantum 9412/9112 A - page 25

    25 9412/9412A Communication Commands Command Name Parameters Description MODE 0 = Continuous mode 1 = Burst mode 2 = Duty Cycle mode 3 = Single Shot mode 4 = External Trigger mode Sets the pulse generator mode. GATE 0 = off 1 = active low 2 = active high Enables the external trigger input to function as a gate controlling all outputs. Cannot be use ...

  • Quantum 9412/9112 A - page 26

    26 9412/9412A Communication Commands RECALL 0 - 4 (9412) 0 - 8 (9412A) Recall a stored configuration. STORE 1 - 4 (9412) 1 - 8 (9412A) Store a configuration. SHOTS (9412A Only) 0 = Reset to zero Resets shot counter. SHOT ? will return the number of shots. ECHO 0 = Disable 1 = Enable Enables/Disables the RS232 echo. The result string is always sent ...

  • Quantum 9412/9112 A - page 27

    27 1 SPECIFICATIONS DELAYS P CHANNELS Two (2) independent outputs, with digitally controlled delay and pulsewidth. P DELAY 0 to 99.999999 sec P PULSEWIDTH 10 µ s to 99.999999 sec P RESOLUTION 1 µ s P ACCURACY 100 ns + .0002 x delay P TIMEBASE 8 MHz, 50 PPM crystal oscillator P RMS JITTER 50 ns + .0002 x period, 200 ns max P TRIG DELAY Ext Trig to ...

  • Quantum 9412/9112 A - page 28

    28 OUTPUTS (T1,T2) P IM PEDANCE 50 Ω P SLEW RATE > .2 V/ns P OVERSHOOT < 100 mV + 10% of pulse amplitude P AMPLITUDE 1 - 10V into 50 Ω load 2 - 20V into high impedance load manually adjusted, all outputs at same level P PEAK CURRENT 400 mA per channel P AVERAGE CURRENT 200 mA average (total for all channels) COMPUTER INTERFACE P RS232 960 ...

  • Quantum 9412/9112 A - page 29

    29 1 MAINTENANCE Except for fuse replacement, the 9412/9412A should require no maintenance. Replacing the Fuse The fuse is mounted on the circuit board located inside the 9412/9412A. Remove the top cover to access and follow the instructions given below to replace the fuse: 1. Unplug the 9412/9412A from power source and remove power cord from the b ...

  • Quantum 9412/9112 A - page 30

    30 ...

  • Quantum 9412/9112 A - page 31

    31 1 CUSTOM FEATURES None. ...

Fabricant Quantum Catégorie Medical Alarms

Les documents que nous recevons du fabricant de l'appareilQuantum 9412/9112 A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Quantum
- manuels d’utilisations 9412/9112 A
- fiches produit Quantum
- dépliants
- ou étiquettes-énergie Quantum 9412/9112 A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Quantum 9412/9112 A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Quantum 9412/9112 A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Quantum 9412/9112 A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Quantum 9412/9112 A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Quantum 9412/9112 A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Quantum 9412/9112 A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Quantum 9412/9112 A.

Le manuel d’utilisation complet Quantum, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Quantum 9412/9112 A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Quantum 9412/9112 A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lQuantum 9412/9112 A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Quantum 9412/9112 A - qui devraient nous aider dans les premières étapes lors de l'utilisation Quantum 9412/9112 A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Quantum 9412/9112 A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Quantum 9412/9112 A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Quantum 9412/9112 A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Quantum 9412/9112 A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Quantum 9412/9112 A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)