Manuel d’utilisation White Rodgers 1F85-0477

12 pages 1.29 mb
Télécharger

Aller à la page of 12

Summary
  • White Rodgers 1F85-0477 - page 1

    1 Blue 4” Univ er sal T her mostat with Automa tic Heat/Cool Changeo v er Option Single Stage, Multi-Stage or Heat Pump Installation and Operating Instructions for Model: F AILURE T O READ AND FOLLO W ALL INSTRUCTIONS CAREFULL Y BEFORE INST ALLING OR OPERA TING THIS CONTROL COULD CA USE PERSONAL INJUR Y AND/OR PROPER TY D AMAGE. Save these instru ...

  • White Rodgers 1F85-0477 - page 2

    2 INST ALLA TION Thermostat installation and all components of the control system shall conf orm to Class II circuits per the NEC code. W ARNING ! Remove Old Thermostat A standard heat/cool thermostat consists of three basic par ts: 1. The cov er , which may be either a snap-on or hinge type . 2. The base, which is remo ved b y loosening all captiv ...

  • White Rodgers 1F85-0477 - page 3

    3 Single Stage 1 (SS1) Multi- Stage 2 (MS2) O Energized Constantly in Cool Mode B Energized Constantly in Heat, Off, Emergency Mode No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional* 24 V olt (Com- ...

  • White Rodgers 1F85-0477 - page 4

    4 WIRING DIA GRAMS Figure 5 – Single Stage or Multi-Stage System (No Heat Pump) with T wo T ransformer s Single Stage 1 (SS1) Multi- Stage 2 (MS2) No Output Cool Mode 2nd Stage Cool Mode 1st Stage Blower/ Circulator Fan Energized on Call for Cool (and Heat if configured for Electric Heat) No Output Heat Mode 2nd Stage Heat Mode 1st Stage Optional ...

  • White Rodgers 1F85-0477 - page 5

    5 11 10 9 1 8 7 6 5 4 3 2 12 Month Change Filter Call For Service Save T emp Hold P Date Set Set Schedule SYSTEM F AN Y ear R u n Hold Heat Mo T u We Th Fr Sa Su System On + 2 Heat Pump A uto Sched Cool Savings Em Auto A uto Cool Of f Time On Menu Set Mo P SYSTEM Heat FAN Auto Menu Room T emperature Setting T emperature System Indicator Fa n Indica ...

  • White Rodgers 1F85-0477 - page 6

    6 INST ALLER/CONFIGURA TION MENU With thermostat in Heat, Cool or Auto , in nor mal operation, press the Menu button f or at least 5 seconds. The displa y will show item #1 in the table belo w . Press Menu button to adv ance to the ne xt menu item. Press or to change an item option. INST ALLER/CONFIGURA TION MENU MENU REF . HP SS PRESS BUTT ON DISP ...

  • White Rodgers 1F85-0477 - page 7

    7 INST ALLER/CONFIGURA TION MENU 1) This control can be confi gured for: MS 2 – Multi-Stage System (no heat pump) HP 1 – Heat Pump with one stage of compressor HP 2 – Heat Pump with two stage compressor or two compressor system, Gas or Electric backup SS 1 – Single Stage System 2) GAS or Electric (ELE) fan operation. If the heating sys- te ...

  • White Rodgers 1F85-0477 - page 8

    8 OPERA TING Y OUR THERMOST A T Choose the Fan Setting (A uto or On) Press the F AN b utton to Auto or On. F an Auto is the most commonly selected setting and runs the f an only when the heating or cooling system is on. F an On r uns the f an continuously f or increased air circulation or to allow additional air cleaning. Choose the System Setting ...

  • White Rodgers 1F85-0477 - page 9

    9 The programmab le thermostats are programmed with the energy saving settings sho wn in the table belo w f or all days of the week. If this program suits y our needs, simply set the thermostat clock and press the R UN button. The table below sho ws the f actor y set heating and cooling schedule f or all days of the w eek. W ake Up (P eriod 1) Leav ...

  • White Rodgers 1F85-0477 - page 10

    10 W orksheet f or Re-Programming 7 Da y and 5+1+1 Day Program Cooling Program W ake Up (P eriod 1) Leave For W ork (P eriod 2) Return Home (P eriod 3) Go T o Bed (P eriod 4) MON 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F TUE WED THU FRI SA T 6:00 AM 75°F 8:00 AM 83°F 5:00 PM 75°F 10:00 PM 78°F SUN 6:00 AM 75°F 8:00 AM 83°F 5:00 ...

  • White Rodgers 1F85-0477 - page 11

    11 Symptom Possib le Cause Correction Action No Heat/No Cool/No Fan (common problems) 1. Blown fuse or tripped circuit breaker . 2. Fur nace power s witch to OFF . 3. Fur nace blo wer compar tment door or panel loose or not properly installed. 4. Loose connection to ther mostat or system. Replace fuse or reset breaker . T urn switch to ON. Replace ...

  • White Rodgers 1F85-0477 - page 12

    12 www .white-rodger s.com HOMEO WNER HELP LINE: 1-800-284-2925 White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and ser vice mark of Emerson Electric Co. ...

Fabricant White Rodgers Catégorie Thermostat

Les documents que nous recevons du fabricant de l'appareilWhite Rodgers 1F85-0477 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques White Rodgers
- manuels d’utilisations 1F85-0477
- fiches produit White Rodgers
- dépliants
- ou étiquettes-énergie White Rodgers 1F85-0477
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation White Rodgers 1F85-0477.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation White Rodgers 1F85-0477, manuels d’entretien, brefs manuels ou manuels de l’utilisateur White Rodgers 1F85-0477. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit White Rodgers 1F85-0477.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil White Rodgers 1F85-0477, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser White Rodgers 1F85-0477 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs White Rodgers 1F85-0477.

Le manuel d’utilisation complet White Rodgers, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel White Rodgers 1F85-0477 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières White Rodgers 1F85-0477, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWhite Rodgers 1F85-0477 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil White Rodgers 1F85-0477 - qui devraient nous aider dans les premières étapes lors de l'utilisation White Rodgers 1F85-0477
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de White Rodgers 1F85-0477
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service White Rodgers 1F85-0477 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de White Rodgers 1F85-0477?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec White Rodgers 1F85-0477, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec White Rodgers 1F85-0477 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)