Manuel d’utilisation FMI F48H(I)(R)A

20 pages 1.95 mb
Télécharger

Aller à la page of 20

Summary
  • FMI F48H(I)(R)A - page 1

    IF FIREPLACE IS TO BE INST ALLED DIRECTL Y ON ANY COMBUSTIBLE MA TERIAL, A HEARTH SP ACER IS REQUIRED. SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your ...

  • FMI F48H(I)(R)A - page 2

    www .fmipr oducts.com 124386-01A 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury , property damage or loss of life. Refer to this manual for assis- tance or additional information. Consult a qualied installer or local distributor . T ABLE OF CONTENTS Safety .................................... ...

  • FMI F48H(I)(R)A - page 3

    www .fmipr oducts.com 124386-01A 3 SPECIFICA TIONS MODELS F48H(I)(R)A AND VF48H(I)(R)A SQUARE CHASE-TOP TERMIN AT ION ROUND TOP TERMIN AT ION 33.5" 48" 60.625" 42.375" 30.31" PLANT A TION FIREPLACE WITH HEARTH SP ACER (REQUIRED FOR COMBUSTIBLE FLOORS) 24" 14.375" 30" 0.625" 15.625" 8.875" 7.625 ...

  • FMI F48H(I)(R)A - page 4

    www .fmipr oducts.com 124386-01A 4 INST ALLA TION SELECTING FIREPLACE LOCA TION T o determine the safest and most efcient location for the replace, you must take into consideration the following guidelines: 1. The location must allow for proper clear - ances (see Figures 1 and 2). 2. Consider a location where the replace will not be affect ...

  • FMI F48H(I)(R)A - page 5

    www .fmipr oducts.com 124386-01A 5 HEARTH EXTENSION A hearth extension projecting a minimum of 20" in front of and a minimum of 12" beyond each side of the replace opening is required to protect combustible floor construction in front of the replace. Fabricate a hearth extension using a material which meets the following specicat ...

  • FMI F48H(I)(R)A - page 6

    www .fmipr oducts.com 124386-01A 6 Figure 6 - Lineal Gain LINEAL GAIN P ART NO. DESCRIPTION GAIN (IN) 48" Plantation Fireplace 66 1 / 2 " 12-12DM 12-12HT Pipe Section 10 5 / 8 " 18-12DM 18-12HT Pipe Section 16 5 / 8 " 24-12DM 24-12HT Pipe Section 23 5 / 8 " 36-12DM 36-12HT Pipe Section 34 5 / 8 " 48-12DM 48-12HT Pipe S ...

  • FMI F48H(I)(R)A - page 7

    www .fmipr oducts.com 124386-01A 7 INST ALLA TION Continued USING ELBOW OFFSETS (30E-12DM) 1. T o achieve desired offset, you may install combinations of 12", 18", 24", 36" and 48" length of double wall pipe (see offset chart and Figure 7). OFFSET CHART (22-50 FT . SYSTEM HEIGHT) Figure 7 - T ypical Offset T erminations Ret ...

  • FMI F48H(I)(R)A - page 8

    www .fmipr oducts.com 124386-01A 8 INST ALLA TION Continued Figure 9 - Elbow Offset B A Screws FIRESTOP SP ACERS (FS-10) Firestop spacers are required at each point where chimney penetrates a floor space. Their purpose is to establish and maintain required clearance between chimney and combustible materials. When pipe passes through a framed openin ...

  • FMI F48H(I)(R)A - page 9

    www .fmipr oducts.com 124386-01A 9 INST ALLA TION Continued FLASHING INST ALLA TION (V6F-10DM OR V12F-10DM) Determine ashing to be used with roof open - ing chart. Slide ashing over pipe until base is at against roof. Replace as many shingles as needed to cover exposed area and ashing base. Secure in position by nailing through shingles ...

  • FMI F48H(I)(R)A - page 10

    www .fmipr oducts.com 124386-01A 10 10 FOOT RULE All ue gas outlet chimney terminations must extend a minimum of 3 feet in height above highest point where it passes through the roof and must be at least 2 feet above highest point of the roof that is within a horizontal distance of 10 feet (see Figure 17). INST ALLA TION Continued FINISHING FIRE ...

  • FMI F48H(I)(R)A - page 11

    www .fmipr oducts.com 124386-01A 11 FIREBRICK WALL INST ALLA TION IMPORT ANT : Installation of brick should be done after the re - place is placed in a permanent location. 1. The replace is shipped with the hearth preinstalled. It is held in place for ship - ping with 3 shipping brackets (Figure 19). Remove these brackets before installing an ...

  • FMI F48H(I)(R)A - page 12

    www .fmipr oducts.com 124386-01A 12 FIREBRICK WALL INST ALLA TION Continued Figure 24 - Installing T op Rear Wall Retaining Bracket 5. Install the rear top rebrick wall. Lift the panel up with the front of the rebrick wall facing toward the front of the replace. The bottom of the panel has two tabs that slide into the bracket on the top of ...

  • FMI F48H(I)(R)A - page 13

    www .fmipr oducts.com 124386-01A 13 INST ALLING GRA TE RET AINERS 1. Place the provided grate retainers on the hearth as shown in Figure 26. The back of the retainer will be ush with the rear rebrick wall. Mark the center of the hole on the hearth with a marker . 2. Drill two holes in the hearth in the marked locations using a masonry 3/16&qu ...

  • FMI F48H(I)(R)A - page 14

    www .fmipr oducts.com 124386-01A 14 Gas line hook up should be done by your supplier or a qualied service person. Note: Before you proceed, make sure your gas supply is turned off. Use only a 1/2" black iron pipe and appropri - ate ttings. 1. Remove knockout indentation on refrac - tory or rebrick wall located above refrac - tory hear ...

  • FMI F48H(I)(R)A - page 15

    www .fmipr oducts.com 124386-01A 15 Figure 29 - Securing Door Rails to Fireplace Bottom Rail (Use as a T emplate before Drilling) Concrete Screws T op Rail Drill Holes into Bricks Remove Screws then Replace to Secure T op Rail IMPORT ANT : Install top and bot- tom rails and hardware before installing glass door panels. Rail installation 1 . Remove ...

  • FMI F48H(I)(R)A - page 16

    www .fmipr oducts.com 124386-01A 16 Figure 32 - Adjusting Bi-Fold Doors GLASS DOOR INST ALLA TION Continued Spring Clip Side Front Face Partially Opened Door OPERA TION AND MAINTENANCE GLASS DOORS Glass doors are optional with replace. When replace is in operation, doors must be fully opened or fully closed position only or a re hazard may ...

  • FMI F48H(I)(R)A - page 17

    www .fmipr oducts.com 124386-01A 17 OPERA TION AND MAINTENANCE Continued Figure 34 - Operating Damper Handle Damper Handle Retaining Bracket (Holds Damper Door Closed) Swing Door Down to Open Swing Door Up to Close Secondary Retaining Bracket (Holds Damper Door Open) FULL Y OPEN POSITION FULL Y CLOSED POSITION If you wish to install an unvented (ve ...

  • FMI F48H(I)(R)A - page 18

    www .fmipr oducts.com 124386-01A 18 P ARTS KEY NO. P ART NO. DESCRIPTION QTY . 1 124652-01 Left Leading Brick Red • 1 124652-03 Left Leading Brick Ivory • 1 2 124652-02 Right Leading Brick 36" Red • 1 124652-04 Right Leading Brick 42"/50" Red • 1 3 125634-01 Hearth Red • 1 125634-02 Hearth Ivory • 1 4 124646-01 Rear T op ...

  • FMI F48H(I)(R)A - page 19

    www .fmipr oducts.com 124386-01A 19 ACCESSORIES BI-FOLD GLASS MASONR Y DOOR BDMO48E - 48" Ebony BDMO48G - 48" Pewter BDMO48C - 48" Oiled Bronze DOUBLE W ALL PIPE - 12-12DM, 18-12DM, 24-12DM, 36-12DM, 48-12DM, 12-12HT , 18-12HT , 24-12HT , 36-12HT and 48-12HT 30° OFFSET AND RETURN 30E-12DM and 30E-12HT OPTIONAL OUTSIDE AIR KIT FOR FL ...

  • FMI F48H(I)(R)A - page 20

    124386-01 Rev . A 10/10 2701 S. Harbor Blvd. Santa Ana, CA 92704 1-866-328-4537 www .fmiproducts.com ACCESSORIES Continued SQUARE CHASE-TOP TERMINA TION - STL-12D ROUND TOP TERMINA TIONS RL T -12D AND RL T -12HT OPTIONAL HEARTH SP ACER HS48 24" ROUND WOODNOOK - DHR-24 ROOF FLASHING V6F-10DM - 0 to 6/12 Pitch V12F-10DM - 6/12 to 12/12 Pitch FIR ...

Fabricant FMI Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilFMI F48H(I)(R)A peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques FMI
- manuels d’utilisations F48H(I)(R)A
- fiches produit FMI
- dépliants
- ou étiquettes-énergie FMI F48H(I)(R)A
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation FMI F48H(I)(R)A.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation FMI F48H(I)(R)A, manuels d’entretien, brefs manuels ou manuels de l’utilisateur FMI F48H(I)(R)A. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit FMI F48H(I)(R)A.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil FMI F48H(I)(R)A, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser FMI F48H(I)(R)A par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs FMI F48H(I)(R)A.

Le manuel d’utilisation complet FMI, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel FMI F48H(I)(R)A - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières FMI F48H(I)(R)A, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lFMI F48H(I)(R)A qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil FMI F48H(I)(R)A - qui devraient nous aider dans les premières étapes lors de l'utilisation FMI F48H(I)(R)A
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de FMI F48H(I)(R)A
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service FMI F48H(I)(R)A dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de FMI F48H(I)(R)A?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec FMI F48H(I)(R)A, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec FMI F48H(I)(R)A il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image