    1 These instructions are to be left with the user Installation and User Guide SHOWER VALVE BUILT IN DUAL CONTROL ...

  • Kohler Discovery - page 2

    2 CONTENTS Introduction ............................................................................................. 3 Safety : Warnings .................................................................................... 3 Pack Contents ......................................................................................... 4 Dimensions ........ ...

  • Kohler Discovery - page 3

    3 This Discovery Thermostatic Shower Control is precision engineered and should give continued safe and controlled performance, provided: 1. It is installed, commissioned, operated and maintained in accordance with manufacturers recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. The fu ...

  • Kohler Discovery - page 4

    4  1 x Control Assembly  Tick the appropriate boxes to familiarize yourself with the Discovery Thermostatic Shower Control part names and to confirm that the parts are included.  PACK CONTENTS  1 x Shower Valve fitted to the Building-in Shroud  3 x Compression Nuts  3 x Olives   x Flow Regulator (12 litres per minute)  1 ...

  • Kohler Discovery - page 5

    5 DIMENSIONS Note! All Dimensions are Nominal Pipe Centres 186 mm 47 mm 64 - 82 mm 108 mm 231 mm 27 mm ...

  • Kohler Discovery - page 6

    6 SPECIFICATIONS Pressures Maximum Static Pressure: 10 Bar . Minimum Maintained Pressure (Gas Water Heater): 1.0 Bar . (for optimum performance initial supplies should be nominally equal). Minimum Maintained Pressure (Gravity System): 0.1 Bar . (0.1 bar = 1 Metre head from base of cold tank to the outlet of the shower handset). Maximum Maintained P ...

  • Kohler Discovery - page 7

    7 Connections Standard connections are: Hot-Left, Cold-Right, Top-Outlet, if reversed inlets are required refer to sections: ‘Installation’ and ‘Reversed Supplies’ . Inlets: 15 mm Compression. Outlet: 15 mm Compression. Thermostatic Shut-down Thermostat will shut off Hot Supply Within 2 Seconds if Cold Supply Fails. (Achieved only if the ho ...

  • Kohler Discovery - page 8

    8 Flow Regulator Recommended INSTALLATION REQUIREMENTS Isolating valve Mixing Valve Twin Impeller Pump Tempering Valve Pressure Reducing Valve Single Impeller Pump Overflow Indicator Mini Expansion Vessel Gas heated system The shower MUST be installed with a gas water heater or combination boiler of a fully modulating design. Note! Flow regulator r ...

  • Kohler Discovery - page 9

    9 Flow Regulator Recommended Flow Regulator Recommended Unvented mains pressure system The shower can be installed with a unvented, stored hot water cylinder. Pumped system The shower can be installed with an inlet pump (twin impeller). The pump must be installed on the floor next to the hot water cylinder. Note! Flow regulator recommended to be in ...

  • Kohler Discovery - page 10

    10 INSTALLATION General Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. The installation must comply with the “Water Supply Regulations 1999 (Water Fittings)” or any particular regulations and practices, specified by the local water company or water ...

  • Kohler Discovery - page 11

    11 Installation Methods The Discovery Thermostatic Shower Control can be installed using Rear Fixing Points on the Body, or by using the Securing Brackets (supplied) on the Front Face of a Solid Wall or Stud Partition, or on the Rear Face of a Laminated Panel. For installation from the front face into a Solid Wall or Stud Partition using the Securi ...

  • Kohler Discovery - page 12

    12 1. Solid Wall or Stud Partition (Using Securing Brackets - Mounting off Front Face) 1.1 Remove the three securing screws and remove the shower valve from the building-in shroud (retain the screws for later use). 1.2 Mark the position of the shower valve, a cut out 150 x 170 mm (Max) is required. Note! Use a spirit level to make sure that the hol ...

  • Kohler Discovery - page 13

    13 1.7 Fit the three securing brackets to the shower valve. Important! Make sure that the correct holes are used, otherwise the backplate will not fit (refer to illustration). Note! The brackets can be rotated for suitable fixing points. 1.8 Mark the positions of the countersunk fixing holes on the wall. Note! Make sure that they do not interfere w ...

  • Kohler Discovery - page 14

    14 1.14 Re-fit the building-in shroud to the shower valve using the three fixing screws. 1.15 Using the building-in shroud as a guide for the finished wall thickness, finish the wall. Caution! Make sure that the finished wall is within the minimum and maximum limits otherwise the control components will not fit correctly. 1.16 Remove the building-i ...

  • Kohler Discovery - page 15

    15 2. Solid Wall or Stud Partition (Using Rear Fixing Points on Shower Control) 2.1 Refer to section: ‘1. Solid Wall or Stud Partition Installation (Using Securing Brackets - Mounting off Front Face)’ and follow instructions 1 to 4. 2.2 Cut away the plasterboard or brick work to the required depth. Important! This depth ‘X’ will depend on t ...

  • Kohler Discovery - page 16

    16 2.3 Mark the positions of the fixing screw holes on the wall. 2.4 For solid walls drill two 6 mm holes for the wall plugs. 2.5 Fit the wall plugs (supplied) and fix the shower valve to the wall with the securing screws (supplied). Note! For stud partition installations alternative fixings may be required (not supplied) to fix the shower valve to ...

  • Kohler Discovery - page 17

    17 Note! For laminated panels the shower valve must be positioned from the rear of the panel. Panel thickness must be between 4 and 22 mm (if a thicker panel is used it will be necessary to recess the securing brackets into the rear of the panel). Important! Make sure that there is a minimum clearance of 64 mm behind the laminated panel to house th ...

  • Kohler Discovery - page 18

    18 3.6 To assist in marking the positions of the fixing holes, reverse the shower valve and fit the building in shroud through the cutout in the front of the panel. Mark the positions of the M5 fixing holes in the two top brackets only . Important! Make sure that the correct holes are used (refer to illustration). Warning! Do not drill any holes fo ...

  • Kohler Discovery - page 19

    19 Control Assembly 1. Pull off the temperature knob. 2. Carefully separate the concealing plate from the backplate. Note! Use a screwdriver in the cutout to assist separation. 3 . Fit the backplate to the shower control and secure with the three securing screws (removed from the building-in shroud). Make sure that the seal is fully compressed on t ...

  • Kohler Discovery - page 20

    20 Push up and Latch over the Top of the Backplate Align Flow Lever as Shown ‘Click’ into Position 5. Align the flow control lever so that the lever is pointing up (refer to illustration). 6. Slide the flow control lever and concealing plate over the flow control hub. 7. Latch the top of the concealing plate over the top of the backplate. Note! ...

  • Kohler Discovery - page 21

    21 Reversed Supplies The Discovery Dual Control is supplied with inlet connections Hot-Left , Cold-Right and Top-Outlet as standard. If the hot and cold water supply pipes have been reversed during installation the following procedure must be performed. Note! Refer to illustrations in section: ‘ Installation, Control Assembly’. ‘O’ Key 1. I ...

  • Kohler Discovery - page 22

    22 COMMISSIONING Maximum Temperature Setting The Thermostatic Shower Controls are preset at approximately 43 °C at the factory. If adjustment is required, set the maximum temperature as follows: Note! Make sure that the hot water temperature is at least 10 °C above the required maximum showering temperature. 1. Pull-off the temperature knob. 2. U ...

  • Kohler Discovery - page 23

    23 OPERATION Note! If excessive flow rate is experienced from the Shower Control, install the supplied Flow Regulator, refer to the Discovery Fittings Installation and User Guide. OFF ON COLD HOT Flow Control Lever Temperature Knob ...

  • Kohler Discovery - page 24

    24 FAULT DIAGNOSIS SYMPTOM 1. Only hot or cold water from the control outlet. 2. Fluctuating or reduced flow rate. 3. No flow rate from the control outlet. 4. Blend temperature drift. 5. Maximum blend temperature setting too hot or too cold. 6. Water leaking from the shower control fitting. 7. Flow rate too low or too high. CAUSE/RECTIFICATION a. I ...

  • Kohler Discovery - page 25

    25 ‘O’ Key Supply Filter MAINTENANCE General This Product is precision engineered and should give continued safe and controlled performance, provided: 1. It is installed, commissioned, operated and maintained in accordance with manufacturers recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functio ...

  • Kohler Discovery - page 26

    26 SPARE PARTS 1609.040 (A) Thermostatic Cartridge Assembly 1609.041 (B) Elbow Pack (2 off) 1609.042 (C) Flow Control Assembly 1609.043 (D) Flow Control Housing 1609.044 (E) Non-Return Valve (2 off) 1609.045 (F) Screw Pack (not illustrated) 1609.046 (G) Filter Pack (2 off) 1609.047 (H) Seal Pack (not illustrated) 1609.048 (I) Component Pack 1609.04 ...

  • Kohler Discovery - page 27

    27 J A B C C, K, J D D D E G I L K, J ...

  • Kohler Discovery - page 28

    28 7 - # 5 1058366-W2-A (1609) © Kohler Mira Limited, February 2006 CUSTOMER SERVICE ...

Fabricant Kohler Catégorie Plumbing Product

Les documents que nous recevons du fabricant de l'appareilKohler Discovery peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Kohler
- manuels d’utilisations Discovery
- fiches produit Kohler
- dépliants
- ou étiquettes-énergie Kohler Discovery
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Kohler Discovery.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Kohler Discovery, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Kohler Discovery. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Kohler Discovery.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Kohler Discovery, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Kohler Discovery par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Kohler Discovery.

Le manuel d’utilisation complet Kohler, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Kohler Discovery - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Kohler Discovery, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKohler Discovery qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Kohler Discovery - qui devraient nous aider dans les premières étapes lors de l'utilisation Kohler Discovery
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Kohler Discovery
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Kohler Discovery dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Kohler Discovery?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Kohler Discovery, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Kohler Discovery il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image