Manuel d’utilisation Cabletron Systems 7F06-02

28 pages 0.48 mb
Télécharger

Aller à la page of 28

Summary
  • Cabletron Systems 7F06-02 - page 1

    7F06-02 FDDI Smar tSWITCH ™ Interf ace Module User’ s Guide 9031672-01 ...

  • Cabletron Systems 7F06-02 - page 2

    Notice i NO TICE Cabletron Systems r eserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardwar e, firmware, or softwar e described in this manual is subject to ...

  • Cabletron Systems 7F06-02 - page 3

    Notice ii FCC NO TICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to c ...

  • Cabletron Systems 7F06-02 - page 4

    Notice iii VCCI NO TICE This equipment is in the 1st Class Category (information equipment to be used in commercial and/or industrial ar eas) and conforms to the standards set by the V oluntary Control Council for Interference by Information T echnology Equipment (VCCI) aimed at preventing radio interfer ence in commercial and/or industrial areas. ...

  • Cabletron Systems 7F06-02 - page 5

    v CONTENTS CHAPTER 1 INTRODUCTION 1.1 USING THIS MANUAL ......................................................................... 1-1 1.2 THE 7F06-02 MODULE ........................................................................... 1-2 1.2.1 Cable T ype and FPIMs .................................................................. 1-2 1.2.2 7C03 MMA ...

  • Cabletron Systems 7F06-02 - page 6

    vi Contents 5.7 PHYSICAL ................................................................................................5-2 5.7.1 Dimensions .....................................................................................5-2 5.7.2 W eight .............................................................................................. 5-2 ...

  • Cabletron Systems 7F06-02 - page 7

    1-1 CHAPTER 1 INTRODUCTION W elcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User ’ s Guide . This guide is a simple refer ence for installing and using the 7F06-02 Module. Before installing this module, you should carefully r ead through this manual to gain a full understanding of its capabilities. The 7F06-02 Module is a t ...

  • Cabletron Systems 7F06-02 - page 8

    1-2 INTRODUCTION 1.2 THE 7F06-02 MODULE The 7F06-02 Module provides two Fiber Optic ports via fr ont panel FPIM modules. 1.2.1 Cable T ype and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 Smart Switch Module through the chassis backplane. The front panel connections ar e standard Cabletr on FPIMs. There are two ...

  • Cabletron Systems 7F06-02 - page 9

    INTRODUCTION 1-3 Figure 1-1. 7F06-02 Module 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch. The modular design of the 7C03 MMAC SmartSwitch allows ot ...

  • Cabletron Systems 7F06-02 - page 10

    1-4 INTRODUCTION T oken Ring to be used with the 7F06-02 Module. These modules provide the capability to shar e data without the use of external bridges or routers. The 7C03 MMAC SmartSwitch is a unique module that can be installed in an MMAC Series chassis. The 7C04 W orkgroup SmartSwitch and the 7C04-R W orkgroup SmartSwitch ar e stand- alone cha ...

  • Cabletron Systems 7F06-02 - page 11

    INTRODUCTION 1-5 1.4 RELA TED MANU ALS The manuals listed below should be used to supplement the procedur es and other technical data provided in this manual. The procedur es will be refer enced, where appr opriate, but will not be repeated. 7X00 SmartSwitch Control Module User’ s Guide 7F06-02 Local Management Appendix 7C03 MMAC SmartSwitch Inst ...

  • Cabletron Systems 7F06-02 - page 12

    2-1 CHAPTER 2 NETWORK REQ UIREMENTS Before installing Cabletr on Systems 7F06-02 Module, review the network requir ements outlined in this chapter . All requir ements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module. Failure to do so may r esult in unsatisfactory network performance. Appendix A 2.1 FPI ...

  • Cabletron Systems 7F06-02 - page 13

    2-2 NETWORK REQ UIREMENTS Transmitter power parameters are listed in Table 2-2. The link distance is up to 2 kilometers on the multimode fiber- optic cable as specified by ANSI MMF-PMD. T able 2-2. T ransmitter P ower P arameters Parameter T ypical V alue W orst Case W orst Case Budget T ypical Budget 50/125 µ m fiber -13.0 dBm -15.0 dBm 13.0 d ...

  • Cabletron Systems 7F06-02 - page 14

    NETWORK REQ UIREMENTS 2-3 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Shielded T wisted Pair (STP) connection. The pinouts for both are listed in T able 2-3. The link distance is up to 100 meters on unshielded twisted pair cable ...

  • Cabletron Systems 7F06-02 - page 15

    2-4 NETWORK REQ UIREMENTS 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector . The specifications for both devices ar e listed in T able 2-4. The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on single m ...

  • Cabletron Systems 7F06-02 - page 16

    3-1 CHAPTER 3 INST ALLA TION/REMO V AL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 W orkgroup SmartSwitch • 7C04-R W orkgroup SmartSwitch. Also included in the chapter are instr uctions the front panel FPIMs. 3.1 UNP A CKING THE 7F06-2 MODULE Unpack the 7F06-2 Module ...

  • Cabletron Systems 7F06-02 - page 17

    3-2 INST ALLA TION/REMO V AL Figure 3-1. Installing an FPIM 3.3 INST ALLING/REMO VING THE 7F06-02 MODULE The following procedur e detail the installing and removal pr ocedure for the 7F06-02 module. 3.3.1 Installing in the 7C03 SmartSwitch The 7F06-02 Module is installed in the 7C03 MMAC SmartSwitch using the following steps and referring to Figur ...

  • Cabletron Systems 7F06-02 - page 18

    INST ALLA TION/REMO V AL 3-3 Notes: The left most slot in the 7C03 MMAC SmartSwitch is reserved for the 7X00 SmartSwitch Module. Before installing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1. Remove the blank panel covering the slot in which t ...

  • Cabletron Systems 7F06-02 - page 19

    3-4 INST ALLA TION/REMO V AL Note: Before removing the 7F06-02 module, attach the wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. 1. Use a slotted screwdriver to loosen the two scr ews that secure the module to the chassis. 2. Locate the two ejector tabs on the module (to the rig ...

  • Cabletron Systems 7F06-02 - page 20

    INST ALLA TION/REMO V AL 3-5 3.3.3 Installing in the 7C04 or 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R W orkgroup SmartSwitch using the following steps and referring to the appropriate figur e. Notes: The top slot in the 7C04 Workgroup SmartSwitch is reserved for the 7X00 SmartSwitch Module. The bottom slo ...

  • Cabletron Systems 7F06-02 - page 21

    3-6 INST ALLA TION/REMO V AL Figure 3-4. Installing the 7F06-02 Module in the 7C04 W orkgroup SmartSwitch Figure 3-5. Installing the 7F06-02 Module in the 7C04-R W orkgroup SmartSwitch SN 1 2 3 4 P S P S SP P WR SN M AC AD R C PU 7X00 SP SN 7A06-01 SP FANS 4 3 2 1 PWR SN MAC ADR CPU 7F06-02 7X00 SP SP SP P WR SN M AC A D R C PU 7X00 SP ...

  • Cabletron Systems 7F06-02 - page 22

    INST ALLA TION/REMO V AL 3-7 3.3.4 Removing fr om the 7C04 or 7C04-R W orkgr oup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R W orkgroup SmartSwitch, can be r emoved whenever necessary . Follow the steps below and refer to the appr opriate figure to remove the module. Note: Before removing the 7F06-02 module, attach the wrist ...

  • Cabletron Systems 7F06-02 - page 23

    3-8 INST ALLA TION/REMO V AL Figure 3-7. Removing the 7F06-02 Module fr om the 7C04-R W orkgroup SmartSwitch FANS SN 4 3 2 1 Ejector T abs Screws ...

  • Cabletron Systems 7F06-02 - page 24

    4-1 CHAPTER 4 TROUBLESHOO TING The 7F06-02 Module uses LANVIEW , Cabletron Systems built-in visual diagnostic and status monitoring system. W ith LANVIEW LEDs the status of each transmit and receive port on the 7F06-02 Module can be determined, at a glance. This section discusses the function and purpose of the LEDs on the 7F06-02 Module. Figure 4- ...

  • Cabletron Systems 7F06-02 - page 25

    4-2 TROUBLESHOO TING T able 4-1 indicates the state of the receive port. T able 4-2 indicates the state of the transmit port. T able 4-1. Port Receive LEDs LED Color State Y ellow (Flashing) Data activity (flashing to steady on indicates rate) Off No activity , port can be disabled or enabled T able 4-2. Port T ransmit LEDs LED Color State Green ( ...

  • Cabletron Systems 7F06-02 - page 26

    TROUBLESHOO TING 4-3 T able 4-3 indicates the state of the A/B Link LEDs. T able 4-3. Link LEDs A p S B State Green N/A N/A Green Ports Enabled & Active Green Green Off Green THRU A, MAC on Primary , Secondary Bypasses Board Green Green Y ellow Green THRU A, MAC on Primary , No MAC on Secondary Green Off Gr een Green THRU B, MAC on Secondary , ...

  • Cabletron Systems 7F06-02 - page 27

    5-1 CHAPTER 5 TECHNICAL SPECIFICA TIONS This chapter includes the technical specifications for Cabletron Systems 7F06-02 module. Cabletron Systems r eserves the right to change these specifications at any time without notice. 5.1 ST AND ARDS IEEE 802.1D IEEE 802.3i 10BASE-T 5.2 EMI The EMI requir ements of: • FCC Part 15 Class A • EN 55022 Cl ...

  • Cabletron Systems 7F06-02 - page 28

    5-2 TECHNICAL SPECIFICA TIONS 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allowed limits of conducted and radiated emissions. This equipment meets the safety requir ements of: • UL 1950 • CSA C22.2 No. 950 • EN 60950 • IEC 950 5.6 SER VICE MT ...

Fabricant Cabletron Systems Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilCabletron Systems 7F06-02 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Cabletron Systems
- manuels d’utilisations 7F06-02
- fiches produit Cabletron Systems
- dépliants
- ou étiquettes-énergie Cabletron Systems 7F06-02
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Cabletron Systems 7F06-02.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Cabletron Systems 7F06-02, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Cabletron Systems 7F06-02. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Cabletron Systems 7F06-02.

Manuel d’utilisation complet de l’appareil Cabletron Systems 7F06-02, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Cabletron Systems 7F06-02 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Cabletron Systems 7F06-02.

Le manuel d’utilisation complet Cabletron Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Cabletron Systems 7F06-02 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Cabletron Systems 7F06-02, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lCabletron Systems 7F06-02 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Cabletron Systems 7F06-02 - qui devraient nous aider dans les premières étapes lors de l'utilisation Cabletron Systems 7F06-02
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Cabletron Systems 7F06-02
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Cabletron Systems 7F06-02 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Cabletron Systems 7F06-02?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Cabletron Systems 7F06-02, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Cabletron Systems 7F06-02 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)