    Inst allation and User Manual Infinity 16e Infinity 16e Continuous Flow W ater Heater Import ant. Read these instructions carefully befo re attempting installation or use of this appliance. All work must be carried out by competent persons. ...

  • Rinnai 16e - page 2

    2 RINNAI UK W ARRANTY As the purcha ser of th is high quality Rinnai Water H eater y ou are provided with th e following co nditional g uarantee. Definition of S tandard Use. The warranty period allocated under Standa rd Use is base d on Domestic and Lig ht Commercial hot water usage. Rinnai Stand ard Use warranty periods apply only where Rinnai wa ...

  • Rinnai 16e - page 3

    3 CONTENTS Rinnai UK W arranty..…………………….. Unpacking Rinnai Water Heater… ……… Installation Ins tructi ons………… ………… Flue R equire ments… …………… ………... Dim ens ion s……………… ………… ……… Te chnic al D eta ils. .……… ………………… Featur es and Benefit s……… ...

  • Rinnai 16e - page 4

    4 UNP ACKING RINNAI W A TER HEA TER • After unpacking the ap pliance check for damage, if the heater is damaged contact your supplier immediately . Do not install a damaged appliance be fore checking with y our supplier. • One remote control an d heater accessories pack are inside the car ton. • Check that the appliance supplied is the correc ...

  • Rinnai 16e - page 5

    5 IMPORTA NT IN FORMA TION 1. Gas safety (Install ation & Use) r egulations 19 98 are the ‘ Rules in fo rce’. In y our own i ntere st an d that of sa fety, it is law that all g as appl ianc es are inst alled by compe tent p erson s in acco rdanc e with the a bove regul ations . Fail ure to ins tall appliances correctly c ould lead t o prose ...

  • Rinnai 16e - page 6

    6 Gene ral In sta llatio n Info rmation . External Installations. The Rinnai Inf inity 16e is for exte rnal mounting onl y. The unit i s classed as a Catego ry A3 flueles s appliance as described by CEN CR1 749. Although BS 5440 d oes not relate di rectly to heaters in this category the rules must be follow ed wh en posi tioni ng th e appli ance, e ...

  • Rinnai 16e - page 7

    7 INST ALLA TION INSTRUCTIONS - CONNECTIONS Water Sup ply . Where the wa ter s upply press ure exceed s 10 bar, an ap prov ed pr essure redu cing device is r equired at t he inlet of the applian ce. To a chieve the r ated flow a minim um water s upply press ure o f 0.8 bar is requi red a t the applian ce in let. Th e unit will o perate at lower s u ...

  • Rinnai 16e - page 8

    8 Dimension Ter minal Position Distance A Directly bel ow an opening , air brick, o pening windo ws, etc. 300mm B Abov e an o penin g, air brick , open ing wi ndo w, etc. 300m m C Horiz ontally to an op ening, air bric k , opening windo w, etc. 300mm D Be low gutte rs, soil pip es or dr ain pip es. 75mm E Below eaves. 200mm F Below balconi es or ca ...

  • Rinnai 16e - page 9

    9 DIMENSIONS ...

  • Rinnai 16e - page 10

    10 TECHNICAL DET AILS * Facto ry Settin g **M inimum operation flow based on te mperatu re setpoi nt and inlet condi tions . Infinity M odel Infi nity 16e Units Installati on External Nat Gas Press Low 1.8 mbar Nat Gas Press High 8.8 mbar LPG P ress Low 1.8 mbar LPG P ress Hig h 8.1 mbar Heig ht 530 mm W i dth 35 0 mm Dept h 170 mm We i gh t 1 5 kg ...

  • Rinnai 16e - page 11

    11 Congr atulatio ns on pu rchasi ng the T echnol ogica lly Adv anced , Temper ature Control led, Rinnai Hot W ater Sy stem. • The Ri nnai Infinit y 16e NEVER RUNS OUT of hot water . As long as el ectrici ty, water, and g as su ppli es are conn ected, hot wate r is av ailabl e wh en hot water taps are open. • Built into the main micro -processo ...

  • Rinnai 16e - page 12

    12 Excessively hot water is dangerous, especially for young c hildren and t he infirm . The water heate r allows y ou to control the t emperature of your hot water to saf e levels. Do stay with childr en whenever th ey are in t he bathroom. Do take them o ut of the b athroom if you need to answer the phone or door. Do test the temperatu re of the w ...

  • Rinnai 16e - page 13

    13 IMPORT ANT INFORMA TION Alwa ys c heck wate r temp eratu re be fore use. Refer to wa rning about hot water on page 12 f or impo rtant safe ty info rmation. Hot water may go out without wa rning at low water flows. The I nfin ity 16e controls the wate r temperat ure a utomat ically. For h igh temperat ures it may red uce the fl ow. The wat er fr ...

  • Rinnai 16e - page 14

    14 Rinnai Infinity product s have no pilo t light a nd when install ed without Tempe rature Controllers, the applia nce will operate automati cally as soon as a hot water tap is opened . The burne r ignites wi th elect ronic igniti on and t he flame exting uishes as soon as w ater flowing through the appliance stops. T u rn On by opening the hot wa ...

  • Rinnai 16e - page 15

    15 TEMPERA TURE CONTROLS - GENERAL When deciding on the best positi on for the temperature c ontrols, the f ollowing points should be take n into accou nt. • Fi t t he con tro ls out of r eac h of ch il dre n ( sugg es te d he ig ht from the f loo r 1 .5 m.) • Avoid po sitions wh ere the contro llers will become hot. Do not fit them near stoves ...

  • Rinnai 16e - page 16

    16 TEMPERA TURE CONTROLS - INST ALLA TION Universal Tem perature Controller MC-91-1A 1. Determin e the mo st suitable positio n for t he temperat ure contro ller. 2. Drill 3 h oles i n the wall as show n in fi g. 1, o ne for th e cabl e a nd two for the s ecuri ng sc rews . Ensure holes are drill ed deep enough. Fit wall plug s if need ed. (e nsu r ...

  • Rinnai 16e - page 17

    17 TEMPERA TURE CONTROLS - INST ALLA TION Conn ect ing O ne o r Tw o Co ntro lle rs 1. Iso late the pow er suppl y. 2. Remov e the f ront cover from the A pplia nce (4 scr ews) fig. 1. 3. Thread the cable through th e cable acces s hole at the ba se of th e app lianc e. 4. Connect th e spade conne ctors to t he ter minals marke d "Re mote C on ...

  • Rinnai 16e - page 18

    18 TEMPERA TURE CONTROLS The purpose of a Te mperature Cont roller is to enable the us er to hav e complete c ontrol over the hot water su pply. Used cor rectly, the hot water u nit will supply hot wat er at the temper ature selec ted, eve n when the wate r flo w is var ied, or when more th an one tap is used. Adjust ments to the operatio n of your ...

  • Rinnai 16e - page 19

    19 Remote temperatur e controllers a re a feature t hat provides cont rol over the water temperatu re. Rinnai Infinity wa ter heaters can be operate d with 1, 2, 3 or no temperatu re controllers. The Univ ersal controller M C-91-1A c omes as sta ndard with all Infinity wa ter heaters. NOTE: Each time a butt on is presse d, a BEEP will sound. The BE ...

  • Rinnai 16e - page 20

    20 TEMPERA TURE CONTROLS - OPERA TING Using 1 Universal T emperature Controller . Press the On/O ff but ton on the tem perat ure contr oller. The ON indicato r will glow on the Temperature Controller. This in dicates th at the he ater is re ady t o supply hot wate r when a tap is opened. A djustin g Tem pera ture Simply pres s the H ot Wat er Tempe ...

  • Rinnai 16e - page 21

    21 Using 2 or more Uni v ersal T emperature Controllers. Switching the sy stem ON. Using hot water. Bath room t empera tures should be no more than 50 0 C. The ho t wate r system a nd a ll contro llers can be switched ON and OFF f rom any cont roller by pressin g the On/Of f button as sho wn. W hen the s ystem is turned O N the w ater tempe rature ...

  • Rinnai 16e - page 22

    22 Using High T em perature Display Controllers. You will need to program th e Master cont roller if y ou want to dis play and us e temperatures over 50 0 C. Program ming only needs to be done on M aster universal controllers; other univers al controllers will not a llow this, and Delu xe Kitchen Controllers are su ppli ed al ready prog ramme d to ...

  • Rinnai 16e - page 23

    23 Note T o turn off your hot water syst em. Additional safety features. During normal operati on the system is left on. To turn the system off simply press the On/O ff button on any t emperature controller (wher e fitted). This will shut the w ater heate r down comple tely incl uding the te mpera ture contr oller digital display . The on i ndicato ...

  • Rinnai 16e - page 24

    24 TEMPERA TURE CONTROLS - INFORMA TION Do not pus h the On /Off bu tton on the Master c ontroller aft er transf erring p riority of te mperat ure s elect ion t o a S econda ry controller as the system will shut dow n. Do Not Turn OFF the Ma ster Controll er Temp eratu re prio rity c an not be switc hed to an other cont roller whe n the w ater i s ...

  • Rinnai 16e - page 25

    25 TESTING 1. Purge gas, h ot wate r and col d water s upply lines be fore makin g the fi nal conn ection of the water heater. Swarf in either the gas or water supplie s may cause damage . 2. Turn on ga s and cold water sup plies. 3. Test for wat er leak s and ga s escap es ne ar the uni t. 4. Isolate gas and electric suppl y. Rem ove te st point s ...

  • Rinnai 16e - page 26

    26 GAS PRESSURE SETTING The wo rking g as pressure on the wate r heater is e lectron ica lly contro lled and factory set. Under nor mal ci rcum stanc es it does not re quire adjustment during insta llation. Perfor m this procedure only if the unit is not operating correctly and all oth er possi ble ca uses for incorrect operation ha ve been elimi n ...

  • Rinnai 16e - page 27

    27 GAS PRESSURE SETTING 11 .Re move ru bber ac cess pl ug an d ad ju st t he regula tor sc rew on t he mod ulati ng v alve (f ig. 4) as re quired to the press ure b elow. 12.Loc k the reg ulati ng screw on the modu latin g val ve. 13.Set the appliance to ' Forced High' combust ion by setting both no. 3 and no. 4 dipswitch es of the bot to ...

  • Rinnai 16e - page 28

    28 DIP SWITCH SETTING Dip Switch Positions Explained OFF ON SW2 (top) 1 - Gas Type LEGEND: 2 - Temperature Black Section indicat es 3 - Temperature position of dip switch. 4 - Temperature OFF ON OFF ON OFF ON SW1 (bottom) 1 - Computer Programming 2 - Computer Programming OFF ON 3 - Combustion 4 Combustion Dip Swiches Explained GA S TYPE LPG NA T GA ...

  • Rinnai 16e - page 29

    29 DIP SWITCH SETTING Infinity 16e T emperatures - With or Without Remotes off on SW 2 off on SW 2 off on SW 2 1 1 1 2 2 2 3 3 3 4 4 4 40 deg C 43 deg C 50 deg C off on SW 2 off on SW 2 off on SW 2 1 1 1 2 2 2 3 3 3 4 4 4 55 deg C 65 deg C 75 deg C ...

  • Rinnai 16e - page 30

    30 ERROR MESSAGES Rinnai water heaters have the ability to check their own operation continuously. If a fault occurs, an error code will fl ash on the Di gita l Display if y ou hav e temp eratur e con troller s install ed. T his as sists with dia gnosin g the fault, and m ay ena ble y ou to ov erco me a proble m wit hout a se rvi ce call . Plea se ...

  • Rinnai 16e - page 31

    31 ERROR MESSAGES T roubleshooting w ithout controllers If you have not installe d temper ature controllers and experien ce the foll owing symp toms, pleas e c arry ou t the sugg estion s bel ow. If s ymp toms c onti nue, pl eas e conta ct Rin nai fo r adv ice. NOTE: Faults ca used by insufficient gas /water supply or gas/water quality and installa ...

  • Rinnai 16e - page 32

    32 REST ARTING THE RINNAI W A TER HEA TER Fol low ing a p ow er cut th e he at ers sho uld b e re sta rt ed in t hi s ma nne r. St andard system. Sin g le o r mu lt ip le w a te r he at er s w ithou t r em ot e con t ro ll er s. The heater s will auto matically rese t without any user involvem ent. Single or multi ple water heater s with remote con ...

  • Rinnai 16e - page 33

    33 WIRING DIAGRAM ...

  • Rinnai 16e - page 34

    34 DIAGNOSTIC POINTS Diagnost ic Poin ts- To be rea d in conju nction with the wiri ng diagram. ...

  • Rinnai 16e - page 35

    35 SPECIFICA TION Model …… …………… …………… ………… ……..….. .....……… ……… ……….. I nfi nity 16e Insta llati on …………………… ……………… ……. ..…… .…. ..……. Extern al locat ion onl y Fuel ………… ………… …………… ……………… ..….…. .……… ? ...

  • Rinnai 16e - page 36

    36 SER VICE CONT ACT Rinnai Rinna i UK L TD. 9 Christleton Court Manor Park Runcorn Cheshire WA7 1 ST T el. 01928 531870 Fax. 01928 531880 E-mail. info@rinnaiuk.com Web. www .rinnaiuk.com ...

Fabricant Rinnai Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilRinnai 16e peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Rinnai
- manuels d’utilisations 16e
- fiches produit Rinnai
- dépliants
- ou étiquettes-énergie Rinnai 16e
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Rinnai 16e.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Rinnai 16e, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Rinnai 16e. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Rinnai 16e.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Rinnai 16e, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Rinnai 16e par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Rinnai 16e.

Le manuel d’utilisation complet Rinnai, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Rinnai 16e - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Rinnai 16e, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRinnai 16e qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Rinnai 16e - qui devraient nous aider dans les premières étapes lors de l'utilisation Rinnai 16e
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Rinnai 16e
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Rinnai 16e dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Rinnai 16e?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Rinnai 16e, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Rinnai 16e il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)