Manuel d’utilisation Texas Instruments SWRU157D

21 pages 0.68 mb
Télécharger

Aller à la page of 21

Summary
  • Texas Instruments SWRU157D - page 1

    SWRU157D 2008 Low-Power RF ZigBee Sensor Monitor U se r ' s G u i d e User's Guide ...

  • Texas Instruments SWRU157D - page 2

    ...

  • Texas Instruments SWRU157D - page 3

    1 Contents ZIGBEE SENSOR MONITOR ................................................................................................................... 1 1. INTRODUCTION ................................................................................................................... ............ 2 1.1. CC2530ZDK ..................................... ...

  • Texas Instruments SWRU157D - page 4

    2 1. Introduction ZigBee Sensor Monitor (or ZSensorMonitor 1 ) is a PC application that will be used to monitor the sensors in a ZigBee Network. ZSensorMonitor can be used together with either the CC2530ZDK or an eZ430-RF2480 kit. The network is formed when setting up the basic out of the box demo included either of the kits. In the case of eZ430-R ...

  • Texas Instruments SWRU157D - page 5

    3 2. Inst allation The installation of ZSensorMonitor is very straight forward. Download the zip file from internet and unzip the setup file. Double click on the setup file and follow the instructions. 3. eZ430-RF2480 Driver Inst allation This section is only relevant if the eZ430-RF2480 kit platform is used. Note: When using eZ430-RF2480 the PC ap ...

  • Texas Instruments SWRU157D - page 6

    4 Select “Install the software automatically” and click next. If the IAR kickstart for MSP430 has been installed before this application, it might be that this dialog will pop up and ask the user to select one of the two inf files. Both inf files are equal and it doesn’t matter which one that is selected. Either should work fine. The installa ...

  • Texas Instruments SWRU157D - page 7

    5 If this warning appears, the option “Continue Anyway” must be selected in order to install the driver. This dialog will be shown when everything has been successfully installed. Click Finish to close the wizard. ...

  • Texas Instruments SWRU157D - page 8

    6 3.2. Windows Vista The first time the USB dongle (sink) is connected to the PC, the new HW is detected and the system will ask to install driver software. Select “Locate and install driver software”. Select “I don’t have the disc. Show me other options.” Select “Browse my computer for driver software.” ...

  • Texas Instruments SWRU157D - page 9

    7 The required “inf” file will be installed together with the application. Browse to the directory of the application and select the sub directory “Drivers”. Click Next to continue. Select “Install this driver software anyway” At the end the software should be successfully installed. Click Close to end the installation. ...

  • Texas Instruments SWRU157D - page 10

    8 4. User Interface The user interface is developed to be as simple as possible with only a few buttons and input fields. When the eZ430-RF2480 dongle is connected to the PC, the application will search for an applicable COM port and start reading if a connection is successfully established. Below is a screenshot showing a ZigBee Coordinator, Route ...

  • Texas Instruments SWRU157D - page 11

    9 4.1. Toolbar Pause captur ing dat a fr om the ser ial COM port Stop capt uri ng data fr om the ser ial COM port Star t capt uri ng data fr om the ser ial COM port Drop down li st wi th al l the avai labl e COM ports Refres h li st of seri al COM ports Configur ati on Open appli cati on user manual About info rm a tio n Start l ogging t o file O p ...

  • Texas Instruments SWRU157D - page 12

    10 4.3. Data logging and playback It is possible to capture the data traffic on the serial port to a log file for debugging and playback purposes. The log file is pure ASCII text which displays a time-stamp and the raw data in hexadecimal format. Data logging is started by clicking the button . The user will then be requested to provide a file usin ...

  • Texas Instruments SWRU157D - page 13

    11 4.4. Help The User’s Manual is a file which opens when the “help” button is clicked. The “About” button can be clicked to obtain information about the application. 4.5. Configuration Click on the “Configuration” button and the settings dialog will appear. ...

  • Texas Instruments SWRU157D - page 14

    12 Temperature unit Celsius or Fahrenheit can be selected. Time interval The timestamp of each node will be checked regularly to see if any message has been received within the given time interval. If the elapsed time is longer than specified, the Node will be removed from the screen. ...

  • Texas Instruments SWRU157D - page 15

    13 4.6. Network View The PC demo will always display one node on the top of the screen, the Sink. Below the Sink the presence of additional network nodes will be displayed as they are detected. Be aware that nodes may place themselves on top of existing nodes when they first appear, but can easily be dragged away with the mouse. The various states ...

  • Texas Instruments SWRU157D - page 16

    14 voltage and a timestamp from when the last message was received from this node. The source node will blink each time a message is received by the connected Sink node. The role of each node is also indicated if the mouse is held over the node for more than a second. The nodes are connected with arrows to show the relationship between parent and c ...

  • Texas Instruments SWRU157D - page 17

    15 5. T roubleshooting 5.1. Incorrect temperature values If the temperature is much different from the expected value, this is because the temperature sensor is not calibrated. 5.2. Status of the connected dongle NB! This section only applies to the eZ430-RF2480. It is possible for the status of the connected dongle to get out of synchronization if ...

  • Texas Instruments SWRU157D - page 18

    16 When the eZ430-RF2480 is removed, these dev ice drivers should disappear from the view in the Device Manager. If they don’t disappear, a restart of the PC will be necessary. Check that the “MSP430” device is availabl e in the drop down list of available COM ports. The serial COM port. The composite device ...

  • Texas Instruments SWRU157D - page 19

    17 5.6. Not able to start the application If an error message about missing the msvcp80.dll is received, or the error message shown below appears when attempting to start the application, you may be required to install an additional package from Microsoft. The package contains some additional runtime components needed by applications developed with ...

  • Texas Instruments SWRU157D - page 20

    18 Document History Revision Date Description/Changes swru157 08/03/2008 Initial release. swru157a 08/05/2009 • Added logging and playback • Changed document name • Added support for CC2530 Z- Stack Sensor Demo • Added status bar swru157d 25/08/2009 Changed document title ...

  • Texas Instruments SWRU157D - page 21

    19 IMPORTA NT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements,and other changes to its products and services at any time and to discontinue any product or service without notice. Customers shouldobtain the latest relevant information before pl acing ord ...

Fabricant Texas Instruments Catégorie Computer Monitor

Les documents que nous recevons du fabricant de l'appareilTexas Instruments SWRU157D peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Texas Instruments
- manuels d’utilisations SWRU157D
- fiches produit Texas Instruments
- dépliants
- ou étiquettes-énergie Texas Instruments SWRU157D
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Texas Instruments SWRU157D.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Texas Instruments SWRU157D, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Texas Instruments SWRU157D. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Texas Instruments SWRU157D.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Texas Instruments SWRU157D, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Texas Instruments SWRU157D par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Texas Instruments SWRU157D.

Le manuel d’utilisation complet Texas Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Texas Instruments SWRU157D - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Texas Instruments SWRU157D, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTexas Instruments SWRU157D qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Texas Instruments SWRU157D - qui devraient nous aider dans les premières étapes lors de l'utilisation Texas Instruments SWRU157D
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Texas Instruments SWRU157D
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Texas Instruments SWRU157D dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Texas Instruments SWRU157D?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Texas Instruments SWRU157D, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Texas Instruments SWRU157D il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)