Manuel d’utilisation Goldline LOGIC PL-P-4

36 pages 1.48 mb
Télécharger

Aller à la page of 36

Summary
  • Goldline LOGIC PL-P-4 - page 1

    Pro Logic Programming Flow Chart North Kingstown, RI 02852 USA 092337C Copyright © 2009 Goldline Controls www .goldlinecontrols.com Automation and Chlorination Inst allation Manual for model PL-P-4 LD C G LI N E ON T ROLS LD C G LI N E ON T ROLS denot es cond itiona l item s def ault m e nu day a nd tim e wa ter temperat ure air t emperatur e chlo ...

  • Goldline LOGIC PL-P-4 - page 2

    IMPORT ANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • ! W ARNING: Disconnect all AC power during inst allation. • ! W ARNING: W ater in excess of 100 degrees Fahrenheit may be hazardous to your health. • ! W ARNIN ...

  • Goldline LOGIC PL-P-4 - page 3

    T able of Content s Introduction Before Y ou Begin................................................................... 1 Installation S teps.................................................................... 2 1. Preparing General W ater Chemistry ..................................................... 2 Pool/Sp a W ater Salt......................... ...

  • Goldline LOGIC PL-P-4 - page 4

    Introduction Before Y ou Begin What’s Included Before attempting to install the Pro Logic system, check that the following components have been included in the package: Pr o Logic Electr onics Unit (3) T emperature sensors with 15 ft. (5m) cable, hose clamp What’s NOT Included Some of the additional items that you may need to complete an instal ...

  • Goldline LOGIC PL-P-4 - page 5

    4. Electrical W iring (page 10) Main service Grounding and bonding Circuit breakers Pro Logic control power High V oltage pool equipment Low voltage wiring (temperature sensors, flow switch, etc.) 2 29 ºC º F Ti Calcuim Hardne ss Ci To t a l Alkalinity Ai 53 60 66 76 84 94 103 12 16 19 24 29 34 39 .3 .4 .5 .6 .7 .8 .9 How to use: Measure pool p H ...

  • Goldline LOGIC PL-P-4 - page 6

    Gall o n s a n d ( L i t e r s ) o f P o o l / S p a w a t e r 12,0 00 14 ,00 0 16,0 00 1 8 , 0 0 0 2 0 , 0 0 0 2 2 , 0 0 0 3 2 , 0 0 0 2 4 , 0 0 0 3 4 , 0 0 0 2 6 , 0 0 0 3 6 , 0 0 0 2 8 , 0 0 0 3 8 , 0 0 0 3 0 , 0 0 0 4 0 , 0 0 0 Current salt level (45000) (52,500 ) (60,000) ( 6 7 , 5 0 0 ) ( 7 5 , 0 0 0 ) ( 8 2 , 5 0 0 ) ( 1 2 0 , 0 0 0 ) ( 9 0 ...

  • Goldline LOGIC PL-P-4 - page 7

    4 Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super Chlorinate cycle when the Aux button is pressed, rather than using the Settings Menu. Note that only one button can be assigned to this function. Aux1 Relay This feature allows the user to select either “Standard” (default) or “Dimmer” type ...

  • Goldline LOGIC PL-P-4 - page 8

    2. Mounting the Equipment Pro Logic Control Center The Pro Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The control must be mounted a minimum of 5 ft. (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The Control Center is designed to mount vertically on a flat surface with the ...

  • Goldline LOGIC PL-P-4 - page 9

    Optional AQL-CHEM2 CO 2 Dispensing Kit The AQL-CHEM2 is a CO 2 dispensing device that connects directly to the Pro Logic. When used with an AQL- CHEM, the Pro Logic will sense the pool’ s pH level and automatically dispense the correct amount of CO 2 to control the pool’ s pH to the desired level. W iring and plumbing requirements for the AQL-C ...

  • Goldline LOGIC PL-P-4 - page 10

    Wireless Remote Controls Note that the Pro Logic is compatible with AQL2 wireless remote controls only . A single AQL2-BASE-RF Base S tation must be installed on the Pro Logic in order to use any of the Goldline wireless remote controls. W ith the Base Station installed, there is no limit on the number of wireless remotes that can used. The maximum ...

  • Goldline LOGIC PL-P-4 - page 11

    3. Plumbing Pool/Sp a system configuration These systems use a single filter pump and filter . Pool or spa operation is controlled by two 3-way valves (suction and return). Refer to the diagram below . Some important notes regarding the Pro Logic control of Standard Pool/Spa systems: In Pool/Spa Config., select: Po o l / S p a S e t up Po o l a n d ...

  • Goldline LOGIC PL-P-4 - page 12

    T urbo Cell (choose proper model for your pool) The T urbo Cell (used for chlorine generation) should be plumbed AFTER the filter and heater . If installed on a pool/ spa combination system, the cell should be plumbed BEFORE the pool/spa return valve in order to allow proper chlorination of both the pool and the spa. Refer to plumbing diagram below ...

  • Goldline LOGIC PL-P-4 - page 13

    4. Electrical Wiring The Pro Logic Control Center requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center . Always: -Ensure that Power is disconnected pri ...

  • Goldline LOGIC PL-P-4 - page 14

    General Purpose Outlet If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockouts on the lower right side of the Pro Logic enclosure. Per code, the receptacle should be a GFCI type. Alternatively , connect a standard receptacle to a GFCB. Pro Logic Control Power The Pro Logic requires 120V AC, ...

  • Goldline LOGIC PL-P-4 - page 15

    ! W ARNING: Do not use the Pro Logic to control an automatic pool cover . Swimmers may become entrapped underneath the cover . T wo speed filter pump: Requires 2 relays (FIL TER plus one of the AUX relays) for proper operation of both speeds. ! IMPOR T ANT : Be sure to follow the wiring diagram below AND to configure the contr ol logic according to ...

  • Goldline LOGIC PL-P-4 - page 16

    Low V olt age Wiring V alve Actuators The Pro Logic can control up to three automatic valve actuators. T wo of the valve outputs are dedicated to the pool/ spa suction (V alve2) and return (V alve1) valves. V alve3 is for general purpose use (solar , water feature, in-floor cleaner , etc.). For installations with solar heating, Goldline of fers the ...

  • Goldline LOGIC PL-P-4 - page 17

    Laars Heaters 1. Turn power of f to heater . 2. Remove factory jumper from terminal block. 3. W ire Pro Logic to the heater as shown. 4. Ensure toggle switch is in the ON position. 5. Set heater thermostats to maximum position. to l imi t s wit che s remov e jumper Fusi bl e Link whit e whi t e Hayward Heaters Refer to the instructions in the heate ...

  • Goldline LOGIC PL-P-4 - page 18

    Pentair/Purex/MiniMax 1. T urn power off to heater . 2. Remove factory installed jumper from the “Ext Switch” connector . 3. W ire the Pro Logic to the “Ext Switch” connector as shown below . 4. The wires to the Pro Logic must be separated from any line voltage wires. Failure to follow these instructions may cause erratic operation of the h ...

  • Goldline LOGIC PL-P-4 - page 19

    Pentair/Purex/MiniMax 1. T urn power off to heater . 2. Remove factory installed jumper from the “Ext Switch” connector . 3. W ire the Pro Logic to the “Ext Switch” connector as shown below . 4. The wires to the Pro Logic must be separated from any line voltage wires. Failure to follow these instructions may cause erratic operation of the h ...

  • Goldline LOGIC PL-P-4 - page 20

    Laars Heaters 1. Turn power of f to heater . 2. Remove factory jumper from terminal block. 3. W ire Pro Logic to the heater as shown. 4. Ensure toggle switch is in the ON position. 5. Set heater thermostats to maximum position. to l imi t s wit che s remov e jumper Fusi bl e Link whit e whi t e Hayward Heaters Refer to the instructions in the heate ...

  • Goldline LOGIC PL-P-4 - page 21

    Low V olt age Wiring V alve Actuators The Pro Logic can control up to three automatic valve actuators. T wo of the valve outputs are dedicated to the pool/ spa suction (V alve2) and return (V alve1) valves. V alve3 is for general purpose use (solar , water feature, in-floor cleaner , etc.). For installations with solar heating, Goldline of fers the ...

  • Goldline LOGIC PL-P-4 - page 22

    ! W ARNING: Do not use the Pro Logic to control an automatic pool cover . Swimmers may become entrapped underneath the cover . T wo speed filter pump: Requires 2 relays (FIL TER plus one of the AUX relays) for proper operation of both speeds. ! IMPOR T ANT : Be sure to follow the wiring diagram below AND to configure the contr ol logic according to ...

  • Goldline LOGIC PL-P-4 - page 23

    General Purpose Outlet If desired, a duplex receptacle with weatherproof cover (supplied by installer) may be installed in the knockouts on the lower right side of the Pro Logic enclosure. Per code, the receptacle should be a GFCI type. Alternatively , connect a standard receptacle to a GFCB. Pro Logic Control Power The Pro Logic requires 120V AC, ...

  • Goldline LOGIC PL-P-4 - page 24

    4. Electrical Wiring The Pro Logic Control Center requires both high and low voltage connections. Low voltage connections will be made to actuators, sensors, remote keypad, etc. High voltage connections will be made to pumps, lights, etc., as well as providing direct input power to the Control Center . Always: -Ensure that Power is disconnected pri ...

  • Goldline LOGIC PL-P-4 - page 25

    T urbo Cell (choose proper model for your pool) The T urbo Cell (used for chlorine generation) should be plumbed AFTER the filter and heater . If installed on a pool/ spa combination system, the cell should be plumbed BEFORE the pool/spa return valve in order to allow proper chlorination of both the pool and the spa. Refer to plumbing diagram below ...

  • Goldline LOGIC PL-P-4 - page 26

    3. Plumbing Pool/Sp a system configuration These systems use a single filter pump and filter . Pool or spa operation is controlled by two 3-way valves (suction and return). Refer to the diagram below . Some important notes regarding the Pro Logic control of Standard Pool/Spa systems: In Pool/Spa Config., select: Po o l / S p a S e t up Po o l a n d ...

  • Goldline LOGIC PL-P-4 - page 27

    Wireless Remote Controls Note that the Pro Logic is compatible with AQL2 wireless remote controls only . A single AQL2-BASE-RF Base S tation must be installed on the Pro Logic in order to use any of the Goldline wireless remote controls. W ith the Base Station installed, there is no limit on the number of wireless remotes that can used. The maximum ...

  • Goldline LOGIC PL-P-4 - page 28

    Optional AQL-CHEM2 CO 2 Dispensing Kit The AQL-CHEM2 is a CO 2 dispensing device that connects directly to the Pro Logic. When used with an AQL- CHEM, the Pro Logic will sense the pool’ s pH level and automatically dispense the correct amount of CO 2 to control the pool’ s pH to the desired level. W iring and plumbing requirements for the AQL-C ...

  • Goldline LOGIC PL-P-4 - page 29

    2. Mounting the Equipment Pro Logic Control Center The Pro Logic is contained in a raintight enclosure that is suitable for outdoor mounting. The control must be mounted a minimum of 5 ft. (2 meters) horizontal distance from the pool/spa (or more, if local codes require). The Control Center is designed to mount vertically on a flat surface with the ...

  • Goldline LOGIC PL-P-4 - page 30

    4 Super Chlorinate – if “Chlorinator” is enabled, this option allows the user to start a Super Chlorinate cycle when the Aux button is pressed, rather than using the Settings Menu. Note that only one button can be assigned to this function. Aux1 Relay This feature allows the user to select either “Standard” (default) or “Dimmer” type ...

  • Goldline LOGIC PL-P-4 - page 31

    Gall o n s a n d ( L i t e r s ) o f P o o l / S p a w a t e r 12,0 00 14 ,00 0 16,0 00 1 8 , 0 0 0 2 0 , 0 0 0 2 2 , 0 0 0 3 2 , 0 0 0 2 4 , 0 0 0 3 4 , 0 0 0 2 6 , 0 0 0 3 6 , 0 0 0 2 8 , 0 0 0 3 8 , 0 0 0 3 0 , 0 0 0 4 0 , 0 0 0 Current salt level (45000) (52,500 ) (60,000) ( 6 7 , 5 0 0 ) ( 7 5 , 0 0 0 ) ( 8 2 , 5 0 0 ) ( 1 2 0 , 0 0 0 ) ( 9 0 ...

  • Goldline LOGIC PL-P-4 - page 32

    4. Electrical W iring (page 10) Main service Grounding and bonding Circuit breakers Pro Logic control power High V oltage pool equipment Low voltage wiring (temperature sensors, flow switch, etc.) 2 29 ºC º F Ti Calcuim Hardne ss Ci To t a l Alkalinity Ai 53 60 66 76 84 94 103 12 16 19 24 29 34 39 .3 .4 .5 .6 .7 .8 .9 How to use: Measure pool p H ...

  • Goldline LOGIC PL-P-4 - page 33

    Introduction Before Y ou Begin What’s Included Before attempting to install the Pro Logic system, check that the following components have been included in the package: Pr o Logic Electr onics Unit (3) T emperature sensors with 15 ft. (5m) cable, hose clamp What’s NOT Included Some of the additional items that you may need to complete an instal ...

  • Goldline LOGIC PL-P-4 - page 34

    T able of Content s Introduction Before Y ou Begin................................................................... 1 Installation S teps.................................................................... 2 1. Preparing General W ater Chemistry ..................................................... 2 Pool/Sp a W ater Salt......................... ...

  • Goldline LOGIC PL-P-4 - page 35

    IMPORT ANT SAFETY INSTRUCTIONS When using this electrical equipment, basic safety precautions should always be followed, including the following: • READ AND FOLLOW ALL INSTRUCTIONS • ! W ARNING: Disconnect all AC power during installation. • ! W ARNING: W ater in excess of 100 degrees Fahrenheit may be hazardous to your health. • ! W ARNING ...

  • Goldline LOGIC PL-P-4 - page 36

    Pro Logic Programming Flow Chart North Kingstown, RI 02852 USA 092337C Copyright © 2009 Goldline Controls www .goldlinecontrols.com Automation and Chlorination Inst allation Manual for model PL-P-4 LD C G LI N E ON T ROLS LD C G LI N E ON T ROLS denot es cond itiona l item s def ault m enu day a nd tim e wa ter temperat ure air t emperatur e chlor ...

Fabricant Goldline Catégorie CD Player

Les documents que nous recevons du fabricant de l'appareilGoldline LOGIC PL-P-4 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goldline
- manuels d’utilisations LOGIC PL-P-4
- fiches produit Goldline
- dépliants
- ou étiquettes-énergie Goldline LOGIC PL-P-4
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goldline LOGIC PL-P-4.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goldline LOGIC PL-P-4, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goldline LOGIC PL-P-4. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goldline LOGIC PL-P-4.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goldline LOGIC PL-P-4, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goldline LOGIC PL-P-4 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goldline LOGIC PL-P-4.

Le manuel d’utilisation complet Goldline, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goldline LOGIC PL-P-4 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goldline LOGIC PL-P-4, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoldline LOGIC PL-P-4 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goldline LOGIC PL-P-4 - qui devraient nous aider dans les premières étapes lors de l'utilisation Goldline LOGIC PL-P-4
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goldline LOGIC PL-P-4
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goldline LOGIC PL-P-4 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goldline LOGIC PL-P-4?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goldline LOGIC PL-P-4, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goldline LOGIC PL-P-4 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)