    MODEL 4501-XX 2-Wire Series TOXIC GAS SENSOR MODULE APPLICABILITY & EFFECTIVITY Effective for all Model 4501-XX Modules ma nufactured after September 1, 2006. 4501-04 FM Pending 4501-05 FM Approved 4501-06 FM Pending Instruction Manual Part Number T13022 Rev. A ...

  • Sierra Monitor Corporation 2-Wire Series - page 2

    Model 4501-XX Toxic Gas Sensor Module FM PERFORMANCE APPROVAL ONLY THE FOLLOWING ITEMS, FUNCTIONS AND OPTIONS ARE FM * APPROVED Model 4501-05 Hydrogen Sulfide Gas Sensor Module Sensor Module Model 4501-05 Sensor Module - Hydrogen Sulfide Calibration Equipment Model 1250-01 Gas Sensor Calibration Kit, Type A Model 1260-05 Hydrogen Sulfide in N2, 25 ...

  • Sierra Monitor Corporation 2-Wire Series - page 3

    Model 4501-XX Toxic Gas Sensor Module TABLE OF CONTENTS 1. PRODUCT D ESCRIPTION ......................................................................................................... .................... 1 1.1 GENE RAL .................................................................................................................... ........... ...

  • Sierra Monitor Corporation 2-Wire Series - page 4

    Model 4501-XX Toxic Gas Sensor Module Contents 7.4.2 CABLING INSTALLA TION ..................................................................................................... ................16 7.4.3 SENSOR MODUL E INSTALLATION ............................................................................................... ......16 7.4.4 MOISTURE ...

  • Sierra Monitor Corporation 2-Wire Series - page 5

    Model 4501-XX Toxic Gas Sensor Module 1. PRODUCT DESCRIPTION 1.1 GENERA L The Model 4501-XX Toxic Gas Sensor Module is a 2-wire transmitter with 4-20 mA output and it offers a broad array of features including: • 2-wire loop powered • 180 day calibration interval • Selectable ranges • Non-intrusive one-person calibration • Integral LCD 2- ...

  • Sierra Monitor Corporation 2-Wire Series - page 6

    Model 4501-XX Toxic Gas Sensor Module Page: 2 1.4 MECHA NICA L The sensor module is comprised of the following three primary components: 1.4.1 ENCLOSURE Explosion proof, rain-tight stainless steel electr ical housing with three ¾” FNPT conduit hubs. The enclosure cover has a viewing window. The 3 conduit hubs combined with the rotatable faceplat ...

  • Sierra Monitor Corporation 2-Wire Series - page 7

    Model 4501-XX Toxic Gas Sensor Module Figure 1-1 Model 4501-05 Hydrogen Sulfide Gas Sensor Module– Dimensions Figure 1-2 Model 4501-05 Hydrogen Sulfide Gas Sensor Module– Orientation Options Page: 3 ...

  • Sierra Monitor Corporation 2-Wire Series - page 8

    Model 4501-XX Toxic Gas Sensor Module 2. CAUTIONS & WARNINGS 2.1 INTRODUCTION Although the 4501-XX Gas Sensor Module is designed and constructed for installation and operation in industrial applications including hostile environments, caution should be taken to insure that the installation is made in compliance with this instruction manual and ...

  • Sierra Monitor Corporation 2-Wire Series - page 9

    Model 4501-XX Toxic Gas Sensor Module 3. QUICK START 3.1 OVERVIEW The gas sensor module has been supplied factory ca librated and ready for immediate installation and operation. An installer familiar with installation and oper ation of gas detection products can use this section to begin immediate use of the module. 3.2 WIRING Provide two conductor ...

  • Sierra Monitor Corporation 2-Wire Series - page 10

    Model 4501-XX Toxic Gas Sensor Module 4. INSTALLATION 4.1 SENSOR MODULE LOCA TIONS The gas sensor module utilizes a diffu sion type sensor which should be loca ted close to either the expected source or destination of the gas hazard. If the gas is heavier than air, the sensor module should be installed within 24 inches of the ground or floor. If it ...

  • Sierra Monitor Corporation 2-Wire Series - page 11

    Model 4501-XX Toxic Gas Sensor Module 1. Remove the transmitter from the module housing by: • Unscrew the two captive panel screws on the faceplate. • Lift the transmitter out of the enclosure. • Unplug the sensor cable fr om transmitter connector J1. • Remove the sensor assembly from the enclosure hub. 2. Install the module enclosure onto ...

  • Sierra Monitor Corporation 2-Wire Series - page 12

    Model 4501-XX Toxic Gas Sensor Module 5. OPERATION 5.1 INTRODUCTION The 4501-XX Toxic Gas Sensor Module utilizes a vis ual menu system operated by means of a magnet. A magnet stick is supplied for this purpose. The menu sy stem is used to calibrate the sensor module, and for maintenance and diagnostic procedures. The following adjustments can be ma ...

  • Sierra Monitor Corporation 2-Wire Series - page 13

    Model 4501-XX Toxic Gas Sensor Module 5.3 MA IN MENU Function Display Description Reference M E ST M E ST ME S T ME S T M E ST M E ST ME S T ME S T W arm 148 XX.XXaA Second scree n at start-up, c ount down of W arm - up H2S XXX.PP M Default Displa y (exam ple 4501-05) Key Mode Switch [M] Enter Switch [E] Up Switch [ ▲ ] Previous M enu Down Switch ...

  • Sierra Monitor Corporation 2-Wire Series - page 14

    Model 4501-XX Toxic Gas Sensor Module 5.4 MA INTENANCE SUB-MENU Function Display Description Refere nce M E ST ME S T M E ST M E ST ME S T M E ST M E ST ME S T ME S T M E ST M E ST Enter 4mA DONE Ack nowledges 4m A ca libration or Sub-Rou tine A M- Range 100 PPM Enter Cal ibrati on Range Menu Banner: Use [ S ] o r [ T ] to chan ge range, [E] when d ...

  • Sierra Monitor Corporation 2-Wire Series - page 15

    Model 4501-XX Toxic Gas Sensor Module 5.5 DIA GNOSTICS SUB-MENU Function Display Description Reference M E ST M E ST ME S T ME S T M E ST M E ST M E ST ME S T M E ST M E ST ME S T M E ST M E ST ME S T M E ST M E ST ME S T M E ST M E ST ME S T M E ST ME S T ME S T ME S T ME S T ME S T M E ST M E ST FactInit Done Factory initialization completed Ente ...

  • Sierra Monitor Corporation 2-Wire Series - page 16

    Model 4501-XX Toxic Gas Sensor Module 5.5.1 NOTES When selecting the output current requested, an acknowledge message will appear on the screen. Select [E] to accept this message. Whenever a message appears on the screen, select [E] to accept the message. No other action can be taken with messages. Except for the FactInit Menu, the sub-menus in t h ...

  • Sierra Monitor Corporation 2-Wire Series - page 17

    Model 4501-XX Toxic Gas Sensor Module 6. CALIBRATION 6.1 CA LIBRA TION FREQUENCY The sensor module must be calibrated every 180 days. Periodic functional tests are advisable for critical applications and hostile environments. The sensor module microprocessor software includes high-level self checking algorithms which provide continuous sensor diagn ...

  • Sierra Monitor Corporation 2-Wire Series - page 18

    Model 4501-XX Toxic Gas Sensor Module 6.3 DIA GNOSTICS SUB-MENU Functio n Display Description Reference M E ST M E ST M E ST M E ST M E ST ME S T M E ST M E ST Tabl e 6-1 Calibration S ub-M enu Sub-Routine A - A bort Calibration H2S XXX PPM Defau lt Di spl ay H2S CAL-FA IL Calibration Failed Sub-Routine C - Cali bration Fail Enter READ MANUAL Opera ...

  • Sierra Monitor Corporation 2-Wire Series - page 19

    Model 4501-XX Toxic Gas Sensor Module 7. SERVICE 7.1 SENSOR MODULE CONFIGURATION The gas sensor module is comprised of the following sub-assemblies (Figure 7-1): 4501-XX Gas Sensor Module SPL27077 Enclosure SPM27071 Transmitter Assembly XXXXXXX Sensor Assembly (see Appendix B) XXXXXXX Sensor (see Appendix B) There are no field serviceable component ...

  • Sierra Monitor Corporation 2-Wire Series - page 20

    Model 4501-XX Toxic Gas Sensor Module TRANSMITTER REPLACEMENT The transmitter assembly should be replaced when it is determined that it is unre liable, noisy or cannot be adjusted for calibration. This may occur due to age, corrosion or failed components. To replace the transmitter assembly: a. Remove the cover of the main enclosure b. Unscrew the ...

  • Sierra Monitor Corporation 2-Wire Series - page 21

    Model 4501-XX Toxic Gas Sensor Module • Wiring terminations clean and correct. 7.1.4 MOISTURE TRA PS A ND RA INSHIELDS • Conduit seals and drains installed to avoid moisture build up in electronics enclosure. Water accumulation in sensor module enclosures is a major cause of damage and system failures - take precautions to seal electrical condu ...

  • Sierra Monitor Corporation 2-Wire Series - page 22

    Model 4501-XX Toxic Gas Sensor Module 8. APPENDICES APPENDIX A: SPECIFICATIONS Specifications: Sensor: 4501-04 4501-05 4501-06 Max. Range (1) 0-1200 PPM 0-100 PPM 0-10 PPM Zero Drift +/- 1 PPM +/- 0.5 PPM +/- 0.5 PPM Repeatability +/- 1 PPM +/- 1 PPM +/- 0.5 PPM Linearity +/- 1 PPM +/- 1 PPM +/- 0.5 PPM Resolution 0.5 PPM 0.1 PPM 0.1 PPM Response T ...

  • Sierra Monitor Corporation 2-Wire Series - page 23

    Model 4501-XX Toxic Gas Sensor Module Page: 19 Warranty: Limited warranty : 2 y ear specificat ions subject to change without notice Model Number Gas Type CO H 2 S CI 2 H 2 SO 2 NO 2 NO HCI HCN C 2 H 4 4501-04-IT CO 100 5 0 <20 0 0 6 0 0 <50 4501-05-IT H 2 S <2 100 -20 <0.1 <15 -15 0 0 0 0 4501-06-IT C1 2 0 <-10 100 0 0 105 0 0 0 ...

  • Sierra Monitor Corporation 2-Wire Series - page 24

    Model 4501-XX Toxic Gas Sensor Module APPENDIX B: MODEL NUMBERS & PARTS LIST Sensor Module 4501-04 Sensor Module 2-w ire, CO 4501-05 Sensor Module 2-w ire, H2S 4501-06 Sensor Module 2-w ire, CI 2 Options 5394-52 Remote Sensor/Display Option 5311-00 Rainshield Calibration Items 1250-01 Gas Sensor Calibration Kit, Type A (CO , H 2 S) 1250-03 Gas ...

  • Sierra Monitor Corporation 2-Wire Series - page 25

    Model 4501-XX Toxic Gas Sensor Module Page: 21 APPENDIX C: LIMITED WARRANTY SIERRA MONITOR CORPORATION warrant s its products to be free from defec ts in workmanship or material under normal use and service for two years after date of shipment. SMC will repair or replace without charge any equipment found to be defective during the warrant y period ...

Fabricant Sierra Monitor Corporation Catégorie Carbon Monoxide Alarm

Les documents que nous recevons du fabricant de l'appareilSierra Monitor Corporation 2-Wire Series peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sierra Monitor Corporation
- manuels d’utilisations 2-Wire Series
- fiches produit Sierra Monitor Corporation
- dépliants
- ou étiquettes-énergie Sierra Monitor Corporation 2-Wire Series
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sierra Monitor Corporation 2-Wire Series.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sierra Monitor Corporation 2-Wire Series, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sierra Monitor Corporation 2-Wire Series. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sierra Monitor Corporation 2-Wire Series.

Manuel d’utilisation complet de l’appareil Sierra Monitor Corporation 2-Wire Series, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sierra Monitor Corporation 2-Wire Series par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sierra Monitor Corporation 2-Wire Series.

Le manuel d’utilisation complet Sierra Monitor Corporation, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sierra Monitor Corporation 2-Wire Series - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sierra Monitor Corporation 2-Wire Series, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSierra Monitor Corporation 2-Wire Series qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sierra Monitor Corporation 2-Wire Series - qui devraient nous aider dans les premières étapes lors de l'utilisation Sierra Monitor Corporation 2-Wire Series
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sierra Monitor Corporation 2-Wire Series
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sierra Monitor Corporation 2-Wire Series dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sierra Monitor Corporation 2-Wire Series?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sierra Monitor Corporation 2-Wire Series, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sierra Monitor Corporation 2-Wire Series il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)